Process Validation Regulatory & Practical View

แชร์
ฝัง
  • เผยแพร่เมื่อ 17 ก.ค. 2020
  • This training session will help you to understand process validation requirements as per EU,USFDA,TGA,ANVISA and WHO guide. Further will take through the common expectations from different regulatory guides. You will get answers for different questions like- What is difference in requirement of EU and FDA?, What are common errors made during process validations?, Exact difference between continued process verification and Product Quality Review? etc. This training session will provide overall insight about process validation strategy & designing the process validation protocol with practical approach.
    Cadila, Sanofi,Zydus, AstraZeneca,Mylan,Interview Questions with Sharma Ji,ASK Mechnology,emainfo,Qualistery - GMP Content,easy medical device,AA. Vedic Gyan. KD,PHARMA PORTAL,Prof.Karan Ajay Gupta,Pharma Pill,Vivekanand Education Society's College of Pharmacy,
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 147

  • @lifeonearth5321
    @lifeonearth5321 2 ปีที่แล้ว +1

    After 1 year I can hear you and can see your screen. And I can see you too. Your voice is outstanding

  • @preetisandeepshukla6547
    @preetisandeepshukla6547 3 ปีที่แล้ว +3

    Thank u very much sir for detail explaining the guidelines and requirements

  • @SonuYadavBawaliya1
    @SonuYadavBawaliya1 3 ปีที่แล้ว +2

    Best presentation
    Help me to known more about process validation
    Thanks sir

  • @surajsinghbhandari6
    @surajsinghbhandari6 ปีที่แล้ว +2

    I appreciate your efforts sir, thanks for this type of informative webinar

  • @jahan6057
    @jahan6057 2 ปีที่แล้ว +1

    Thank u so much. The way explain about EU and US guidance is very good sir.

  • @rupeshrajput5560
    @rupeshrajput5560 10 หลายเดือนก่อน +1

    We appreciate to you sir ,it was the nice training and learnt lots of about same topic

  • @samvdio7513
    @samvdio7513 3 ปีที่แล้ว +1

    Thank you, really good presentation

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  3 ปีที่แล้ว +1

      Thank you so much for your kind comment. Keep Learning !!!

  • @ajayrathod5042
    @ajayrathod5042 8 หลายเดือนก่อน +1

    Yes

  • @MOHANKARTHIK7777777
    @MOHANKARTHIK7777777 7 หลายเดือนก่อน +1

    Hi sir i just have one doubt could you revert,in which stage are we doing our validation of newly introduced product ..

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  7 หลายเดือนก่อน

      Which stage means? Newly introduced product should be done prospectively. i suggest you can further elaborate your question.

  • @vivekrana8636
    @vivekrana8636 10 หลายเดือนก่อน +1

    Thank you sir for very informative Training

  • @santoshthorat5314
    @santoshthorat5314 3 ปีที่แล้ว +1

    Thank you so much sir, your videos are very informative n helpful 🙏👍 also would u please prepare video for post approval changes for US & EU

  • @dantusambireddy8851
    @dantusambireddy8851 ปีที่แล้ว +1

    Excellent

  • @lathashree9201
    @lathashree9201 ปีที่แล้ว +1

    Thank you so much sir this video is very useful for me and moreover if you don't mind please make one video for fishbone diagram and five why concept..thank you sir...

  • @seemakurthisureshbabu4133
    @seemakurthisureshbabu4133 3 ปีที่แล้ว +1

    I am a big fan of u sir

  • @PrasannaKumar-vm9rt
    @PrasannaKumar-vm9rt 3 ปีที่แล้ว +3

    Helll sir
    Namasthey
    Myself prasanna kumar.
    Your class is absoluetly awesome.
    Sir one topic might be easier to all but dont know why that never fed in my mind perfectly .
    that is cp cpk pp ppk
    Difference between them all
    Weighing balance calibration
    Criteria for selection of standard weights.
    Equipment qualification
    False tree analysis
    Risk for Software updation
    Tq sir

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  3 ปีที่แล้ว +1

      Thank you for suggesting the topics. I will definitely take training on these topics.

