VFD Relay output Programming and Wiring| VFD Relay NO and NC Connection| VFD Internal Relay Setting|

แชร์
ฝัง
  • เผยแพร่เมื่อ 27 ส.ค. 2024
  • VFD Relay output Programming and Wiring| VFD Relay NO and NC Connection| VFD Internal Relay Setting|
    Variable frequency drive (Vfd) me internal Relay ka use kis kis function ke liye kar sakte he and uske liye vfd me programming and relay ka connection kese karte he vo Mene ye video me bataya he.
    Topic Discussed
    1) VFD relay output Settings
    2) VFD Internal Relay Programming and Wiring
    3) VFD Relay used for fault, Running, Frequency level reached,Ready,etc
    4) VFD Feedback signal
    5) VFD auxiliary Function
    Thanx For Watching
    If you have any questions please feel free to comment below.
    Please Like, Share and Subscribe.
    Mail: niceelectronics8831@gmail.com
    #Vfd #Relay #NoNc #VfdRelay #Relay #VfdFeedback

ความคิดเห็น • 41

  • @powergard2703
    @powergard2703 ปีที่แล้ว +1

    Very. Good your. Programing. Idai.

  • @powergard2703
    @powergard2703 ปีที่แล้ว

    Very. Helpful. New. Technical person

  • @sonaramdewasi156
    @sonaramdewasi156 4 ปีที่แล้ว +2

    Your video is very useful for me

    • @sonaramdewasi156
      @sonaramdewasi156 4 ปีที่แล้ว +1

      Sir,vfd me transistor output terminal ka kya use hai,Y1YE1

  • @AbdulHannan-ud7ht
    @AbdulHannan-ud7ht ปีที่แล้ว

    Very informative video😘😘

  • @VipinKumar-cv1ms
    @VipinKumar-cv1ms 4 ปีที่แล้ว +1

    Nice video sir 👌👌👌👌

  • @dulalhossain5127
    @dulalhossain5127 3 ปีที่แล้ว +1

    Nice video

  • @upendrasarraf3585
    @upendrasarraf3585 4 ปีที่แล้ว +1

    Super video

  • @muhammedrehan1590
    @muhammedrehan1590 2 ปีที่แล้ว

    Very good sir

  • @grow7up
    @grow7up 3 ปีที่แล้ว +1

    Mithubishi drive ka bi bataye pls

  • @mirzazeshanahmed7603
    @mirzazeshanahmed7603 4 ปีที่แล้ว +1

    Kindly make video on modbus communication vfd and plc

  • @maheshelectric95
    @maheshelectric95 3 ปีที่แล้ว

    सर शक्ति सोलर पंप पर लगने वाली simha vfd कि setting पर भी एक विडियो बनाये. 🙏🙏

  • @forcefieldyt
    @forcefieldyt 2 ปีที่แล้ว

    thanks ❤️

  • @upendramaurya6473
    @upendramaurya6473 ปีที่แล้ว

    Cropatan ka VFD vsx ka programi Hindi me esi tarh se

  • @ziaullah8020
    @ziaullah8020 หลายเดือนก่อน

    Sir VFD say 12v direct kesy nekalty hain

  • @khalipili2200
    @khalipili2200 4 ปีที่แล้ว +1

    Sir vfd external fault ke video banaye please

  • @runbou3485
    @runbou3485 ปีที่แล้ว

    Thankអរគុណ🙏

  • @punjabitruck8172
    @punjabitruck8172 ปีที่แล้ว +1

    Is really ka sath 3 phase bi use kar sakta hy kia

    • @niceelectronics9505
      @niceelectronics9505  ปีที่แล้ว

      Yes you can apply only one phase get output from it for controlling operations only. Because it's relay current capacity is low.

  • @rajesh1tech366
    @rajesh1tech366 3 ปีที่แล้ว

    L&T vfd ki relay parameter settings bataye please

  • @karunasagarpatel6634
    @karunasagarpatel6634 4 ปีที่แล้ว +1

    Sir kya fugi electric frenic mini se normar submersible pump run karsakte hain solar in put se?

