  • @jessegarcia7383
    @jessegarcia7383 6 หลายเดือนก่อน +5

    Man I can’t Thank You Enough, I’m in Houston and we just got hit by a hurricane. And we are without power, I went to Lowe’s also this morning 7-10-24 picked up the exact same generator and it happened on the 1st day. I saw your video and did exactly what you said and wala it’s running. Once again Thank You!!!

    • @EastTexasHomestead
      @EastTexasHomestead  6 หลายเดือนก่อน +2

      What a shame! Generac has got to fix this. You’re the third person today with the exact same story. This so-called safety feature is going to kill someone. But I’m glad this was helpful and you were able to get it fixed. Great job taking care of things! We are just north of you and I’ve only had to deal with a few small power outages. Check into some of our videos on off grid solar so you can be ready next time. Stay safe down there.

    • @h-townlifestyle9105
      @h-townlifestyle9105 6 หลายเดือนก่อน +1

      This is day 4 whit out power
      I have the exact same one. From home depot And did the same problem just now

    • @EastTexasHomestead
      @EastTexasHomestead  6 หลายเดือนก่อน

      @@h-townlifestyle9105 Sorry to hear that. Were you able to fix it?

  • @THEMOWERMEDIC1
    @THEMOWERMEDIC1 2 ปีที่แล้ว +2

    I’ve had a few Chinesium clone gp6500 gensets in the shop with the same issue. Thanks for posting!

    • @EastTexasHomestead
      @EastTexasHomestead  2 ปีที่แล้ว +2

      It's interesting that the clones had the same Issue

  • @skykingjts
    @skykingjts หลายเดือนก่อน

    Brother. I have to admit,, you saved me and the family from freezing and loosing all the frozen food ext. Bless you and your family.. much respect.. Skyling

    • @EastTexasHomestead
      @EastTexasHomestead  หลายเดือนก่อน

      So glad to hear that. I still can't believe there's no class action suit against Generac for putting people in this situation. Stay warm!

  • @jeffradford1
    @jeffradford1 3 หลายเดือนก่อน

    I want to thank you for showing me how to easily fix my generac with the same issue. It took me 20 minutes doing it exactly like you did and it works perfectly!! Thanks again!!

    • @EastTexasHomestead
      @EastTexasHomestead  3 หลายเดือนก่อน +1

      Great to hear! Just be careful where you place it now 😣

  • @vazquezsantos4
    @vazquezsantos4 ปีที่แล้ว +2

    Thxs my guy this actually helped me 💯% pretty much same thing happened just a a different piece inside the box was broken but I was able to by pass it and now it’s working like new! Thxs a million

  • @deniseandmarkfirestine7443
    @deniseandmarkfirestine7443 ปีที่แล้ว +3

    I just bought the same one, thanks for the heads - up on how to fix the issue on the genejunk!!

    • @EastTexasHomestead
      @EastTexasHomestead  ปีที่แล้ว

      It could save your life! Ok, maybe that’s a bit dramatic, but it’s a huge pain when this thing goes out when you are depending on it.

  • @ThePirate045
    @ThePirate045 6 หลายเดือนก่อน

    We got this generator and had the same issue. We lost power in Houston and your video saved us thanks!

    • @EastTexasHomestead
      @EastTexasHomestead  6 หลายเดือนก่อน

      Glad it helped. Sorry Generac is still selling such a bad product.

  • @nater6604
    @nater6604 ปีที่แล้ว +3

    Thanks a bunch for making this video. I have the same exact generator I bought like 2 years ago because of a snow storm. The generator sat in my garage ever since never even put fuel in it. Tried to run it today to power my welder for the first time and nothing. Made a couple of connectors taped up the empty leads and it worked perfect. 😎👍

    • @EastTexasHomestead
      @EastTexasHomestead  11 หลายเดือนก่อน

      I’m glad it worked for you! It’s a shame a good brand is shipping out trash and not standing by the product.

  • @whitesabre9974
    @whitesabre9974 6 หลายเดือนก่อน

    Thank you so much for posting this fix. Purchased mine this morning due to hurricane Beryl. Ran two hours and stopped. COnon-sense!

    • @disorderlymovement
      @disorderlymovement 6 หลายเดือนก่อน

      I'm in same boat. 59 hours on mine. Same issues as this, but not sure I want to take apart and void warranty. Yet, my 88 degree interior of home disagrees and says DO IT! Have you tried this yet? Curious if it fixed your issue?

