SOK SK48v100: Voltronic (MPP/EG4/SunGold) Communications Setup

แชร์
ฝัง
  • เผยแพร่เมื่อ 23 ธ.ค. 2024
  • In this video, we explain how to setup communications with the Voltronic Inverters such as MPP Solar, EG4 and SunGoldPower.
    USB-RS232 Adapter: www.currentcon...
    Inverter Communication Cables: www.currentcon...
    RJ45 Patch Cables for Linking Batteries: www.currentcon...
    ✅ Our Top Pick LiFePO4 Batteries by Voltage & Capacity: 🔋
    1️⃣2️⃣V Batteries: 🔋
    ▪️ Epoch Essentials 105Ah Battery - www.currentcon...
    ▪️ Epoch Essentials 300Ah Battery - www.currentcon...
    ▪️ Epoch Essentials 460Ah Battery - www.currentcon...
    ▪️ Epoch Pro 460 Ah Battery - www.currentcon...
    ▪️ EG4-LL 400Ah Server Rack Battery - www.currentcon...
    2️⃣4️⃣V Batteries: 🔋
    ▪️ EG4-LL 200Ah Server Rack Battery - www.currentcon...
    ▪️ EG4 LifePower4 200Ah Server Rack Battery - www.currentcon...
    4️⃣8️⃣V Batteries: 🔋
    ▪️ EG4 LL-S 100Ah Server Rack Battery - www.currentcon...
    ▪️ EG4 LifePower4 100Ah Server Rack Battery - www.currentcon...
    ▪️ EG4 Indoor WallMount 280Ah Battery - www.currentcon...
    ▪️ EG4 PowerPro Outdoor WallMount 280Ah Battery - www.currentcon...
    ✅ Our Top Pick Inverter/Chargers by Voltage: ⚡
    1️⃣2️⃣V Inverters: ⚡
    ▪️ Victron 12V Quattro-II 3kVA 2x120V - www.currentcon...
    ▪️ Victron 12V MultiPlus-II 3kVA 120V - www.currentcon...
    ▪️ Victron 12V MultiPlus-II 3kVA 2x120V (UL Model) - www.currentcon...
    2️⃣4️⃣V Inverters: ⚡
    ▪️ Victron 24V MultiPlus-II 3kVA 2x120V - www.currentcon...
    ▪️ Victron 24V MultiPlus-II 3kVA 120V - www.currentcon...
    ▪️ Victron 24V Quattro-II 3kVA 2x120V - www.currentcon...
    4️⃣8️⃣V Inverters: ⚡
    ▪️ Eg4 3000 EHV-48v Inverter/Charger - www.currentcon...
    ▪️ EG4 6000XP Off-Grid All-in-One Inverter/Charger - www.currentcon...
    ▪️ MidNite Solar Rosie 7048RE 7000W Inverter 120Amp Charger - www.currentcon...
    ▪️ MidNite TheOne - 11.4kW Hybrid All-in-one Inverter - www.currentcon...
    ▪️ EG4 12kPV 48V 8kW Hybrid All-In-One Inverter - www.currentcon...
    ▪️ Sol-Ark 15kW All-In-One Hybrid Inverter - www.currentcon...
    ▪️ EG4 18kPV | 48V 12kW All-in-One Hybrid Inverter - www.currentcon...

ความคิดเห็น • 29

  • @mattnewman8103
    @mattnewman8103 2 ปีที่แล้ว +8

    Thank you for providing this level of precise detail.
    Would love to see this with a Victron MultiPlus.
    Also if you have two connected to victron MP and cerbo does the victron see the combined battery size and total current or do we need to also use a shunt?

  • @jnjentinc
    @jnjentinc 2 ปีที่แล้ว +5

    Do you plan on doing a video with Victron equipment?

  • @jackjetpilot
    @jackjetpilot ปีที่แล้ว +2

    What is the procedure for connecting the communications for multiple SOK batteries together?

  • @LithiumSolar
    @LithiumSolar 2 ปีที่แล้ว +3

    So easy when you're inverter doesn't have buggy firmware! 🙂🙂

  • @RussellHogan
    @RussellHogan ปีที่แล้ว

    Close loop communications with the SOK 48V and LVX6048WP MPP Solar do not allow me to adjust the low voltage cutoff. Close loop sets it to 44.8V. That's way too low, correct? What should I do?

