How to make Water Pump Automatic Switch ON-OFF Circuit | Water Level Controller with 555

แชร์
ฝัง
  • เผยแพร่เมื่อ 27 เม.ย. 2024
  • In this project, I have shown how to make water pump automatic switch ON-OFF circuit to control the water level automatically. I have used the 555 timer IC for this DIY water pump auto cut switch circuit.
    With this simple 555 timer circuit, we can stop the water overflow from the water tank. And the pump will automatically start if the water level becomes low. So we don't need to start and stop the pump manually.
    I have published a new water pump controller circuit with more features. Please click the following link to watch the tutorial.
    • Automatic Water Pump C...
    New water pump controller using Arduino
    • Automatic Water Level ...
    Download the PCB Layout for Automatic ON\OFF water pump switch from the following article
    easyelectronicsproject.com/mi...
    Required components for the water pump automatic control circuit
    1. 555Timer IC (1no)
    2. BC547 NPN Transistor (1no)
    3. 1k 0.25watt Resistors (R5, R7) (2no)
    4. 22k 0.25watt Resistors (R1, R2) (2no)
    5. 180k 0.25watt Resistor (R6) (1no)
    6. 1M 0.25watt Resistors (R3, R4) (2no)
    7. 100nF (104) Capacitor (C4) (1no)
    8. 1N4007 Diode (D6) (1no)
    9. LED 1.5V (1no)
    10. 12V SPDT Relay (1no)
    11. Connectors & IC base (4pin)
    12. Zero PCB
    Here, I have used a 5V pump to show the operation, but you can also use any single-phase pump. Please select the relay as per the voltage and current rating of the pump.
    After watching the video, you can easily design this automatic water tank level controller motor driver circuit for your home.
    If you face any issue please let me know in the comment section.
    #waterpumpautocutswitch #waterpumpautoonoff
    ------------------------------------------------------
    Thanks For Watching...
    ✅ SUBSCRIBE ✅LIKE ✅SHARE ✅ COMMENTS
    Website: easyelectronicsproject.com/
    Facebook: / techstudycell
    Instagram: / techstudycell
    Telegram: t.me/techstudycell/
    -------------------------------------------------------
    Other useful videos:
    LM317 variable DC Power Supply with circuit diagram
    • How to make LM317 vari...
    How to calculate resistor value for LEDs in a circuit for 9V and 12V
    • How to select resistor...
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 774

  • @TechStudyCell
    @TechStudyCell  10 หลายเดือนก่อน +2

    Watch [NEW] video on Fully Automatic Pump controller: th-cam.com/video/bgARqosK7T4/w-d-xo.html

  • @PerchEagle
    @PerchEagle 3 ปีที่แล้ว +7

    I learned the difference between TRIG and THR, thanks :)

  • @raveendranc285
    @raveendranc285 3 ปีที่แล้ว +17

    You have a great quality of helping others, keep it up. Thank you man.

    • @msh1830
      @msh1830 ปีที่แล้ว

      th-cam.com/video/a_Bfu1XWGmI/w-d-xo.html
      watch last 30 second of my video. i explained state table and state diagram

  • @turiyathe4th
    @turiyathe4th 9 หลายเดือนก่อน

    That pcb is a thing of beauty

  • @SanjayKumar-mz3wx
    @SanjayKumar-mz3wx 2 ปีที่แล้ว

    बहुत सरलता से समझाया आपने, धन्यवाद |

  • @homoudalyahya4618
    @homoudalyahya4618 3 ปีที่แล้ว +14

    Great video, very clear demonstration, and above all sharing the PCB diagram. Thank you so much.

    • @TechStudyCell
      @TechStudyCell  3 ปีที่แล้ว +1

      Glad it was helpful!

    • @homoudalyahya4618
      @homoudalyahya4618 3 ปีที่แล้ว +1

      @@TechStudyCell I am trying to replace the pump with a solinoid valve. I have just completed the collection of needed items, but unfortunately I got 1.2k resistors instead of the 1k. I wonder if that is okay and if the circuit will work with the solinoid valve. You help in answering my questions will be highly appreciated.