    • @whitesabre9974
      @whitesabre9974 6 หลายเดือนก่อน

      @disorderlymovement Haven't tried yet. We reduced the load on the generator and are managing with only one window unit. In addition to dealing with the results of Beryl, our entire family is really sick.
      So far reducing the load has helped...we will see.

    • @disorderlymovement
      @disorderlymovement 6 หลายเดือนก่อน +1

      @@whitesabre9974 Thank you for the response. I did go through with the work after some reluctance. Yet, only to the point of removing the "control unit"/board. My capacitor was still in place. Yet, with removing the board, the generator is running great. Has gone for a solid 6 hours now with no issues. The on/off switch does not work, but I can carefully pull the spark plug wire or just starve it of fuel when I decide to shut it off. Hope you are able to get yours working 100%. Again, truly appreciate your response and wishing you restored power very soon. Let's hope that is the last storm for Houston for the season.

    • @EastTexasHomestead
      @EastTexasHomestead  6 หลายเดือนก่อน +1

      I’m glad you had success getting power! Now let’s hope you get grid power back up soon.

  • @JamesWebb-i4w
    @JamesWebb-i4w 7 หลายเดือนก่อน

    Thank you very much for showing how to fix this problem. I have the same generator, with the same problem. I thought it was a fuel problem. I changed the carburetor, and it still shut off. Followed your directions and it fixed it. Thank you very much for the help !!

  • @danswelding9058
    @danswelding9058 3 หลายเดือนก่อน

    Awesome somebody gave me this generator and I seen it all taken apart. I think that’s what they were trying to fix. Very helpful. Thanks.

  • @melanierazo5901
    @melanierazo5901 6 หลายเดือนก่อน

    Man thank you for this video! Day 6 of no electricity, we bought this 2 days ago only ran for 4 hours and it turned off. This has helped my dad fix the issue thank you 😢😢😢😢

    • @EastTexasHomestead
      @EastTexasHomestead  6 หลายเดือนก่อน

      That's so frustrating. I'm glad he was able to get it fixed. Do y'all have power back on yet?

  • @ashleywehrlen6353
    @ashleywehrlen6353 3 หลายเดือนก่อน

    So i did exactly what your video shows to do. It now runs which fixed that issue but my question is do you need to plug the plug back into the board after wiring the two black wires together. When testing it I now ha e cane across another issue of not producing power out the outlets. Would that be because I have to plug that wire back into the board because I just left it unplugged...what do you think?

    • @EastTexasHomestead
      @EastTexasHomestead  3 หลายเดือนก่อน

      Be sure to check the circuit breaker. That one gets me sometimes.

  • @speakinechos
    @speakinechos ปีที่แล้ว +1

    What is the part number for a new part to replace this if it breaks rather than just bypassing it

    • @sondrad101
      @sondrad101 ปีที่แล้ว +2

      I have the same issue and I called Generac. They told me that the new part # is 10000032946 for $359.99 which is a rip off: especially, since it's evidently a frequent issue.

    • @patriciocampuzano4522
      @patriciocampuzano4522 ปีที่แล้ว

      He’ll no

    • @EastTexasHomestead
      @EastTexasHomestead  ปีที่แล้ว

      Wow! Instead of recalling a bad design, they want to charge half the price of the generator for us to fix it?

  • @chelsw9764
    @chelsw9764 8 หลายเดือนก่อน

    You are an absolute life savor!! Issue is fixed now the piece was different but who cares, my $1200 machine is not junk anymore n that's great!!!

  • @jhpfmj
    @jhpfmj 2 ปีที่แล้ว

    I can't believe that I just found your channel. Also just bought that security torx set per your link. I didnt have the security set.

    • @EastTexasHomestead
      @EastTexasHomestead  2 ปีที่แล้ว +1

      Thanks for using the link! Did you have the COsense issue too?

    • @jhpfmj
      @jhpfmj 2 ปีที่แล้ว

      @@EastTexasHomestead No, Sir. I Have a much cheaper piece of junk. I was watching random generator repair vids and this one popped up.