    • @niceelectronics9505
      @niceelectronics9505  4 ปีที่แล้ว +1

      Ha ap VFD se submersible Pump run kar sakte ho..Magr uske according apko vfd me parameter set karne padege.. Like rpm , Motor frequency, Voltage, coast to stop etc as per your motor name plate..Thanx

  • @savinaykewat114
    @savinaykewat114 3 ปีที่แล้ว

    Vfd se vfd ka interlocking batiye bina contactor lagay mere pas ek delta drive hai or ek cg ka

  • @sonaramdewasi156
    @sonaramdewasi156 4 ปีที่แล้ว +2

    Sir, siemens vfd me relly ka peramiter kya hai

    • @niceelectronics9505
      @niceelectronics9505  4 ปีที่แล้ว

      Parameter no P0731, P0732, P0733 For Relay Output 1,2,3 setting.
      Set following according your requirement
      52.0 Drive ready 0 Closed
      52.1 Drive ready to run 0 Closed 52.2 Drive running 0 Closed
      52.3 Drive fault active 0 Closed 52.4 OFF2 active 1 Closed
      52.5 OFF3 active 1 Closed
      52.6 Switch on inhibit active 0 Closed
      52.7 Drive warning active 0 Closed
      52.8 Deviation setpoint/actual value 1 Closed
      52.9 PZD control (Process Data Control) 0 Closed
      52.A Maximum frequency reached 0 Closed
      52.B Warning: Motor current limit 1 Closed
      52.C Motor holding brake (MHB) active 0 Closed
      52.D Motor overload 1 Closed 52.E Motor running direction right 0 Closed
      52.F Inverter overload 1 Closed 53.0 DC brake active 0 Closed 53.1 Act. freq. f_act > P2167 (f_off) 0 Closed
      53.2 Act. freq. f_act P2170 0 Closed
      53.4 Act. freq. f_act > P2155 (f_1) 0 Closed
      53.5 Act. freq. f_act = setpoint 0 Closed 53.7 Act. Vdc r0026 < P2172 0 Closed
      53.8 Act. Vdc r0026 > P2172 0 Closed
      53.A PID output r2294 == P2292 (PID_min) 0 Closed
      53.B PID output r2294 == P2291 (PID_max) 0 Closed

  • @hangonafter9871
    @hangonafter9871 2 ปีที่แล้ว

    Can I use 250 volt AC fan instead of DC fan?

  • @rajendarkumar2108
    @rajendarkumar2108 3 ปีที่แล้ว

    Sir ji yahi settings yaskawa me btao please

  • @moinshekh5960
    @moinshekh5960 ปีที่แล้ว

    Sar aap kaha ke ho

  • @BasirahmadzaiAhmadzai
    @BasirahmadzaiAhmadzai ปีที่แล้ว

    Hello relay output kam nahi kardiya

  • @sonaramdewasi156
    @sonaramdewasi156 4 ปีที่แล้ว +1

    Sir, really ko timing set kese karte hai

    • @niceelectronics9505
      @niceelectronics9505  4 ปีที่แล้ว +1

      Sorry no function available for timing based on off for relay..But agar koi speed par jane par apko relay ko operate karwana he to vo function available he vfd me..

    • @sonaramdewasi156
      @sonaramdewasi156 4 ปีที่แล้ว +1

      Thanks for reply sir, vfd me timer ke similarly koi factions hai to bat sir, please

    • @niceelectronics9505
      @niceelectronics9505  4 ปีที่แล้ว +1

      Start on delay time and stopping delay time..Ki company ki vfd me ap ye time set kar sakte ho..

    • @sonaramdewasi156
      @sonaramdewasi156 4 ปีที่แล้ว

      Thanks for reply sir,Konsi vfd hai, sir jisme on/off delay tumer function hai , please

  • @ketanprajapati9938
    @ketanprajapati9938 3 ปีที่แล้ว +1

    Ye konsi drive hain

  • @prakashashoksonawane2221
    @prakashashoksonawane2221 ปีที่แล้ว +1

    सर
    INVT VFD POFF Error दिखा रही है
    मोटार solar 5.5 KW Pump जोडा है
    please sugg es t