DIY install of air conditioner soft-start (Micro-Air Easy Start Flex) - so much quieter!

แชร์
ฝัง
  • เผยแพร่เมื่อ 6 ม.ค. 2025
  • In which I install the Micro-Air Easy Start FLEX into the condenser unit of our central AC system. The condenser makes an obnoxious loud noise when starting up, due to the high inrush current, and even causes the lights in the house to flicker. After installing the soft-starter, the compressor is sooo much quieter when starting up, and the light flickering is completely gone.
    The usual disclaimer: do NOT attempt to do this if you are not completely comfortable working with household electrical components. 240V is no joke. This video is for entertainment purposes only, and is simply to document my experience installing this device on my particular AC unit, and is not intended as a recommendation for you to install it on yours. I assume no liability for any damage or injury resulting from any equipment, tools, or procedures in this video. Always use proper safety procedures, and hire professionals when needed. Attempt any projects and repairs at your own risk.

ความคิดเห็น •

  • @SandlGetIt
    @SandlGetIt 2 วันที่ผ่านมา

    Nothin gets me going like a clean install. The fact that the box fits inside to cover plate is a huge selling point in my book.

  • @adammorton9311
    @adammorton9311 5 หลายเดือนก่อน +17

    I have watched several of these micro air install videos as I plan to install the same flex this week. With that, I have to say you made a fantastic video and I appreciate the effort involved. I laughed out loud at the blackout after the install.

  • @PaulBailey3
    @PaulBailey3 5 หลายเดือนก่อน +35

    I installed an older version on my home AC and my RV. They are wonderful devices. I can't believe this is not built into AC units already.

  • @Channel-5766
    @Channel-5766 5 หลายเดือนก่อน +6

    I have seen a lot of videos on how to install the soft-start and this video is the best, simple, direct and without beating around the bush. I think even my grandmother can install one. Thanks, now I am encouraged to install my soft-start, especially the "Flex" model.

  • @thepiecesfit5049
    @thepiecesfit5049 4 หลายเดือนก่อน +7

    Think I'm going to go steal the Hutch Mountain wiring approach. Blue female spade disconnects for orange and black, then Wago 221 splicing connectors for the white and brown wires. This way you can splice into the existing wires leaving the original connection, and should the Micro-Air fail you can have a running AC again in relatively short order without having to redo the termination on the wires.

  • @hosshimer
    @hosshimer หลายเดือนก่อน

    Used your video to install an easy start to my American Standard 5 ton. Works great, thanks!

  • @SummitFarm
    @SummitFarm 6 หลายเดือนก่อน +5

    No longer wakes me up when the compressor turns on! I think it's great.

  • @CarlosTorres-nd9lw
    @CarlosTorres-nd9lw 4 หลายเดือนก่อน +3

    Hi, Dmitry excellent job I just ordered my Micro-Air Easy Start Flex, I've watched your video quite a few times Thank You ...Carlos

  • @Captainpaulbtyhtr
    @Captainpaulbtyhtr 2 หลายเดือนก่อน

    Just got mine , installing this week ! Perfect timing for Flex install , Yhx !

  • @mh2378g
    @mh2378g 4 หลายเดือนก่อน +2

    Nice Job on this video- very clear, and had the info I need to upgrade my 2 ton unit. I particularly like the before and after startup sound level comparison!

  • @harveypaxton1232
    @harveypaxton1232 5 หลายเดือนก่อน +11

    Thanks for the great video. If your lights were flickering you should start from the breaker in the panel. Pull the breaker and check the buss bar and the breaker where it snaps onto the buss bar. then make sure the wires are properly torqued. Then the disconnect at the condenser and finally the connections in the condenser. They all seem to loosen over time. The Soft Start is a great way to make your unit last longer.

    • @co7366
      @co7366 5 หลายเดือนก่อน +3

      Good point for some great troubleshooting. Thanks for your input

    • @harveypaxton1232
      @harveypaxton1232 5 หลายเดือนก่อน

      @@RadioRich100 are you speaking about a soft start?

    • @harveypaxton1232
      @harveypaxton1232 5 หลายเดือนก่อน +1

      @@RadioRich100 Variable Frequency Drives (VFD) have been running equipment for over forty years. All the new systems that are “inverters” are soft start. They allow the compressor to ramp up to speed unlike getting hammer by across the line starting (contactor). The running current is the same.

    • @co7366
      @co7366 5 หลายเดือนก่อน

      @@RadioRich100 ignorant 🤦🏻.

    • @co7366
      @co7366 4 หลายเดือนก่อน +3

      @@RadioRich100 my friend research it yourself, test the voltage usage yourself. There are plenty of great videos that measure the start up amperage and normal running amperage.
      How do you think people run their AC unit with a basic generator?
      Also it can expand the life of your compressor and fan as well. Do yourself a favor and research and learn it yourself, don’t listen to some hvac guy that possibly is clueless about soft starts. You have in front of you a very powerful device, I’m talking about your smart phone and or computer, use it..Google and learn

  • @Sixbagzz
    @Sixbagzz 5 หลายเดือนก่อน +4

    I got mine on order. My unit starts just like how yours did. Can't wait to install this!

