Electricians Day Kitchen First Fix. Wiring In the 150mm Safe Zone. D Line Clips.

แชร์
ฝัง
  • เผยแพร่เมื่อ 26 ส.ค. 2024
  • Grab a brew and relax.
    Kitchen first fix now a wall has been removed and kitchen has been agreed.
    Island power and wiring zones.
    Find me on Instagram to Cjrelectrical
    Second channel Chris Reeve
    This video is for entertainment purposes only please do not attempt to copy or recreate this video in any way.

ความคิดเห็น • 164

  • @barrysmith3123
    @barrysmith3123 4 ปีที่แล้ว +38

    Nice video. I always drill my fixing holes with a long bit before I chase out the boxes so you know they are bang on once chopped out. Just use a nail to locate them afterwards.

    • @thorhbar1255
      @thorhbar1255 4 ปีที่แล้ว +3

      Actually sounds like a great tip that. Especially on block it's hard to get the holes in the exact right place so your way would prevent that. Good tip bro

    • @carlthomas4428
      @carlthomas4428 7 หลายเดือนก่อน

      Cracking idea 👍

  • @thenullco
    @thenullco 4 ปีที่แล้ว +3

    These videos are probably more valuable than we all think. I'd love to go back in time and see what my house was like in decades gone by. See the inner workings of it all. Maybe I'm being sad. Lockdown Thought of the Day.

  • @dalefurley
    @dalefurley 4 ปีที่แล้ว +4

    Top workmanship even for 1st fixing just as important what you don’t see is well done

  • @MrRubber23
    @MrRubber23 4 ปีที่แล้ว +4

    I come from N.Ireland where all cables are chased and protected in 20 mm PVC conduit as standard, find this clipping direct and even capping very unusual but all with in the regulations i suppose. keep up the interesting videos

    • @AvroVulcanXH607
      @AvroVulcanXH607 4 ปีที่แล้ว +2

      Ah, that's why I've never seen this method here lol (also from NI)

    • @18in80
      @18in80 4 ปีที่แล้ว +1

      I too am from N.I. Directly burying T&E in tracked walls or even covering them in plastic capping before plastering was always an English thing. Here it's common to use 20 or sometimes 25mm PVC round conduit in tracked walls, a few decades ago it was more common to see oval PVC conduit before round conduit became more common.

  • @PJB71
    @PJB71 4 ปีที่แล้ว +2

    Excellent video, Top job 👍🏼
    I have been using those fire clips for a while now for the same job. Saves a ton of time. I would have put the cable into the flexi-con, just incase, can be a real pain that stuff.

  • @marymadigan9707
    @marymadigan9707 ปีที่แล้ว

    Fabulous work and also in part one you are a hard grafter 👏🇮🇪😎

  • @brianwood5220
    @brianwood5220 4 ปีที่แล้ว +2

    Thanks for sharing Chris. Love your work ethic 👍

  • @supersparks9466
    @supersparks9466 4 ปีที่แล้ว +2

    Nice one Chris mate, wish I was working, something I thought I’d never say a few weeks ago.

  • @waynenixon729
    @waynenixon729 4 ปีที่แล้ว

    Great Video again, many thanks for taking the time to show us your useful tips and tricks. You explain everything very well and show us everything we need to know to understand. If i ever did have my house re-wired, i'd do all the laborious jobs myself saving money. Get the electrician to advice on the design and do the cabling and the consumer unit. Anyone could learn so much with you as a general laborer, i'm sure people would do that job for free just to gain the experience! You would be a great teacher!

  • @brianoceallaigh8714
    @brianoceallaigh8714 4 ปีที่แล้ว +1

    Great work Chris... Your fantastic for all the neat tricks and tips... 🎯

  • @Tomoose1985
    @Tomoose1985 4 ปีที่แล้ว

    You don't muck about mate, great days work and still the usual high standard. Top stuff!

  • @danyo1972
    @danyo1972 8 หลายเดือนก่อน

    Nice job.

