Installing Power Receptacle in our Metal Building! IT’s EASY!

แชร์
ฝัง
  • เผยแพร่เมื่อ 2 ต.ค. 2024

ความคิดเห็น • 161

  • @DJsHotRodFab
    @DJsHotRodFab ปีที่แล้ว +1

    Thank you for passing on your knowledge.

    • @barryely1
      @barryely1 ปีที่แล้ว +1

      There isn't much knowledge here. This video should he deleted. Box isn't bonded and anti short bushing wasn't used.

    • @DJsHotRodFab
      @DJsHotRodFab ปีที่แล้ว

      @@barryely1 you are correct. I used anti short bushings on my wiring and bonded all metal boxes

  • @michaeljavert4635
    @michaeljavert4635 2 ปีที่แล้ว +19

    Box is likely grounded, but better practice is to bond it to the ground. The steel armor and box are conductive, so it's grounded that way. Also the ground screw on receptacles also have continuity to the metal parts that screw the receptacle to the box, so there is a ground present even in the absence of a ground wire, in that case. But always use the ground wire and always bond it.
    Also use the top and bottom screws and a nut. The center screw can come loose, and also the pressure of plugging things in can weaken the outlet and wear it out prematurely.

    • @boltkane6827
      @boltkane6827 11 หลายเดือนก่อน +3

      That's right. It is a code violation to install a receptacle to a cover the
      way it is is done in this video. NEC 406.5(C)

  • @nathangriffin9893
    @nathangriffin9893 2 ปีที่แล้ว +9

    I work at southwire mc plant where this cable is manufactured, you do not need that tool. Break the armoring and cut it with tin snips.

  • @jasnapon
    @jasnapon ปีที่แล้ว +1

    That outlet should be grounded to the metal box as well

  • @domofishing9316
    @domofishing9316 3 ปีที่แล้ว +12

    Notice the switch has bottom screw with yellow cap which would ground, but will it need a pigtail to the metal box to ensure proper grounding?

    • @bsmith8564
      @bsmith8564 2 ปีที่แล้ว +1

      Yes on a raised cover.

  • @sammymiller5967
    @sammymiller5967 ปีที่แล้ว +2

    The man seems like a nice guy but he is doing it all wrong do not do it his way

  • @LiloUkulele
    @LiloUkulele 2 ปีที่แล้ว

    After my shop burned down I'm rebuilding with metal. Time to learn how to use shielded cable.

  • @mikeryan6277
    @mikeryan6277 2 ปีที่แล้ว +12

    Box needs to be bonded as well as grounding the devise, and MC Cable needs to be secured.

    • @cannoncolossus2449
      @cannoncolossus2449 2 ปีที่แล้ว

      Good comment. The ground should be bonded to the box and MC cable secured. The way presented in this video is potentially dangerous in the long term and will not pass inspection. Otherwise good video.

    • @tot2600hrs
      @tot2600hrs 2 ปีที่แล้ว

      Forgot the anti chaffing grommet inside MC cable.

    • @sercansakizoglu967
      @sercansakizoglu967 ปีที่แล้ว

      exactly he didn't ground the box right ?

  • @JohnThomas-lq5qp
    @JohnThomas-lq5qp 2 ปีที่แล้ว +9

    Best practice is to use the two provided 6 - 32 screws to attach receptacles to metal cover rather then only the center screw that usually comes loose. After cutting Type AC or MC cable cut the sharp edge at a 45 degree angle then install red anti short bushing.

    • @ericarona8599
      @ericarona8599 ปีที่แล้ว

      Those screws aren't "provided"? It comes with only one in the center

    • @JohnThomas-lq5qp
      @JohnThomas-lq5qp ปีที่แล้ว +1

      The 1900 duplex receptacle covers that I purchased at several electrical supply houses always had two 6/32 screws along with hex nuts that often had flimsy lock washers attached or small piece of metal for 6/32 screws to screw into. I always had a plastic hinged storage box that contained an assortment of 6/32 & 8/32 screws, flat washers, hex nuts & lock washers.