    • @bappaelectric305
      @bappaelectric305 2 ปีที่แล้ว

      Bro 1 question answer please, isme components me 1k, 22 k, 180k,1m, sub 0.25w compalsary hai kya 1/4 w nhi chalega kya or, 2 question answer please, me isme 6v ka relay use kar raha hu ku problem tho nhi hoga na, resistance ka velue change kar na padega kya , capacitor ka bhi bolo,

    • @sitaramkolte6403
      @sitaramkolte6403 2 ปีที่แล้ว

      @@TechStudyCell it is circuit for motor upto 1hp or not

    • @msh1830
      @msh1830 ปีที่แล้ว

      th-cam.com/video/a_Bfu1XWGmI/w-d-xo.html

  • @adnansikandar2332
    @adnansikandar2332 3 ปีที่แล้ว +16

    The common, pump ON and Pump off wires will get oxidation after some time due to electrolysis process.

  • @Ezee-xm7yn
    @Ezee-xm7yn 3 ปีที่แล้ว +1

    hi and thanks for a lovely easy to follow video im looking at making this can i use these Liquid Level Sensor Controller Plastic Ball Float instead of the 3 wires

  • @yogeshlekhadia7742
    @yogeshlekhadia7742 3 ปีที่แล้ว

    Thank you for your answer. 30Amp Relay se single phase capacitor start monoblock 1Hp 7Amp ki Do (2) motor Ek saath chala sakte hai? Aur circuit ko auto aur manually kar ne ke liye switch kai se lagae?

  • @arumkumarbhattacharya7773
    @arumkumarbhattacharya7773 3 ปีที่แล้ว +1

    I'm a hobbyist, and this video attracts me. Now I want to make this project. Where I can get all the components (without the 230v pump) in on one package, can you help?

  • @user-it3od9nt7b
    @user-it3od9nt7b 3 ปีที่แล้ว

    ThIs is a great video so far for automatic water control. It is not easy to understand schmatic. Would you kindly explain how automatic water control with 555 timer ic ?
    Please, explain the schmatic in detail.
    Thank you,

  • @Prof.Hassan
    @Prof.Hassan 2 ปีที่แล้ว

    Thank you for this video
    I have a question please
    How much the voltage between the cathods placed in the watter ?

  • @teobenedict1733
    @teobenedict1733 2 ปีที่แล้ว

    Hi, to power thr 5V water pump did you use a 5V AC/DC adaptor connected to the main?

  • @dwiindri3491
    @dwiindri3491 3 ปีที่แล้ว

    Terimakasih telah membuat rangkaian on of water pimp saya akan mencoba membuat untuk tandon air 👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍

  • @jpscafe7648
    @jpscafe7648 3 ปีที่แล้ว +2

    Show de bola falou e disse! Belíssimo projeto. Br.

    • @msh1830
      @msh1830 ปีที่แล้ว

      th-cam.com/video/a_Bfu1XWGmI/w-d-xo.html

  • @nageshgaikwad6547
    @nageshgaikwad6547 3 ปีที่แล้ว +1

    How much capacity of capacitor you have added in series with positive and ic

  • @mentesanayamor
    @mentesanayamor ปีที่แล้ว +1

    What type of engine do you use in this video to fill the water container?

  • @herbertstolz1097
    @herbertstolz1097 2 ปีที่แล้ว +9

    If you swap the depth of the Red and Green wire in the Tank, you can change the pump to be a bulge pump for boats but put the pump in the tank. Once the water fills the boat and water reaches the green wire which is your safe maximum level of water, then you will trigger the circuit which will keep pumping till the water falls below the red wire and will turn the circuit off. As water fills in again, and reaches tge red, nothing will happen. But when the water reaches the Green wire, you will trigger the circuit and tge pump will run pumping the water out till it drops below the Red and Green wires.
    Give it a go.