  • @fireblaster9961
    @fireblaster9961 4 ปีที่แล้ว +9

    Nice sound track, thought I was watching Scott brown then

  • @smitcher
    @smitcher 4 ปีที่แล้ว +7

    I know it's in the regs but that 150mm zone across the top concerns me. Have seen many a decorator batter in a finishing nail to hold up their coving while advesive cures and wouldn't like to see them batter a nail into a bond wire let alone a live one. I know they risk that with vertical drops anyway but at least in line with sockets switches they are more careful. That horizontal bond run gives may points of potentially hitting it...

    • @jonathanstephens7804
      @jonathanstephens7804 4 ปีที่แล้ว +1

      Horizontal runs are always good in kitchens to avoid drill holes for the cupboard brackets.

    • @DodgyFPV
      @DodgyFPV 4 ปีที่แล้ว

      All good trades people know to check for below surface cables and pipes before drilling or bashing in nails into walls at any height. If they don't they really should.

    • @alsanova
      @alsanova 4 ปีที่แล้ว

      My main concern is when come to installing / hanging wall cabinets. I rather run cables through ceiling, rather than along the wall. If it me as it low ceiling I would install cabinet to the ceiling so that can be in the way.

    • @PJB71
      @PJB71 4 ปีที่แล้ว

      Horizonatal runs are sometimes difficult as you are only allowed to chase in so far, depends on the depth of the block. A spark can run cable in the zoned area. I would run as close to the ceiling as possible, to try & avoid any cabinets being installed.

  • @JBE
    @JBE 4 ปีที่แล้ว +2

    Nice video Chris with an equally nice soundtrack to go. I've sometimes gone behind the back box or just next to it, hoping that anyone coming after me would have some common sense? Also you wouldn't catch me wearing shorts at first fix! 😬 stay safe mate 😉👍.

  • @kangtheconqueror
    @kangtheconqueror 4 ปีที่แล้ว

    Nice one Chris. Always enjoy watching your vids. Early darts for you today! Well, not that early, but early for you!!

  • @GiffordsElectrical
    @GiffordsElectrical 4 ปีที่แล้ว +4

    Another top class video Chris. Really enjoyed the music during the time lapse, feeling totally chilled out right now 👍

  • @zedman442
    @zedman442 4 ปีที่แล้ว +5

    Lovely job mate is it just me but I always take a picture for my records of all chases and runs before it gets all fit and dabbed. Has saved me a few times going to some old works. Also with those d clips is it ok to use plastic plugs or better with concrete screws. Cheers.

    • @JK-qm8ps
      @JK-qm8ps 4 ปีที่แล้ว

      Pictures are only way to go if you don't have drawings

  • @ovepot
    @ovepot 4 ปีที่แล้ว +12

    Would it not be better to use heavy gauge conduit in the floor? I’ve had flexible crushed in floors before

  • @chshahid8558
    @chshahid8558 4 ปีที่แล้ว +1

    Good video as always keep up n good luck

  • @gavindebrito7117
    @gavindebrito7117 4 ปีที่แล้ว

    Class video as always Chris! Nice use of D clips.👌

  • @hogdigerdy
    @hogdigerdy 4 ปีที่แล้ว +1

    haha had to watch vid twice, thought i was on hold to the bank and went to sleep, good vid's library musac

  • @rowanNClangley
    @rowanNClangley 4 ปีที่แล้ว +1

    Oh, those frustrating final milimetres to get the back box to sit properly in the hole. Takes as long sometimes as making the overall hole in the first place.

  • @ashmanelectricalservices4318
    @ashmanelectricalservices4318 4 ปีที่แล้ว +1

    Love it, stay safe Chris 👍

  • @alsanova
    @alsanova 4 ปีที่แล้ว +2

    My main concern is when come to installing / hanging wall cabinets. I rather run cables through ceiling, rather than along the wall. If it me as it low ceiling I would install cabinet to the ceiling so that can be in the way.

