The presure will vary high/low depending on the refrigerant. But typically at the discharge side of compressor is the high pressure high temperature gas . Low pressure low temperature gas is found as it leaves the evaporator coil
@@shiddy. not at all the 4 way valve is just a bi -pass to different coils . The pressure is essentially the same operating pressure as a conventional a/c system . The valve adds no pressure , if anything it may decrease only cause of resistance. R-11,R-12, operating pressure is much lower than say R-22 in residential A/c , but R-410A operates higher than R-22 . So you need a pressure/temperature chart to be familiar with corresponding refrigerant s
I have a heat pump system already running - it even heats the house when it's -5F outside before the system switches to a gas furnace - it's a new system just a few months old, but I'm very impressed with it so far this winter in minnesota ... just wondering how some of it works - great video 👍
Hello sir the veidos u make we understand easily please make more Vedio related HVAC FCU FAHU AHU CHILLER AND CHILLER PUMP FUNCTIONS AND VFD SPLIT UNIT WINDO AND VRV VRF please
The Refrigeration Cycle working principle.
th-cam.com/video/4vpmztdNY6o/w-d-xo.htmlsi=-8Qi3cZQj5VZeBSd
Very helpful your video. Thank you so much.
You are welcome!
Nice information knowledge
Thank you 😊
Amazing video! Your insights and explanation were really helpful!🎉🎉🎉🎉
Thank you so much! I'm glad you found it helpful. 😊
Thank you so much for this video, can please make another video how the wiring diagram works of four way valve
Good question, that's a good idea for another video.
Yes I second that request, as you are very thorough in all your video descriptions. Much appreciated @@zebralearnings
Thanks for your video ❤
Thank you 😊
Thank you so much sir ji ❤
Most welcome
Please make a complete video on VRV/VRF.Cooling system, heat pump and heat recovery.It is not easy to me to understand.THANKS a lot
Great video
Thank you 😊
Pls explain what are the parameter we have to considered for air cooled and water cooled chiller
what pressure does the system commonly operate at on both sides of the pump?
The presure will vary high/low depending on the refrigerant.
But typically at the discharge side of compressor is the high pressure high temperature gas . Low pressure low temperature gas is found as it leaves the evaporator coil
@jamesortolano3983 is the refrigerant at a higher pressure than a traditional AC system? is it a different refrigerant?
thank you
@@shiddy. not at all the 4 way valve is just a bi -pass to different coils . The pressure is essentially the same operating pressure as a conventional a/c system . The valve adds no pressure , if anything it may decrease only cause of resistance.
R-11,R-12, operating pressure is much lower than say R-22 in residential A/c , but R-410A operates higher than R-22 .
So you need a pressure/temperature chart to be familiar with corresponding refrigerant s
I have a heat pump system already running - it even heats the house when it's -5F outside before the system switches to a gas furnace - it's a new system just a few months old, but I'm very impressed with it so far this winter in minnesota ... just wondering how some of it works - great video 👍
Vídeo excelente o que é melhor posso ouvi- Los em português
What's the meaning of offset,remote range in York chiller evaporator parameter
Hello sir the veidos u make we understand easily please make more Vedio related HVAC FCU FAHU AHU CHILLER AND CHILLER PUMP FUNCTIONS AND VFD SPLIT UNIT WINDO AND VRV VRF please