  • @celicablues
    @celicablues 5 หลายเดือนก่อน +2

    Just in case you read this. I made the comment to someone else's, but the yellow wire is the low oil cutoff switch. I think youve bypassed that. So you should probably disclaimer thay for those who wouldnt ever check their oil.

    • @57haldir
      @57haldir 4 หลายเดือนก่อน +1

      Could he/we just cut the yellow wire?
      Also, If he splices the blacks and plugs it back into the motherboard I don’t think it bypasses the low oil cutoff. Agree?

  • @philliphall5198
    @philliphall5198 ปีที่แล้ว

    Thank You’ll for information and advice
    Good to know how to fix it and no more trouble

  • @mariojesus593
    @mariojesus593 หลายเดือนก่อน

    I fixed 😅. Thank-you very much i glad to find you video.

  • @DanHudnall-x7h
    @DanHudnall-x7h หลายเดือนก่อน

    Tried to bypass the cosense using this guide on xt8500efi. It will not start with the sensor unplugged. With the black wires tied together, it runs about 20 seconds and shuts down. The sensor for the efi units appears to have an efi specific pn. Any ideas on eliminating the sensor on the efi units?

  • @rpfl5586
    @rpfl5586 11 หลายเดือนก่อน

    Couldnt youjust cut the 2 black wires and wire nut them together? Great video. Thank you

    • @57haldir
      @57haldir 4 หลายเดือนก่อน

      Yes. And I think if you then plug it back into the mother board you don’t by pass the low oil cutoff.

    • @freyinnovations
      @freyinnovations 3 หลายเดือนก่อน

      Don't even have to cut the wires if you use a Tap Splice.

  • @RolandoGuevara-qe7sr
    @RolandoGuevara-qe7sr ปีที่แล้ว

    Very nice thank you for this video it helped me out a lot

  • @mehoff88
    @mehoff88 5 หลายเดือนก่อน

    Mine only has three wires a red, yellow, and black wire. Which ones do I tie together?

  • @roncyrier
    @roncyrier ปีที่แล้ว

    amazing! Thanks. That was very good advice.... and just in time. I was just about to go buy a Honda generator for 900 bucks! so nice. We are in a hot climate too in Baja California Sur so I like your theory. Oddly my little blue transistor was fine, but the little square one was wiggly. Dumb stuff.

    • @EastTexasHomestead
      @EastTexasHomestead  ปีที่แล้ว

      Glad it helped!

    • @marktomlinson3448
      @marktomlinson3448 ปีที่แล้ว

      That blue thing is an electrolytic capacitor. It is easy to obtain another new one with the full leads, and solder it through the holes on the board. You have to install it with the correct polarity though, which you might be able to figure out by comparing with how the similar smaller ones are installed.

  • @jasonflyte3175
    @jasonflyte3175 6 หลายเดือนก่อน

    Thank you! This saved me big time!

  • @freyinnovations
    @freyinnovations 3 หลายเดือนก่อน +1

    A way easier, safer, and cleaner way to jump the black wires is to just use a Tap Splice connector somewhere along the bundle of 4 wires.

    • @EastTexasHomestead
      @EastTexasHomestead  3 หลายเดือนก่อน

      That does sound easier ☺️

    • @freyinnovations
      @freyinnovations 3 หลายเดือนก่อน +1

      @@EastTexasHomestead And if you ever decide to replace the CO sensor unit, you can just take the Tap Splice off, and your back to stock.

  • @protechmachinery1
    @protechmachinery1 ปีที่แล้ว

    I have the same unit but won't start at all. Nothing when I pull. It was working one moment. Turned off. Topped with gas. Tried to turn back on. Nothing. Ran it for one storm. Then for 2 hours on the next storm. And that's it. Less than 50 hours. I'll check the cosense module but it's a different issue. Mine won't start at all compared to yours flashing and then stopping. Mines not flashing at all.
    Trying to think what the issue could be on a nearly new unit like yours.

    • @Darjan_Spasojevic
      @Darjan_Spasojevic ปีที่แล้ว

      Try spraying ether to see if it will start. Might just need a carb clean and new fuel.

    • @marktomlinson3448
      @marktomlinson3448 ปีที่แล้ว

      Disconnect the oil sensor switch and try it. If it runs, you either have too low oil or you need a new switch. This is a common problem with lots of equipment. The oil switch is in the same stop circuit as those 2 black wires. the switch shorts the wire to ground when it thinks that the oil is low, and that prevents the engine from running.