    • @ericarona8599
      @ericarona8599 ปีที่แล้ว +1

      @@JohnThomas-lq5qp The cover plates had those break off tabs that I just used and worked great

  • @NYTROeast
    @NYTROeast ปีที่แล้ว +3

    Should you be doing a jumper from the ground to the box so the box is grounded also since it is a metal box fastened to a metal building?

  • @garbo8962
    @garbo8962 ปีที่แล้ว +1

    And where are the two screws that come with the cover? Would not pass inspection in my area with just the flimsy single 6/32 screw .Hospital that I did a lot of electrical work in would only allow connectors that used locknuts. Smart using type MC cable that has a insulated copper real deal ground conductor verses the flimsy #16 or 18 guage aluminum wire that's inside type AC ( BX ) cable. You should have use a ground screw to ground the metal box. Extremely dangerous if the two 8/32 screws come loose or fall out then box is not grounded.

  • @brandonrippeonphoto
    @brandonrippeonphoto ปีที่แล้ว +1

    No red eye; no box bonding. amateurs should not be making how to videos for electrical work…

    • @TheBigDanShow
      @TheBigDanShow  ปีที่แล้ว

      Lol

    • @wisdomcalls2475
      @wisdomcalls2475 ปีที่แล้ว

      Q. Shouldn’t you be bonding the metal frame building to ground due to lightning strikes 🤔

  • @santiagodominguez2522
    @santiagodominguez2522 3 ปีที่แล้ว

    Good job!!!

  • @keithharrington8715
    @keithharrington8715 2 ปีที่แล้ว +2

    As an electrical guy, I know that videos are there to inspire. Please do not take them as a step by step instruction as the code allows each building department (Jurisdiction) to adjust (interpret) the code as written.
    Many commentors pointed out several code misses:
    210.8. Gfci for homes puts "out buildings" under garage requirements.
    547. Is for "AGRICULTURAL BUILDINGS" with wiring method restrictions based on the animals kept there.
    Anyone can put a wire under a screw, but which screw is where the money is made. You can learn and do yourself, but calling the building inspectors or a local guy that just did that same job last week might get you a solution to a problem you never knew you had.

  • @christopherdegarmo9826
    @christopherdegarmo9826 3 ปีที่แล้ว +2

    bond the box.......

  • @JohnThomas-lq5qp
    @JohnThomas-lq5qp 2 ปีที่แล้ว +1

    No such thing any more in the NEC called a neutral. AHOLES changed one of the most common electrical term that was used for over a hundred years to " Grounded Conductor " . Best to spend a little extra & purchase at least Spec grade receptacles. Will last a lot longer. Now must use a torque driver or torque wrench to tighten All ELectrical terminals. Not a plug , A plug goes on the end if a cord to plug into a receptacle.

  • @jesseexum1084
    @jesseexum1084 6 หลายเดือนก่อน

    What size fittings are these and where did you get them?

  • @nsbconstruction9698
    @nsbconstruction9698 3 ปีที่แล้ว +8

    No ground to the box?

    • @JBarnes917
      @JBarnes917 3 ปีที่แล้ว +4

      Glad I’m not the only one yelling at the screen. These residential rats shouldn’t be teaching.

    • @Faruk651
      @Faruk651 2 ปีที่แล้ว

      these are hacks

    • @jcjammer1
      @jcjammer1 2 ปีที่แล้ว +1

      I Always use metal conduit.
      No chance of getting snagged and unraveled.
      just my personal choice.😄

    • @joselovos6708
      @joselovos6708 ปีที่แล้ว

      @@JBarnes917 old stile

    • @JBarnes917
      @JBarnes917 ปีที่แล้ว

      @@joselovos6708 old? It’s illegal and it’s dangerous

  • @richarda.valdes1197
    @richarda.valdes1197 หลายเดือนก่อน +1

    I was searching the subject to see what should be done about the raised rib on the metal post

  • @soullessdevice
    @soullessdevice 2 ปีที่แล้ว

    Well yeah, everything is easy

  • @fatherappel1792
    @fatherappel1792 11 หลายเดือนก่อน +1

    I understand that the socket should be grounded to a metal outlet box. However, I've also read that you can never ground to the structure. So what should be done when using a metal box on a metal frame??

