Introduction to insulation testing using a Megger

แชร์
ฝัง
  • เผยแพร่เมื่อ 26 พ.ย. 2024

ความคิดเห็น •

  • @rozero123459gnh
    @rozero123459gnh 4 หลายเดือนก่อน +5

    Great video! I just bought this meter and your explanation makes things clearer!

  • @slomotrainwreck
    @slomotrainwreck 5 หลายเดือนก่อน +2

    Good video! I'm not an electrician but I do have my General class ham license and that's where I've seen people use a megger to test lengths of coax before installing it, it's the right tool for the job. 👍

  • @awesomeelectricalengineer3487
    @awesomeelectricalengineer3487 4 หลายเดือนก่อน +4

    Good video. As others have mentioned, in the UK this would be correctly termed 'Insulation Resistance Testing', Megger is a brand name. Someone will correct me if I'm wrong, but I believe Megger made some of the first insulation resistance testers, hence the term 'Megger Testing' stuck. In the UK we insulation resistance test all new circuits as required by standard.

  • @imacdonald99
    @imacdonald99 วันที่ผ่านมา

    Essential for testing insulated heating elements, such as in ovens, grills etc. when finding faults that trip earth leakage breakers.

  • @winner1338
    @winner1338 2 หลายเดือนก่อน +3

    This is the best vdo. I always wanted to see this kind of test with explanation.

  • @theelectricianguy
    @theelectricianguy ปีที่แล้ว +4

    Awesome video, very knowledgeable information

  • @safetythirdified
    @safetythirdified ปีที่แล้ว +4

    I will be using this to teach my class.

  • @Badtxv
    @Badtxv 2 ปีที่แล้ว +3

    This is an awesome video I learnt some things thanks and good job man

  • @droodpvp
    @droodpvp 9 หลายเดือนก่อน +2

    Great video!! helped me understand this more! I do have a question that I believe this issue applies too, I dont know if you could help. I currently have an issue of a motherboard continually getting damaged and I believe it is the power coming in, but it reads a steady 120v. This is an outdoor application for an automated gate operator. It seems to run fine with no added features/ other wires connected to the system.
    When I wire a 12vdc or a 24vdc plug in transformer to an outlet that is getting power from the same source as the operator, I have normal voltage on the power wires (12vdc or 24vdc). But the dry contact wires that should read no voltage actually give off 10-15v (ac) from wire to ground. I do not have a megger currently but will be getting one to test the incoming 120v power.
    What you have described in your video sound like the incoming power is leaking voltage into the ground. Is it possible these wires that should be carrying no current are getting some AC voltage from the leakage? I have replaced the motherboard 5 times and the external devices 2 times and the communication wires 2 times. (Have not replaced or looked at the 120v line in the ground.
    I hope this is understandable, I am just desperate.

    • @TheElectriciansGuild
      @TheElectriciansGuild  8 หลายเดือนก่อน

      Hello. Sorry just seeing this now. There could be many reasons why you have a reading on the dry contact wire to ground. Without knowing more about the complete circuit, I would only be guessing at the cause. I hope you were able to figure it out!

  • @philipchristopher19
    @philipchristopher19 7 หลายเดือนก่อน +1

    This video is very informative
    Thanks

    • @TCASAnalytics
      @TCASAnalytics 6 หลายเดือนก่อน

      I know the amperage is tiny, but do Meggers present a risk of shock when they are testing at the higher, 1,000 VDC, settings? I've always been told that voltage burns, amperage kills, so low amperage notwithstanding, 1,000 VDC seems like a lotta burn is possible.

  • @Metal_seer
    @Metal_seer 3 หลายเดือนก่อน

    I want to compare the resistance of different wire connections (twist and headshrink, twist, solder, and heatshrink, clamp, and solder seal). Can I do this with an $80 megohmeter and two wires, or do I need a $1000 + megohmeter or even 4-wire Kelvin bridge?

  • @nlh8162
    @nlh8162 7 หลายเดือนก่อน +1

    I haven't used one in a long time. At work, they just bought a couple of the exact meter you have. Had a 50hp on an AHU, VFD going into earth fault. Started testing last night, and I diagnosed a bad VFD, this morning I'm told the motor is bad. Of course, I didn't see your video, I'm watching it again and I'll go up and do testing again, this time I'll be testing the wire to the motor and the motor. Is it possible wire with weak insulation causes the motor to short? we will see. VFD is isolated out of the circuit. It really helps me understand how best to use this meter. I was told the motor is bad if it tests below 100, I'm open to some input on this. Thanks, N.

    • @nlh8162
      @nlh8162 7 หลายเดือนก่อน

      Tested the wiring #4 going from the VFD to the motor just the insulation solid 4000 all 3 legs, Tested motor wirings 10-ish all 3 legs, tested motor to motor ground open. Looks like the windings are bad in the motor. So why the "Earth Fault " on the VFD. I think we still might have an issue with VFD.