  • @sondrad101
    @sondrad101 ปีที่แล้ว

    Sir, I did everything in your video: my generac gp6500 starts and turns off just fine now. The conundrum is that now that I did everything that you shared, step by step, my generator no longer provides power or electricity. By chance did you encounter this and if so will you please share the resolution so that my gen provide electricity again? Thank you in advance and standing by for your convenience. 🙏🏼🙇🏻‍♀️

    • @EastTexasHomestead
      @EastTexasHomestead  ปีที่แล้ว

      That’s so strange. I haven’t had that issue, but maybe someone else has and will be able to give direction.

    • @daltongriffin1700
      @daltongriffin1700 5 หลายเดือนก่อน

      Did you ever figure it out? I’m having the same issue after the bypass

    • @57haldir
      @57haldir 4 หลายเดือนก่อน

      Try instead just jumping the black wires then plug the harness back into the mother board.

  • @jepcozenith40
    @jepcozenith40 2 ปีที่แล้ว

    Yeah, looking a the stills in the video. You can see on the PCB that the gold is showing around the holes where the cap was. Now, look at the connector on the PCB. Solder flows up the leads. That is how the solder should have flowed up the leads of the cap.

    • @EastTexasHomestead
      @EastTexasHomestead  2 ปีที่แล้ว +1

      It may have been easier to simply solder the thing back on. I’ve just never attempted it.

    • @jepcozenith40
      @jepcozenith40 2 ปีที่แล้ว

      @@EastTexasHomestead regardless, it is working. Not gonna run the gene in the house anyway.

  • @kckoellein
    @kckoellein 2 หลายเดือนก่อน

    kills me cuz its so easy to just solder on a new capacitor and hot glue it down so it doesnt vibrate... not too hard to get some skills to do that. couple videos and maybe $30 for an iron and stuff. but hey! Your fix works. so thanks for posting!

  • @hugoaguilar7060
    @hugoaguilar7060 6 หลายเดือนก่อน

    I just bought mine yesterday and had it on all and it has the same problem thanks

    • @EastTexasHomestead
      @EastTexasHomestead  6 หลายเดือนก่อน

      Sorry to hear that. Generac really needs to get this figured out

  • @geechiesghost8118
    @geechiesghost8118 4 หลายเดือนก่อน

    I didn’t destroy the pc board, but I did directly connect the two black wires. It works great now.
    The little white box on my pc board came loose. Generator (GP6500) runs now and supplies electricity.
    Just pull the 2 black wires out of the connector, tape them together, and connect back for the others to work.
    Yellow light does blink constantly now.

    • @EastTexasHomestead
      @EastTexasHomestead  3 หลายเดือนก่อน

      Good to know. If I get to repair another one I’ll try this first.

  • @justinweber7547
    @justinweber7547 6 หลายเดือนก่อน

    Bro you are awesome I have a different board but the same problem. My red was labeled 120v green was ground and one black was ignition coil and the other ignition switch. Pull the box and it works but dont shut down but thats no issue because I generally cut the fuel and let it drain the carb.

    • @EastTexasHomestead
      @EastTexasHomestead  6 หลายเดือนก่อน

      Glad it helped and thanks for sharing!

    • @elviraraff6809
      @elviraraff6809 3 หลายเดือนก่อน

      On my Predator 9000 I just cut the coil wire and shut it down by turning off the fuel or to shut it quickly just apply full choke.

  • @rpfl5586
    @rpfl5586 11 หลายเดือนก่อน

    Took mine out and now it runs great again but doesnt produce power? Any ideas? Thanks

    • @EastTexasHomestead
      @EastTexasHomestead  11 หลายเดือนก่อน

      @rpfl5586 Be sure your 30 amp AC Breaker is turned on. That's about the only thing I can think of. I just used mine again this weekend, and it works great.

  • @jessegarcia7383
    @jessegarcia7383 6 หลายเดือนก่อน

    Will do and Thank You once again

  • @joshm3342
    @joshm3342 7 วันที่ผ่านมา

    I would have soldered the capacitor back onto the circuit board (and glued it down). My two older generators don't have CO protection, but I have been using small engines all my life, and I know to stay well away from enclosed areas. When I run the generator, it is 25 feet away from the house, with the exhaust pointed out toward the back fence.