    • @PaulBailey3
      @PaulBailey3 5 หลายเดือนก่อน +1

      You'll appreciate it. Worth the $350

  • @jmill7450
    @jmill7450 5 หลายเดือนก่อน +1

    Nice video. Very thorough and easily explained. The satisfaction I got from hearing the before and after definitely sold me lol.

    • @jmill7450
      @jmill7450 5 หลายเดือนก่อน

      @@RadioRich100 it’s that much of a difference??

    • @hyoslvr1668
      @hyoslvr1668 5 หลายเดือนก่อน +1

      @@jmill7450 He's a clown troll. Obviously a disgruntled customer who had a bad run in with customer service

    • @jmill7450
      @jmill7450 5 หลายเดือนก่อน +1

      @@hyoslvr1668 ahhh gotcha. One of them, huh ?

  • @geoffreypinard6278
    @geoffreypinard6278 5 หลายเดือนก่อน +2

    Thank you for the simple and clear explanation. Have ordered a system to allow operation with a generator during power outages. Just saved $300+ on a proposed installation cost.

  • @BradsTechCorner
    @BradsTechCorner 5 หลายเดือนก่อน +2

    Great video. Reddit points to this being a positive and gaining life out of the compressor. Less hard starting on the compressor makes sense that it extends its life. It does seem to however be a gray area for warranties but generally doesn’t void it from what I’ve seen.

    • @851995STARGATE
      @851995STARGATE 2 หลายเดือนก่อน

      It definitely won't void it, you can pretty much fight it as a hard start or soft start kit. I would pair this up with an Emerson sure switch

  • @tjjoseph333
    @tjjoseph333 5 หลายเดือนก่อน +1

    Great video. Doing this in a few weeks for potential Generator start capability. Many Thanks!

  • @jackonthefarm5540
    @jackonthefarm5540 5 หลายเดือนก่อน +1

    I installed a micro-air soft start last year. I love it. I have also had to run off a generator for 48 hours and we had full use of our A/C due to the soft start drawing much less power at start-up.

  • @surgpsych
    @surgpsych 5 หลายเดือนก่อน +1

    OMG!! just sold me on the before and after sound clips! Thanks a million for the great video!

    • @surgpsych
      @surgpsych 5 หลายเดือนก่อน +1

      @@RadioRich100 cute reply. It would be MUCH more helpful, with logical reasoning, if you can explain exactly the negative mechanisms of this product , so I would reconsider purchasing one . thx

  • @alexandermirdzveli3200
    @alexandermirdzveli3200 6 หลายเดือนก่อน +8

    Your vintage electronics says huge thank you for installing the gadget.

  • @ImagineWYXZ
    @ImagineWYXZ 4 หลายเดือนก่อน

    Thank you for your video. You answered so many of my questions in your video. You helped me make my decision. Now time to purchase mine before the next hurricane hits!

  • @SteeledJester
    @SteeledJester หลายเดือนก่อน

    Awesome video, I learned a lot thank you very much!

  • @GH-wt7ww
    @GH-wt7ww 6 หลายเดือนก่อน +22

    Micro air tech support said to me the "Flex" model is replacing the EasyStart ASY-368-X72-BLUE model. The Flex model is suppose to be 40-50% smaller.

    • @elwaposv
      @elwaposv 5 หลายเดือนก่อน +1

      Came here to ask this question. Thank you.

    • @tallywacher5569
      @tallywacher5569 5 หลายเดือนก่อน +2

      The only difference is size and one box fits all tonnage. The old 368 boxes are cheaper the lower the tonnage, thus people with smaller units are paying more. Buy the old boxes while you can for a cheaper price.

    • @jonathonanderson8004
      @jonathonanderson8004 5 หลายเดือนก่อน +1

      I like that this should be able to go with me to my next home. Not happy about the price, but happy with the quality. Currently 2.5 tons

    • @michaelblodgett4704
      @michaelblodgett4704 5 หลายเดือนก่อน +4

      I am installing a Flex on my 5ton. LRA about 150. I'm seeing people get starting amps down in the 30s. This is important for people using a portable gen for whole home power. There is a big movement of people doing this down here in hurricane alley. It should be mentioned that this company has incredible customer service and support. This unit has Bluetooth capabilities and you can run diagnostic and then email to Micro-Air and they will help you troubleshoot.

  • @michaelhenderson5098
    @michaelhenderson5098 5 หลายเดือนก่อน

    Thanks for making this video. I have a new Easy Start sitting here on my desk ready to go. Our 3T is loud, and flickering lights are common. Also, my WGen7500DF generator wouldn't run the AC along with our freezer, fridge, and a couple of fans during our 8 day outage last week because of Hurricane Beryl. Hopefully this will be a good thing for our situation.

  • @shandorn1077
    @shandorn1077 5 หลายเดือนก่อน +2

    Out of all the videos on TH-cam regarding how to properly install this....your video by far was the best I have seen. It solved my problem instantly, thanks!

  • @dadsgarage.alwaysopen
    @dadsgarage.alwaysopen 3 หลายเดือนก่อน

    Just installed my flex yesterday. Starting amps went from 77 to 18.7 after the learn cycles. Thanks for sharing your install. It was immensely helpful to complete mine. I’ve heard these flex units fail prematurely and the company is not very responsive in replacing them under warranty. I would love to hear anyone else’s experiences.

