Two way slab Reinforcement detailing | Area of steel calculation for two way slab | Part-2

แชร์
ฝัง
  • เผยแพร่เมื่อ 21 ส.ค. 2024
  • Hi All!!!
    This video explains about two way slab design and detailing with step by step procedure and how to calculate the area of steel by using code SP-16.
    Keep watching!!!Happy learning!!!
    Please refer the below link for more slab related videos
    1.Two way slab Design - part-1
    • Two way Slab Design | ...
    2.Difference between one way slab & two way slab
    www.youtube.co....
    3.Sunken slab
    www.youtube.co....

ความคิดเห็น • 33

  • @sabarishbabu3902
    @sabarishbabu3902 4 ปีที่แล้ว +1

    Thankyou for civil engineering related videos.

  • @CivilThinking
    @CivilThinking 4 ปีที่แล้ว +1

    Your Engineering Lectures are amazing , big fan mam.

  • @aamirsheikh8306
    @aamirsheikh8306 4 ปีที่แล้ว

    You are an amazing teacher ...you lectures are very useful .. God bless you mam.. thank-you

  • @abc-e.c
    @abc-e.c 3 ปีที่แล้ว

    Very good design calculation and detailing
    Very nice and important video
    Thanks man
    What is the maximum deflection for one way and two way slab

  • @KishoreKumar-nr3vv
    @KishoreKumar-nr3vv 4 ปีที่แล้ว +1

    Super awesome Mam,
    REALLY APPRECIATE

  • @CivilThinking
    @CivilThinking 4 ปีที่แล้ว +1

    First viewer mam

  • @vaseemahamed8447
    @vaseemahamed8447 4 ปีที่แล้ว

    How can find the longer span of length of crank ? Mam.. please explain mam

  • @_NigmalRajas
    @_NigmalRajas 4 ปีที่แล้ว

    Nice Mam , next video please upload four adjacent side continuous conditions method

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  4 ปีที่แล้ว

      Four adjacent edges continuous slabs are considered as interior panels.
      Please check IS-456 Table-26 for co-efficient values and follow the same procedure which is shown in the video.

    • @_NigmalRajas
      @_NigmalRajas 4 ปีที่แล้ว

      @@CivilEngineeringMastery ok Thanks Mam... Lot of channels are available in TH-cam, but your channel is very nice and good responsibility for viewers from your side keep itup mam

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  4 ปีที่แล้ว +1

      Thanks for your kind words.Please share it with your friends.

  • @narasimhamurthy2800
    @narasimhamurthy2800 4 ปีที่แล้ว

    Mam why we have to take L/7 at one side and L/3 at another side what is the reason please explain it mam

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  4 ปีที่แล้ว

      L/3 & L/7 are the length of extra bars provided as per code.L is the shorter span of the slab.

  • @sonukumar-bp4wb
    @sonukumar-bp4wb 4 ปีที่แล้ว

    Can I give you a PDF for Culvert Design? You can make videos on it.

  • @kazimhaider7216
    @kazimhaider7216 4 ปีที่แล้ว

    What is SP -16 ? Where i get this ? ..............Thanx

  • @sonukumar-bp4wb
    @sonukumar-bp4wb 4 ปีที่แล้ว

    How to provide diameter of Steel 8 mm

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  4 ปีที่แล้ว

      That is the minimum diameter of bar we have to use for slab.

    • @sonukumar-bp4wb
      @sonukumar-bp4wb 4 ปีที่แล้ว

      @@CivilEngineeringMastery Even then there must be some condition to provide steel. What Ast required for total area for slab .

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  4 ปีที่แล้ว

      There is no condition to provide area of steel but there are conditions to provide % of steel. For Fe250- 0.12% & For Fe-415-0.15%.
      Please refer IS-456 code.

    • @sonukumar-bp4wb
      @sonukumar-bp4wb 4 ปีที่แล้ว

      If we can use 12 mm or 16 mm instead of 8 mm, if we build multi story building then

    • @sonukumar-bp4wb
      @sonukumar-bp4wb 4 ปีที่แล้ว +1

      @@CivilEngineeringMastery please make a design on a hole building structure