  • @JK-qm8ps
    @JK-qm8ps 4 ปีที่แล้ว

    Nice work Chris

  • @Danny-do2ov
    @Danny-do2ov 4 ปีที่แล้ว +1

    Great upload as always bud.

  • @djb774
    @djb774 4 ปีที่แล้ว

    Nice one Chris

  • @cumberland1234
    @cumberland1234 4 ปีที่แล้ว +1

    Just a few things - I'm an industrial spark so pls don't flame me too much!!
    Please wear eye protection when drilling/chiseling - I see you have ear protection but you also only get one pair of eyes too. If you are creating a lot of dust or any dangerous dust then please also use a dust mask.
    Where wires are being fitted in a wall and being plastered over in a wall imo fire clips are over the top - if they weren't installed and there was a fire which was that bad that the cables were to hang down I don't think a firefighter would be in there anyway.
    Personally I'd prefer an armoured cable or a steel conduit in the floor as opposed to Kopex.

    • @Cjrelectrical
      @Cjrelectrical  4 ปีที่แล้ว +3

      Agree on the spectacles and mask.
      Your missing my point on using the fire clips it’s not to protect against premature collapse but to simply hold the cables in place for me. Knock on clips pullout where as these are screwed in and never come out. Also any cables in the fabric of the building do not need protecting from premature collapse. If a ceiling is down with half the walls a few cables is the least of a firefighters worries.

  • @ahmedelectricianofiraq5550
    @ahmedelectricianofiraq5550 4 ปีที่แล้ว +1

    Great video , keep up

  • @bertiebassett1972
    @bertiebassett1972 4 ปีที่แล้ว

    Hey Chris I’m using those d line clips a lot recently but I’ve got a concrete gun which speeds things up a lot 😉😊

  • @colin9418
    @colin9418 4 ปีที่แล้ว +3

    Good content, good production value and is that a five foot level?

  • @paulclover5962
    @paulclover5962 4 ปีที่แล้ว

    Good work as always bud

  • @heriothandyman3148
    @heriothandyman3148 4 ปีที่แล้ว

    Totally with you on the doubles. Hate hate hate them. Unless you have a perfect fit, always a gap.. some try and caulk them and/or painted and looks like a dog dinner.

  • @tomorichard
    @tomorichard 4 ปีที่แล้ว +1

    If your hoping to use the water bond to bond heating pipes you are better running it to the pipe manifold at the boiler I would imagine with the amount of push fit fitting in use you may well loose the connection before it reaches the heating pipes

    • @Cjrelectrical
      @Cjrelectrical  4 ปีที่แล้ว +1

      Correct hence why I’ve run two bonds one to the water and one to the heating/boiler/oil

    • @tomorichard
      @tomorichard 4 ปีที่แล้ว

      CJR ELECTRICAL 👍

  • @MMG_MoonManGuitar
    @MMG_MoonManGuitar 4 ปีที่แล้ว +1

    Loving the use of the safe zones. 👍🏾

    • @acelectricalsecurity
      @acelectricalsecurity 4 ปีที่แล้ว +5

      Just ashame all the other following trades don't have a clue where cables are allowed to be installed, and when they hit one that's in the zone, all you get is that's a stupid place to put a cable. Who thought of that.

  • @jonathanstephens7804
    @jonathanstephens7804 4 ปีที่แล้ว

    Never used the flexi in floors I've used 20mm heavy gauge conduit to female adaptor from socket in KO box. Suppose once concretes over it will be ok. Used to be told to use SWA but gave up with that one as there's bugger all space in most of them islands for a point!
    Good vid :)

  • @r13gbs
    @r13gbs 4 ปีที่แล้ว +3

    Music you could club seals to 😀

    • @Richardincancale
      @Richardincancale 4 ปีที่แล้ว +1

      Rick B Fan of Sean Lock by any chance?!

  • @ashleighsanders
    @ashleighsanders 4 ปีที่แล้ว

    Boss job laser makes it easier than that huge level though and gets perfection within mm.

