Transfer Girder with Floating Column 🔥 | Reinforcement Checking at Site | Hosur | Kavin Associates

แชร์
ฝัง
  • เผยแพร่เมื่อ 16 ก.ย. 2024
  • #home #homeconstruction #building #kavinassociates
    CONTRACTOR:
    Name : Er.Nirmal B.E
    Company Name : New Tech Construction
    Contact No : 9894837129
    He is doing building contract work & interior work in and around hosur & bangalore region. Interested can call the above number for more details...
    WATCH OUR LATEST VIDEOS:
    Nibav Vacuum Lift For Home 🔥 | Make your Home Luxury 😍 | Complete Tour and Customer feedback 😱 | KA - LINK - • Nibav Vacuum Lift For ...
    ₹2.15கால் லட்சம்னா சும்மாவா🔥| Live Testing at Site ✅ Using Original Schmidt Live Rebound Hammer - LINK - • ₹2.15கால் லட்சம்னா சும...
    WATCH OUR LATEST REPAIR SERIES VIDEOS :
    1.Column Strengthening Using Carbon Fiber Wrapping | Repair of Fully Corroded Column | Micro Concrete - LINK - • Column Strengthening U...
    2.𝗕𝗲𝗮𝗺 𝗦𝘁𝗿𝗲𝗻𝗴𝘁𝗵𝗲𝗻𝗶𝗻𝗴 𝗨𝘀𝗶𝗻𝗴 𝗖𝗮𝗿𝗯𝗼𝗻 𝗙𝗶𝗯𝗲𝗿 𝗪𝗿𝗮𝗽𝗽𝗶𝗻𝗴 😱 | Beam Cracks Problem Solved ✅ | Kavin Associates - LINK - • 𝗕𝗲𝗮𝗺 𝗦𝘁𝗿𝗲𝗻𝗴𝘁𝗵𝗲𝗻𝗶𝗻𝗴 𝗨𝘀𝗶...
    3.வீட்டில் வரும் Wall Dampness-ஐ தடுக்கும் முறை 😱 | 100 % Solution | Repair Series | Kavin Associates - LINK - • வீட்டில் வரும் Wall Da...
    4.Terrace Floor-ல் வரும் Cracks, Water Leakage-ஐ எப்படித் தீர்ப்பது ? | PU Injection Method | 100% - LINK - • Terrace Floor-ல் வரும்...
    For Business Enquiry, Collaboration & Promotion - WhatsApp me - 9994087571
    Camera used for shoot - #iphone13promax
    App used for editing - #vneditor & #canva
    #youtube #youtubechannel
    If you like this video - Like, share and subscribe to my TH-cam channel... LINK - / kavinassociates
    Share this knowledge to your friends and learn new things everyday and make your skill stronger...
    Follow me - / kavinassoci. .
    Like me - / kavin1011
    FOR QUERIES & DETAILS: Mail us at - kavinprivin5@gmail.com
    #housedesign #homeconstruction #homeideas #construction #building #hometips

ความคิดเห็น • 95

  • @janasanjay1227
    @janasanjay1227 ปีที่แล้ว +7

    Very informative sir.... column are cranked opposite to achieve hinge action so that the floating column only allows to transfer axial force and not moment and beams are given sufficient depth to avoid punching failure.

  • @venkataramananp3915
    @venkataramananp3915 4 หลายเดือนก่อน +1

    Excellent, bar bending reinforcement work.

  • @bharathy8234
    @bharathy8234 ปีที่แล้ว +2

    Inspirational video, i never seen practically floating column with transfer girder. Just studied in books. But this video makes lot of sence to me brother. Thank you brother Thank you so much 🎉

  • @MrPearllotus
    @MrPearllotus ปีที่แล้ว +2

    Very informative and friendly explanation, lovely attitude from engineer. As a civil engineer I feel proud to say your channel is a reference tool for me and your the voice முடியுமே literally sounds energetic and giving confidence towards work 🤝🏼

    • @KavinAssociatesOfficial
      @KavinAssociatesOfficial  ปีที่แล้ว +1

      Thank you so much sir 😊 share our videos to your frnds

    • @MrPearllotus
      @MrPearllotus ปีที่แล้ว

      @@KavinAssociatesOfficial sure sir 🤝🏼

  • @SuryaPrakash-tr8yb
    @SuryaPrakash-tr8yb 5 หลายเดือนก่อน +1

    Yes !! Seeing yu both speaking oru spro oduthu mandaikulla😀

  • @merrilheysan2089
    @merrilheysan2089 ปีที่แล้ว +1

    Very Valuuable information bro........
    Thank you so much......