  • @hightowerelectricllc6132
    @hightowerelectricllc6132 3 ปีที่แล้ว +9

    FAILED!
    1) No anti-short bushing for your MC
    2) Receptacle is not GFCI protected, all garages need to be
    3) MC cable not properly supported
    4) Did not properly support the receptacle devise to the RS cover. That middle screw is not a means of support only the top and bottom yoke

    • @recon1314
      @recon1314 3 ปีที่แล้ว +1

      The type of connector he used has a built in "anti short" sleeve in the throat. 100% on board with a fail for everything else

    • @JimYeats
      @JimYeats 3 ปีที่แล้ว +2

      @@recon1314 That redhead at the end of the connector is just to protect the wires from the end/edges of the connector, you still need a redhead at the end of the mc cable where the wire would rub on that. Really truly.

    • @garagekeys
      @garagekeys 2 ปีที่แล้ว +1

      Anti-short bushing I thought is not required with MC that is optional

    • @JimYeats
      @JimYeats 2 ปีที่แล้ว

      @@garagekeys Maybe in certain codes and jurisdictions? Do you want your thinly coated wire rubbing on a sharp MC edge? Super easy and cheap insurance.

    • @garagekeys
      @garagekeys 2 ปีที่แล้ว

      @@JimYeats yeah, I looked in the NEC 320.40 states AC cable needs the bushings not MC it's optional it looks like if you follow NEC

  • @manuelfuentes8741
    @manuelfuentes8741 7 หลายเดือนก่อน +2

    Good job my friend

  • @sammymiller5967
    @sammymiller5967 ปีที่แล้ว +2

    You need to add a red ear on your MC cable first

    • @tomnorman5461
      @tomnorman5461 ปีที่แล้ว +1

      It's called an 'anti-short bushing' in my neck of the woods. The snap-in connector he's using has this built-in.

    • @TerryRGraham
      @TerryRGraham 11 หลายเดือนก่อน

      @@tomnorman5461 No, that built-in doesn't replace the anitishort bushing. It will fail inspection.

  • @4BFL11
    @4BFL11 21 วันที่ผ่านมา

    No wonder he didnt bond, cuz he prescibe.

  • @blacksteel2434
    @blacksteel2434 3 ปีที่แล้ว +1

    You didnot wrap your wire around the outlet screws what in the word

  • @DAVADMDAVAD
    @DAVADMDAVAD 3 หลายเดือนก่อน

    I need tu git ma Prescribe fer ma medsin.

  • @brents927
    @brents927 2 ปีที่แล้ว +2

    I don't want the camera man's comments

  • @stevestewart3816
    @stevestewart3816 2 หลายเดือนก่อน

    At 2:47 he realized he fucked up lol

  • @gguerrero5503
    @gguerrero5503 ปีที่แล้ว

    What's the name of the fasteners used at 3:09 and following?

  • @jamesbrenneman6841
    @jamesbrenneman6841 3 ปีที่แล้ว

    Thanks great video

  • @ourv9603
    @ourv9603 3 ปีที่แล้ว +1

    I bought a brand new house. The contractor was thoughtful
    enough to give me 5 outlets on each wall. The outlets are fed
    with 20Amp breakers. Each outlet is wired with yellow 20Amp
    romex. HOWEVER, each outlet is 15Amp. How that passed
    inspection is beyond me. I'm having to replace all the outlets
    with 20Amp.
    !

    • @frank480
      @frank480 3 ปีที่แล้ว +10

      NEC allows the use of 15 Amp rated outlets on 20 Amp branch circuits.

    • @wheelzup7597
      @wheelzup7597 3 ปีที่แล้ว +7

      That will definitely pass code, it’s within spec.

    • @garagekeys
      @garagekeys 2 ปีที่แล้ว +7

      I believe you are allowed to use 15 amps outlet on 20 amp circuit, just not a 20 amps plug on a 15 amp circuit can't do that

    • @donaldlee6760
      @donaldlee6760 2 ปีที่แล้ว +2

      FYI - the reason it passed inspection is because it is safe to use 15 amp outlets on a 20 amp circuit. Obviously it is dangerous to do the opposite (plug your 20 amp device on a 15 amp circuit and possibly causing a fire).