  • @drx.kalpeshgayakwad6094
    @drx.kalpeshgayakwad6094 3 ปีที่แล้ว +1

    Dear can you please explain me
    When we perform BU Sampling
    Manny time I found some people tabbing sampling rod inside the bland for properly fill die cavity. But even if the die is not fill properly, then it goes out of the way and put it back into the blend, and again the samples come back from the same place.
    I think doing this can cause a bland disturbance
    Is that correct way.
    Because we do die selection on the basis of bulk density
    My question is very big, so please explain in detail
    I hope you make a presentation video on BU and stetified sampling.
    Thanks

  • @drx.kalpeshgayakwad6094
    @drx.kalpeshgayakwad6094 3 ปีที่แล้ว +2

    Dear sir
    I just want to know
    If we have one validated product #ABC on machine ex.glatt autocoater.
    We have same other auto coater same make modal
    Can we take #ABC batch on other machine on the basis of risk assessment.
    Please suggest.
    🙏🏻🙏🏻

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  3 ปีที่แล้ว

      Yes. You can perform QRM, check the impact and make sure that, the change in equipment will not impact on variability of the product.

  • @alkasingh5417
    @alkasingh5417 2 ปีที่แล้ว +1

    Sir second query is about hold time study.
    Manufacturing sites done hold time study. But as per practice hold time study sample do not check for stability study means long term impact was not assessed.
    However based on hold time study during routine manufacturing of product holds in between stages such as between granulation & compression .
    It this practice ok
    I have observed OOS for moisture and temperature sensitive product in which holding during mfg was done .

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  2 ปีที่แล้ว

      FDA raises the concern about specific samples for HTS. It is recommended to keep the whole batch for HTS. So that, the same batch can be charged on stability study.

  • @rajathathireddy3285
    @rajathathireddy3285 3 ปีที่แล้ว +1

    Dear sir, All topics covered in your webinar, apart from marketing complaint and Product recall.
    Can you pls take a webinar on Marketing complaint and Product recall.

  • @ponnanasridhar1944
    @ponnanasridhar1944 3 ปีที่แล้ว +1

    Good sir

  • @preetisandeepshukla6547
    @preetisandeepshukla6547 3 ปีที่แล้ว +1

    Sir one of my question is if we have process validation for domestic market and is it process validation required for export batches if only grade change of raw material s

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  3 ปีที่แล้ว

      We need to evaluate in detailed. Please check - Whether any formula is changed. Specification of RM and FP is changed, Any equipment or batch size is changed? Any manufacturing process is changed? Please enlist the details of changes to evaluate.

  • @peakyblinder2937
    @peakyblinder2937 ปีที่แล้ว +1

    Sir, what will source for rationale as in MFR there is no rationale provide d, what could be the supportive document

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  ปีที่แล้ว

      Can you please clarify your question again. Sorry but I am not able to understand. Thank you for sharing question again.

  • @shiprasingh6016
    @shiprasingh6016 2 ปีที่แล้ว +1

    sir ...please make a vedio on sampling procedure in integrated line of granution used for manufacturing of hazardous product...like oncology product....because due to personal safety equipment can't open..so how to done sampling at different locations..

  • @rupeshrajput5560
    @rupeshrajput5560 10 หลายเดือนก่อน +1

    Sir...one batch can be taken for process validation at first commercial order after 1 or more years of exhibit batches (3 batches)

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  8 หลายเดือนก่อน

      Can you please elaborate your question in detail.

  • @snwani9109
    @snwani9109 3 ปีที่แล้ว +1

    I have two products with different brand name, but formulation is same, only new pack profile is introduced, I have to perform process optimization and process validation from packing stage. Primary packing material of both brand is same in all respects, can I prepare a common protocol for both brands?

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  3 ปีที่แล้ว

      I suggest you can go through the same recorded webinar in detail. you will get your answer. I need Just one clarity- do mean to ask for packing process validation or mfg process validation? Further whether the packing configuration is changed?

    • @snwani9109
      @snwani9109 3 ปีที่แล้ว +1

      @@hitendrakumarshah3718 Sir only packing validation, pack profile of both brand is same, MOC is same, vendor of primary packing material is same,

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  3 ปีที่แล้ว +1

      @@snwani9109 Yes. I do agree. But, if the different packs are for different customer or different market, it is good practice to prepare separate protocol otherwise both validation will come in picture every time during the audit. Hope, you got my point.

  • @ulhasdesale2363
    @ulhasdesale2363 3 ปีที่แล้ว +1

    We are following revalidation criteria for change in equipment, facility, process, KSM supplier etc. If CPV apprach is followed then is there requirement of revalidation?

