  • Aaj k is video me hum dekhenge ki deflection kya hota h,according to IS Code 456:2000 kisi bhe beam me maximum deflection kitna ho sakta h, Beam k deflection ko contol karne k liye kya kiya jaa sakta h, Deflection of beam ya beam ka deflection span to effective depth ratio par kaise depend karta h,Kisi bhi beam k liye span to effective depth ratio kitna hona chahiye, simply supported beam ke liye span to effective depth ratio kitna hona chahiye,Cantilever beam ke liye span to effective depth ratio kitna hona chahiye,Continious beam ke liye span to effective depth ratio kitna hona chahiye, Reinforcement pr deflection kaise depend karta he, tension reinforcement ke liye modification factor kitna hota he, Compression reinforcement ke liye modification factor kitna hota he,Modification factor kya hota h,
    In todays lecture we will study that what is deflection,What should we do to controle the deflection of a beam ,What is the limit of maximum deflection of a beam,What is the limit of maximum deflection of a Simply supported beam,What is the limit of maximum deflection of a Cantiler beam,What is the limit of maximum deflection of a continious beam,what is span to effective depth ratio,what is modification factor

ความคิดเห็น • 30

  • @himanshunotiyal9269
    @himanshunotiyal9269 9 หลายเดือนก่อน +1

    Bahut khub

  • @user-pp8wl4kq9p
    @user-pp8wl4kq9p 22 วันที่ผ่านมา

    Best 🎉

  • @kennedy-zs1go
    @kennedy-zs1go 2 ปีที่แล้ว

    Outstanding contribution just carry on

  • @keshavkishorsahay1515
    @keshavkishorsahay1515 2 ปีที่แล้ว

    Very well explained 🙏
    Thank you 😊

  • @ssconsultants1750
    @ssconsultants1750 2 ปีที่แล้ว +1

    good information, make more videos

  • @engineerirfancheema9328
    @engineerirfancheema9328 2 ปีที่แล้ว

    Great video sir carry on

  • @msrinivasakannan
    @msrinivasakannan 2 ปีที่แล้ว

    Nicely explained sir

  • @sudiptachaudhury9820
    @sudiptachaudhury9820 2 ปีที่แล้ว

    well explained..

  • @aamir6976
    @aamir6976 2 ปีที่แล้ว +1

    Tq

  • @axatrathod
    @axatrathod 8 หลายเดือนก่อน

    👌🏼👌🏼👌🏼

  • @Demonslayer-lt4qf
    @Demonslayer-lt4qf ปีที่แล้ว

    Span is effective or clear span?

  • @sj55gh
    @sj55gh 11 หลายเดือนก่อน

    When will we take l/350

  • @rahulmaurya9003
    @rahulmaurya9003 ปีที่แล้ว

    Baki ka videos banao sir plz🙏

  • @ashishvishvakarma1132
    @ashishvishvakarma1132 2 ปีที่แล้ว

    More imp video for CE

  • @somnathkarmakar1801
    @somnathkarmakar1801 2 ปีที่แล้ว

    @8.53 check span / d value. Upto 10m

    • @valleytoridge9821
      @valleytoridge9821  2 ปีที่แล้ว +1

      It was a mistake in summery, kindly ignore it I have explained earlier in this video.
      Thanks for you valuable response.

    • @somnathkarmakar1801
      @somnathkarmakar1801 2 ปีที่แล้ว

      @@valleytoridge9821 wlcm Sir

  • @diplomajunction176
    @diplomajunction176 2 ปีที่แล้ว

    Kindly check at 8:47

    • @foundationtopeak7451
      @foundationtopeak7451 2 ปีที่แล้ว

      What should i check?

    • @diplomajunction176
      @diplomajunction176 2 ปีที่แล้ว

      @@foundationtopeak7451 sir you have interchanged the l/d ratio for cantilever and simply supported

    • @valleytoridge9821
      @valleytoridge9821  2 ปีที่แล้ว +2

      Sorry for the mistake and thank you to realiz my mistake.actually at the end it was a summery kindly ignore it.

  • @PintuLal-wf7mj
    @PintuLal-wf7mj หลายเดือนก่อน

    Sir last me values wrong kr diye ho cantilever or simply supported beam ki..app change kr diye ho ak dusare ki values...pls correct it

    • @valleytoridge9821
      @valleytoridge9821  หลายเดือนก่อน

      Yes dear , sorry for that . last me Jo summary batai usme mujhse mistake ho gyi. Uploaded video me correction mushkil h ,,please consider dear.

  • @Arsiddique.RPM.doctor
    @Arsiddique.RPM.doctor 2 ปีที่แล้ว

    Sir contiliver beam span 10m length hai to L D fix column me Kitna Hoga
    कंटिलिवर बीम में स्पान 4 मीटर आगे तक है तो उसका एंकर लेंथ LD development , पिछे कालम में कितना जाएगा formula explain करे और मुझे बताइए सर इंटरव्यू में पुछा था
    Please reply me sir

    • @valleytoridge9821
      @valleytoridge9821  2 ปีที่แล้ว

      Aapka question thik se samjh nhi aaya,please question clear kare mujhe, aap development lenth k liye puch rhe h ya L/D ratio k liye.

    • @vishvasmeshram6094
      @vishvasmeshram6094 2 ปีที่แล้ว

      69d or 1.5 times lenth whichever is greater

  • @Ravikundalwal
    @Ravikundalwal ปีที่แล้ว

    Span overall h ya effective?????

    • @arun-kumar78
      @arun-kumar78 10 หลายเดือนก่อน +1

      Effective depth bro

    • @valleytoridge9821
      @valleytoridge9821  8 หลายเดือนก่อน

      Effective Span will be safer side