    • @KevinCoop1
      @KevinCoop1 2 ปีที่แล้ว +2

      @@TheBigDanShow You stayed metal buildings are required to have 20 amp receptacles on 20 amp circuits. Where does this rule come from?

  • @F16_viper_pilot
    @F16_viper_pilot 10 หลายเดือนก่อน

    Um, no ground to the box?? That ground wire should be attached to the box, not the outlet, and a grounding pigtail attached from the box to the outlet grounding screw.

  • @blainekeener6100
    @blainekeener6100 3 ปีที่แล้ว +6

    Counted 4 code violations

  • @donaldlee6760
    @donaldlee6760 2 ปีที่แล้ว +1

    At 1:04 - that cutting disk reminds me of a dremel cutting disk. I wonder if one has a dremel tool and they don't need to cut MC cable as part of their daily job, then one could just use their dremel?

    • @michaelking42
      @michaelking42 ปีที่แล้ว

      It would be very easy, but easy to cut the wire insulation as well.

  • @Geno-j5g
    @Geno-j5g 2 หลายเดือนก่อน

    Why didn’t you make hooks on the screws? 1st yr apprentice here I was always told to hook it this is so much easier!

  • @michaelking42
    @michaelking42 ปีที่แล้ว +2

    Mate, I'm an electrician from Australia, living in Florida now. I find it crazy how difficult you yanks make electrical work. Living here, I almost have to relearn the entire trade. Thanks for the info, and also to the commentary above and below for their input. Makes it a little easier to figure this stuff out.

    • @nicocaffarilla8556
      @nicocaffarilla8556 12 วันที่ผ่านมา

      They don’t pay you guys enough down there unless you work on the service end of things

    • @nicocaffarilla8556
      @nicocaffarilla8556 12 วันที่ผ่านมา

      Down there in Florida*, that is

  • @randybarnes6661
    @randybarnes6661 3 ปีที่แล้ว +2

    Thanks for sharing your knowledge buddy

    • @barryely1
      @barryely1 ปีที่แล้ว

      There isn't much knowledge here. This video should he deleted. Box isn't bonded and anti short bushing wasn't used.

  • @sammymiller5967
    @sammymiller5967 ปีที่แล้ว

    You first need to ground your box then your plug in

  • @terrydougherty7078
    @terrydougherty7078 2 ปีที่แล้ว

    Please don’t follow any of these “tips”. Call a professional.

  • @Kevin-wj4ed
    @Kevin-wj4ed 4 หลายเดือนก่อน

    What are the violations?

  • @garagekeys
    @garagekeys 2 ปีที่แล้ว

    Do yourself a favor.... Call a pro

  • @brandonm922
    @brandonm922 3 ปีที่แล้ว +8

    Box wasn’t grounded, receptacle wasn’t wrapped in electrical tape on the conductors and ground should go up but everything else was right to me. Great way of explaining!

    • @trustme7731
      @trustme7731 3 ปีที่แล้ว +8

      Tape isn't necessary or required. There is no requirement for the position of the ground.

    • @ABflanagan523
      @ABflanagan523 3 ปีที่แล้ว +2

      I agree that the box wasn’t making direct contact to the ground wire but the MC and metallic box is an equipment grounding conductor.

    • @JBarnes917
      @JBarnes917 2 ปีที่แล้ว +8

      @@ABflanagan523 needs a ground pig tail period… THIS WILL FAIL A REAL INSPECTION.

    • @jcjammer1
      @jcjammer1 2 ปีที่แล้ว +1

      No red bushing before connector?

    • @jimchang9394
      @jimchang9394 2 ปีที่แล้ว +3

      It's bounded,The 20 A receptacle with the gold clip is a self-bonding mechanism.

  • @sercansakizoglu967
    @sercansakizoglu967 ปีที่แล้ว

    did he ground the box as well ?

  • @theshop5331
    @theshop5331 8 หลายเดือนก่อน

    good grief

  • @Steven-eh9qs
    @Steven-eh9qs 3 ปีที่แล้ว +4

    I want more videos like this, hes seems very knowledgeable.