  • @coyotesden
    @coyotesden 2 ปีที่แล้ว

    I have had to do this to 3 Dewalt generators all using the same Generac COSense garbage over the last year or so. I said f it and just cut the black wires and crimped them together. None of mine were the Capacitor, all of them had water corrosion on the board shorting them out, the conformal coating was not complete on any of them and that is the spots that corroded.

    • @EastTexasHomestead
      @EastTexasHomestead  2 ปีที่แล้ว +1

      you would think they would either fix the problem or stop using the faulty safety product. I guess it just looks too good in the marketing.

  • @GZEPOL-gr2ml
    @GZEPOL-gr2ml 6 หลายเดือนก่อน

    I just bought mine this afternoon and it started and runs but produces not Energy! Why, help! 🤷🏻

    • @EastTexasHomestead
      @EastTexasHomestead  6 หลายเดือนก่อน

      Be sure to check the breaker on the far right. See here: th-cam.com/video/B2tUbTsg2hY/w-d-xo.htmlsi=kdy085cJ73c769oS&t=204

  • @mazensholakh9529
    @mazensholakh9529 6 หลายเดือนก่อน

    Was having the same issue of the generator turning off. I removed the CO sense and it’s working fine, but now I don’t have ac power

    • @EastTexasHomestead
      @EastTexasHomestead  6 หลายเดือนก่อน

      Check to make sure the breaker on the far right of the plugs is flipped on.

    • @mazensholakh9529
      @mazensholakh9529 6 หลายเดือนก่อน

      @@EastTexasHomestead it is :/
      Not sure if there’s another issue now

    • @EastTexasHomestead
      @EastTexasHomestead  6 หลายเดือนก่อน

      I’m really not sure. I’ve had others say this after “fixing it” but don’t know why. Maybe double check the wiring. Did everything look the same as mine or was it a different wiring configuration?

  • @scottepps7647
    @scottepps7647 3 หลายเดือนก่อน

    Good info. I would feel better ordering a new capacitor online from just about any electronics warehouse and solder the new part and clip the leads...but i agree, its a total failure of quality control at Generac.

    • @scottepps7647
      @scottepps7647 3 หลายเดือนก่อน

      Also...the Cap is only $1.25 on Amazon.

    • @EastTexasHomestead
      @EastTexasHomestead  3 หลายเดือนก่อน

      I’m better at cutting wires than soldering 😝

    • @stargazer7644
      @stargazer7644 3 หลายเดือนก่อน

      Secure the cap with silastic or the vibration will just rip it off again.

    • @elviraraff6809
      @elviraraff6809 3 หลายเดือนก่อน

      I agree with you. Buy the cap and find a friend to solder it in.

  • @BlueCollarGaming11
    @BlueCollarGaming11 24 วันที่ผ่านมา

    Hoping maybe through comments or whatnot you’ve experienced this. Brand new, do all the start up, runs about 2-3 minutes then shuts off. Watch your video, remove the sensor, everything’s intact, but now the generator doesn’t shut off. Super sensitive sensor?

    • @EastTexasHomestead
      @EastTexasHomestead  24 วันที่ผ่านมา

      That’s frustrating. Check all your ground connections.

  • @r.romberg8312
    @r.romberg8312 ปีที่แล้ว +1

    Have you had an issue of it running, but not delivering power?

    • @sondrad101
      @sondrad101 ปีที่แล้ว

      I asked him the very same thing because after following his steps I lost electricity but got no resolve from him 🤦🏻‍♀️🤷🏻‍♀️

  • @KevinAndErica
    @KevinAndErica 9 หลายเดือนก่อน

    Great job brother 💯🫡

  • @Aleamae_Mokae
    @Aleamae_Mokae 3 หลายเดือนก่อน

    Mahalo brotha!!!!🤙🏽🤙🏽

  • @JJVargas4u2c
    @JJVargas4u2c 4 หลายเดือนก่อน

    I put it back in the case it came to Cove the plug. Thanks

  • @donalddday7741
    @donalddday7741 หลายเดือนก่อน

    so have done what they say to bypass co on newish champion 2500 nothin works so gonna pull engine toss the rest and replace my 5 year old Champion 2500 engine when it dies for good as its almost done for

  • @jepcozenith40
    @jepcozenith40 2 ปีที่แล้ว +1

    Yes, that is an electrolytic capacitor. Depending on the solder it could start melting at 190F. Most at 800F(ish). Hopefully, that is not Texas hot. Looks like a cold solder joint. That is where the solder did not properly flow on the leads of the cap. So the cap is just touching the solder instead of adhering to it. Over time it fails. Falling off. Probably lead-free solder and poor quality control.

