Liquid Control Valve sizing calculation

แชร์
ฝัง
  • เผยแพร่เมื่อ 26 ส.ค. 2024
  • This video is about the basics of control valve sizing and cv value calculation. The way process engineer performs the sizing and hydraulics(pressure drop) calculations.

ความคิดเห็น • 24

  • @vijaysrivatsa3216
    @vijaysrivatsa3216 3 ปีที่แล้ว +1

    Dear sir, I am following your videos to understand these concepts. Request you to make a video on PSV sizing as well

  • @abhishekpandey21790
    @abhishekpandey21790 5 ปีที่แล้ว +4

    Try to cover PSV sizing, Heat exchanger sizing and Line sizing

  • @bbdavallonga
    @bbdavallonga 2 ปีที่แล้ว

    please continue the explanation by saying how you can relate the value found and the valve catalog. up to this point, this is a simple hydraulic exercise...

  • @hardikshah7941
    @hardikshah7941 4 ปีที่แล้ว

    Sir. Good information shared. Thanks for updating our knowledge.

  • @prasadadavi6618
    @prasadadavi6618 ปีที่แล้ว +1

    Dear sir, I believe if the losses due to friction inside the pipe are negligible, then Darcy calculations can be ignored. Your opinion please

  • @nausheenshaikh2298
    @nausheenshaikh2298 4 ปีที่แล้ว +1

    Sir it was a nice video. Can you please make a video on temperature control valve on reboiler inlet of a column. Also mention concepts of temp and velocity

  • @vysakhmohan5109
    @vysakhmohan5109 5 ปีที่แล้ว +2

    Sir excellent video .. do u have tutorial for heat exchanger calc. , Line sizing, psv sizing,

    • @lokeshkumarsingh9636
      @lokeshkumarsingh9636  4 ปีที่แล้ว

      I will upload many mores which will cover whatever you can expect as a process Engineer

    • @pranali6meshram707
      @pranali6meshram707 3 ปีที่แล้ว

      @@lokeshkumarsingh9636 plz tell me psv sizing...vessel sizing...heat exchanger plz upload

  • @engineersingulf6968
    @engineersingulf6968 6 ปีที่แล้ว

    very nice video...keep making more videos. i have a question for you kindly tell me how to size a three way of 2 way control valve in chilled water system. before evaporator coil of AIR HANDLING UNIT. here you do calculation for open loop system but how to calculate del p in closed loop system....

    • @lokeshkumarsingh9636
      @lokeshkumarsingh9636  6 ปีที่แล้ว

      I will try to upload a video on this to make your understanding for sizing and hydraulic calculation for sizing close loop control valve

  • @anandh1967
    @anandh1967 ปีที่แล้ว

    Incase of laminar flow the pressure drop is directly proportional to CV ..in that case how to calculate flow rate

  • @Arizona807
    @Arizona807 ปีที่แล้ว

    Dear sir please upload the continuation video for this

  • @vaibhavmundekar8528
    @vaibhavmundekar8528 3 ปีที่แล้ว

    Sir, pls give complete calculation for this topics.
    Step by steps

  • @subratadalui5390
    @subratadalui5390 ปีที่แล้ว

    Please calculate the P1 value

  • @movielibraries5302
    @movielibraries5302 3 ปีที่แล้ว

    i gess darcy is used for gases?

  • @sathishvmanohar9434
    @sathishvmanohar9434 4 ปีที่แล้ว +1

    Correct the cv formula.

  • @DheerajKumar-ug2uh
    @DheerajKumar-ug2uh 5 ปีที่แล้ว

    Hello sir can u please upload Cv sizing for gas

  • @Theanvcorporation
    @Theanvcorporation 3 ปีที่แล้ว

    Cv formula does not seem right

  • @bablukumarofficial4889
    @bablukumarofficial4889 5 ปีที่แล้ว +3

    Bad