How to pass strong column weak beam check in ETABS Tutorial

แชร์
ฝัง
  • เผยแพร่เมื่อ 5 ก.ค. 2024
  • How to pass strong column weak beam check in ETABS
    Special moment resisting frame design
    SMRF design
    This videos shows the concept of strong column and weak beam.
    ETABS CERTIFIED PROFESSIONAL COURSE FROM BASICS TO ADVANCED LEVEL
    www.udemy.com/course/etabs-rc...
    aci strong column weak beam
    concept of strong column weak beam
    explain strong column weak beam concept
    explain weak beam strong column design philosophy
    how to check beam column capacity ratio in etabs
    how to check column reinforcement in etabs
    how to check deflection of beam in etabs
    how to check strong column weak beam
    how to check strong column weak beam in etabs
    how to strengthen steel columns
    konsep strong column weak beam
    seismic performance of weak-column strong-beam steel moment resisting frames
    strong beam weak column failure
    strong column and weak beam concept
    strong column weak beam
    strong column weak beam aci
    strong column weak beam calculation
    strong column weak beam check
    strong column weak beam concept
    strong column weak beam design
    strong column weak beam example
    special moment resisting frame
    special moment resisting frame concrete
    special moment resisting frame definition
    special moment resisting frame detailing
    Strong column weak beam is very important concept in structural analysis and design. It's desirable to have failure in beam but not in column as it will cause collapse of structural system. You can check this by calculating stiffness of column and beam and taking ratio of that.
    #engineering #etabs #design

ความคิดเห็น • 25

  • @EngineeringLearningPlatform
    @EngineeringLearningPlatform  3 ปีที่แล้ว +6

    Watch, "How to pass strong column weak beam check in ETABS Tutorial"

  • @zahidairfan6161
    @zahidairfan6161 3 ปีที่แล้ว +2

    strong column weak beam check was an awaited tutorial , thanks

  • @laythhasan518
    @laythhasan518 6 หลายเดือนก่อน

    thanks for sharing this video , I would like to ask , is it needed to use modifier 0.25 for slab in slab beam system, I checked ACI-318 - 19 for that and its written that its necessary for flat plates and flat slab

  • @dilipngangom4198
    @dilipngangom4198 2 ปีที่แล้ว

    Does ETABS check the shear strength of Beam-Column joint as per IS:13920-2016 cl.9 over and above Strong column-Weak beam check? How can I verify the check?

  • @civilideas1925
    @civilideas1925 2 ปีที่แล้ว

    👍🏻

  • @Engrwaleed555
    @Engrwaleed555 3 ปีที่แล้ว

    AOA brother. Udemy par ju course ap me upload kia hai us mai detailing ka portion cover kia hai ap ne? I mean complete working drawings ju ham banate hein submission ke leye.

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  3 ปีที่แล้ว

      No, it's an ETABS course primarily, but additionally design aspects are covered and you can check the topics covered on the landing page of course: www.udemy.com/course/etabs-rcc/?referralCode=4F571121E8073D773BE7

  • @gowthamiv4841
    @gowthamiv4841 2 ปีที่แล้ว

    its nice..what about the size of 24" x 24" by increasing column will it feasible to adopt though the member size passed???

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  2 ปีที่แล้ว

      Sorry the question is Unclear. However if a size is passing checks then there would be no reason to increase size

    • @gowthamiv4841
      @gowthamiv4841 2 ปีที่แล้ว

      @@EngineeringLearningPlatform 24" x 24 " size passed once 18"x18" not passed..but adopting of 24 " is feasible for residential??

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  2 ปีที่แล้ว

      @@gowthamiv4841 it is totally dependent on the project I cannot judge that without looking at drawings, it's an Engineer's call and judgement

  • @adrianuslahiwu1002
    @adrianuslahiwu1002 ปีที่แล้ว

    are the wall loads include in mass source ??

  • @zahoorahmadnisar5841
    @zahoorahmadnisar5841 2 ปีที่แล้ว

    Can you please share any technical doc that how etabs calculates it.

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  2 ปีที่แล้ว

      Go to Etabs help menu, click on manuals there you can see list of manuals of different codes, see for your code and the pdf manual will open

  • @andresdavidtorrescarranza1953
    @andresdavidtorrescarranza1953 2 ปีที่แล้ว

    how can i check strong column weak beam if I have a intermediate sway? as We know, Etabs just calculates strong column weak beam for special moment frames.

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  2 ปีที่แล้ว

      Didn't get the question

    • @andresdavidtorrescarranza1953
      @andresdavidtorrescarranza1953 2 ปีที่แล้ว +1

      @@EngineeringLearningPlatform Hi, thank you for aswering me, I mean, when I have a intermediate sway and I want to check 6/5 beam/column capacity ratios OR column/beam capacity ratios I get from Etabs N/A, it happens because Etabs Just calculates these capacity ratios for special frame moments, so as I mention before, I have a intermediate sway and I want to do these Checks. How can I check 6/5 beam/column capacity ratio in an intermediate sway?. In this video you are working whit a special frame moment so you can check 6/5 beam/column capacity ratio.

  • @rcbsht9644
    @rcbsht9644 ปีที่แล้ว

    can you explain the color of column it displays as red pink and sometimes as black

  • @dibesshrestha796
    @dibesshrestha796 3 ปีที่แล้ว

    What does N/A mean in c/b capacity ratio

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  3 ปีที่แล้ว

      Mostly arises when the beam is not assigned "beam property" happens by mistake, or if the joint is not properly forming at common node or even releases can cause this issue.

    • @4ta01_josuadmarthrietchyri7
      @4ta01_josuadmarthrietchyri7 11 หลายเดือนก่อน

      @@EngineeringLearningPlatform How ti fixed it? please answer.

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  11 หลายเดือนก่อน

      @@4ta01_josuadmarthrietchyri7 select the members, go to design and then "overwrite the frame design procedure" to correct one. If concrete so concrete or steel so steel

  • @zulkarnainbinmohdsalleh2024
    @zulkarnainbinmohdsalleh2024 4 หลายเดือนก่อน

    Confused…