    • @EastTexasHomestead
      @EastTexasHomestead  2 ปีที่แล้ว +1

      😆 It gets pretty hot but not 800 degrees hot.

    • @freyinnovations
      @freyinnovations 3 หลายเดือนก่อน

      So could you just re-solder it?

    • @stargazer7644
      @stargazer7644 3 หลายเดือนก่อน

      That is not why the cap came off. And solder does not melt at 190F.

  • @stargazer7644
    @stargazer7644 3 หลายเดือนก่อน

    All you had to do is replace the cap and secure it with silastic to stop vibration from ripping the cap off.

  • @sammycroslin4656
    @sammycroslin4656 หลายเดือนก่อน

    I have a 5600 an it started running 30 sec an dying. No lights . That I have seen . Everything is full.

    • @EastTexasHomestead
      @EastTexasHomestead  หลายเดือนก่อน

      Check all your ground connections to be sure a wire hasn't wiggled losse

  • @57haldir
    @57haldir 4 หลายเดือนก่อน

    Has anyone tried just cutting the yellow wire?
    Also, I’m wondering if initially unscrewing it from the frame and suspending it from a string or heavy rubber band might minimize the vibration and alleviate the problem?
    Yes it’s a defect and a bummer but for now we need options.
    No one is coming to save us.

  • @georgewillingham3687
    @georgewillingham3687 3 หลายเดือนก่อน

    Check oil level, low oil cut off.

    • @EastTexasHomestead
      @EastTexasHomestead  3 หลายเดือนก่อน

      That’s always a great starting point. In this case, my oil was fine.

  • @jefflanham1080
    @jefflanham1080 7 หลายเดือนก่อน +5

    I’ve got the same exact generator……..12 hours same friggin problem, PISSES ME OFF! I’m gonna bypass because at $115.00 for the part, it will probably go bad AGAIN!! Damn I paid good $$$ to have a generator OF QUALITY!!! In the year 2024 if you don’t know about carbon monoxide…….you probably don’t deserve to live anyway!!

    • @EastTexasHomestead
      @EastTexasHomestead  7 หลายเดือนก่อน

      I’m not sure why they don’t have a recall on this yet

    • @felixgazmey9647
      @felixgazmey9647 6 หลายเดือนก่อน +1

      I appreciate the video, but wouldn't it have been simpler just to resolder the capacitor back on. seam better than risking a sock and pulling out the multimeter. Just pull out the soldering iron and be done in ten minutes lol just my smart ass two cent lol

    • @celicablues
      @celicablues 5 หลายเดือนก่อน

      ​@@felixgazmey9647
      Because it's a useless safety feature. It's for people that will run this in their garage with the door closed. Or even inside their home.

    • @celicablues
      @celicablues 5 หลายเดือนก่อน

      Also, I work on these every day right now. Florida. And they are brand new, lots of them, hardly any hours on them.

    • @celicablues
      @celicablues 5 หลายเดือนก่อน

      One more thing, the yellow wire is for the low oil pressure switch, so you've effectively bypassed that. I might need to check the wiring diagram again to confirm that though.

  • @timm1065
    @timm1065 8 หลายเดือนก่อน

    Should have just cut the top two prongs off the board and put it all back together. Seems it would have worked still.

  • @johnseavey6622
    @johnseavey6622 ปีที่แล้ว

    Good luck with staying together without being soldered

  • @orlypalomar
    @orlypalomar ปีที่แล้ว

    So close... using an RPG to take out a bee. It was a potentially easy and cheap repair with the decapitated capacitor, IMHO. I guess the root cause of the failure is that whoever made that module, didn't care to secure the electronic components in glue or potty. Generators produce a lot of vibration and is the main reason why electronic components that are left "flapping in the wind" will eventually work its way out of the circuit board... one way or the other. People going this route ought to check local state laws on circumventing or disabling safety devices on generators. Nevertheless, I enjoyed the video.