  • @ganapathycivil9872
    @ganapathycivil9872 ปีที่แล้ว +1

    Vera level video sur, thanks a lot and post a lot 😅❤

  • @muruganp6166
    @muruganp6166 ปีที่แล้ว +1

    Very useful video for me thank you sir rompa nantri

  • @arsathayub4890
    @arsathayub4890 ปีที่แล้ว +1

    Bro very useful 👍
    Please make more like this

  • @mgtech7432
    @mgtech7432 ปีที่แล้ว +1

    Very good explanation sir* heartly thanks 👌

  • @Pradeep-vl5yf
    @Pradeep-vl5yf ปีที่แล้ว +1

    Bro, one doubt. In fixed beam, end and span moments varies but why the reinforcement is same in both top end and mid bottom.

  • @gowthamiv2760
    @gowthamiv2760 ปีที่แล้ว +1

    அருமை! அருமை!

  • @dhanasekaran3010
    @dhanasekaran3010 ปีที่แล้ว +2

    Super Sir👍

  • @tejgautham4628
    @tejgautham4628 ปีที่แล้ว +1

    Bracket column pathi sonengala bro athu detailed solunga ,,,, torsion design pathi

  • @KumarKumar-fo5wt
    @KumarKumar-fo5wt ปีที่แล้ว +2

    Super sir

  • @venugopalk3276
    @venugopalk3276 10 หลายเดือนก่อน +1

    Very nice 👍

  • @hihi-wm9xb
    @hihi-wm9xb ปีที่แล้ว +1

    very informataive

  • @sathiskumars4502
    @sathiskumars4502 ปีที่แล้ว

    Very Informative video. Thanks for bringing that. Is the building structure also designed for seismic loads along with gravity loads? As per IS1893-part 1-2016, there shouldn't be any vertical irregularities present in the building like floating columns when designing a structure for seismic effect. Please clarify. Thanks

  • @sulochanajeganjegan9655
    @sulochanajeganjegan9655 ปีที่แล้ว +1

    🎉 good view

  • @davidsahayaraj8811
    @davidsahayaraj8811 ปีที่แล้ว +1

    Nice and useful information 🤝

  • @jpradeepraj
    @jpradeepraj 10 หลายเดือนก่อน

    Hello sir, even in normal columns, joggling is not advisable, but this way of floating column (the X portion) shows extreme joggling, how is this good?

  • @mohammedismail-lx2dq
    @mohammedismail-lx2dq ปีที่แล้ว

    Rombanaal kku apm naala civil channel❤❤❤❤

  • @Prakash_Govindharaji
    @Prakash_Govindharaji ปีที่แล้ว +1

    Thank you sir

  • @amirthalinkam5104
    @amirthalinkam5104 ปีที่แล้ว +2

    Super

  • @AjithKumar-sv6kk
    @AjithKumar-sv6kk ปีที่แล้ว +1

    Sir BIM concept video make pannunga

  • @larulprakash5952
    @larulprakash5952 ปีที่แล้ว

    Super sir , good explanation 👍

  • @sudhakars9222
    @sudhakars9222 ปีที่แล้ว

    Informative sir. Wondering about 4 floors column load carried by single beam. Need any side face reinforcement above 2 feet depth of beam sir?