    • @JBarnes917
      @JBarnes917 3 ปีที่แล้ว +3

      To bad he missed the box being bonded with the ground. This is an NEC code issue.

    • @CHEECHMUN
      @CHEECHMUN 3 ปีที่แล้ว +1

      @@JBarnes917 So is an extra wire from the green screw, needed to go directly to metal box?

    • @JBarnes917
      @JBarnes917 3 ปีที่แล้ว +2

      @@CHEECHMUN exactly, there is a spot in the back of the box that a ground screw is made to go in. You can get pre made pigtails that have the screw and a short green wire on it.

    • @CHEECHMUN
      @CHEECHMUN 3 ปีที่แล้ว

      @@JBarnes917 Thank you!!!

    • @barryely1
      @barryely1 ปีที่แล้ว +2

      There isn't much knowledge here. This video should he deleted. Box isn't bonded and anti short bushing wasn't used.

  • @jimcole6423
    @jimcole6423 3 ปีที่แล้ว +3

    You can use any jacketed conductors in a metal building that will be enclosed.

  • @justincloncs1116
    @justincloncs1116 ปีที่แล้ว

    Box needs grounded

  • @effthegop
    @effthegop ปีที่แล้ว +2

    No "special tool" required. I retired after 45 years and never used a roto tool. Just bend carefully until the sheath comes apart and snip it with your sharp diagonal cutters. Quicker, easier and no extra cumbersome tools to carry.

    • @tomnorman5461
      @tomnorman5461 ปีที่แล้ว +1

      Although 'dikes' will work in a pinch, a 'ROTO-SPLIT' is faster and does a much 'cleaner' job of stripping the MC.

    • @effthegop
      @effthegop ปีที่แล้ว

      @@tomnorman5461 Sounds like a wager :).
      I'll take it !

  • @stevevojack9092
    @stevevojack9092 2 ปีที่แล้ว +3

    Using the 14 gauge stripper on the 12AWG nicks and compromises the conductor (especially when you rotate it), no anti-short bushing installed. What I expect from a 6 month apprentice.

    • @mattozx6rr
      @mattozx6rr 2 ปีที่แล้ว +3

      The anti short bushing is only required on AC cable. You do not need it on MC cable if you use a roto cutter then clean the square end up for a flush mount in the connector. That said I would still use an anti short bushing just for extra insurance and peace of mind.

  • @JuanGarcia-nj9dk
    @JuanGarcia-nj9dk 3 ปีที่แล้ว

    Whats was your investment this building including your concrete slab?

  • @randellwolfe4555
    @randellwolfe4555 ปีที่แล้ว

    Great video!, helped me as it was first time I have installed outlet in metal box

  • @michaelblanton9782
    @michaelblanton9782 6 หลายเดือนก่อน

    Where is the ground connection to the metal box?

  • @bigbawls81
    @bigbawls81 3 ปีที่แล้ว +1

    Very informative. Thanks for sharing Big Dan.

  • @markdesilvey454
    @markdesilvey454 3 ปีที่แล้ว +6

    Many violations. Nowhere close to a professional install.

    • @Kevin-wj4ed
      @Kevin-wj4ed 4 หลายเดือนก่อน +1

      What are the violations? I want to learn.

  • @heted1
    @heted1 2 ปีที่แล้ว

    Great video. Thanks for sharing.

  • @Trumptrain2024Vance
    @Trumptrain2024Vance 3 ปีที่แล้ว +2

    What company did you use for the building!!!

  • @santiagodominguez2522
    @santiagodominguez2522 3 ปีที่แล้ว

    We build those metal shops where you buy yours

    • @CHEECHMUN
      @CHEECHMUN 3 ปีที่แล้ว

      I bought mine from Eagle Carports. I think you and 2 other guys installed mine in SC!!!

    • @santiagodominguez2522
      @santiagodominguez2522 3 ปีที่แล้ว +1

      @@CHEECHMUN awesome 👌

    • @santiagodominguez2522
      @santiagodominguez2522 3 ปีที่แล้ว

      What city and state

    • @CHEECHMUN
      @CHEECHMUN 3 ปีที่แล้ว

      @@santiagodominguez2522 Nichols, SC

  • @JBarnes917
    @JBarnes917 3 ปีที่แล้ว +5

    Guy didn’t bond the box with the ground.. this is basic NEC code knowledge. You WILL fail an electrical inspection and it’s just not safe. He should stick to changing light bulbs.

