Down and Dirty with Dave- Episode 12 Outrigger Leveling Genie GS-3232

แชร์
ฝัง
  • เผยแพร่เมื่อ 15 ม.ค. 2025

ความคิดเห็น • 15

  • @curious-homebody
    @curious-homebody ปีที่แล้ว +1

    Thank you for this video. This is very informative. The music is like 3 times louder than you by the way. I hit that sub button for good measure.

  • @larryh451
    @larryh451 ปีที่แล้ว

    This shows how to level it from one end to the other but it seems more likely that if it was going to tip it would be toward the side or the narrow dimension. Is there a way to level side to side?

    • @aerialliftrepairs
      @aerialliftrepairs  ปีที่แล้ว

      The machine has automatic leveling so I can level in either direction. While the outriggers do compensate for some slope their main purpose is to stabilize the machine due to how narrow it is. The Genie GS-3232 is a unique machine that goes up to a 32ft platform height at just 32 inches wide.

  • @jacoblarry238
    @jacoblarry238 ปีที่แล้ว +1

    Safe to say only hard surfaces?

    • @aerialliftrepairs
      @aerialliftrepairs  ปีที่แล้ว +1

      That's correct. All aerial lifts are designed to be used only on firm level surfaces. This machine will allow use on moderate slopes.

    • @Pevach1
      @Pevach1 ปีที่แล้ว

      Our riggers are down but wont raise the platform

    • @aerialliftrepairs
      @aerialliftrepairs  ปีที่แล้ว

      ​@@Pevach1 did you get your machine functioning correctly? If not give us a ring and let's get your service scheduled.

  • @joshalo16
    @joshalo16 ปีที่แล้ว

    Does the outriggers need to be out to go the full 32 feet ?

    • @aerialliftrepairs
      @aerialliftrepairs  ปีที่แล้ว

      Yes. The machine will drive up to 26feet depending on the model year.

  • @christophermay5877
    @christophermay5877 ปีที่แล้ว

    How do I manually lower the outriggers when they are stuck out

    • @aerialliftrepairs
      @aerialliftrepairs  ปีที่แล้ว

      If they are stuck you would have the release the pressure on the holding valves on the individual outrigger cylinders. More than likely if they won't retract it is an issue withe pressure transducers, limit switches in your pothole protection or a software update. If you're around the great Chicagoland area give us a ring and we can get you scheduled for service to repair any issues you have.

  • @lavozdetusubconsciente5477
    @lavozdetusubconsciente5477 10 หลายเดือนก่อน

    Do you know why my GS 3232 works with the stabilizers but does not want to go up and if I pick up the stabilizers it goes up but only up to 6.9 meters.

    • @aerialliftrepairs
      @aerialliftrepairs  9 หลายเดือนก่อน

      Improper calibration of a limit switch or sensor.

  • @CarnellaMarks
    @CarnellaMarks ปีที่แล้ว

    I have a 2632 and it giving me a code CO10 Secondary not programmed. How do I fixed that

    • @aerialliftrepairs
      @aerialliftrepairs  11 หลายเดือนก่อน

      Call our office at 708-279-7574 and ask for service.