IS Code 456:2000 Specifications for Deflection Control of beam /Deflection control of beam
ฝัง
- เผยแพร่เมื่อ 24 ก.ย. 2021
- Aaj k is video me hum dekhenge ki deflection kya hota h,according to IS Code 456:2000 kisi bhe beam me maximum deflection kitna ho sakta h, Beam k deflection ko contol karne k liye kya kiya jaa sakta h, Deflection of beam ya beam ka deflection span to effective depth ratio par kaise depend karta h,Kisi bhi beam k liye span to effective depth ratio kitna hona chahiye, simply supported beam ke liye span to effective depth ratio kitna hona chahiye,Cantilever beam ke liye span to effective depth ratio kitna hona chahiye,Continious beam ke liye span to effective depth ratio kitna hona chahiye, Reinforcement pr deflection kaise depend karta he, tension reinforcement ke liye modification factor kitna hota he, Compression reinforcement ke liye modification factor kitna hota he,Modification factor kya hota h,
In todays lecture we will study that what is deflection,What should we do to controle the deflection of a beam ,What is the limit of maximum deflection of a beam,What is the limit of maximum deflection of a Simply supported beam,What is the limit of maximum deflection of a Cantiler beam,What is the limit of maximum deflection of a continious beam,what is span to effective depth ratio,what is modification factor
Bahut khub
Best 🎉
Outstanding contribution just carry on
Very well explained 🙏
Thank you 😊
good information, make more videos
Great video sir carry on
Nicely explained sir
well explained..
Tq
👌🏼👌🏼👌🏼
Span is effective or clear span?
When will we take l/350
Baki ka videos banao sir plz🙏
Definitely
More imp video for CE
@8.53 check span / d value. Upto 10m
It was a mistake in summery, kindly ignore it I have explained earlier in this video.
Thanks for you valuable response.
@@valleytoridge9821 wlcm Sir
Kindly check at 8:47
What should i check?
@@foundationtopeak7451 sir you have interchanged the l/d ratio for cantilever and simply supported
Sorry for the mistake and thank you to realiz my mistake.actually at the end it was a summery kindly ignore it.
Sir last me values wrong kr diye ho cantilever or simply supported beam ki..app change kr diye ho ak dusare ki values...pls correct it
Yes dear , sorry for that . last me Jo summary batai usme mujhse mistake ho gyi. Uploaded video me correction mushkil h ,,please consider dear.
Sir contiliver beam span 10m length hai to L D fix column me Kitna Hoga
कंटिलिवर बीम में स्पान 4 मीटर आगे तक है तो उसका एंकर लेंथ LD development , पिछे कालम में कितना जाएगा formula explain करे और मुझे बताइए सर इंटरव्यू में पुछा था
Please reply me sir
Aapka question thik se samjh nhi aaya,please question clear kare mujhe, aap development lenth k liye puch rhe h ya L/D ratio k liye.
69d or 1.5 times lenth whichever is greater
Span overall h ya effective?????
Effective depth bro
Effective Span will be safer side