Cemfloor Liquid Screed Demo with McGrath's Cong

แชร์
ฝัง
  • เผยแพร่เมื่อ 2 ก.ค. 2019
  • www.thatsfarming.com/
    www.tfmedia.ie/
  • บันเทิง

ความคิดเห็น • 20

  • @lifeshort
    @lifeshort 7 หลายเดือนก่อน

    Lovely job Paddy 👍🏼

  • @adamroden7206
    @adamroden7206 ปีที่แล้ว

    Great video

  • @AF-ew9zd
    @AF-ew9zd 3 หลายเดือนก่อน +1

    Is it possible that after pouring when the screed settles it pushes the insulation and damp proof membrane down to the subfloor and it makes a 40mm difference? Our builder is telling us this. We need to do another round of pouring to compensate for the 40mm.

  • @handle1196
    @handle1196 3 ปีที่แล้ว +2

    Just a couple of questions as im looking to do this next year.
    1. Where do you get the target and metal pipe to do the test before the pour?
    2.What was the thing with 3 threaded bars testing the hardened floor?

  • @ryanduffy4847
    @ryanduffy4847 2 ปีที่แล้ว

    Top job👍

    • @pauloshea3741
      @pauloshea3741 2 ปีที่แล้ว

      Fuck, you're standards are low, thats the worst laid pipework I've ever seen!

  • @Bars11805
    @Bars11805 3 ปีที่แล้ว

    Is aggregate an option to help build up and reinforce??

  • @MrJohnbtg
    @MrJohnbtg 2 ปีที่แล้ว

    What kind of pump is that being used?

  • @SN-hx4mg
    @SN-hx4mg 4 หลายเดือนก่อน

    Where are you based, and how much cost per square meter?

  • @brian559
    @brian559 4 ปีที่แล้ว

    I refer to you setting the level at the front door...I take it the measurement from the bottom of the door to the plastic sheet was 75mm?...you then allowed 25 mm for clearance of floor coverings etc, which then means 50 mm of actual liquid screed?.....but I have found that on my new build where I haven't put the insulation down yet, there is a difference in height from the concrete sub floor to bottom of the front door (23 cm)...and the back door (25 cm)....given your video scenario would this mean I would place the same thickness insulation over the whole sub floor, and when the liquid screed is poured, it will be 50 mm thick at the front door, and 70mm thick at the back door....is that the way it works?....your feedback would be appreciated

    • @DavidSmith-do6ji
      @DavidSmith-do6ji 4 ปีที่แล้ว

      Hi Brian, my first thoughts would be that you quite possibly have a low threshold disabled access front door and a normal threshold backdoor. The screed will need to have the 25mm clearance at the front door as this is the lower door of the two, the screed will then be laid level from there at 50mm in thickness leaving a 45mm clearance at the backdoor, although a lot of back doors open outwards. Other than that the brickwork/concrete floor could be out of level, I hope this helps. David

    • @paulgorman8097
      @paulgorman8097 3 ปีที่แล้ว

      Your answer doesn’t make sense. Brian said there is a discrepancy in his sub floor level which you haven’t accounted for in you answer?

  • @aarontodd100
    @aarontodd100 2 ปีที่แล้ว +1

    Hi a question if i may, i see that around the perimeter edging there is insulation boards however does the screed not oxidise with the aluminum coating ? I know from past experience that this causes a bubbling effect within the screed but i'm not sure if that changes product to product. Many Thanks

  • @user-mv2zy8gk2h
    @user-mv2zy8gk2h 3 ปีที่แล้ว

    Чем вы сверху распыляете или пшыкаете?)

  • @paulgorman8097
    @paulgorman8097 3 ปีที่แล้ว +1

    How much does it cost per square meter laid all in?

    • @SirMrShanks
      @SirMrShanks 10 หลายเดือนก่อน

      About £285 per cubic meter excluding the price to get it laid. A lorry with carry 7.5 meters a time

  • @MR54TSN
    @MR54TSN ปีที่แล้ว

    Could have spaced the UFH pipes with more care :D

  • @pauloshea3741
    @pauloshea3741 2 ปีที่แล้ว +1

    That's the shittest underfloor heating layout that I've ever seen! Disgracefull