    • @DmitryBrant
      @DmitryBrant  3 หลายเดือนก่อน

      Thanks! Mine has worked just fine since I installed it ~2 months ago, with about 2000 starts total. We'll see how it holds up next season, but pretty happy with it so far.

  • @mr.boniato6402
    @mr.boniato6402 3 หลายเดือนก่อน

    Thanks for the video. I wanted to see if it made an difference in the starting amps. By the way, not gonna lie, you got me with the cut off video when connecting the breaker lol

  • @TheKomar924
    @TheKomar924 5 หลายเดือนก่อน

    Ordered mine right after Beryl. Lost in shipping atm but hopefully ill get it soon and test b4 and after !!!

  • @mrBDeye
    @mrBDeye 4 หลายเดือนก่อน +1

    Wow what a difference in noise reduction. I need one.

    • @musicnerd72
      @musicnerd72 4 หลายเดือนก่อน

      ​@@RadioRich100 Do you need a cry towel?

  • @MToytube
    @MToytube 4 หลายเดือนก่อน

    Holy smokes.. I did a Hyper Engineering Surestart on mine a few years ago (3 ton).. but it doesn’t even come close to that level of noise reduction. I may need to switch it up! I’m in the generator motivated crowd. Thanks for the video!

  • @reodds
    @reodds 5 หลายเดือนก่อน

    Great video!! I installed one on my a/c and 2 on my Brother's units about a year ago. Easy install, they work great, and my interaction with the Company was fantastic. Great customer service and help answering questions. I highly recommend Easy Start for ANYONW with an a/c.

  • @g-wolf9445
    @g-wolf9445 5 หลายเดือนก่อน

    I have the 368 model running with my condenser and the Flex does look to be smaller by 25%; pretty much the same as the setup as in the video but the 368 was too big to jam into the same spot. Great video.

  • @DavidVarghese93
    @DavidVarghese93 5 หลายเดือนก่อน

    Thanks for the video. This helped a lot along with the microair ac install guide.

  • @CharliePowell-dy1tl
    @CharliePowell-dy1tl 5 หลายเดือนก่อน

    These are a must if you have solar power. I have 2 more to install for people with solar. I read about them for 2 years before trying it on my rv. My start up amps went from over 30 to 8 amps and it’s so much quieter. I tried to get a few hvac wholesale stores to carry them but no luck yet. They will!

    • @CharliePowell-dy1tl
      @CharliePowell-dy1tl 5 หลายเดือนก่อน

      @@RadioRich100 I installed an ICM soft start 3 years ago and still going strong. RV a/c’s are factory installing these too so people can run their ac with small generators. I was skeptical of hard start capacitors when they came out too. I researched soft starts for years before trying one and they are much better than hard start capacitors. And they cost a lot more.

    • @CharliePowell-dy1tl
      @CharliePowell-dy1tl 4 หลายเดือนก่อน

      @@RadioRich100 They are absolutely factory installed by Coleman for RV’s. They offer a soft start series. Soft starts will increase compressor life and reduce energy consumption.

    • @RobertTaylorRTC
      @RobertTaylorRTC 4 หลายเดือนก่อน

      @@RadioRich100 Sir, you are very much mistaken. Coleman has made RV AC units for years. They are not as popular as Dometic ACs but they are very much a player in the RV market. Oddly enough, I am commenting simply because my RV currently has a Coleman AC sitting on the roof. Not sold on the whole soft start trend, so I can't agree or disagree with you on that point. As for Coleman, they produce much more than just coolers and lanterns.

  • @Earlvis
    @Earlvis 4 หลายเดือนก่อน

    You may consider getting a 25k ohm 20 watt resistor with wire/alligator clip on each end to bleed your capacitors. It’s a slow bleed that won’t damage your capacitors. I use one especially for electrolytic capacitors. It takes about thirty seconds to discharge and is the best method for bleeding them.

  • @GH-wt7ww
    @GH-wt7ww 5 หลายเดือนก่อน +1

    Had the Micro-Air Easy Start Flex installed by my HVAC company last week on my 5 ton Carrier unit that is 14yrs old. LRA is 117a on the label of the unit. It is now 24.5/34a on start up. A couple of things I learned from tech support. Bluetooth signal is low power so you have to be within 2ft or closer to connect to the app. Also any solid stream of water like sprinklers or water coming off the roof in direct contact with the Flex , water will intrude and void the warranty. I asked about applying a bead of clear silicone around the window and where screws were. They said that would void the warranty. They suggested a water proof box to put the Flex in like other customers have done.

    • @DmitryBrant
      @DmitryBrant  5 หลายเดือนก่อน

      Hmm interesting, thanks for that note. I guess by making the unit smaller, they expect more users to be able to install it inside the panel itself. But I do recall reading that it's supposed to be IP65 rated, which I suppose is for general "weather" resistance, but it sounds like they're being sticklers about specific types of water presence around it.