  • @sivanagireddyvanga1131
    @sivanagireddyvanga1131 3 ปีที่แล้ว +1

    dear sir suppose my API KSM input range is 150 to 200. does it mandatory to validate with 3 batches with 150kg , 3 batches with 200kg and 3 batches with 175 kg

  • @manishkumarsingh2601
    @manishkumarsingh2601 3 ปีที่แล้ว +1

    Thanks sir for making such informative video.
    I am a big fan of yours.
    I gained some knowledge too from your videos. But, i can't apply these in my job profile as here I am working in Hyderabad based formulation company in packing department (Blister & bottle line) as an associate (Consider it as an operator). I am a B.Tech graduate in Mechatronics stream working since 2 & half years. But, i want to work in process validation area.
    Sir, please suggest me the way to switch from my profile to process validation as it's seems difficult because I don't have hands on experience in that.
    Waiting for your reply.
    Yours obedient.
    Manish singh

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  3 ปีที่แล้ว +1

      I suggest to learn the topic completely which you are interested. for example - process validation. involve yourself for discussions or investigations related to failures. During appraisal, you can speak with your head and HR about change in job profile. For further support, you can go through all topics and feel free to put your questions in comment section.

    • @manishkumarsingh2601
      @manishkumarsingh2601 3 ปีที่แล้ว

      @@hitendrakumarshah3718 Thanks for your reply sir. It's really a nice gesture of yours.🙏

  • @AnkurSharma-ob8od
    @AnkurSharma-ob8od 3 ปีที่แล้ว +1

    Hi sir, my question related to API vendor qualification during process validation. Is it necessary to perform process validation if API vendor change the manufacturing location to make API... Meanwhile API SOURCE and manufacturing process of API preparation is same. Vendor already qualified by RA but the vendor change only manufacturing location??

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  3 ปีที่แล้ว +1

      This change should be evaluated. Whether the change will impact on product quality? or CPP or CQA?

  • @naushadvasaya4585
    @naushadvasaya4585 3 ปีที่แล้ว +2

    Packing validation required at submission batches mfg...?

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  3 ปีที่แล้ว

      As, the packaging material will likely to change in commercialisation, You can consider finished product testing. You can consider some basic tests but title should be process validation only.

  • @janmejaypatel9915
    @janmejaypatel9915 3 ปีที่แล้ว +1

    Nice presentation.
    During compression validation if we go for high hardness test then thickness value will go outside the limit. if we go for a low hardness test then thickness also come out of the limit. What to do in those circumstances??

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  3 ปีที่แล้ว

      First you have to evaluate which is your critical process parameter? If Hardness is CPP, and thickness is non CPP, by following deviation procedure you can handle. But, if your CQA is thickness, you should not cross the CPP.

    • @janmejaypatel9915
      @janmejaypatel9915 3 ปีที่แล้ว +1

      Hitendrakumar Shah Thanks for your reply but both hardness and thickness are considered as a CQA I cannot choose either of them so how to balance both the things in validation.

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  3 ปีที่แล้ว +1

      @@janmejaypatel9915 I think, hardness is CPP for you and Dissolution will be CQA. The thickness due to slight change may not impact on product quality except may create difficulty during packing. Actually, this aspects should be studied at development stage only because, the hardness and thickness limit will be given to you by development only. Development should evaluate whether the thickness will be within limit or not if hardness is maintained within design space. At this moment, you can evaluate the above case for your product and accordingly raise deviation. This problem need to be investigated through deviation so that at least next time, your development team should able to concentrate this aspect before technology transfer. Hope you got answer to your question.

    • @janmejaypatel9915
      @janmejaypatel9915 3 ปีที่แล้ว

      Hitendrakumar Shah Yes Sir Thanks

    • @surajsinghbhandari6
      @surajsinghbhandari6 ปีที่แล้ว

      Thanks sir same situation occurred in our manufacturing so I get the answer from you.

  • @jawwadkhan7851
    @jawwadkhan7851 ปีที่แล้ว +1

    Sir prospective validation batches can be marketed for sale and why revalidation is done when we have concurrent validation ????

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  7 หลายเดือนก่อน

      I think there some confusion. I suggest please elaborate your question in detail so that, I will able to reply properly.

  • @jagdeeshprasadmangal7698
    @jagdeeshprasadmangal7698 2 ปีที่แล้ว +1

    Can be release pre validation, optimization batch shall be release for market selling if yes so kindly provide guideline referance

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  2 ปีที่แล้ว

      The answer is Yes. It need to be evaluated case by case basis. Only after complying to respective specification.

  • @alkasingh5417
    @alkasingh5417 2 ปีที่แล้ว +1

    Sir I have query regarding process validation.
    Blending process need to validated 10 rpm, 12 and 15 rpm,
    Option 1- operator run the blender for 10 rpm take out sample thn run for again 2rpm and takeout sample and again run for 3 rpm and take out sample.
    Option 2- in rnd batch divided in to three lot and blender run on lot for low, other for optimum & max rpm.
    Which is correct procedure.