    • @A-ZEE.
      @A-ZEE. 2 ปีที่แล้ว

      YOU DID THIS PRACTICALLY, I MEAN IT WILL WORK 100% SAME HAS YOU DISCrIBE

    • @rohanparashar8232
      @rohanparashar8232 ปีที่แล้ว +1

      It won't work that way. As soon as the green wire looses contact with water, the pump will start.
      We'd need circuit modifications to achieve a bulge pump function.

    • @tomk1s
      @tomk1s 10 หลายเดือนก่อน

      @@rohanparashar8232 yep thats true, but i can not find the tutorial for bulge pump function. :/

  • @revathielam8130
    @revathielam8130 3 ปีที่แล้ว +1

    Your teach very ease,thanks you,

  • @chrischristodoulou1731
    @chrischristodoulou1731 2 ปีที่แล้ว +1

    Does the position of reference electon in the water matter?

  • @rangka-ESAF
    @rangka-ESAF 2 ปีที่แล้ว +1

    Thank you, I'm using your design as a basis for my home water well pump on/off control and it works perfectly.

    • @TechStudyCell
      @TechStudyCell  2 ปีที่แล้ว

      Great to hear!

    • @kshitijsonar4294
      @kshitijsonar4294 ปีที่แล้ว

      Can I real use this for ac motor ?

    • @rangka-ESAF
      @rangka-ESAF ปีที่แล้ว

      @@kshitijsonar4294 yes, im using this for 200 watt ac pump, so far no trouble. But first please select suitable relay for your pump.

    • @kshitijsonar4294
      @kshitijsonar4294 ปีที่แล้ว

      Which relay will be the best for common water pump

    • @rangka-ESAF
      @rangka-ESAF ปีที่แล้ว

      @@kshitijsonar4294I'm really not an expert in this, im using cheap 5v relay, as long as it fits the pump rating. But to be safe, you can ask your local electronic store.

  • @philipabraham7474
    @philipabraham7474 3 ปีที่แล้ว

    A honest and clear demonstration thanks good job best regards

    • @TechStudyCell
      @TechStudyCell  3 ปีที่แล้ว

      You are welcome

    • @bappaelectric305
      @bappaelectric305 2 ปีที่แล้ว

      Bro 1 question answer please, isme components me 1k, 22 k, 180k,1m, sub 0.25w compalsary hai kya 1/4 w nhi chalega kya or, 2 question answer please, me isme 6v ka relay use kar raha hu ku problem tho nhi hoga na, resistance ka velue change kar na padega kya , capacitor ka bhi bolo,

    • @mr.bhadauriya2003
      @mr.bhadauriya2003 หลายเดือนก่อน

      Sir please contact Krna ha aap se

    • @mr.bhadauriya2003
      @mr.bhadauriya2003 หลายเดือนก่อน

      Please sir please 🥺

  • @eddiemolina657
    @eddiemolina657 2 ปีที่แล้ว +2

    May I suggest, you could put a drain pipe with a height of 35cm above the bottom of the tub. Then you may attach to the drain pipe a N/O mini gas solenoid valve to it & then on of its lead wires is the same attachment to your water pump. So if the water pump is turned on, simultaneously the solenoid valve shuts off not letting water out & as the water pump turned off the solenoid valve opens & releases water onto the reservoir bellow & the cycle repeats as the controller dectects that the water in the tank is low.
    I hope it works.👊😁

    • @msh1830
      @msh1830 ปีที่แล้ว

      th-cam.com/video/a_Bfu1XWGmI/w-d-xo.html
      watch last 30 second of my video. i explained state table and state diagram

  • @MarcusIIFerreira
    @MarcusIIFerreira 2 ปีที่แล้ว

    Can I use magnetic sensor level and put the two negatives COM together?

  • @tristanmcmillan2007
    @tristanmcmillan2007 7 หลายเดือนก่อน

    How do you reverse it so it takes water out the tank till its empty then refill and empty again.