    • @michaeladams4592
      @michaeladams4592 5 หลายเดือนก่อน

      Will not void your warranty with MicroAir. It is IP65 rated, they even say you can mount it outside the compartment if there isn't room for it inside. Just make sure you install with the wire exiting downward to be on the safe side (in case of pooling on the waterproof grommet). If your HVAC company told you that, maybe they were referring to their own installation warranty or something.. but MicroAir themselves are extremely supportive and state on their own videos these can be installed externally/in contact with elements.

    • @GH-wt7ww
      @GH-wt7ww 5 หลายเดือนก่อน

      @@michaeladams4592
      I agree with the wire exiting downward and so far I have been very pleased how the starter has been working. Everyone will have a different situation to their application but be mindful where it is installed. Mine is installed on the exterior above the liquid and suction lines since there was no room inside the panel as you did and never any pooling. I asked tech support if I could just add a small bead of clear silicone on the seam where the box and clear top meet and where screws go in for extra added water protection since we get a lot of high winds and heavy rain here in Houston, Tx.
      This is a copy and paste from tech support response. They do not want direct water hitting them.
      " The starters are IP65 rated meaning they're water resistant but can't be installed where they'll direct roof runoff or main sprinkler water hitting them."
      You'd do better to make or purchase a box to mount it in like I've seen several other customers do.
      Do not add any kind of sealant or this will void your warranty.

  • @jaxsonhugh9334
    @jaxsonhugh9334 5 หลายเดือนก่อน +18

    Never ever assume the power is off just by pulling the disconnect. Always test for voltage at the contactor.

  • @jjhowey
    @jjhowey 5 หลายเดือนก่อน +1

    With all the precautions at the beginning, I am surprised you physically screwed in the Micro-Air before testing it all worked :).

  • @keithfowler66
    @keithfowler66 5 หลายเดือนก่อน +1

    Great job 👍

  • @jwhite4
    @jwhite4 5 หลายเดือนก่อน

    Nice video.
    Energy savings - I was going to post this as a reply to a post below, but thought I'd make it a separate post. I don't think it will provide any savings. As Dmitry commented below, the amp reduction is only for a brief while, at startup. So while that technically does save some current ($), the compressor isn't doing as much work (as much cooling). It will bee to run longer to make up for the missing BTU's. It converts that huge bu brief current spike to a lower but longer current draw. At the end of the day, it'll end up being the same total current draw. I don't think any soft start manufacturers advertise energy savings as a benefit.
    Also thanks to the poster that determined that the Flex is an all-capacity, but 25% smaller unit, than the original Breeze, which you had to buy in 3T, 4T, or 5T capacities. I only need a 3T unit for my house, so a ~$299 3T Breeze might be fine. Deciding if it's worth getting the Flex, figuring the smaller unit might (and latest and greatest version) might be worth the higher cost.

  • @jonathonanderson8004
    @jonathonanderson8004 5 หลายเดือนก่อน +1

    So glad I bought this before you uploaded this great video, demand will probably shoot up for this smaller company. July in Florida though so I don’t want to go outside to install it! Need to man up

  • @56nomadman
    @56nomadman 5 หลายเดือนก่อน

    Great video Dmitry!

  • @DarthChainsaw
    @DarthChainsaw 5 หลายเดือนก่อน

    I just got one but haven't installed yet. My ac unit is new and pretty quiet but has a high LRA and I'm specifically doing this to run my AC with my generator.
    It's kind of pricy but a must have for my situation.

    • @michaelgraham8504
      @michaelgraham8504 5 หลายเดือนก่อน

      LRA has nothing to do with it running!

    • @AndrewShaw777
      @AndrewShaw777 5 หลายเดือนก่อน

      @@michaelgraham8504 of course not. He is planning to use the soft starter to drop the LRA so it can start on a reasonably-sized generator

  • @JimGnatek-y7z
    @JimGnatek-y7z 6 หลายเดือนก่อน +9

    If you use the bluetooth feature to monitor starting current and number of starts you may find that it may have faults due to a capacitor or loose wiring problems. Micro Air was very helpful in solving these problems for me. You may also find that the compressor does hum louder on startup as time goes on.

    • @aholmes6612
      @aholmes6612 6 หลายเดือนก่อน +5

      What I have found is that you have 5 learn starts when installed. I installed mine when it was cooler during the spring but once we got to 100 degrees everyday I had a fault, so I reset it to learn all over again...problem solved.

  • @EricHenleyColorado
    @EricHenleyColorado 4 หลายเดือนก่อน +2

    To add to the discussion. I bought a MicroAir soft starter. Had the company confirm that is was sized correctly and they even verified the connections - run wire, etc. Worked great for 2 months. Then no cold air. House in Florida, in the summer, heating up to 85+. I was out of town, so called my local AC tech and he discovered the run wire connection from the soft start was burned. For a distance of over 6 inches. He rewired the AC and Voila cold air again. I contacted MicroAir and told them what happened. Me being a trusting consumer, I thought they would stand by their product. NOPE! They told me the failure was caused by the heat. You think? Florida, in the summer, DUH! The original run wire worked for 9 years and after reconnecting the AC works fine. There is something wrong with the soft started and they won't admit it or support their unit. BUYER BEWARE!!