  • @jasonmart1081
    @jasonmart1081 4 ปีที่แล้ว +5

    Why are you using metal cable clips in the wall? And by bunching the cables in the one clip they don't look that deep below the surface of the plaster?

    • @JustLikeBuildingThings
      @JustLikeBuildingThings 4 ปีที่แล้ว +3

      Why does it matter if in zones? If you're drilling there... 2mm or 10mm won't make any difference!

    • @taska2510
      @taska2510 4 ปีที่แล้ว +1

      Listen to the video and he said he couldn’t get normal clips into wall so this is better/faster way to clip a bunch of cables

    • @JK-qm8ps
      @JK-qm8ps 4 ปีที่แล้ว

      @@taska2510 Exactly

  • @dsbelectricaldavidbetterid8448
    @dsbelectricaldavidbetterid8448 4 ปีที่แล้ว

    (in kitchen)run your bond to the pipe work but dont connect it till you conduct a 23k test to make sure its extraneous, some times bonding non extraneous is more dangerous if it has no ref to true earth , subject pipe work to fault currents well done enjoy the vids especially in lockdown where my own business is non going atm (also do you use wall plugs when you fit fire support clips looking inot the bre fire tests def. a worthy read in wiring matters you see my debate )

  • @Broonie719
    @Broonie719 4 ปีที่แล้ว +1

    Good video 😁

  • @Mike_5
    @Mike_5 4 ปีที่แล้ว +2

    Someone should let the homeowner know that their kitchen has been nicked

  • @MrSJT
    @MrSJT 4 ปีที่แล้ว +3

    I thought you would have put the cable inside the kopex before putting it in the floor coz it's gonna be difficult to get cable in that skinny thing no?

    • @Cjrelectrical
      @Cjrelectrical  4 ปีที่แล้ว

      No as long as it’s pulled straight and tight you can easily feed a twin and earth through it.

    • @MrSJT
      @MrSJT 4 ปีที่แล้ว

      @@Cjrelectrical ah ok, just that I saw that there seems to be a tightish corner bend on the right then up onto the wall, I guess if you're gonna pull the straight bit first before they bury the bends then you should be alright

    • @jonathanstephens7804
      @jonathanstephens7804 4 ปีที่แล้ว

      2x 2.5's?

    • @DarrenRBrown
      @DarrenRBrown 4 ปีที่แล้ว

      @@jonathanstephens7804 might struggle with 2 x 2.5s AND the 10mm earth in 20mm flexi... Agreed!

  • @bwlelectrical
    @bwlelectrical 4 ปีที่แล้ว +1

    Love the content mate!

  • @waynenixon729
    @waynenixon729 4 ปีที่แล้ว

    Could you comment on when you would or would not CAP the cable runs please. What capping would you use if you needed to use it when doing first fix? Like to protect from nicks from plasterers trowel ect.

  • @mockdeano
    @mockdeano 4 ปีที่แล้ว +5

    Guessing the customer didn't want a grid switch then 😂, personally don't like the look of loads of fused spurs on worktops.

    • @andy0175
      @andy0175 4 ปีที่แล้ว

      Nor me, rather put them in a cupboard or on a grid as you say

    • @Aliefizz
      @Aliefizz 4 ปีที่แล้ว +3

      I run a separate radial to a grid switch and keep the appliances separate from the ring circuit in kitchens. Been doing this for years hate fused spurs in a nice kitchen. PS I hate ring circuits.

    • @jamescornes1648
      @jamescornes1648 4 ปีที่แล้ว

      amf elec 4mm radial?

  • @DABroke
    @DABroke 4 ปีที่แล้ว

    I have always been told that it was bad practice to bond straight over PVC cables as the effective current rating of the cable is reduced due to the heating effect because of the lack of airspace around the cables - particularly on a kitchen ring main where loading is likely to be high.