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  2 ปีที่แล้ว

      Option 1- is not correct at all. During validation, we are not supposed to do optimization. . I suggest, you take the engineering/optimization batch and evaluate it.

  • @jagdeeshprasadmangal7698
    @jagdeeshprasadmangal7698 2 ปีที่แล้ว +1

    Dear sir more thanks but only one question
    How to implement and how to carried out with how many batches for continuous verification

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  2 ปีที่แล้ว

      I suggest, I have explained the details in this video. You can again go through the same. I think, may be in Q&A session.

  • @vikaspharma87
    @vikaspharma87 2 ปีที่แล้ว +1

    What if pv not done on consecutive batches..what is meant by consecutive..if i am manufacturing 1 batch today, second batch after 4 months and third batch after 1 month of second batch...same is acceptable or not

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  2 ปีที่แล้ว

      This is consecutive. For PV consecutive batches should be considered.

  • @Bharatpithiyalive
    @Bharatpithiyalive 5 หลายเดือนก่อน +1

    First three validation batches there is BMR filling required or not?

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  5 หลายเดือนก่อน +1

      Yes. of course.

    • @Bharatpithiyalive
      @Bharatpithiyalive 5 หลายเดือนก่อน

      Sir can you please help to prepared cleaning validation protocol of ointment manufacturing vessels and clean equipment hold time study protocols

  • @thiyagarajanannasamy2309
    @thiyagarajanannasamy2309 3 ปีที่แล้ว +1

    Hi sir,
    Please provide a training on US FDA 21 CFR part 820.

  • @ulhasdesale2363
    @ulhasdesale2363 3 ปีที่แล้ว +1

    Is this guideline applicable to API industry because in whole session I didn't heard any explanation about API industry also PIC guidelines emphasise the applicability of this guideline for different dosage forms

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  3 ปีที่แล้ว +1

      YES. This guideline is applicable for API industry also. The PIC/S suggest applicability of GMP requirements for different type of pharmaceutical entities. Not just process validation.

    • @ulhasdesale2363
      @ulhasdesale2363 3 ปีที่แล้ว +1

      @@hitendrakumarshah3718 Thank you Sir

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  3 ปีที่แล้ว

      @@ulhasdesale2363 Welcome Keep Learning !!!

  • @Chikuonline
    @Chikuonline 10 หลายเดือนก่อน +1

    Sir thank you for such a good video.
    I have taken 03 batch for PV and assay results is 102%, 101%, 96% then how to evaluate the results? Because thirds batch have lower assay.

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  8 หลายเดือนก่อน

      You need to evaluate variability as per the FDA guide.

    • @Chikuonline
      @Chikuonline 8 หลายเดือนก่อน +1

      Please explain how to evaluate variability as per the FDA guide

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  8 หลายเดือนก่อน

      @@Chikuonline I will take a separate session on this topic.

  • @nikhilverma1560
    @nikhilverma1560 ปีที่แล้ว +1

    If the batch size is increase, does tha process validation required or not???

  • @Sivakumar-sankagiri
    @Sivakumar-sankagiri ปีที่แล้ว +1

    Sir Could you explain how to select sampling during blending stage?

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  ปีที่แล้ว

      What exactly you need. Please clarify your question so that, I can guide you correctly

  • @sunilrathore2046
    @sunilrathore2046 3 ปีที่แล้ว +1

    Sir, good training session. If you discuss problem observed during validation batches like oos, any event during manufacturing etc.the what it's impact on that validation batch
    Plz discuss.

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  3 ปีที่แล้ว +1

      I understand your requirement. As, you are well aware that, I am arranging FREE learning for all. This topic is very big and require at least 2 full days to discuss completely. I am considering all points during my full two days seminar - like practical problems with examples during validation, statistical evaluation by different methods, reduced validation testing scenario, compliance approach to continued process verification, discussion on examples of FDA citations and many more. These all points not possible in just 1-2 hours.

  • @gajananshelke8991
    @gajananshelke8991 2 หลายเดือนก่อน +1

    Non critical process parameters are mentioned is EU guidelines but sir where it is mentioned in EU guidelines

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  2 หลายเดือนก่อน

      Annex 15 "Process validation should establish whether all quality attributes and process
      parameters, which are considered important for ensuring the validated state and
      acceptable product quality, can be consistently met by the process. The basis by
      which process parameters and quality attributes were identified as being critical
      or non-critical should be clearly documented, taking into account the results of
      any risk assessment activities."