  • @A.S.khojaryavrat
    @A.S.khojaryavrat 2 หลายเดือนก่อน

    सुन्दर है भाई साहब जी सर्किट

  • @sampathhewawitharana8573
    @sampathhewawitharana8573 3 ปีที่แล้ว +2

    The most appreciate thing is your eendless feedback and lovely replies. I subcribed and thumbs up. Proceed. Godbless.

    • @TechStudyCell
      @TechStudyCell  3 ปีที่แล้ว

      Thank you

    • @SPECIALVIDEO
      @SPECIALVIDEO 2 ปีที่แล้ว

      www.amazon.in/gp/product/B08QZK2NG8/ref=cx_skuctr_share?smid=A2EY6UBWCE41I5

  • @saralprabidhi1889
    @saralprabidhi1889 2 ปีที่แล้ว

    Thank you!

  • @guruganapathy8900
    @guruganapathy8900 2 ปีที่แล้ว

    Suggest for auto cutoff if manually switched on motors since water scarsity may occur in next year

  • @simeonerasmus
    @simeonerasmus ปีที่แล้ว

    First off, great video thank you. Secondly, hiw can i change this so the pump turns off when the water level meets the middle wire and turns on when the water meets the top?

  • @shvideo1
    @shvideo1 2 ปีที่แล้ว +2

    How so creative and neat. Great job my friend! Thank you for sharing.

  • @TourGuideAynaeChitral
    @TourGuideAynaeChitral 2 ปีที่แล้ว

    Nice idea pr bc547 tranister kay jagy me konsa tranister use karsakta hun?????

  • @rodym1681
    @rodym1681 2 ปีที่แล้ว

    Can you please explain how it works and for each component

  • @carloscesarTHEBEST
    @carloscesarTHEBEST 2 ปีที่แล้ว

    Genial, otimo, perfeito, like like like

  • @nahidnewaz6917
    @nahidnewaz6917 2 ปีที่แล้ว

    Great work brother. But can you help to fix below
    Reserve tank sensitivity
    Voltage sensitivity

  • @TheZincalloy
    @TheZincalloy 3 ปีที่แล้ว +1

    Could this be made to work to drain water out when it is full. and stop whe the tub is empty

  • @abdurrahmansarker3179
    @abdurrahmansarker3179 7 หลายเดือนก่อน

    Can i use this circuit as my home 1.5 Hp water pump?
    and will it work properly?

  • @sarabjitsinghsondhi5960
    @sarabjitsinghsondhi5960 2 ปีที่แล้ว

    Simple and well executed

    • @msh1830
      @msh1830 ปีที่แล้ว

      th-cam.com/video/a_Bfu1XWGmI/w-d-xo.html
      watch last 30 second of my video. i explained withstate table and state diagram

  • @ahmadsubhi3293
    @ahmadsubhi3293 3 ปีที่แล้ว +2

    How to add water pump dry protection when water tank source is empty,help me sir

  • @winniekumar5291
    @winniekumar5291 2 ปีที่แล้ว

    Hi, great video.
    Can you make one with solar panels and 12v battery to charge.

  • @shekarv8738
    @shekarv8738 3 ปีที่แล้ว +2

    Hi dear, I like it today. I ll assemble tomorrow.

    • @AnandaRajaT
      @AnandaRajaT 3 ปีที่แล้ว

      Whether it has worked

  • @adhithyasenanayake2413
    @adhithyasenanayake2413 3 ปีที่แล้ว

    Is it okay to use a 100uf 16v capasitor instead of 104pf

  • @telugutechgear5932
    @telugutechgear5932 3 ปีที่แล้ว +1

    Hats off brother 👏

  • @istechnologyeurl9098
    @istechnologyeurl9098 3 ปีที่แล้ว +1

    thank you man

  • @eshwari-sc5nk
    @eshwari-sc5nk 3 ปีที่แล้ว +1

    Sir I try super working

  • @eissaahmmadi3595
    @eissaahmmadi3595 2 ปีที่แล้ว

    Thank you sir

  • @rajibkarmakar5764
    @rajibkarmakar5764 2 หลายเดือนก่อน

    12V DC supply will be for both Pump and Circuit or only for the circuit?

