Where do you top up the gas? And how long once need to top up?? At what pressure need to do?! Previously any issue you resolved that has leaking in chiller like that??
Hi @mohhamed in the video I mentioned evaporator service port at 13:39 you can check the pressure levels..and u can use the same port to top up the gas also... Actually when there is no problem in the system,we no need to top up the gas...some systems may get some internal gas leaks.. during that time we can topup the gas.. During your maintenance if the pressure levels are ok..or with in the range..u no need to top-up .. Pressure levels are for R134A is suction side 40 psi max discharge side 120 psi max..u can convert it into kpa if you want.. I faced a leak issue after annual shutdown at the filter drier side...then we rectified it .
Surpb explanation 🎉
Beautiful brother
nice bro this video more helps to me understand the york chiller because my site also same type york chiller pls continuously upload more video about acmv systems
Awesome explanation
Thalaiva , superb
Very useful thanks bro
Good one, also explain about equaliser line, makeup water, chilled water header please
Superb nice explanation
Clear explanation.Suberb🎉
Thank you 🙂bro
Thank you sir clear explanation 👍👍
You're most welcome
Super thala❤
Super bro
Bro, could you please tell me exactly at which point the refrigerant is mixed with the oil??
Bro keep upload this kind of informative videos❤
Sure bro
Thank you for explain
Pls explain how to compressor pump down
Super 👍 good explanation
Thank you 🙂
Good 👍
Thanks
Hi sir,good message thanks, can u sent the types of starter in centrifugal chiller, example solid state and vsd starter and function.
Super explanation sir
Thanks and welcome
Where do you top up the gas? And how long once need to top up?? At what pressure need to do?! Previously any issue you resolved that has leaking in chiller like that??
Hi @mohhamed in the video I mentioned evaporator service port at 13:39 you can check the pressure levels..and u can use the same port to top up the gas also...
Actually when there is no problem in the system,we no need to top up the gas...some systems may get some internal gas leaks.. during that time we can topup the gas..
During your maintenance if the pressure levels are ok..or with in the range..u no need to top-up ..
Pressure levels are for R134A is suction side 40 psi max discharge side 120 psi max..u can convert it into kpa if you want..
I faced a leak issue after annual shutdown at the filter drier side...then we rectified it .
Bypass valve explain pannuga
Sir york air coold cheller pathiyum podungal.
Sure
Bro, compressor ku mela oru PRV irukuthu. Athoda use ena? and Compressor discharge line la irukura discharge valve oda use ena?
Bro please explain to chiller power supply to the MCC panel
👏🤝🙏
Chilled water insulation illeya
That is jacketing insulation...
@@shivaHVAC thank for the information
Need chiller plant monthly ppm video
Anna air cool chiller function sollunga
Secondary pump, primary pump sollugga bro
Bro which type gas used in chiller
R134A
Chemical name(Tetrafluoroethane (CH2FCF3)
R-123,R1233ze, R-1234zd,R-514 these All negative chillers, and R134-a is positive chiller