Post Tensioned Beam Installation Procedure at Site 🔥 | Components of PT Beam | Kavin Associates

แชร์
ฝัง
  • เผยแพร่เมื่อ 11 พ.ค. 2023
  • #construction #home #beam #kavinassociates
    For PT works Contact:
    SF Engineering India (System) Pvt Ltd,Chennai
    9790921280
    They are doing PT Works all over India & Abroad at reasonable price.
    Ground Water Table Problem Solved ✅ | Types of Pedestal | When to go for PT Beam Designing ?
    - LINK - • Ground Water Table Pro...
    WATCH OUR LATEST VIDEOS:
    Transfer Girder with Floating Column 🔥 | Reinforcement Checking at Site | Hosur | Kavin Associates - LINK- • Transfer Girder with F...
    Nibav Vacuum Lift For Home 🔥 | Make your Home Luxury 😍 | Complete Tour and Customer feedback 😱 | KA - LINK - • Nibav Vacuum Lift For ...
    ₹2.15கால் லட்சம்னா சும்மாவா🔥| Live Testing at Site ✅ Using Original Schmidt Live Rebound Hammer - LINK - • ₹2.15கால் லட்சம்னா சும...
    WATCH OUR LATEST REPAIR SERIES VIDEOS :
    1.Column Strengthening Using Carbon Fiber Wrapping | Repair of Fully Corroded Column | Micro Concrete - LINK - • Column Strengthening U...
    2.வீட்டில் வரும் Wall Dampness-ஐ தடுக்கும் முறை 😱 | 100 % Solution | Repair Series | Kavin Associates - LINK - • வீட்டில் வரும் Wall Da...
    3.Terrace Floor-ல் வரும் Cracks, Water Leakage-ஐ எப்படித் தீர்ப்பது ? | PU Injection Method | 100% - LINK - • Terrace Floor-ல் வரும்...
    For Business Enquiry, Collaboration & Promotion - WhatsApp me - 9994087571
    Camera used for shoot - #iphone13promax
    App used for editing - #vneditor & #canva
    #youtube #youtubechannel
    If you like this video - Like, share and subscribe to my TH-cam channel... LINK - / kavinassociates
    Share this knowledge to your friends and learn new things everyday and make your skill stronger...
    Follow me - / kavinassoci. .
    Like me - / kavin1011
    FOR QUERIES & DETAILS: Mail us at - kavinprivin5@gmail.com
    #housedesign #homeconstruction #homeideas #construction #building #hometips
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 72

  • @janasanjay1227
    @janasanjay1227 ปีที่แล้ว +10

    Very Informative sir....The shape of tendon profile is given based on the BENDING MOMENT of the BEAM and Tendons are given based on calculating the losses due to the Post tensioning and also the PT increases the life span of structure while tensioning of beam rod.

  • @praveenraj519
    @praveenraj519 ปีที่แล้ว +1

    Very much interested to learn and execute your ideas in construction field sir. Myself is an civil engineer. I have been watching all your videos regularly. Recently i have executed the same idea for pedestal footing by watching your vedio sir. Thank you for sharing your knowledge with us. Keep going sir😊.. We all will support you😊

  • @prasannabs3975
    @prasannabs3975 5 หลายเดือนก่อน +1

    Thank you sir very useful with clear instructions 👍

  • @arulprakash3341
    @arulprakash3341 ปีที่แล้ว +1

    Very use full site video sir
    PT structure beam
    Tq so much sir

  • @nvdhamodaranrc8637
    @nvdhamodaranrc8637 ปีที่แล้ว +1

    Very great effert educative and informative for all junior level well done sir
    I had done it

  • @navaneethakrishnan.rnavane2053
    @navaneethakrishnan.rnavane2053 2 หลายเดือนก่อน +1

    Ultimate தலைவா....Such a Great. Person Always

  • @muthuNeweast-wy6vw
    @muthuNeweast-wy6vw ปีที่แล้ว +1

    Very useful information sir. Sir if any code book for pt slab and beam

  • @mohammedismail-lx2dq
    @mohammedismail-lx2dq ปีที่แล้ว +1

    super always ultimate good video and editing bro post more videos

  • @sivakrishnaduddu4592
    @sivakrishnaduddu4592 ปีที่แล้ว +1

    You doing great job sir ❤

  • @ABDULRAHIM-de2ed
    @ABDULRAHIM-de2ed หลายเดือนก่อน

    Min cube strength cube for stressing is 25 mpa as per British standard

  • @civil007manickavelt5
    @civil007manickavelt5 ปีที่แล้ว +1

    Useful content 👏

  • @mokshithkrishna604
    @mokshithkrishna604 ปีที่แล้ว +1

    Speach sound very Low sir. But good message.

  • @krantikumar268
    @krantikumar268 ปีที่แล้ว +1

    Hi Kavin Sir,
    Please provide level 1,2,3 course material in book form ??

  • @user-no5dw9ux4p
    @user-no5dw9ux4p 4 หลายเดือนก่อน +1

    Nice explanation

  • @arulvasanthi
    @arulvasanthi ปีที่แล้ว +1

    Super brother, i am also a civil engineer.

  • @prakashk7684
    @prakashk7684 ปีที่แล้ว +1

    Good information 👍

  • @lragavendiran8187
    @lragavendiran8187 2 หลายเดือนก่อน +1

    Thank you. Voice too low at the end of video not audible

  • @Askar_vlogs
    @Askar_vlogs ปีที่แล้ว

    GI pipe length enthana Feet varum...
    Live endla joint panni antha tendons minimum length evlo Veliya irkanum bro

  • @KumarKumar-fo5wt
    @KumarKumar-fo5wt ปีที่แล้ว +1

    Super sir

  • @muthuNeweast-wy6vw
    @muthuNeweast-wy6vw ปีที่แล้ว

    And sir Antha floating column purpose enna nu sollalaye .