  • @jaimecases3426
    @jaimecases3426 7 หลายเดือนก่อน

    Hi is this project possible for arduino uno?

  • @drewromero4688
    @drewromero4688 2 ปีที่แล้ว

    Why is there a need for 2 power sources and what voltage does each power source need to be?

  • @denzelkpeli2973
    @denzelkpeli2973 11 หลายเดือนก่อน

    Please if i want to add a buzzer where should i put it in your circuit and also I’m hoping it sounds for some seconds

  • @draculadrac9566
    @draculadrac9566 ปีที่แล้ว

    Can u please share us the design with equations its necessary for doing it as project in collegs

  • @budionohadisuwarno7029
    @budionohadisuwarno7029 2 ปีที่แล้ว

    apakah dapat di gunakan untuk saklar otomatis pompa air arus ac 220v bro?

  • @sidtube12
    @sidtube12 2 ปีที่แล้ว +1

    Great! I love this project. Thanks,

    • @TechStudyCell
      @TechStudyCell  2 ปีที่แล้ว

      Welcome

    • @BalintNandori
      @BalintNandori 2 ปีที่แล้ว

      @@TechStudyCell can I also use this circuit for draining water? If I can i just have to use the normally closed "nc" pin of the relay?

    • @bappaelectric305
      @bappaelectric305 2 ปีที่แล้ว

      Bro 1 question answer please, isme components me 1k, 22 k, 180k,1m, sub 0.25w compalsary hai kya 1/4 w nhi chalega kya or, 2 question answer please, me isme 6v ka relay use kar raha hu ku problem tho nhi hoga na, resistance ka velue change kar na padega kya , capacitor ka bhi bolo,

  • @djmangalaofficialt.s.m9137
    @djmangalaofficialt.s.m9137 ปีที่แล้ว

    Please I want to used 220v water pump machine, which relay should I use in the circuit board

  • @bhavyadoshi4111
    @bhavyadoshi4111 ปีที่แล้ว +1

    Please let me know that the power supply wire is directly be plugged in the swich board or you use the battery

    • @bhavyadoshi4111
      @bhavyadoshi4111 ปีที่แล้ว +1

      Please reply me urgently i have to show this tomorrow in the school

  • @wasiljaved4600
    @wasiljaved4600 3 ปีที่แล้ว +2

    Sir good job, i have question that the supply in for pump is for what purpose if you have already given the supply to the pump?

    • @sathyamurthyponniah124
      @sathyamurthyponniah124 2 ปีที่แล้ว

      @wasil Javed please note that only the
      neutral is connected to the pump. The phase will be connected after the relay
      switches ON ! If you wish , you could employ a Double Pole Solenoid/Relay
      instead of the single pole solenoid.

  • @sdadapeersdadapeer1590
    @sdadapeersdadapeer1590 2 ปีที่แล้ว +2

    Good job thanks

  • @syedmohammadimran5151
    @syedmohammadimran5151 2 ปีที่แล้ว

    For this you have to continuesly pass 12 volt current through the water that has to be use for drinking purpose

  • @liamstone3437
    @liamstone3437 ปีที่แล้ว +1

    This looks like a useful circuit to keep a tank topped off but how about a circuit that pumps water out and shuts off when it reaches a certain level? I would use such a circuit for a 12V 20A bilge pump. I would love to see your version and when I make my bilge system I could link to your tutorial in my own video.

    • @azamchishty6129
      @azamchishty6129 ปีที่แล้ว

      Did you make one?