  • @markcummings
    @markcummings ปีที่แล้ว +1

    Thank you, very well explained. Just curious. The greater than 1 MΩ acceptable reading, is it dependent on the cable, or voltage applied? Or no matter the case if I see this > 1MΩ I can confidently say the insulation is acceptable?

    • @TheElectriciansGuild
      @TheElectriciansGuild  ปีที่แล้ว +1

      My experience and understanding is with systems up to 600v, you should be in good shape at that value up to that voltage at least. Above that voltage, I really can’t speak confidently.

    • @markcummings
      @markcummings ปีที่แล้ว

      Thank you. @@TheElectriciansGuild

    • @humz403
      @humz403 9 หลายเดือนก่อน

      Neta testing standards would fail anything under 100Mohm. Any cable in good shape should read well above the 5Gohm max reading of this meter.
      Anytime we see under 100Mohms, we know the cable insulation has been subject to damage and/or significant moisture.
      I have seen cables tests in the 1-2mohm range, that have caused intermittent trips during higher moisture periods.
      Alot of it is common sense. If it's a major distribution cable, error on the side of caution and adhere to engineered standards like NETA. Is it a 120v branch circuit for a plug? You're probably fine to leave a cable testing at a couple Megaohms for a long time.

    • @BuzzElectricLlc
      @BuzzElectricLlc หลายเดือนก่อน

      ​@TheElectriciansGuild I just used the list meter and the when performing megger test the value increases ( slowly )up to 4 mega ohms. Does that indicate anything with the value rising slowly?

  • @danielclark3761
    @danielclark3761 4 หลายเดือนก่อน

    When carrying out this test, would you keep the test button in until it equalises? I was told to just hold it and let go soon as you see a reading?

    • @TheElectriciansGuild
      @TheElectriciansGuild  3 หลายเดือนก่อน

      It’s been a long time since I made this video and used the tester, so my memory is kinda foggy on that now. I would imagine it’s specific to the tool and setting.

  • @humz403
    @humz403 9 หลายเดือนก่อน +1

    Just to add several things. While the Megger guide is good for understanding the theory, your better off using engineered standard in terms of numbers.
    Ex. Neta standard has a 600v cable to be tested at 1000V and it should be a minimum of 100Mohms.
    1000vdc megger does not damage 600v insulation, as it is non destructive for a short period, with very small amounts of current. Using the highest recommended test voltage is best to measure leakage current to test insulation resistance.

  • @anthonymaccagnano1519
    @anthonymaccagnano1519 2 ปีที่แล้ว +1

    Great presentation.

  • @mingovazquez704
    @mingovazquez704 ปีที่แล้ว +2

    Thank you sir, for great information 👍

  • @joetyrrell1984
    @joetyrrell1984 10 หลายเดือนก่อน

    Not familiar with the process of using a megger. Was requested to do a megger test on all the circuits in a home that had fire damage. I just so happen to have just purchased this exact megger you are using in the video.
    I'm surprised Klein does not have any kind of tutorial for this tester.
    I found your video extremely helpful.
    Thank you very much!
    PS: do I need to test between hot to a grounded conductor / neutral to a grounded conductor? Or does the test work with none of the conductors actually providing a return path to the Earth (as you show in the video)?
    Some videos seem to show tying the hot and neutral together, and testing between those and ground.

    • @TheElectriciansGuild
      @TheElectriciansGuild  10 หลายเดือนก่อน

      Yeah if you tied neutral and hot together, if that neutral was still bonded, they wouldn’t get an effective insulation test from either of those conductors to ground. So I’d assume they isolate neutral from its bond prior to performing the test.
      But the test can be done to look for leakage currents between any two conductors. Just be sure to isolate the conductors you are testing so that you are testing a current path thru insulation, and not other return paths.
      Good luck!

    • @G7OEA
      @G7OEA 10 หลายเดือนก่อน

      This is a video showing electrical students in the UK how to do an installation resistance test to BS7671, which are the UK electrical regulations. The test values may be different to those in the usa but the test process is the same.
      th-cam.com/video/Ek1u2RjQffU/w-d-xo.htmlsi=80VhNEjADdjD-5JQ

  • @Itsthatoneguy371
    @Itsthatoneguy371 2 ปีที่แล้ว +2

    Learned a lot. Thank you!

  •  ปีที่แล้ว +8

    Your math is not correct. The insulation is mesured at 500V and not at 110V. Therefore insulation resistance is not same at 110V as at 500V and, consequently, leak current will be different at 110V.

    • @TheElectriciansGuild
      @TheElectriciansGuild  ปีที่แล้ว +1

      Resistance is a constant.

