Ansys CFD Room Ventilation Part 2: Age of Air

แชร์
ฝัง
  • เผยแพร่เมื่อ 18 พ.ย. 2024

ความคิดเห็น • 24

  • @anivia98
    @anivia98 ปีที่แล้ว +2

    This is such a wonderful video. Thanks to you, I learned and solved a great fact! Thank you.

    • @karanjain3492
      @karanjain3492 ปีที่แล้ว

      Update failed for the Solution component in CFX. The solver failed with a non-zero exit code of : 2,What could be the reason for this particular error

  • @israel6319
    @israel6319 9 หลายเดือนก่อน

    My solver manager takes a long time to solve. How can I speed up the process?

  • @yazeidaqqad8316
    @yazeidaqqad8316 2 ปีที่แล้ว

    hi
    how old should air be to stop being fresh ? in mins

  • @Allison-gf3cg
    @Allison-gf3cg 3 ปีที่แล้ว

    Is it possible to connect to Fluent instead of CFX?

  • @salihkaya467
    @salihkaya467 3 ปีที่แล้ว +1

    can you design and take video a thermoelectric cooler (peltier effect)

    • @SingularityEngineeringLLC
      @SingularityEngineeringLLC  3 ปีที่แล้ว +2

      Good idea. There are many ways to model TEC's in Ansys using different tools. We will try to make something on this in the future.

    • @salihkaya467
      @salihkaya467 3 ปีที่แล้ว

      @@SingularityEngineeringLLC thank you so much. best regards

  • @indrapermana5192
    @indrapermana5192 3 ปีที่แล้ว

    thank you verry much

    • @karanjain3492
      @karanjain3492 ปีที่แล้ว

      Update failed for the Solution component in CFX. The solver failed with a non-zero exit code of : 2 Did you face this error??

  • @Eastan7
    @Eastan7 2 ปีที่แล้ว

    im getting this error when i open solver manager : "Update failed for the Solution component in CFX. The solver failed with a non-zero exit code of : 2". Can someone help me.

    • @karanjain3492
      @karanjain3492 ปีที่แล้ว

      were u able to solve this issue?

  • @Studiovibes-e1m
    @Studiovibes-e1m 2 ปีที่แล้ว

    Hi iam trying to run the solver but i am getting this error "Update failed for the Solution component in CFX. The solver failed with a non-zero exit code of : 2". can u please guide me

    • @karanjain3492
      @karanjain3492 ปีที่แล้ว

      were u able to solve this issue??

  • @maintenances3462
    @maintenances3462 3 ปีที่แล้ว

    please if you make this calculation by fluent ( age of air )

  • @MultiYOSEEF
    @MultiYOSEEF 3 ปีที่แล้ว

    Hi , just i wonder if you provide private lessons about fluent specifically in ventilation in compartment , please if so drop your email

  • @ziadjr3184
    @ziadjr3184 2 ปีที่แล้ว

    what is the point from this simulation , in a real case air change per hour is obtained value you can get from a reliable source like ashrae and in some methods CFM/person or CFM/area so , we already know how much air there in the room

    • @chrisb7161
      @chrisb7161 2 ปีที่แล้ว +2

      Yes we know the theoretical air changes per hour from the design conditions but there may be local pockets of air that are stagnant and recirculating therefore this air is stale and may remain in the room much longer than other air. Perhaps there is pollutant in the room what if the pollutant is in a stagnant zone where fresh air does not easily reach it and is unable to advect it, the simulation may reveal that it takes 2 hours to fully exfiltrate the pollutant but this may not be satisfactory! Mass in = Mass out but that tells you nothing about particle residence time and age of air!

    • @ziadjr3184
      @ziadjr3184 2 ปีที่แล้ว

      is there any real case application of this senario?