  • @aliusef2912
    @aliusef2912 หลายเดือนก่อน

    thanks mate. this video was very useful

  • @jeffcalder2349
    @jeffcalder2349 2 ปีที่แล้ว

    I am running the SMA Sunny Island 6048. When you get this figured out with SMA would please post something to help us with this devise? Thanks

  • @mikloskalman2841
    @mikloskalman2841 ปีที่แล้ว

    I have a question. I have the same inverter, but with a pylontech battery, I only use the brown and brown/white cables for the communication cable, what is the green cable for? Thank you for your answer in advance! Miky

    • @RiazMemon-kk5id
      @RiazMemon-kk5id 8 หลายเดือนก่อน

      That is the ground pin which runs from pin 8 of inverter and pic 6 on battery

  • @Just_An_Idea_For_Consideration
    @Just_An_Idea_For_Consideration 2 ปีที่แล้ว

    Do you know if Voltronic also makes the mpp lvx6048wp? And if so is this info the same for that inverter?
    thx

  • @Vibe77Guy
    @Vibe77Guy 2 ปีที่แล้ว

    Would a similar procedure work to connect the Sungold 48v 5kw inverter to an EG4 48v 100wh rack mount battery?

    • @HighTechLab
      @HighTechLab 2 ปีที่แล้ว

      No clue, it's a totally different inverter and battery.

    • @Vibe77Guy
      @Vibe77Guy 2 ปีที่แล้ว

      @@HighTechLab
      Is it not still a Voltronic inverter?

    • @HighTechLab
      @HighTechLab 2 ปีที่แล้ว +1

      @@Vibe77Guy as much as Chevy is a GM

  • @MrJacquesvheerden
    @MrJacquesvheerden ปีที่แล้ว

    Hi Sir, Nice video indeed. Do you have a link to download your vs of Pbms please. My vs does not have that 1st step to select the battery protocol.

  • @Sanwizard1
    @Sanwizard1 2 ปีที่แล้ว

    Nice overview! Thanks for showing the pinout.

  • @super2222sd
    @super2222sd 2 ปีที่แล้ว

    hi can you give me the pinout for the rs232 port please, thanks

    • @CurrentConnected
      @CurrentConnected  ปีที่แล้ว

      Please source the RS232 cable from your point of sale for SK48V100 batteries.

  • @Scat.original
    @Scat.original ปีที่แล้ว

    Thank you for a great detailed video

  • @RussellHogan
    @RussellHogan ปีที่แล้ว

    Mine says paceic. It will not change when I select pylon_485. I get a write error. Any idea?

    • @therust2001
      @therust2001 ปีที่แล้ว

      Did you figure anything out having same issue

    • @RussellHogan
      @RussellHogan ปีที่แล้ว

      @@therust2001 No I did not. Let’s keep each other posted as we figure this out.

  • @brucecarter5856
    @brucecarter5856 2 ปีที่แล้ว

    Watch out, does not communicate with eg4 6500 , error 61 pops up

    • @cseaton42
      @cseaton42 ปีที่แล้ว

      Ever get communication working with EG4 6500EX?

    • @cseaton42
      @cseaton42 ปีที่แล้ว

      @currentconnected Anything to say about this? I'm about to try this with EG4-6500EX-48 and wonder if you've actually connected these batteries to that specific inverter.

    • @HuyTran-zy9sv
      @HuyTran-zy9sv 8 หลายเดือนก่อน

      @@cseaton42 Have you had any success with this? I just bought an SOK battery locally but have not have communication cable to try.
      If you got it working, which protocol to set to?

  • @PulseElectrical-uq2fk
    @PulseElectrical-uq2fk 15 วันที่ผ่านมา

    Thank you

  • @igorkvachun3572
    @igorkvachun3572 2 ปีที่แล้ว

    Yes👍🔋 ⚡💡

  • @quickquote1568
    @quickquote1568 8 หลายเดือนก่อน

    Voltronic Power, high frequency, transformerless inverters. No thanks! Low frequency, transformer based inverters are so much better that these units.