    • @PJB71
      @PJB71 4 ปีที่แล้ว

      David, you can bond straight over cables, best to keep them flat if you can, I’ve seen lots of installs where they have been grouped together in galv band & bonded over, that could possibly be a problem

    • @stuartrhoades4306
      @stuartrhoades4306 4 ปีที่แล้ว +2

      Cables actually dissipate their heat better buried directly in the wall than if they were in conduit or under capping as the air acts as an insulator.

  • @barrybritcher
    @barrybritcher 4 ปีที่แล้ว +10

    Microwave under / over the boiler? Weird.

    • @zedman442
      @zedman442 4 ปีที่แล้ว +1

      Thought the same strange. Where is the glue high or to the side I guess.

    • @TheMingilator
      @TheMingilator 4 ปีที่แล้ว

      ive done the same with mine, mounted a high 600mm wide cabinet to encompase the boiler then mounted a built in microwave underneat/inside the cabinet

  • @paultipton743
    @paultipton743 4 ปีที่แล้ว

    With doing a lot of box cutting into block have you thought about using a box cutter/sinker kit for the socket/switch from Armeg or other manufacturers,I have Thorsman Quadra cut myself had it for awhile.

  • @garvielloken3929
    @garvielloken3929 2 ปีที่แล้ว

    nooice

  • @v0nreagan
    @v0nreagan 4 ปีที่แล้ว +1

    And why are we using D-line clips @ 53p a pop in chases? Premature collapse behind the furniture under the plaster? :D

    • @Cjrelectrical
      @Cjrelectrical  4 ปีที่แล้ว +2

      Simply better than knock on clips

  • @Kottesque
    @Kottesque 2 ปีที่แล้ว

    Great vid...but I was curious what you used for the bonding of the chased routes?

  • @chazM6116
    @chazM6116 3 ปีที่แล้ว

    Surprised you not got a square box dril cutter

  • @tomorichard
    @tomorichard 4 ปีที่แล้ว +2

    New regs??

  • @donnierobertson3088
    @donnierobertson3088 4 ปีที่แล้ว

    Nice

  • @stevengarnham8448
    @stevengarnham8448 4 ปีที่แล้ว +2

    Hi Chris, can you tell me what that sds chisel bit is, for chasing the boxes out!

    • @Cjrelectrical
      @Cjrelectrical  4 ปีที่แล้ว +1

      Hi mines a dewalt but gives you an idea.
      www.toolstation.com/heller-sds-plus-mortar-chisel/p39281?store=AB&gclid=EAIaIQobChMIzbPclPP-6AIVh-N3Ch0A7AFpEAQYBCABEgLdMfD_BwE

  • @LoftechUK
    @LoftechUK 4 ปีที่แล้ว +1

    I’m so so lost. Why a nuke box above a boiler in a cupboard with a door. 🤪🤪🤪😜

  • @farmerdave7965
    @farmerdave7965 4 ปีที่แล้ว

    It's interesting to see how buildings in U.K. are constructed. Cutting trenches to run wiring looks like a lot of work.
    How is the wiring protected from nails and screws ?

    • @darylsavage119
      @darylsavage119 3 ปีที่แล้ว

      This is in England, here in northern ireland (same bloody regs) wed be shot if we just put clips on the the cables in the wall like that, weve to chase deeper and fit the cables within 20 or 25mm pipe

  • @user-te1le7ck6b
    @user-te1le7ck6b 4 ปีที่แล้ว +2

    Still Chris every video I ask , can I please know the details of the music used during your time lapse 😩

    • @Cjrelectrical
      @Cjrelectrical  4 ปีที่แล้ว +4

      Sorry here’s a link for you 👍
      th-cam.com/video/04yvWXw5Szk/w-d-xo.html

  • @SeaCatch3
    @SeaCatch3 3 ปีที่แล้ว +1

    Hi Chris, another cracking video. Little bit confused, did you say you were going to cap the cables prior to covering with thistle bonding or did you say you were just going to clip as the thistle bonding doesn't react with the PVC?. Keep up the good work mate 👍

  • @michaelcollette8170
    @michaelcollette8170 4 ปีที่แล้ว

    What are the apprentice programs in the UK like? I'm a second year electricians apprentice in the US and we do four years on the job and four years in school. So after four years of working and going to school at nights three times a week I'm eligible to take my journeymans license test.