  • @ZimorKilled
    @ZimorKilled 5 หลายเดือนก่อน

    Excellent video. Thanks for providing. Helped me to install quickly. I completed the install this past weekend on both my 3 ton and 2 ton units. I received 65% reduction on inrush, and minimal amps reduction on running. Given the cost of these units and cost for electricity, in Houston, I will never receive a payback. But, I installed these units so I could run my generator and start both AC units, which I couldn't beforehand. Maybe I could extend the life of my units by 1 year, but, that is an unknown.

    • @ZimorKilled
      @ZimorKilled 4 หลายเดือนก่อน

      @@RadioRich100 I measured current both from my meter and as-noted on the Bluetooth app supplied by Micro-Air. Although not exactly the same amp reading, it was close. Soft starters for AC units provide a "ramp-up in voltage" that enables lower amperage and less heat, and wear and tear, on the fan and compressor motor. I am a registered Mechanical Engineer in the state of Texas.

    • @ZimorKilled
      @ZimorKilled 4 หลายเดือนก่อน

      @@RadioRich100 Well geez ... I couldn't start my 3 Ton unit with the generator powering my house, before installing the soft starters, now I power both my AC units with spare amps to run microwave and other smaller appliances. This was confirmed when Beryl came through. But, have it your way ... I will keep my soft starters.

    • @ZimorKilled
      @ZimorKilled 4 หลายเดือนก่อน

      @@RadioRich100 I have a Generac 24kw unit. Measured load, without AC + normal household operation is (refrig, etc.) measured at 22 amps (measured by the gen installer). The 24kw has a max load amperage of about 90. LRA for the 3 ton is 91 amps, and 2 ton is 67 amp. Obviously, I can start the 2 ton without the soft starter but 3 ton just trips on in-rush overload - this was proven at commissioning. Now, with the soft starters, I am at ~ 70 amps for normal household PLUS both units starting at same time ... which is not real world scenario. This has been proved. If I bought a larger size generator, it would be so expensive, and too large for my neighborhood to accept the sound level, plus, running load is on a larger generator would be about 30% and that is NOT a good operation for long-term engine running ... increase of deposits on cylinder walls and heads. Not everyone is wealthy to overbuy a generator and not everyone lives in the country where they can install generator 100 feet from their home to reduce noise level.

    • @ZimorKilled
      @ZimorKilled 4 หลายเดือนก่อน

      @@RadioRich100 People reading this reply should ignore what this guy is saying. I am an engineer and I have done my homework, and determined these soft starters - not hard starters - will NOT void your warranty and does NOT degrade your system, anyless than normal wear and tear.

    • @ZimorKilled
      @ZimorKilled 4 หลายเดือนก่อน

      @@RadioRich100 LOL, I am a retired engineer from Chevron and have the pleasure of managing, designing, installing and operating $1B plus offshore platforms and mid-stream gas plants around the world. I have extensive experience in petroleum, process, mechanical, electrical, and structural engineering. Most important, I am a thorough and sensible engineer and dont do anything unless I have done my homework. On top of all this, my Dad was a AC certified installer of Carrier HVAC systems and I helped him in the summer crawling around hot attics, in the Houston area - i.e. I know my way around HVAC units. Salesman - nope; manufacturer - nope. Just a retired engineer in the Houston area, trying to keep cool.

  • @dewaltgrainger2923
    @dewaltgrainger2923 5 หลายเดือนก่อน +3

    I just ordered mine. I’m from Houston, Tx. Need I say more 😢

    • @Dillinger128
      @Dillinger128 5 หลายเดือนก่อน +1

      im north of you in conroe, just put mine on and it makes a hell of a difference on generator. my 4ton isnt beating the stator on my genset up any more. 20kW genset was dragging down hard after beryl.

    • @dewaltgrainger2923
      @dewaltgrainger2923 5 หลายเดือนก่อน

      @@Dillinger128 what size generator are you running??

    • @Dillinger128
      @Dillinger128 5 หลายเดือนก่อน

      @@dewaltgrainger2923 20kW

    • @Dillinger128
      @Dillinger128 5 หลายเดือนก่อน +1

      @@dewaltgrainger2923 20kW. is it enough? yeah, but my 4ton American standard silver did drag it down with the inrush current and cause all my lights and battery backups to blink and beep. it also smoked my fuel down by 10% a day with those hard starts. I have a 250 gallon propane tank on my generator. NG is not available where I am in the woods.

  • @seanmcd72
    @seanmcd72 5 หลายเดือนก่อน

    I need one of these! My outside unit looks just like that.

  • @socalpaul487
    @socalpaul487 5 หลายเดือนก่อน +1

    You can also upgrade the fan blades from the simple paddle style fan to a more advanced style fan. It will get rid of the helicopter sound. This is an example, yours may differ.
    FAN05905 - OEM Upgraded Condenser Fan Blade Replaces Trane.

  • @kelloggfan
    @kelloggfan 4 หลายเดือนก่อน

    it would be great to get a close up of the wiring where you put the white hire...thanks!

  • @wisdomsquare28
    @wisdomsquare28 4 หลายเดือนก่อน

    Great work! Much gratitude! What are the energy savings?

  • @maxwellcrazycat9204
    @maxwellcrazycat9204 3 หลายเดือนก่อน

    Wondering how an install on a new condenser would affect the warranty.