  • @advancedautocaddynamicbloc7359
    @advancedautocaddynamicbloc7359 10 หลายเดือนก่อน +1

    New information

  • @Profit_Momo_Pdf-File
    @Profit_Momo_Pdf-File 3 หลายเดือนก่อน +1

    next level stuff

  • @velladurai.sdurai8928
    @velladurai.sdurai8928 8 หลายเดือนก่อน

    PT slab video please

  • @jamasilamani
    @jamasilamani ปีที่แล้ว +1

    Brother 20mm rodla belt. 12 mm rod coloum podalama? Plz sollunga.

  • @sivakrishnaduddu4592
    @sivakrishnaduddu4592 ปีที่แล้ว

    One more doubt sir, i had heard that incase of PT Slabs the concrete should attain 80% of its grade strength at the end of 7 days in order to do PT
    Is it true sir??

  • @bavash100ul
    @bavash100ul ปีที่แล้ว

    I presume , tendon covering ku use pannathu GI illa flexible duct sleeve nu

  • @ramyarishi6675
    @ramyarishi6675 9 หลายเดือนก่อน

    Sir roof la beam podamal katti irunthal atharku ethana floor max eduka mudium sir

    • @KavinAssociatesOfficial
      @KavinAssociatesOfficial  9 หลายเดือนก่อน

      It’s depends on your building strength…have to check

  • @9487645723
    @9487645723 ปีที่แล้ว +5

    Thank you for your efforts in making very detailed videos. Learning a lot from your videos. 😊

  • @prabhakaranganapathy34
    @prabhakaranganapathy34 3 หลายเดือนก่อน +1

    Sir pls give me a explanation, in some of the engineering videos saying near beam column joints beam rods should be cracked and to be inside the column ne is it right ? pls urgent

    • @KavinAssociatesOfficial
      @KavinAssociatesOfficial  3 หลายเดือนก่อน

      Only 12,16 mm rods can be taken outside of column…because of larger dia like 20,25 mm rods it should be cracked into column then only you can get cover for column…so only if column rods are more congestion it’s necessary to increase the column width

    • @prabhakaranganapathy34
      @prabhakaranganapathy34 3 หลายเดือนก่อน

      @@KavinAssociatesOfficial thank you so much

  • @rav8472
    @rav8472 ปีที่แล้ว

    Is that possible in clay soil.... Lower level sbc clay soil

    • @geodamin8351
      @geodamin8351 ปีที่แล้ว

      Soil type does not have any influence on the PT system.

  • @vasuinba
    @vasuinba ปีที่แล้ว +1

    I studied in my bachelor's degree minimums grade of concrete should be grater than M40 So please confirm again as per IS Code

    • @DarshanDarshan-ns6yu
      @DarshanDarshan-ns6yu ปีที่แล้ว +1

      M40 grade for pre-tensioning
      but here for post-tensioned beam mini grade M30
      🙂

    • @gowthamarmstrong8981
      @gowthamarmstrong8981 ปีที่แล้ว +1

      M35 is the starting grade to be used in PT works bro

  • @Prasob-pc8uu
    @Prasob-pc8uu ปีที่แล้ว +1

    Job vaccancy eruka sir

  • @dubailomiteluguabbai3971
    @dubailomiteluguabbai3971 ปีที่แล้ว +1

    I want to construct 60 feet long beam between 2pillars. How many steel bars should I use, and what size of requisite
    between two pillars is 60 feet span possible...?
    reply bro please
    single floor 40 feet hight slab

    • @KavinAssociatesOfficial
      @KavinAssociatesOfficial  ปีที่แล้ว +1

      It’s possible only in PT not in conventional beam sir …

    • @dubailomiteluguabbai3971
      @dubailomiteluguabbai3971 ปีที่แล้ว

      @@KavinAssociatesOfficial thank u bro
      what is the cost for 60×40 plan design....?
      kindly can you send what's app number

  • @user-hd1ui8om3o
    @user-hd1ui8om3o 11 หลายเดือนก่อน

    Inside GI pipe it is rope not rod

  • @ruby40483
    @ruby40483 ปีที่แล้ว +1

    Bro...apo PT beam oda load transfer conventional column laye pannuvangla...

  • @amthanamuthan1201
    @amthanamuthan1201 ปีที่แล้ว +1

    In market 12.2m lengths of rod only available how to active 42feet rod

    • @ManiGandan
      @ManiGandan ปีที่แล้ว +1

      Special length can be bought by ordering specific length from the steel company

    • @geodamin8351
      @geodamin8351 ปีที่แล้ว

      Bars will be lapped at appropriate locations for larger spans

  • @kannadhasant1396
    @kannadhasant1396 ปีที่แล้ว +2

    How many floor will do same way

  • @user-lg4lj5xg5m
    @user-lg4lj5xg5m 6 หลายเดือนก่อน

    This work five year i am working Singapore job vacancy sir

  • @sanjayputtesh2269
    @sanjayputtesh2269 5 หลายเดือนก่อน

    1 rod length is 39 feet ,how 42feet single rod laid?

    • @KavinAssociatesOfficial
      @KavinAssociatesOfficial  5 หลายเดือนก่อน

      In market if you order they will supply single reinforcement

  • @naazim4297
    @naazim4297 ปีที่แล้ว +1

    Mos, dos , ippo Dan puriyidu .

  • @ArunKumar-bz3dw
    @ArunKumar-bz3dw 5 หลายเดือนก่อน

    Reference is 1343

  • @Myk_mash
    @Myk_mash หลายเดือนก่อน

    Bro is walking on a site with crocs no safety shoe lol