    • @freyinnovations
      @freyinnovations 3 หลายเดือนก่อน

      Would it make sense to proactively glue/pot the capacitor to prevent it from vibrating loose?

    • @orlypalomar
      @orlypalomar 3 หลายเดือนก่อน

      @@freyinnovations That would be a good idea. I have used hot melt glue to secure large capacitors. But I made sure the components never got hot enough to reach the melting point of the glue. There are better ways to do it but I'm not really familiar with the exact compound they use.

    • @freyinnovations
      @freyinnovations 3 หลายเดือนก่อน

      @@orlypalomar Yeah, I wouldn't use hot melt glue for this application (I've done that for others), but I would think a good silicone adhesive would do the trick.

  • @Falconsfight
    @Falconsfight 2 ปีที่แล้ว

    I liked the video, but my only problem is where you had your generator. It should be atleast 10 feet away from any structure. This is to help in case your generator should short out or catch fire. Muchless to reduce the risk of carbon monoxide poisoning.

    • @EastTexasHomestead
      @EastTexasHomestead  2 ปีที่แล้ว +2

      In a perfect world, that would be great. How do you run your generator out in the middle of your yard in the middle of a storm? I run mine on the covered porch of my barn, which is at least 10 feet from the door. It's >50ft from my home, where I would be using it.

    • @Falconsfight
      @Falconsfight 2 ปีที่แล้ว

      @@EastTexasHomestead True, but I have a Gentent canopy to protect my Generac RS8000E. There are methods to protect your generator from the elements from building PVC/ tarp configurations to making a generator shed. My unit is about 20ft from the house and secured with a heavy duty chain. The first thing stolen in a disaster are generators.

    • @freyinnovations
      @freyinnovations 3 หลายเดือนก่อน

      Thanks Mommy

  • @sailmirage
    @sailmirage 3 หลายเดือนก่อน

    Solder the cap back in place. Hot glue around components.

  • @patrickteich8628
    @patrickteich8628 หลายเดือนก่อน

    Figures, did just like you did. Now starts, runs and turns off. No power to outlets, smh.

    • @EastTexasHomestead
      @EastTexasHomestead  หลายเดือนก่อน

      @@patrickteich8628 check the ac breaker

  • @rlowe3
    @rlowe3 ปีที่แล้ว +2

    To shut down, just shutoff the fuel.

  • @lysanconstructionllc300
    @lysanconstructionllc300 11 หลายเดือนก่อน

    gracias a este video me ahorre 800 usd

  • @michaelmcmillan4263
    @michaelmcmillan4263 หลายเดือนก่อน

    Why not cut them,butt splice them togeather ??????

  • @hexdookhay3369
    @hexdookhay3369 5 วันที่ผ่านมา

    These gens seem to be the suckiest , bought one used it once and then it wouldn’t turn on . Managed to get it up and running, But it got heavily rusted under the gas cap and other areas even though it was kept in a garage …

  • @roel209ful
    @roel209ful 4 หลายเดือนก่อน

    The choke close it lol

  • @jefflanham1080
    @jefflanham1080 7 หลายเดือนก่อน

    ……I miss Radio Shack…..at least then I could fix it a little more professional.

  • @donalddday7741
    @donalddday7741 2 หลายเดือนก่อน

    why is it that no one is putting on how to bypass a champion 2500 that really works, cause ive sone 3 that dont work pulling black wire, completely covering the sensor, bridging wires none work my 6 month old generator has never run over a few minutes and i got it 6/24 did not start it till 8/24 so basically could not send ot back to amazon

  • @michaelanger1392
    @michaelanger1392 ปีที่แล้ว +1

    I think the reason why you have that board is in case you have carbon monoxide and it shuts off the generator

  • @stevebost8048
    @stevebost8048 4 หลายเดือนก่อน

    Thanks for sharing I'll make sure I don't buy a generator with this function

  • @johncoffman2703
    @johncoffman2703 5 หลายเดือนก่อน

    Thanks. I had mine run for 20 hours then had the same problem. I took it to the service center and said it was a bad spark plug. paid 74 dollars. I got it home and same problem. Called them back and wanted me to bring it back. So there sorry assed junk. Should sue since this is a safety issue a family could have died. I use my carbon monoxide unit anyway.