    • @TheElectriciansGuild
      @TheElectriciansGuild  ปีที่แล้ว +6

      So what you say is sort of right and sort of not. Insulation resistance, will remain constant, effected mainly by environmental effects such as heat or moisture. Application of a lower or higher voltage will not change the resistance, but it will result in lower or higher currents that could flow thru said resistor.

    • @rodgraff1782
      @rodgraff1782 ปีที่แล้ว +3

      @@TheElectriciansGuild Resistance varies with the temperature of the circuit. Take a heating element and measure its resistance when it is hot, just as you disconnect it from power, then check it when it is cold. As the ambient temperature rises, or the wire itself becomes hot, the resistance rises because the copper electrons are farther apart. If the wire is cold, the electrons move closer together and the resistance is lower. I like the hand crank generator type meggers rather than the battery powered ones. DC voltage of 1000 volts will not be damage the insulation on 600 volt rated wire. Neither will it damage motors that are rated at 460. In fact you should test motors at twice their operating voltage. It says right inside the instruction book of my AMEC crank style meggers..

    • @skillworldwide
      @skillworldwide ปีที่แล้ว +2

      bro,simulations only.

    • @lindsayruddock9141
      @lindsayruddock9141 11 หลายเดือนก่อน

      if insulation resistance was constant with voltage as you say, then why bother to measure at 500V, an ordinary ohm-meter would do@@TheElectriciansGuild

  • @kylegratton6065
    @kylegratton6065 9 หลายเดือนก่อน

    10/10 !!

  • @LR92327
    @LR92327 9 หลายเดือนก่อน

    I was taught to never megger anything at a voltage higher than the voltage rating of the insulation. You can cause insulation failure. When meggering a motor you can’t exceed the volts per turn rating of the motor.

  • @jamesgwaltney303
    @jamesgwaltney303 ปีที่แล้ว +1

    Thank you for the video

  • @lewistreloar2312
    @lewistreloar2312 ปีที่แล้ว +1

    This is is crazy that in the US you don’t use these everyday.
    In Australia and most of the world it’s mandatory to use this on every circuit you do any work on.

    • @TheElectriciansGuild
      @TheElectriciansGuild  ปีที่แล้ว

      I think I’ve seen some videos of European countries using them for inspections.
      Yeah I agree, for at least circuits of certain voltages, or were installed under strain.

    • @rodgraff1782
      @rodgraff1782 ปีที่แล้ว

      It is common practice on annual maintenance on large chillers used in HVAC,to Meg all compressor windings, and all pump motors. It is also valuable tool for nuisance trips of GFI protected circuits, to detect small current leakage under operating voltage. I always taught megger testing in my HVAC classes.

  • @maysasaeed7964
    @maysasaeed7964 4 หลายเดือนก่อน

    Why he put the wire in water??

    • @chucklanman3315
      @chucklanman3315 4 หลายเดือนก่อน +1

      If there is damage on the wire insulation. The water will cause a reading that says the cable is bad.

    • @willj7663
      @willj7663 4 หลายเดือนก่อน

      To simulate wires being the ground which is how some grounded systems have some conductors in their system outside. Usually damaged by lightning storms

    • @TheElectriciansGuild
      @TheElectriciansGuild  2 หลายเดือนก่อน

      So, the reason we care about insulation, is because is prevents current flow where we don’t want it.
      If we have damaged insulation, and that damage is not in contact with something conductive (water, other metals, air at high voltages, etc) then it’s not going to be a noticeable or even measurable problem.
      By putting it in water, I simulate a situation where a path for current flow is introduced between the damaged insulation. Producing a measurable result.

  • @Gregtman502
    @Gregtman502 9 หลายเดือนก่อน +1

    Don't forget lead to ground, he doing lead to lead

    • @TheElectriciansGuild
      @TheElectriciansGuild  2 หลายเดือนก่อน

      Yeah I wonder if lead to lead was even necessary in practice. If we have a leak to ground that’s kind of enough to know we have an issue.
      Sometimes I can be a little extra 🤣
      But then again, we might need to test lead to lead for phase faults. So maybe I’m not too extra.

  • @G7OEA
    @G7OEA 11 หลายเดือนก่อน

    Megga is a brand that made some of the earliest elextrical resistance testers. Doing a megga test is the slang for testing the electrical resistance between two conductors. But I agree with @lewistreloar2312 it sis utter madness that you dont test your circuits before you commission them. In the UK we aslo test for the earth bonding impedance. Dont get me started on the lack of PVC sleeving on the earthing conductors and the worlks if issues not sleveng them can cause.

    • @TheElectriciansGuild
      @TheElectriciansGuild  10 หลายเดือนก่อน

      It’s amazing that the entire USA isn’t on fire for not doing this! Eek gads! 😂

  • @jrh86
    @jrh86 ปีที่แล้ว

    I can't hear you😂