    • @ABflanagan523
      @ABflanagan523 3 ปีที่แล้ว +1

      Outlet is grounded due to the yoke making contact with the metallic box. I agree there’s no pigtail from the 12-2 to box and box to outlet but it is grounded, just not the way you’d expect.

    • @JBarnes917
      @JBarnes917 3 ปีที่แล้ว +1

      @@ABflanagan523 wrong… open your code book. 250.148(c) if you have a metal box it needs a ground screw and pig tail. Again this install will fail an inspection.

    • @Faruk651
      @Faruk651 2 ปีที่แล้ว

      @@ABflanagan523 We use metal boxes for residential and commercial in Ontario, Canada. No plastic crap. And we have to ground the metal boxes and devices by code.

    • @ABflanagan523
      @ABflanagan523 2 ปีที่แล้ว +1

      @@JBarnes917 250.146 (A) Surface Mounted Box. Where the box is mounted on the surface, direct metal to metal contact between the device yoke and the box or a contact yoke or a self grounding receptacle shall be permitted to ground the receptacle to the box.

    • @JBarnes917
      @JBarnes917 2 ปีที่แล้ว

      Wrong
      NEC 2005 Handbook commentary:
      The main rule of 250.146 requires an equipment bonding jumper to be installed between the device box and the receptacle grounding terminal. However, 250.146(A) permits the equipment bonding jumper to be omitted where the metal yoke of the device is in direct metal-to-metal contact with the metal device box and at least one of the fiber retention washers for the receptacle mounting screws is removed, as illustrated in Exhibit 250.52.
      Cover-mounted wiring devices, such as on 4-in. square covers, are not considered grounded. Section 250.146(A) does not apply to cover-mounted receptacles, such as the one illustrated in Exhibit 250.53. Box-cover and device combinations listed as providing grounding continuity are permitted.

  • @imbradleymi
    @imbradleymi 3 ปีที่แล้ว

    What box is this? I would like to use them for my shop.

  • @timothymcvay7286
    @timothymcvay7286 3 ปีที่แล้ว

    Awesome video

  • @garagekeys
    @garagekeys 2 ปีที่แล้ว +1

    I don't think you should be using that MC cable if it's not going to be covered up, I thought that it was not supposed to be exposed locations where there can be damage

    • @caliguy1500
      @caliguy1500 2 ปีที่แล้ว +1

      Section 330.15 states: Exposed runs of cable, except as provided in 300.11(A), shall closely follow the surface of the building finish or running boards. Exposed runs shall also be permitted to be installed on the underside of joists where supported at each joist and located so as not to be subject to physical damage.
      Type MC Cable without an outside nonmetallic jacket can be installed in an “other space used for environmental air” in accordance with Section 300.22(C). These cables can be installed either indoors or outdoors and in exposed and concealed locations. ... They can be installed in a cable tray or in any raceway.

  • @OU8Aspark
    @OU8Aspark 3 ปีที่แล้ว

    Can you tie multiple outlets together?

  • @garyhobbs249
    @garyhobbs249 3 ปีที่แล้ว +3

    He didn’t ground the box lmao

    • @morehp1
      @morehp1 3 ปีที่แล้ว +3

      It’s a structure metal building the the panel is grounded to the structure, that box is screwed to the building, metal to metal, it’s grounded.

    • @garyhobbs249
      @garyhobbs249 3 ปีที่แล้ว +2

      If you had your master electrical license then you’d understand

    • @ABflanagan523
      @ABflanagan523 3 ปีที่แล้ว

      @@garyhobbs249 Seems you don’t. I agree good practice would be to run a pigtail from the box to the outlet for a solid ground but with a metallic box and MC it’s an EGC.

    • @JBarnes917
      @JBarnes917 3 ปีที่แล้ว

      @@morehp1 no ground screw or ground tail in box so it’s not bonded. Learn the difference between grounded and bonded…. When you get an electrical license let us all know

    • @garagekeys
      @garagekeys 2 ปีที่แล้ว

      @@morehp1 is that allowed by code?