  • @tinytonymaloney7832
    @tinytonymaloney7832 4 ปีที่แล้ว

    Did you use 25mm boxes or 35mm? Always used 35mm in my day, bit more chasing but more waiting room.
    I like your SDS flat chisel, seen them in Screwfix but never got round to buying one. Not sure if they were even available in the 80s an 90s.
    I would have done island connection differently, I would have fitted a 30A switch on wall and taken out a 4 or 6mm radial to island as a radial.
    Not a critism BTW, we all do things differently.

  • @pyrrhical3423
    @pyrrhical3423 4 ปีที่แล้ว +1

    What do you use to fill your chases mate?

  • @arslanelectration6306
    @arslanelectration6306 4 ปีที่แล้ว

    Good

  • @nathanmemmory4981
    @nathanmemmory4981 4 ปีที่แล้ว

    nice video chris whats the sds chisel bit you are using

  • @leebrown3895
    @leebrown3895 4 ปีที่แล้ว

    hi Chris, why the extra box under the fuse boxes? Is this just easier to work with? Would a internal gland cover any reg problems with this.?

  • @dsslimone
    @dsslimone 4 ปีที่แล้ว

    What model of drill do you use to chase the sockets / walls. Nice work and videos btw.

  • @stepbackandthink
    @stepbackandthink 4 ปีที่แล้ว +1

    8:27 I don't get the 150 safe zone in the corner of the rooms. That's exactly where I'm going to drill the wall unit bracket. Can anyone explain?

    • @daveenglish2031
      @daveenglish2031 4 ปีที่แล้ว +1

      There's nothing stopping you drilling in that area but you will need to check for cables as it's considered a zone for us sparked. it's not often people will drill in the corner of a room or hand a picture within 150mm of the corner.

  • @HeathenGeek
    @HeathenGeek 4 ปีที่แล้ว +1

    1:55 is that from the Electricians Guide to the Building Regs?

    • @jameslennox4237
      @jameslennox4237 4 ปีที่แล้ว +1

      tall, dork and hungsome I thought this, thought was 300mm from the bowl of the sink meaning if you wanted to could have over drainer

  • @frazer26
    @frazer26 4 ปีที่แล้ว +1

    Is the zone for other electricians or all trades? Would a plumber or a painter know about zones so they don’t drill trough it or put a nail in it hanging up a mirror?

    • @HeathenGeek
      @HeathenGeek 4 ปีที่แล้ว

      in theory, yes

    • @Cjrelectrical
      @Cjrelectrical  4 ปีที่แล้ว +2

      Yes if they all read the building regulations

  • @jslekky3210
    @jslekky3210 4 ปีที่แล้ว

    Hi chris,
    How would you go about wiring to a fuseboard that is under the stairs but on the exterior wall? I know people going down the cavity but thats not a safe zone!

  • @shifty277
    @shifty277 4 ปีที่แล้ว

    You doing the plumbing as well Chris?

  • @stevenhastings1942
    @stevenhastings1942 4 ปีที่แล้ว

    Good video.....but ...... why don't you use egatube or capping over your cables? I know it isn't required as such but I see you go over and above in other areas such as in a loft clipping your cables precisely etc. Just a question

    • @Cjrelectrical
      @Cjrelectrical  4 ปีที่แล้ว +1

      Lots of cables with multiple cross overs. If i was leaving it for the plasterer to make good then I’d have capped it not knowing him.

  • @scconnnectltdtelecoms4997
    @scconnnectltdtelecoms4997 4 ปีที่แล้ว

    Top man

  • @samdocherty6719
    @samdocherty6719 4 ปีที่แล้ว +1

    Where can I find that a link to download the new regs for the distance from the edge of the hob now really handy to know it’s only 100mm now as I always worked to 300mm. Cheers mate. Videos are 👌🏻

    • @GeoB24
      @GeoB24 4 ปีที่แล้ว

      Sam Docherty electricans guise to building regs book on amazon

    • @PJB71
      @PJB71 4 ปีที่แล้ว

      Just remember it’s an electricians guide, it isn’t regulation.

