  • always disconnect electric power. check contactor for line voltage for safety
    How to replace a air conditioning relay on the outside heat pump or condenser unit step by step instructions.
    showing where to hook up low voltage. line side voltage and load side power
    Thanks for watching!
    - David
    David@DavidJonesAC.com
    Follow me on Facebook: / david-jones-ac-1010702...

ความคิดเห็น • 22

  • @edrekampoz4036
    @edrekampoz4036 4 ปีที่แล้ว +2

    It was a very helpful video, thank you very much

  • @TheWilferch
    @TheWilferch ปีที่แล้ว +1

    You can also turn off the main breaker of the "air-handler" unit....or even turn the indoor thermostat to "off".....as an extra precaution to kill the 24V power...so you don't need the tape.

  • @jonesacnaples
    @jonesacnaples  11 ปีที่แล้ว +1

    You are right good catch, I had checked voltage earlier to make sure it was off. Thanks for the comment .

  • @Eddy63
    @Eddy63 7 ปีที่แล้ว +2

    Another good educational video . That's a good tip for taping the 24v spades ... very easy
    to blow xformer .

    • @jonesacnaples
      @jonesacnaples  7 ปีที่แล้ว

      I know from experience

    • @lcglazer
      @lcglazer 2 หลายเดือนก่อน

      My 24 volt 2 pole contactor does not say which way is up and which way is down? Everything about looks absolutely symmetrical, except the sticker on one side with the details.

  • @mts7274
    @mts7274 ปีที่แล้ว +1

    How do you know which side is the "line in" on a contactor like that? I don't think those types are ever labeled.

  • @jimbola77
    @jimbola77 8 ปีที่แล้ว

    nice video explanation I was waiting for you to show a relay but great anyway!!!

  • @mick854231
    @mick854231 11 ปีที่แล้ว +4

    The clamp meter is set to amps not volts A/C when he tested the contractor

    • @sean-bz7gw
      @sean-bz7gw 7 หลายเดือนก่อน

      Haha I caught that too!

  • @padnekad
    @padnekad 15 วันที่ผ่านมา

    Hi sir
    My split ac out door unit not working i changed capacitor
    Same thing once comperssor start few second cut off
    Nothin to work fan or comperssor
    What soulution

  • @jonesacnaples
    @jonesacnaples  11 ปีที่แล้ว

    Thank you my friend, I hope it helps.

  • @kentotzz
    @kentotzz 7 ปีที่แล้ว +1

    Question: I change my contactor but it doesn't pull automatically .. what should I do . Thanks

  • @arturoalzamora7575
    @arturoalzamora7575 ปีที่แล้ว

    very good

  • @15901111
    @15901111 11 ปีที่แล้ว +1

    Good video man !!!!!

  • @ronaldclark8187
    @ronaldclark8187 6 ปีที่แล้ว

    Replace a single pole contactor to a double pole.What about the trickle circuit. Does it have a crank case heater?
    The capacitor in a box is not good for heat dissipation.

  • @ericems2
    @ericems2 ปีที่แล้ว

    What makes them go bad ? Mine was stuck closed ? TY

  • @tommy-ul2yy
    @tommy-ul2yy 8 ปีที่แล้ว

    is not that a consctactor instead of relay?

  • @anitasahani6133
    @anitasahani6133 7 ปีที่แล้ว +1

    bellu star contractare wayrigh