Dear Brother, the explanation is simply superb. I never had this much simpler explanation till date. Really hats off to you. I subscribed your channel and will ask whenever any topic needed for explanation certainly, we will reach you. Thank you very much for your simplest way of explanation.
Very Nice video sir... Ek doubt hai Wiring main LV terminal ke output mai jo Fuse holder lagaye hai usme fuse lagaye nahi hai to Rn mai Voltage nahi milega na...jab tak sabhi LV terminals main fuse dalkar Circuit complete (star) na ho tab tak pls suggest.. Thank You
th-cam.com/play/PLx0rjIgzpjZnhEV2CnRwWVqJkiK86hfDu.html all transformer routine test, battery impidance test and LCM test is in this play list also in future you will find other test in this play list.
Thanks for watching 👍..we are glad to know that we have helped you to learn concepts..keep watching. we will definitely come to your point in future...
it is the method for any mesurment, that we fixed one known point and in referance of that other mesurment may be done, so as we short R and r, the voltage between R & r is zero.
Namasthe sir🙏 mera Nam Siva Prasad from andhra pradesh sir me Kuwait 🇰🇼 gulf oil nd gas plant me kam karaham. Sir electrical drawings kaise padna explain karo ji
Bahut hi badhiya sir...bahut ache se explain kya hai aapne ...aise hi video bnate rhiye ....thanku so much 🙏
Thanks for watching 👍..we are glad to know that we have helped you to learn concepts..keep watching.
Your way of expalination is awesome..Easy way to understand. thank you so much..
Highly appreciated , Your articulated Explanation and the animation you made thanks a lot 🙏
You r amazing sir nice Way of explaining thank you so much ❤❤
Thanks sir aaj mene aap ka ye video dekha or aaj jakar mujhe vector group ko achchi tarah se samaj gaya thank you very much sir
keep learning....
Thank you sir really appreciated work ...I really waiting for your upcoming videos which is totally based on power testing equipments
Thanku sir...❤️ Your explanation and presentation is very nice❤️👍
Dear Brother, the explanation is simply superb. I never had this much simpler explanation till date. Really hats off to you. I subscribed your channel and will ask whenever any topic needed for explanation certainly, we will reach you. Thank you very much for your simplest way of explanation.
thank you... keep learning and share to your frainds...
Sir ,What will be the procedure for dyn1?
Please do give a reply
many video youtube only you explain very well thanks
Very Nice Sir...well done...what a clear animation it is....very well understand for everyones
Thank u sir. Bahut acha smjhate ho aap.
Very informative ......Sir. Thanks Aton for your efforts
Highly appreciated 👍👍
Best animation video for Explaining about x'mer vector group
So GooooooD Explained Sir . Really appreciate 🎉🎉
Best explanation on Vector Group test ... 👌
Excellent
Thank you sir
Nice👍👍👍 sir,, sir other vector group ke upr bhi video bnao sir Dyn1 and etc. Sir iska use kyo kiya jata hai different different vector group me
It's really help ful for me sir plz tell what is the purpose behind this type of phasor and how many can we used
Supply konsi or kitni volt deni hai
Very nice explain and very informative video's keep it up.
Thank you very much
Thanks for watching 👍..we are glad to know that we have helped you to learn concepts..keep watching.
Generator Transformer me neutral ground karna jaruri hai...?
Very Nice video sir...
Ek doubt hai
Wiring main LV terminal ke output mai jo Fuse holder lagaye hai usme fuse lagaye nahi hai to Rn mai Voltage nahi milega na...jab tak sabhi LV terminals main fuse dalkar Circuit complete (star) na ho tab tak pls suggest..
Thank You
that is the out put of transformer...
if you provide fuse then LV will be shorted...
Nice sir ji. GIS par bhi video banaiye
Sir why u didn't connect LV side Fuses?
Sir substation me ky ky test hote hai sab bataiye na all equipment jo jo Switchtyard me lage hote hai
th-cam.com/play/PLx0rjIgzpjZnhEV2CnRwWVqJkiK86hfDu.html
all transformer routine test, battery impidance test and LCM test is in this play list
also in future you will find other test in this play list.
Good animation. Easy for understanding 👍👍
Maza aagaya
Very informative ......Sir please make video of 11kV capacitor bank NCT ,RVT and how it reduce loss and effect on financial saving
Thanks for the knowledgeable video
What advantage in +30,deg .or -30deg.shift in angle why do this??