    • @megazeus7972
      @megazeus7972 4 ปีที่แล้ว +1

      @@PJB71 seeing as there isn't a reg for distance from hob, elechickens guide is better than nothing eh

  • @stuartrawlings332
    @stuartrawlings332 2 ปีที่แล้ว

    hey mate nice video, wife and I thinking about getting our kitchen done next year.. had an electrician mate of mine probably going to do the work.. if it dont cost me too much beer! LOL! one thing I noticed you said which was different to he, either side of the hob, you said the new regs are 100mm, he said 300mm?? not too much in it I know, but might make the difference about fitting an extra socket further along the run, a quick reply would be well appreciated, stay safe, stu

    • @Cjrelectrical
      @Cjrelectrical  2 ปีที่แล้ว +1

      Check the new onsite guide.

    • @Cjrelectrical
      @Cjrelectrical  2 ปีที่แล้ว

      th-cam.com/video/rw1R-Ua-g_c/w-d-xo.html
      There you go might be helpful

    • @stuartrawlings332
      @stuartrawlings332 2 ปีที่แล้ว

      @@Cjrelectrical hey mate, thanks for that, I found the 100mm on the NHBC 8.1/22 Jan 2016 the other 300mm was on a pro-certs website informaion but looking at this is being recommended!! I'm just trying to get as many sockets etc in the right places as I can.. properly! Guess there is just a lot of conflicting info out there!

  • @chrisrix7645
    @chrisrix7645 4 ปีที่แล้ว +2

    Have you never had a plasterer cut off your cables when you leave them sticking out like that?
    I always trim them and coil them in the boxes, dont give the thistle brains the chance, who knows they may even clean out your boxes if you do

  • @samuelhollingdale8498
    @samuelhollingdale8498 4 ปีที่แล้ว

    After the first fix, I’d be interested to know if those that are still to be dotted and dabbed, are measured so you know where are, or it makes impression on plasterboard ?

    • @andy0175
      @andy0175 4 ปีที่แล้ว

      They're flush with the original board so will need cutting out by the tacker. But then they should be anyway

  • @BlueprintCNC
    @BlueprintCNC 4 ปีที่แล้ว

    Chris could you put a link to what sds drill and chisel bit you use ? , cheers!

  • @davidbrady6987
    @davidbrady6987 4 ปีที่แล้ว

    Hey Chris, do you put the cables in wavan before bonding? Love the videos. Not a tradesman. David🇮🇪🇮🇪

    • @davidbrady6987
      @davidbrady6987 4 ปีที่แล้ว

      @R-77 Oval wavan to protect the cables.

  • @calumthomson2108
    @calumthomson2108 4 ปีที่แล้ว +1

    Noticing the single boxes with the 4 screw points, I can’t help but wonder why more and more fixings are appearing with the mounting screws on the top and bottom of the faceplates. 🤔

    • @impactvision
      @impactvision 4 ปีที่แล้ว

      single K/O boxes have always had 4 lugs.

    • @obd6HsN
      @obd6HsN 4 ปีที่แล้ว +2

      They did, in the old days! I bet there are some examples in JW's museum, somewhere...

    • @jonathanstephens7804
      @jonathanstephens7804 4 ปีที่แล้ว +1

      single ko's still have 4 lugs always good practice to bend the 2 over

    • @PJB71
      @PJB71 4 ปีที่แล้ว

      The top lugs are for grid switches

  • @DamianMachola
    @DamianMachola 4 ปีที่แล้ว

    Why not put the spurs in a cupboard?