  • @shawnhayes4949
    @shawnhayes4949 4 หลายเดือนก่อน

    Can? And how? this be installed on a 115v lawn sprinkler pump to achieve low in rush amps? I’m running on battery back up and want to reduce startup amps on my battery system. I’ve only seen this used on hvac but been told it works on electric motors as well??

  • @plebe791
    @plebe791 5 หลายเดือนก่อน +1

    Thank you for sharing

  • @cezarnebun9607
    @cezarnebun9607 5 หลายเดือนก่อน +1

    FYI...LRA is when the motor is fully locked, not spinning at all...when we test motors at work we only perform the test for less than a second in order to not burn the motor windings. Sure the motor does pull a lot of amps when starting up but will never be at LRA spec since it is not truly locked up. Great video, btw. I am really surprised that they don't include the installation hardware, especially for the price.

  • @maxwellcrazycat9204
    @maxwellcrazycat9204 4 หลายเดือนก่อน

    Got my Micro-Air Easy Start Flex unit today. 8-27-24. Reading over the paperwork. It sure would have been nice if the installation kit were offered at the same time as ordering the unit. Now I have to wait more days to receive it. Slow shipping. I went back and checked. My bad. The kit was offered. I overlooked it. Sorry about that. My edit.

  • @ItIsJustDan
    @ItIsJustDan 4 หลายเดือนก่อน

    Got a question, if my home is all electric, do I need a soft start of some kind for the air handler? It's a 20 year old American Standard paired with a 4 ton. Thank you.

  • @tablatronix
    @tablatronix 5 หลายเดือนก่อน +5

    wow this should be standard

  • @richlikeg3722
    @richlikeg3722 6 หลายเดือนก่อน +6

    I think having compressor soft starting compared to the hard starts will increase the life expectancy of it. Not sure if I read that somewhere? 🤔

    • @co7366
      @co7366 5 หลายเดือนก่อน

      Correct. Imagine pressing your cars gas pedal to the floor and then going from park directly to Drive vs slowly accelerating to the appropriate speed.
      A lot of wear and tear in the long run.
      It saves some electricity as well

  • @Roadhammer42
    @Roadhammer42 หลายเดือนก่อน

    Be sure to use your wiring diagram on the unit. The colors may be different. On my cap it was the purple wire and not the orange wire.

  • @zekenzy6486
    @zekenzy6486 5 หลายเดือนก่อน

    Great video. Thank you for sharing. May I ask ? Please. Could you share link website , where to buy it in description ?

    • @JetFire9
      @JetFire9 5 หลายเดือนก่อน

      Just google micro-air easystart flex. You’re welcome!

  • @mylesprior4985
    @mylesprior4985 3 หลายเดือนก่อน

    Try to find these? 3 months back ordered! I'll wait til Feb. 2025

  • @GroovyCachinDude
    @GroovyCachinDude 2 หลายเดือนก่อน

    Any savings on your power bill?

  • @pickandstrum
    @pickandstrum 5 หลายเดือนก่อน +2

    Very nice step by step instructions do you think you will see and energy savings by lowering the inrush current that much?

    • @DmitryBrant
      @DmitryBrant  5 หลายเดือนก่อน +2

      Thanks! As far as energy savings, it's probably not that much -- we're only talking about ~1 second worth of inrush current, versus many minutes worth of regular operation which won't be affected. It might be enough to pay for itself over the lifetime of the AC system, but I wouldn't say the energy savings should be a deciding factor for getting it.

  • @RabbleInArms
    @RabbleInArms 2 หลายเดือนก่อน

    Is this still working well for you? I've seen lots of negative reviews on these new flex units blowing caps.

    • @DmitryBrant
      @DmitryBrant  2 หลายเดือนก่อน +1

      Haven't turned on AC in many weeks (October in Massachusetts), but it worked just fine the rest of the season, about 2000 total starts, according to the app.

  • @davidtn227
    @davidtn227 5 หลายเดือนก่อน

    Do you have links on all the connectors you used? I do not want to make multiple trips to the hardware store. Thanks!

  • @JM-fk5hh
    @JM-fk5hh 5 หลายเดือนก่อน +1

    Very good explanation of soft start unit.

  • @Ripcord10
    @Ripcord10 4 หลายเดือนก่อน

    Just installed mine yesterday...was working great, now when the AC turns on from the thermostat the contactor buzzes the whole time unit is running. I can manually start it from the switch at the contactor and no buzzing happens....anyone have ideas?

  • @charlesschaefer1584
    @charlesschaefer1584 4 หลายเดือนก่อน

    Will this also help lower your electric bill?

  • @chrissignal8857
    @chrissignal8857 4 หลายเดือนก่อน

    My Lennox AC here in Florida is 16 years old. No soft start.

  • @nCon808
    @nCon808 5 หลายเดือนก่อน

    My ac unit doesn’t have a disconnect lever like yours does. Will shutting off the breaker be good enough to shut power from the unit? Thanks!

