HRH temp is maintaining less than 540 (ie 530. -532) but RH metal temperature is going to excursion limit, what to do to reduce MTM? Will SOFA and CCOFA help in this?
Sofa ccofa affects sh and rh metal temp but if all the parameters of SH MS crh etc within the range then it can be due to scalling in rh tubes You can manage mtl temp by burner tilt position Shoot blowing Controlled CRH temp On a lower load the sofa can be minimised
great info sir
Thanks and welcome
HRH temp is maintaining less than 540 (ie 530. -532) but RH metal temperature is going to excursion limit, what to do to reduce MTM? Will SOFA and CCOFA help in this?
Sofa ccofa affects sh and rh metal temp but if all the parameters of SH MS crh etc within the range then it can be due to scalling in rh tubes
You can manage mtl temp by burner tilt position
Shoot blowing
Controlled CRH temp
On a lower load the sofa can be minimised
If the opening of SOFA and CCOFA increase, then RH MTM increase or decrease?
Rh mtl temp will rise with more opening of sofa ducts ccofa doesn't effects significantly
Thank you sir
Can u explain SOFA and fire bole angle?
Sir, Can you explain the control scheme of SADC?
Dear sir Mai v 660mw me kam karta hun.aap lightup procedure par video banayye plz...
Mene already bna rakhi hai channel pr dekh skte hai
@@BhagwanSRathore sorry Sir Maine dekha nahin tha..
Dear Sir, Feed water ka flow kahan se lete hai..
@@nasimakhtar8657 flow measurement ka puch rhe ho kya plz explain your qsn
@@BhagwanSRathore yes sir
Please upload videos related to turbine
What in the turbine plz comment your topic
Hello sir how to control Sox formation
Will upload soon
Sir please upload more vedio on regular basis ❤
Sure 👍
❤
❤️🙏