  • @muruganp6166
    @muruganp6166 ปีที่แล้ว +1

    Sir roofla water tank load eppadi kodukkalam

  • @ilanchezhian7071
    @ilanchezhian7071 ปีที่แล้ว

    the beam reinforcement is not parallel and its like one end is at the bottom and another end is at the top of transfer girder , can you explain why it was designed in this manner

  • @mohanraj7537
    @mohanraj7537 ปีที่แล้ว +1

    🎉 super sir

  • @AlaguVignesh
    @AlaguVignesh ปีที่แล้ว

    Floating column in transfer grider details -
    which code book ?
    Kindly mention

  • @sakthivels9574
    @sakthivels9574 ปีที่แล้ว +1

    👍 super bro

  • @ajaymanikaprakash3272
    @ajaymanikaprakash3272 ปีที่แล้ว

    Transform Girder floting column junction detailing code book and clause number sollunga brother

  • @eswaransumathi3868
    @eswaransumathi3868 ปีที่แล้ว +1

    Subar பிரதர்

  • @nvdhamodaranrc8637
    @nvdhamodaranrc8637 ปีที่แล้ว +1

    Suprb sir

  • @prabinjebav3928
    @prabinjebav3928 ปีที่แล้ว

    Sir, cantilever beam oda rod ku development length neeti vidaama ata end la just 'L' mattum Pani vidurathi recommended method thana

  • @gowthamiv4841
    @gowthamiv4841 ปีที่แล้ว

    Haunch bar dia didn't mentioned and as well as secondary beam as well as main beam junction top bars didn't tell the details..

    • @gowthamiv4841
      @gowthamiv4841 ปีที่แล้ว

      Can you provide special video in this?

  • @saravanan.engineer3630
    @saravanan.engineer3630 ปีที่แล้ว

    Useful one sir

  • @user-up7bh3ut8q
    @user-up7bh3ut8q ปีที่แล้ว +1

    Does 2 legged stirrups statisfied for transfer beam

  • @sonnapuriyaathu
    @sonnapuriyaathu ปีที่แล้ว

    Thanks bro ❤

  • @AjithKumar-sv6kk
    @AjithKumar-sv6kk ปีที่แล้ว +1

    Sir which software you use in reinforcement design?

  • @reojoan1546
    @reojoan1546 ปีที่แล้ว

    Whats IS code for transfer girder sir?

  • @manjumist2635
    @manjumist2635 ปีที่แล้ว

    Verum 2L ring mattum potrukanga..?

  • @HosurTV
    @HosurTV ปีที่แล้ว +1

    nice

  • @karthikrajendran354
    @karthikrajendran354 ปีที่แล้ว +1

    (Elevation + plan ) work pannuvingala sir

  • @shieksspace
    @shieksspace ปีที่แล้ว

    4:56 is that concept of moment release on secondary beams ?

    • @atifnawaz7623
      @atifnawaz7623 ปีที่แล้ว

      No. that is normal detailing when secondary beam meets a main beam.

  • @PraveenKumar-cc3fs
    @PraveenKumar-cc3fs ปีที่แล้ว

    Sq.ft evlo sir pandringa intha project😮

  • @MohamedAlfaiz95
    @MohamedAlfaiz95 ปีที่แล้ว +1

    Floating column code Book details

  • @chansdcreation
    @chansdcreation ปีที่แล้ว +1

    Bro civil engineering student ku design course statt pro, revit course details solluga bro

  • @ramajayakumartr8363
    @ramajayakumartr8363 ปีที่แล้ว

    Hi sir, vaccancy irukkuma sir

  • @chinnappasconstruction0809
    @chinnappasconstruction0809 ปีที่แล้ว

    hlo Mr.kavin. transfer girder ku pathila an PT beams use pannalaama? athu helpfull ah irukkuma

  • @rajubhaibangbang
    @rajubhaibangbang ปีที่แล้ว +1

    VIP DHANUS MARRIYE THUMBNAIL

  • @ManiGandan
    @ManiGandan ปีที่แล้ว

    Plan show us

  • @GamingLoozer
    @GamingLoozer ปีที่แล้ว

    8:45 Minimum & maximum evvalavu Space kulla veikka ealum?? ( Feet )

  • @srishanmugaconstruction584
    @srishanmugaconstruction584 ปีที่แล้ว +1

    Useful information 👍🏻👍🏻👍🏻👍🏻

  • @MAHA6690
    @MAHA6690 ปีที่แล้ว +1

    super sir