VFD Relay output Programming and Wiring| VFD Relay NO and NC Connection| VFD Internal Relay Setting|
ฝัง
- เผยแพร่เมื่อ 27 ส.ค. 2024
- VFD Relay output Programming and Wiring| VFD Relay NO and NC Connection| VFD Internal Relay Setting|
Variable frequency drive (Vfd) me internal Relay ka use kis kis function ke liye kar sakte he and uske liye vfd me programming and relay ka connection kese karte he vo Mene ye video me bataya he.
Topic Discussed
1) VFD relay output Settings
2) VFD Internal Relay Programming and Wiring
3) VFD Relay used for fault, Running, Frequency level reached,Ready,etc
4) VFD Feedback signal
5) VFD auxiliary Function
Thanx For Watching
If you have any questions please feel free to comment below.
Please Like, Share and Subscribe.
Mail: niceelectronics8831@gmail.com
#Vfd #Relay #NoNc #VfdRelay #Relay #VfdFeedback
Very. Good your. Programing. Idai.
Very. Helpful. New. Technical person
Your video is very useful for me
Sir,vfd me transistor output terminal ka kya use hai,Y1YE1
Very informative video😘😘
Nice video sir 👌👌👌👌
Nice video
Super video
Very good sir
Mithubishi drive ka bi bataye pls
Kindly make video on modbus communication vfd and plc
सर शक्ति सोलर पंप पर लगने वाली simha vfd कि setting पर भी एक विडियो बनाये. 🙏🙏
thanks ❤️
Cropatan ka VFD vsx ka programi Hindi me esi tarh se
Sir VFD say 12v direct kesy nekalty hain
Sir vfd external fault ke video banaye please
Thankអរគុណ🙏
Is really ka sath 3 phase bi use kar sakta hy kia
Yes you can apply only one phase get output from it for controlling operations only. Because it's relay current capacity is low.
L&T vfd ki relay parameter settings bataye please
Sir kya fugi electric frenic mini se normar submersible pump run karsakte hain solar in put se?
Ha ap VFD se submersible Pump run kar sakte ho..Magr uske according apko vfd me parameter set karne padege.. Like rpm , Motor frequency, Voltage, coast to stop etc as per your motor name plate..Thanx
Vfd se vfd ka interlocking batiye bina contactor lagay mere pas ek delta drive hai or ek cg ka
Sir, siemens vfd me relly ka peramiter kya hai
Parameter no P0731, P0732, P0733 For Relay Output 1,2,3 setting.
Set following according your requirement
52.0 Drive ready 0 Closed
52.1 Drive ready to run 0 Closed 52.2 Drive running 0 Closed
52.3 Drive fault active 0 Closed 52.4 OFF2 active 1 Closed
52.5 OFF3 active 1 Closed
52.6 Switch on inhibit active 0 Closed
52.7 Drive warning active 0 Closed
52.8 Deviation setpoint/actual value 1 Closed
52.9 PZD control (Process Data Control) 0 Closed
52.A Maximum frequency reached 0 Closed
52.B Warning: Motor current limit 1 Closed
52.C Motor holding brake (MHB) active 0 Closed
52.D Motor overload 1 Closed 52.E Motor running direction right 0 Closed
52.F Inverter overload 1 Closed 53.0 DC brake active 0 Closed 53.1 Act. freq. f_act > P2167 (f_off) 0 Closed
53.2 Act. freq. f_act P2170 0 Closed
53.4 Act. freq. f_act > P2155 (f_1) 0 Closed
53.5 Act. freq. f_act = setpoint 0 Closed 53.7 Act. Vdc r0026 < P2172 0 Closed
53.8 Act. Vdc r0026 > P2172 0 Closed
53.A PID output r2294 == P2292 (PID_min) 0 Closed
53.B PID output r2294 == P2291 (PID_max) 0 Closed
Can I use 250 volt AC fan instead of DC fan?
Sir ji yahi settings yaskawa me btao please
Sar aap kaha ke ho
Hello relay output kam nahi kardiya
Sir, really ko timing set kese karte hai
Sorry no function available for timing based on off for relay..But agar koi speed par jane par apko relay ko operate karwana he to vo function available he vfd me..
Thanks for reply sir, vfd me timer ke similarly koi factions hai to bat sir, please
Start on delay time and stopping delay time..Ki company ki vfd me ap ye time set kar sakte ho..
Thanks for reply sir,Konsi vfd hai, sir jisme on/off delay tumer function hai , please
Ye konsi drive hain
Company name
INVT
सर
INVT VFD POFF Error दिखा रही है
मोटार solar 5.5 KW Pump जोडा है
please sugg es t
Input voltage is too low or vfd hardware problem