  • @kenjares6719
    @kenjares6719 3 ปีที่แล้ว

    Thanks. I was looking for this info

    • @barryely1
      @barryely1 ปีที่แล้ว

      There isn't much knowledge here. This video should he deleted. Box isn't bonded and anti short bushing wasn't used. I hope you search for other videos showing the correct way of doing this.

  • @timothymcvay7286
    @timothymcvay7286 3 ปีที่แล้ว

    So how do you wire the panel

    • @JBarnes917
      @JBarnes917 2 ปีที่แล้ว

      If you have to ask here then you shouldn’t be doing it

  • @davidvelen9835
    @davidvelen9835 หลายเดือนก่อน

    Outlet is not bonded to the metal box, wire not wrapped into a "J hook" and attached to the screw terminals correctly. Wiring is no hobby, call an electrician.

  • @surferdude642
    @surferdude642 2 ปีที่แล้ว

    I assume that the box is grounded by the mc, but you should use the ground wire to ground the box and there is no need to attach a wire or pigtail to the receptacle. When the receptacle is mounted to the cover and the cover is mounted to the box everything is grounded. The receptacle has a self grounding strap on the lower yoke. The cover comes with screws and nuts to mount the receptacle securely and you didn't use those. The screw connection between the receptacles becomes optional.
    The 20 amp receptacle is ok, but unnecessary, a 15 amp commercial spec grade would be my choice, 15 or 20 amp circuit, it doesn't matter.

    • @JBarnes917
      @JBarnes917 2 ปีที่แล้ว

      1. You need to learn difference between “grounded” and “bonded”.
      2. That receptacle needs a ground wire going to the box. Please read NEC 250.146, cover mounted wiring devices are NOT considered grounded.

    • @surferdude642
      @surferdude642 2 ปีที่แล้ว

      @@JBarnes917 Thank you for the comment, but I believe that it's justified in this case. See NEC 250.146 exception (A). If he was using a receptacle with a self grounding strap, such as a Leviton spec grade, exceptions (A) and (B) would apply. Am I missing something here?

    • @JBarnes917
      @JBarnes917 2 ปีที่แล้ว

      @@surferdude642
      NEC 2005 Handbook commentary:
      The main rule of 250.146 requires an equipment bonding jumper to be installed between the device box and the receptacle grounding terminal. However, 250.146(A) permits the equipment bonding jumper to be omitted where the metal yoke of the device is in direct metal-to-metal contact with the metal device box and at least one of the fiber retention washers for the receptacle mounting screws is removed, as illustrated in Exhibit 250.52.
      Cover-mounted wiring devices, such as on 4-in. square covers, are not considered grounded. Section 250.146(A) does not apply to cover-mounted receptacles, such as the one illustrated in Exhibit 250.53. Box-cover and device combinations listed as providing grounding continuity are permitted.

  • @trustme7731
    @trustme7731 3 ปีที่แล้ว +14

    Multiple code violations. Leave the electrical work to the professionals.

    • @trustme7731
      @trustme7731 ปีที่แล้ว +1

      @@TheBigDanShow It doesn't meet the NEC requirements which are minimum requirements.
      Fire is not the only hazard with electricity.

    • @jaxchristian6408
      @jaxchristian6408 11 หลายเดือนก่อน +16

      Ya . Keep it a secret. Act like you guys are the only ones that can install an outlet

    • @jessicakeefer5077
      @jessicakeefer5077 3 หลายเดือนก่อน

      Come down on your prices and we will 😌

    • @trustme7731
      @trustme7731 3 หลายเดือนก่อน

      @@jessicakeefer5077 Would you shop for the cheapest heart surgeon?

    • @trustme7731
      @trustme7731 3 หลายเดือนก่อน

      @@jessicakeefer5077 So, you are willing to live with, or die from, illegal electrical work?

  • @oldnbroke1544
    @oldnbroke1544 ปีที่แล้ว

    You should pull this video...box isn't bonded, the receptacle is upside down...you sir are unsafe...