    • @liamstone3437
      @liamstone3437 ปีที่แล้ว

      @@azamchishty6129 not yet. Still working on it

  • @SuperThirugnanam
    @SuperThirugnanam 8 หลายเดือนก่อน

    Super demo.

    • @moseslawrence9200
      @moseslawrence9200 8 หลายเดือนก่อน

      Please my question is what to w collect to the "SUPPLY FOR PUMP" is that a switch?

  • @youknowme6780
    @youknowme6780 2 ปีที่แล้ว +1

    Great work around, how about auto on/off switch for exhaust fan after every 30 min circuit with 220V for fan? any suggestions

    • @GOPALJHAlife
      @GOPALJHAlife 2 ปีที่แล้ว

      use nodemcu+relay and flash with sincric pro control or set routine on google assistant on your phone for the way you want for free.

    • @GOPALJHAlife
      @GOPALJHAlife 2 ปีที่แล้ว

      alternatively use 555+relay and set it for half hour astable multivibrator output controllong relay

  • @siroedhiekreasi
    @siroedhiekreasi 3 ปีที่แล้ว

    Thanks for your sharing, i wanna try it at home

    • @TechStudyCell
      @TechStudyCell  3 ปีที่แล้ว

      Please do!

    • @bappaelectric305
      @bappaelectric305 2 ปีที่แล้ว

      Bro 1 question answer please, isme components me 1k, 22 k, 180k,1m, sub 0.25w compalsary hai kya 1/4 w nhi chalega kya or, 2 question answer please, me isme 6v ka relay use kar raha hu ku problem tho nhi hoga na, resistance ka velue change kar na padega kya , capacitor ka bhi bolo,

  • @vigneshwaroffcial6798
    @vigneshwaroffcial6798 3 ปีที่แล้ว

    Sir please tell me...this circuit is work in 1 amps

  • @achayanfromkottayam5559
    @achayanfromkottayam5559 3 ปีที่แล้ว +2

    I like ur plastic and papers pcb idea👍👍👍

  • @arslannaseer898
    @arslannaseer898 ปีที่แล้ว

    Aoa, bro pf 104 is not available in market, please advice for alternative uf capacitor plz

  • @bluestack1123
    @bluestack1123 2 ปีที่แล้ว

    can be used on 2 Horse power Water Pump (i.e. 6 to 9 ampere)?
    any component need to be replaced else SPDT Relay ? and what Relay can be used to support maxximum of 9 amperes for 30 minutes until the water tank is filled as per the censor wire.
    Look to hear for experts.

  • @shahzadsadiq126
    @shahzadsadiq126 11 หลายเดือนก่อน

    Is the same reply 250VAC 7A, will work on my 880 WATT [220V 4A]

  • @aroldomarquesdeoliveira8697
    @aroldomarquesdeoliveira8697 2 ปีที่แล้ว

    Fantástico.

  • @aviseksinha9317
    @aviseksinha9317 3 ปีที่แล้ว +1

    Is it necessary to add led ?

  • @illia54
    @illia54 3 ปีที่แล้ว +1

    Excellent circuit

    • @TechStudyCell
      @TechStudyCell  3 ปีที่แล้ว

      Thanks

    • @bappaelectric305
      @bappaelectric305 2 ปีที่แล้ว

      Bro 1 question answer please, isme components me 1k, 22 k, 180k,1m, sub 0.25w compalsary hai kya 1/4 w nhi chalega kya or, 2 question answer please, me isme 6v ka relay use kar raha hu ku problem tho nhi hoga na, resistance ka velue change kar na padega kya , capacitor ka bhi bolo,

  • @jsgallery194
    @jsgallery194 2 ปีที่แล้ว +1

    Is it possible for AC supply with the same diagram. If yes, then is there any possibilities for leakage if electric current in the water tank?

  • @maksudrakib9959
    @maksudrakib9959 11 หลายเดือนก่อน

    Supply for the pump is used in AC or DC?
    Can it possible by 9v battery and 5v relay?