    • @DS-fb9te
      @DS-fb9te 5 หลายเดือนก่อน

      breaker box should be same, outside is just a convenient way

  • @kelloggfan
    @kelloggfan 4 หลายเดือนก่อน

    I hooked mine up and now it doesn't cool. cool air out the compressor fan. - disappointing! followed your instructions exactly - then i shut off the system because you said it has to start 5 times - but it never stopped because it wasn't cooling. i shut the system down and now the thermostat says waiting for equipment. also, i noted - the blue wire on the left side was buzzing when i unconnected it - and reconnected - the contactor clicked in...when the power was off! is this normal? the EASY START has a green light and a red blinking light 7 times...then repeats as soon as i bypassed the easystart - the AC started cooling again! I looked up the 7 red lights and it says "Start Winding not Detected/Mis-wiring"

  • @wadepruetz1514
    @wadepruetz1514 5 หลายเดือนก่อน +1

    I want one of these and especially the Micro Air but I know of at least 3 people that installed these and they ran less than 2-4 weeks before burning up. One guy, who is a friend of mine, is an AC technician so I know it was installed correctly. He called me after he installed his telling me how great it was, about a week later he called back saying it just burned up most of the capacitors. It sounds like Micro Air's customer service isn't that great either. Does anyone have any long term experience with these?

    • @LaseredIllumination
      @LaseredIllumination 5 หลายเดือนก่อน

      My experience has been quite the opposite. I have the older larger model on mine. It's been running for right at 2 years and it has 9619 starts since installation.
      I did have an issue when the actual app updated on my phone, it "bricked" the unit and my ac wouldn't come on. I disconnected the easy start and the ac ran fine.
      I contacted them and they had me on the phone with their electrical engineer/app developer the same day. Ended up being a bug in the update. He remotely pushed an update to my unit over the air and I was back up and running with it connected that afternoon.

    • @fattysgarage1754
      @fattysgarage1754 5 หลายเดือนก่อน

      I installed mine 2 years ago and it’s been flawless. About 23,000 starts to date. Never an issue, not 1. Ran my 3 ton unit and house for days after hurricane. LRA went from 77 to 26 and runs at 9 amps. My unit was 10 years old when I installed it.

  • @kitbram2033
    @kitbram2033 5 หลายเดือนก่อน

    Impressive.

  • @kogiekobayashi3421
    @kogiekobayashi3421 5 หลายเดือนก่อน

    I am interested to get it for my 2.5 and 4 ton Trane. What model and where did you get it? I have inquire and some air conditioner company ask for an arm and a leg to instal it.

  • @simprophet
    @simprophet 6 หลายเดือนก่อน

    How does an air conditioner cool down a house?? 0:40 In Rush Current

    • @Monztuh
      @Monztuh 5 หลายเดือนก่อน +1

      Lol i get it bro

  • @JillofAllTrades2
    @JillofAllTrades2 5 หลายเดือนก่อน

    So is it basically converting a one- or two-phase condenser to a multi-stage/variable/inverter type condenser? The EasyStart does NOT work with inverter / variable condensers.

  • @hjjordan2
    @hjjordan2 5 หลายเดือนก่อน

    Does the wiring harness come with the product in the box?

    • @DmitryBrant
      @DmitryBrant  5 หลายเดือนก่อน +1

      Yes, the unit comes with the wires already coming out of it.

  • @DragonXBlasterXRager
    @DragonXBlasterXRager 5 หลายเดือนก่อน

    Thanks for a great instruction. Where do you buy the Easystart unit? Thanks again

  • @mcneely2679
    @mcneely2679 5 หลายเดือนก่อน

    Hello Dmitry! Your video was so well done, I when on Amazon to purchase. Which Kit or Kit number did you used in this video?

  • @GatoGamingSi
    @GatoGamingSi 5 หลายเดือนก่อน

    I've been looking for one for my house but the ones on Amazon seem to be for RV use. Where did you get yours?

  • @DS-fb9te
    @DS-fb9te 5 หลายเดือนก่อน

    just remember DIY community, soft star is for single stage only

  • @Simple_retired_life
    @Simple_retired_life 5 หลายเดือนก่อน

    Can you please share where you purchased it? Website link . Tfs!!

  • @liltiti86
    @liltiti86 5 หลายเดือนก่อน

    What easy start do I need for a 5 ton 150Lra

  • @Dillinger128
    @Dillinger128 5 หลายเดือนก่อน

    my flex did 7 learn starts. did yours?

  • @maxwellcrazycat9204
    @maxwellcrazycat9204 3 หลายเดือนก่อน +3

    Installed my flex start today 9/16/2024. Goodman condenser. Letting the learn process procced. On #4 learning start. After #5 I'll see how it does with my Westinghouse WGEN9500DF.
    It pared right away to my android phone. Note that the app only works while the AC is running. So far no faults.

    • @brogers114able
      @brogers114able 3 หลายเดือนก่อน +1

      Keep us posted. I've got a flex that I'm about to install. I'm seeing many complaints on premature failure for the newest model. The flex.

    • @nametaken24
      @nametaken24 3 หลายเดือนก่อน

      ​@@brogers114able Where are you reading about failures? Does it fail the whole AC system or just the soft starting?

    • @brogers114able
      @brogers114able 3 หลายเดือนก่อน

      @nametaken24 if you search you tube videos for micro air flex, there are many comments within the last 2-3 months saying theirs died within a few weeks of install. Just the soft start dies. Everything else is fine if it fails.