Very easy to unrderstood...nice video
Very nicely explained sir
Good method of teaching
Very nice explanation bro
Very nice 👍 explain,sir
Really nice explanation sir
Thanks for watching 👍..we are glad to know that we have helped you to learn concepts..keep watching.
Very useful to me.. please make a video on OLTC (Diverter mechanism)control wiring.
Can you explain Yna0D11 vector diagram.
Explanation level is best sir❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤
Sir, this is very informative video.
My question is, if the test results are not found satisfactory then what we can conclude?
Thanks for watching 👍..we are glad to know that we have helped you to learn concepts..keep watching.
we will definitely come to your point in future...
should the low side kept open?
Why did you short R & r Sir ? Would you mind explaining the same ?
Sir , Aap Kuchh reply hi nahin Kiye ki kyon Aapne R aur r ko Short kiya .
Excellent sir keep it up
During vector test, why are you not insert fuse in LV SIDE? In testing kit above fuse
This test for vector group not for short circuit test.
Thank you sir 👍, well explained sir
How much supply voltage give to kit and how much voltage from kit to transformer Lv and Hv
3-ph ac supply. 440V ac.
Very useful information.
Lv side mai fuse open hi rehega sir?
Yes.
Please make video on VFD Drive of motor. Abb vfd with all pannel connections
Testing k liye voltage kitna Dena hoga
440V 3-ph supply...
Please explain Yna0D11 auto transformer winding.......
Well explained sir
yeh sab online hoga means whent transformer is connected to supply
no, it is to be done in LT supply 440v
Thank you Sir, Please explain vector group test for YNyn0d11 Transformer. Thank you so much.
Great work👍
Good explanation sir
Very informative 🙏🙏
Very nice..thank u..
You are great ❤
Superb sir
Through testing kit how much supply voltage use?
3 ph supply, 440 v
Excellent work
Sir R,r short karane par short circuit nahi hoga
no, it is not connected electrically in transformer.
it is connected through magnetic fields.
@@Insighttecs ji sir , thanks
Sir please tell me why for doing vector group test ?
there is a condition of parallel the transformer,
vector group should be same...
also,it is one time test.
Khub saras
V nice sir
Very well explained
Thank you❤
Very useful
Well explained
Wow great 100%
Why the R and r are shorted ? Plz explain
it is the method for any mesurment, that we fixed one known point and in referance of that other mesurment may be done, so as we short R and r, the voltage between R & r is zero.
Not understand why R&r short please explain
Superb
Nice video
Thank you sir ❤
Most welcome
Sir very very good aapse baat ho sakti hai kya sar
mail on insight.tecs@gmail.com
Thanks bro...
Thank you so much sir
Sir
If both winding in star
delta-star...
Prectical karwa dijiye
Why we shorted hard primary secondary and all in dame R tor shorted
to verify the vector group of transformer, i.e 3 ph winding connection
❤ nice
Very good 🙏🙏🙏🙏🙏
Why Rr is shorted and not other i.e. Yy etc
to test the vector group of transformer.. Dy11,
chack the possible combination and you can try...
Thank you sir
Thanks
👍👍👍👍
Please Explain Dyn 1
Plz make vid on ttr test
th-cam.com/video/SPQIL9YdU2c/w-d-xo.html
Sir transformer jitna tast hai dijia sir please , Jaldi video dijia sir upka Chennal may
already there on the chhenal.
th-cam.com/play/PLx0rjIgzpjZnhEV2CnRwWVqJkiK86hfDu.html
यदि आप ट्रांसफॉर्मर के वेक्टर समूह को नहीं जानते हैं, तो समानांतर कनेक्शन कैसे बनाया जाए
Your concept not clear
Delta to star ka okay sir star to delta transformer ka test kaise karthe
🤝🤝
Namasthe sir🙏 mera Nam Siva Prasad from andhra pradesh sir me Kuwait 🇰🇼 gulf oil nd gas plant me kam karaham. Sir electrical drawings kaise padna explain karo ji
please go through the series bellow,
th-cam.com/play/PLx0rjIgzpjZnNYaHQJvuN2_-YnEZ3fXb1.html&si=XFIfasOMaDPYu0f8
Turn ratio test???
th-cam.com/video/SPQIL9YdU2c/w-d-xo.html
Sir tr Dy11 type nu che. Means lv lags hv by 30 deg.
Pan tame 4:50 par hv and lv ne in phase lai ne km karyu e samjayu nahi
to verify the vector group...
why using phase shifting
Very good question
3 + 3 × 3 = 3 × 9
= 27
Dyn11 not Dy11