  • @wingding62
    @wingding62 4 ปีที่แล้ว

    I don't know how to determine prescribed cable zones in concrete floors. So I use armoured cables, am I wasting my time

    • @Cjrelectrical
      @Cjrelectrical  4 ปีที่แล้ว

      Common sense will prevail
      The likely hood of someone wanting to screw through an oak floor highly unlikely.

  • @markjohnadams1293
    @markjohnadams1293 4 ปีที่แล้ว

    Where did you find the kitchen layout diagram, I cant find it in the blue on-site guide.

    • @Cjrelectrical
      @Cjrelectrical  4 ปีที่แล้ว

      18th edition electricians guide to the building regulations.

    • @markjohnadams1293
      @markjohnadams1293 4 ปีที่แล้ว

      @@Cjrelectrical thank you

  • @johnlaird2734
    @johnlaird2734 4 ปีที่แล้ว

    how would you price this up,per point ???,,as they can be lots of revisits,and amendments,like your cables being moved for door frames etc.keep up the good work

    • @andy0175
      @andy0175 4 ปีที่แล้ว

      If the door was added after pricing then moving and resighting the box is an extra

  • @SpNick3
    @SpNick3 4 ปีที่แล้ว

    Is it good practice to add the washer dryer socket to the kitchen ring?? let’s say the dryer and washing machine are on at the same time pulling about 5kw and the kettle is switched on, wouldn’t the be overloading? Like now people have all types of stuff e.g. bread makers, toasty grills, blenders, etc what’s if they on these appliances at the same time. What is your suggestion for this situation? Great work btw I learn loads from your vids. also what sds bit is that?

    • @thenullco
      @thenullco 4 ปีที่แล้ว +1

      Happened to my Mrs literally a few weeks ago. Washing machine going full pelt whilst the dishwasher, kettle and food blender were running. Very rare occurrence, but it tripped. I'd love a separate ring for white goods appliances.

    • @taska2510
      @taska2510 4 ปีที่แล้ว +2

      The chances of each of the appliances being on at the same time and pulling there maximum load is minimal. I get where you are coming from though.

    • @reecemayho3648
      @reecemayho3648 4 ปีที่แล้ว +1

      yes but think about your main fuse! 80/100amp. and your house has multiple circuits which all add to far greater than 80amp. its just diversity that not everything will be on at one time same time juts have to think about what is running.

  • @TheMingilator
    @TheMingilator 4 ปีที่แล้ว

    must be one hell of a cooker to need to use 10mm cable, I'm not seeing any gas pipes is it all electric?

    • @Cjrelectrical
      @Cjrelectrical  4 ปีที่แล้ว

      Correct

    • @TheMingilator
      @TheMingilator 4 ปีที่แล้ว

      @@Cjrelectrical 50 amp breaker?

    • @Cjrelectrical
      @Cjrelectrical  4 ปีที่แล้ว

      40 not had a call to it tripping yet

    • @TheMingilator
      @TheMingilator 4 ปีที่แล้ว

      @@Cjrelectrical would 6mm not have been adequate for that or is it just insurance against a potential upgrade of the appliance?

    • @Cjrelectrical
      @Cjrelectrical  4 ปีที่แล้ว +2

      Mark Inglis always go with manufacturers recommendation

  • @k20aa
    @k20aa 4 ปีที่แล้ว

    Fuc? me a sparky who fills his own holes in and cleans up after him self . Fair play very nice job

  • @martinw245
    @martinw245 3 ปีที่แล้ว

    I've never seen the logic of the 150 safe zone. People nail coving in that area. It's not safe at all in my view

  • @darrenburns123
    @darrenburns123 2 ปีที่แล้ว

    The music remind anyone of willy wonka and the chocolate factory, the original one?

  • @SignedAdam
    @SignedAdam 4 ปีที่แล้ว

    Can’t you claim off the government? we are all meant to be at home?

  • @Im_robbo
    @Im_robbo 4 ปีที่แล้ว

    What drill is it you are using for knocking out the boxes?

  • @ghspaelectricalservices9296
    @ghspaelectricalservices9296 4 ปีที่แล้ว

    Nice one Chris