  • @poojagangishetty5518
    @poojagangishetty5518 3 ปีที่แล้ว +1

    How many maximum sampling points taken for validation batch. Purpose

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  3 ปีที่แล้ว

      You need to evaluate based on equipment, product and process.

  • @samuelmarie1267
    @samuelmarie1267 2 ปีที่แล้ว +1

    which specification is more tighter In process or finished product?thank you

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  2 ปีที่แล้ว

      It depends on the process which is being followed. However, as a generic case, we can have stringent limit at inprocess stage. While finished product limit can be relaxed one.

    • @samuelmarie1267
      @samuelmarie1267 2 ปีที่แล้ว

      I thank you sir. Can you direct me which guidelines point this fact beyond our general thought.

  • @rajathathireddy3285
    @rajathathireddy3285 3 ปีที่แล้ว +1

    Dear sir, Please take a presentation on vendor management.

  • @kvkrishnareddy4044
    @kvkrishnareddy4044 ปีที่แล้ว +1

    Please any one answer me why periodic validation while doing continued process verification

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  ปีที่แล้ว

      During periodic validation, you are evaluating all the aspects including equipment also. So, it is required.

  • @DineshKumar-sd3zf
    @DineshKumar-sd3zf 3 ปีที่แล้ว +1

    Please post about autoclave validation

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  3 ปีที่แล้ว

      Yes. I need to prepare it. Definitely I will prepre video on it.

  • @ulhasdesale2363
    @ulhasdesale2363 3 ปีที่แล้ว +1

    Dear Sir
    What is mean by stratified sampling please explain?

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  3 ปีที่แล้ว +1

      stratified sampling is performed during the process validation. There was separte FDA guideline for this aspect. This guideline is withdrawn by FDA but still it is in practice and followed.

    • @ulhasdesale2363
      @ulhasdesale2363 3 ปีที่แล้ว +1

      @@hitendrakumarshah3718 Thank you Sir

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  3 ปีที่แล้ว

      @@ulhasdesale2363 Welcome. Keep learning !!!

  • @bhushanpdhangar1801
    @bhushanpdhangar1801 หลายเดือนก่อน +1

    Sir drying is critical process parameters

  • @bijoyghosh7729
    @bijoyghosh7729 3 ปีที่แล้ว +1

    Hi
    I want to take continuous guidance from you. How ?

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  3 ปีที่แล้ว

      Be in touch with me. Subscribe youtube channel and request to share the link to your colleagues for subscribing youtube channel. Thanks

    • @AnkurSharma-ob8od
      @AnkurSharma-ob8od 3 ปีที่แล้ว +1

      Amazing sir

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  3 ปีที่แล้ว

      @@AnkurSharma-ob8od Thank you. Keep Learning !!!

  • @sadyojathaitagi4061
    @sadyojathaitagi4061 2 ปีที่แล้ว +1

    What is concurrent release,

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  2 ปีที่แล้ว

      I suggest to go through the video in detail. It is explained. If you have further any questions, please feel free to ask in comment section.

  • @kvkrishnareddy4044
    @kvkrishnareddy4044 ปีที่แล้ว +1

    Why periodic validation of process

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  ปีที่แล้ว

      To evaluate the variability and ensure no impact of variability

  • @veenapandit3921
    @veenapandit3921 3 ปีที่แล้ว +1

    Who is responsible for preparation of process validation protocol? Why?

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  3 ปีที่แล้ว +1

      It depends on organisation. It can be prepared by QA or even developement QA or R&D.

    • @veenapandit3921
      @veenapandit3921 3 ปีที่แล้ว +1

      @@hitendrakumarshah3718
      Thank you for guidance...

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  3 ปีที่แล้ว

      @@veenapandit3921 Welcome !!!

  • @bijoyghosh7729
    @bijoyghosh7729 3 ปีที่แล้ว +1

    Hi

  • @sreedevitv86
    @sreedevitv86 2 ปีที่แล้ว +2

    Yes

    • @hitendrakumarshah3718
      @hitendrakumarshah3718  2 ปีที่แล้ว

      Thank you so much for your kind confimation

    • @sreedevitv86
      @sreedevitv86 2 ปีที่แล้ว

      How many lots of APi used for zEu and fda

    • @sreedevitv86
      @sreedevitv86 2 ปีที่แล้ว

      How many lots of API to be used for exhibitb process val

  • @sreedevitv86
    @sreedevitv86 2 ปีที่แล้ว +1

    Yes

  • @mistryharshad0007
    @mistryharshad0007 3 ปีที่แล้ว +1

    Yes

  • @sandhyasingh8057
    @sandhyasingh8057 3 ปีที่แล้ว +1

    Yes