    • @maxwellcrazycat9204
      @maxwellcrazycat9204 3 หลายเดือนก่อน +1

      @@brogers114able It has done 7 learned starts. 17 starts after that. No faults.as of 9/22/2024. My AC runs fine with my generator on propane.

  • @enyol
    @enyol 5 หลายเดือนก่อน

    wanting to order one

  • @marct9587
    @marct9587 6 หลายเดือนก่อน

    So, what did you do with that wire that was originally connected to the herm terminal on the capacitor? Did you terminate it with something?

    • @DmitryBrant
      @DmitryBrant  6 หลายเดือนก่อน +6

      That wire stayed on the Herm terminal; The new wire was in addition to that one. (The capacitor terminals have multiple connectors that you can plug onto, exactly for these kinds of purposes)

  • @curtisramsey2219
    @curtisramsey2219 5 หลายเดือนก่อน

    Will this save you money on the electric bill??

  • @cribeye9339
    @cribeye9339 5 หลายเดือนก่อน +1

    Takes money but adding a compressor sound deadening cover will decrease even more sound. God Bless America

  • @KarlMiller
    @KarlMiller 5 หลายเดือนก่อน

    Did you void the manufacturer's warranty by installing this yourself?
    Do you also have a surge protector before the soft-starter in the circuit?

    • @DmitryBrant
      @DmitryBrant  5 หลายเดือนก่อน +1

      I don't see anything in the warranty regarding who performs the installation, but I haven't asked the manufacturer directly. As it happens, I do have a whole-house surge protector on my main panel. But then, wouldn't this be another benefit of having this kind of kit, where it could become a "sacrificial" device, and protect your AC unit in case of a surge?

  • @EdwinIrving-lj1wz
    @EdwinIrving-lj1wz 6 หลายเดือนก่อน +6

    Would have been informative to show the before andcafter start currents

    • @slurpeyatari
      @slurpeyatari 5 หลายเดือนก่อน +2

      Go ahead and make your own video to show everyone that information.

    • @co7366
      @co7366 5 หลายเดือนก่อน +1

      Peak of 30Amp and Live at 13 Amp with flex installed. Look at his schematics early in video I think it used to be Peak of 134amp and ran live at 28-30Amp. The man took the time to record this in great detail show a little appreciation

  • @LygerTheCLaw
    @LygerTheCLaw 5 หลายเดือนก่อน

    how much better is this that a hard start cap? i mean it is almost 100 times the cost.

    • @ZimorKilled
      @ZimorKilled 5 หลายเดือนก่อน

      A hard start provides more power to start a compressor. Soft start is opposite, it reduces power to start the compressor and fan motor.

  • @ron2368
    @ron2368 4 หลายเดือนก่อน

    With more efficient delivery of amps, it's supposed to prolong the compressor's lifespan.

  • @jameschuke4104
    @jameschuke4104 4 หลายเดือนก่อน

    Put a amp meter on your hot wire out n see max amps before n after

  • @fredares5463
    @fredares5463 3 หลายเดือนก่อน

    You keep saying relay that’s a contactor. Make sure you say what you mean and mean what you say cause a lot of people start looking for a relay and be very confused. You’re welcome and thank you.

  • @dodgee_doo
    @dodgee_doo 5 หลายเดือนก่อน

    I hate that I cannot monitor error codes and I have to send the data to the company to get results back. That's the only thing stopping me from recommending it.

  • @Bill_CBR
    @Bill_CBR 6 หลายเดือนก่อน +1

    Would have been nice if you had recorded the actual starting current (peak in-rush current) as well as what is the actual running current while the compressor is running.

    • @aholmes6612
      @aholmes6612 6 หลายเดือนก่อน +1

      Min went from 150 down to 37 and running at 10.9

    • @co7366
      @co7366 5 หลายเดือนก่อน

      He mentioned in another comment peak Amp is 30 and live now is 13A

  • @leiferickson713
    @leiferickson713 5 หลายเดือนก่อน

    As an electrician, I don’t believe in one fits all. In rush draw is different on each size compressor. They need to make the appropriate item for each unit.

  • @fb510m
    @fb510m 5 หลายเดือนก่อน +2

    Micro air wiil make a ton of money when they figure out how to eliminate the cap by installing their tech

  • @AshtonCoolman
    @AshtonCoolman 5 หลายเดือนก่อน

    Its Bluetooth functionality probably won't work well with it behind the metal cover. Otherwise great video!

    • @Sashazur
      @Sashazur 5 หลายเดือนก่อน

      Another comment said it is low energy Bluetooth, so it would have limited range anyway.

    • @DmitryBrant
      @DmitryBrant  5 หลายเดือนก่อน +1

      Haha yes, I realized it has a bluetooth function after I already installed it, and you're right that it's basically inside a faraday cage, but I was able to communicate with it within a couple of feet.

    • @AshtonCoolman
      @AshtonCoolman 5 หลายเดือนก่อน

      @@DmitryBrant I bought some magnetic, rubber covered feet for mine on Amazon. They arrived today. I'm going to just slap mine on the outside of my unit with them. It'll also let me hide it under the panel if necessary.