Part 1: BS 6399 Wind Load Example (Introduction)

แชร์
ฝัง
  • เผยแพร่เมื่อ 2 พ.ค. 2020
  • Here is an example of a wind load calculation as per BS 6399-2.
    This part 1 gives an overall introduction.

ความคิดเห็น • 20

  • @leontheik669
    @leontheik669 3 ปีที่แล้ว +2

    You make us always reduce the freight and stress on the subject by saying "it is not difficult, it is very very easy", etc. It is so wonderful teaching and special benevolence to students! thank you so much....

  • @alialkhaldi90
    @alialkhaldi90 2 ปีที่แล้ว

    هلا عبدالله ، اليوم اكمل ثاني اسبوع دوام في ارامكو السعوديه اكبر شركه بالعالم جاتني اول case اليوم وكنت سعيد جدا بس للاسف نسيت كيف احسب wind load كتبت خذيت كتاب structure analysis ومافهمت كم حاجه وفتحت اليوتيوب ولقيت مقطعك و فهمت كل شيء ، الموضوع كان شخصي بالنسبه لي لانها اول task يجيني . شكرا لك و كتب الله اجرك و دعيت لك من قلبي ❤️

  • @martinm9813
    @martinm9813 2 ปีที่แล้ว

    Excellent work....very informative!

  • @abrahamgeresu5557
    @abrahamgeresu5557 2 ปีที่แล้ว

    Please add another videos of wind load patterns in all direction (if wind ward is in x ,-ve x,y and +y )on sap or etabs because you're presentations and accent are clear and interesting

  • @nwanneorekyeh239
    @nwanneorekyeh239 3 ปีที่แล้ว

    Thanks for this.

  • @mimozi5237
    @mimozi5237 2 ปีที่แล้ว

    Very helpful thank you so much

  • @SO-th8gc
    @SO-th8gc 3 ปีที่แล้ว +1

    Bro...love the video!! And thanks for doing it in English 😃

  • @fahadyaqoob4332
    @fahadyaqoob4332 3 ปีที่แล้ว

    Can you please tell me, in which case we use unclad frame for kb factor?

  • @rahmanrahmani2896
    @rahmanrahmani2896 4 ปีที่แล้ว +2

    Excellent presentation. BS6399 is superseded by EC1 - Part4. Therefore, it would have been very helpful if you have used Euro-Codes instead of BS. Since June 2010 it is compulsory to use EC for all new structures unless you have departure from the clients NOT to use it. BS are still valid for assessment work! Thank you

    • @abdullahalmahruqi1976
      @abdullahalmahruqi1976  4 ปีที่แล้ว +3

      It's because here we are still using BS 6399-2. It's is yet a good practice, all have the almost the same principles.

    • @michaelacheampong2869
      @michaelacheampong2869 3 ปีที่แล้ว

      @@abdullahalmahruqi1976 We still using it so it is very welcome

  • @drsnomr
    @drsnomr ปีที่แล้ว

    what if there are openings at both sides instead of just one ?

  • @s.c.1903
    @s.c.1903 3 ปีที่แล้ว

    What about wind in oblique directions?

  • @MOHAMED-ADEN
    @MOHAMED-ADEN 20 วันที่ผ่านมา

    Length=47.5m?

  • @keshavgopaul5491
    @keshavgopaul5491 2 ปีที่แล้ว

    Thank you sir, please tell me from which book is this example taken from?

  • @mohammadanasbeg5000
    @mohammadanasbeg5000 2 ปีที่แล้ว

    wa-Alykum Assalam

  • @himodesweet6726
    @himodesweet6726 4 ปีที่แล้ว

    uعاشت ايدك الف شكر لو فيك تحكي عربي

    • @abdullahalmahruqi1976
      @abdullahalmahruqi1976  4 ปีที่แล้ว +1

      بحاول ن شاء الله اعمل نسخة بالعربي