  • @dishantkashyaprock
    @dishantkashyaprock หลายเดือนก่อน

    Can you tell me any idea
    Motor turn off when water full
    But motor should only run on specific time like from 6 to 7 am and when tank full it auto off

  • @karunakaranrajakannu3346
    @karunakaranrajakannu3346 3 ปีที่แล้ว +1

    This will use only for user Store tank what about main Storage tank and also dry run pump protector we need it

    • @anandjoshi8554
      @anandjoshi8554 ปีที่แล้ว

      use a nc float switch at under ground water tank ...connected in between power supply to the circuit.

  • @Kenjiro25
    @Kenjiro25 9 หลายเดือนก่อน

    Hi, thanks for sharing, justa doubt; this project works with 110-120v too?

    • @TechStudyCell
      @TechStudyCell  9 หลายเดือนก่อน

      Please check out latest video on this th-cam.com/video/bgARqosK7T4/w-d-xo.html

  • @RainOoOb
    @RainOoOb 4 หลายเดือนก่อน

    Can you tell me the functions of resistors, capacitors, transistors, and diodes in this electronic circuits?

  • @mmtechchannel8002
    @mmtechchannel8002 ปีที่แล้ว

    Dear Sr.What software do you use for skill size mm × mm on A4 or Docx.

  • @dz-abouttechnique1849
    @dz-abouttechnique1849 11 หลายเดือนก่อน

    Great video!

  • @shija1999
    @shija1999 2 หลายเดือนก่อน

    Hi..Why cant we incorporate a 12v supply on the board itself instead of giving a separate power supply point for the 12v.
    The circuit diagram should be modified for only 220v input with required components on board for automatic voltage reduction wherever required.

  • @sghyrhicham7011
    @sghyrhicham7011 2 ปีที่แล้ว

    Tank you very match

  • @paramjitsingh137
    @paramjitsingh137 2 ปีที่แล้ว

    Good device but I had to add two 1mfd capacitor accross common and start, stop connections to avoid random start and stop due to electric jerk.

  • @guneetsingh7750
    @guneetsingh7750 2 ปีที่แล้ว

    i have a question, how can i make a circuit that automatically turns a 18w water pump on and off for 15 minutes every hour ,24x7?

  • @karandesai8961
    @karandesai8961 2 ปีที่แล้ว

    How to use it for 5hp pump, which relay should i use

  • @jamesmyrthong6112
    @jamesmyrthong6112 2 ปีที่แล้ว

    Superb video And also the background music. Thank You tech study cell.

    • @TechStudyCell
      @TechStudyCell  2 ปีที่แล้ว

      Welcome

    • @bappaelectric305
      @bappaelectric305 2 ปีที่แล้ว

      Bro 1 question answer please, isme components me 1k, 22 k, 180k,1m, sub 0.25w compalsary hai kya 1/4 w nhi chalega kya or, 2 question answer please, me isme 6v ka relay use kar raha hu ku problem tho nhi hoga na, resistance ka velue change kar na padega kya , capacitor ka bhi bolo,

  • @josebolanos3091
    @josebolanos3091 3 ปีที่แล้ว

    there I have an idea for another project, and so you do it is a controller for a voltage stabilizer system with transformers

  • @delrstudio.2252
    @delrstudio.2252 3 ปีที่แล้ว

    Thank you very much

  • @konghwathai8994
    @konghwathai8994 3 ปีที่แล้ว +2

    Excellence mantor.

  • @davidsiaw9431
    @davidsiaw9431 ปีที่แล้ว

    Can it be applied to huge water pumps please

  • @chibunna_ea
    @chibunna_ea 10 หลายเดือนก่อน

    Does this work because water conduct electricity or what?
    And will this work on other liquids?

  • @himanshuchaudhary1857
    @himanshuchaudhary1857 3 ปีที่แล้ว +3

    What changes i have to do to o use it for AC submersible pump?

  • @zicuh
    @zicuh 6 หลายเดือนก่อน +2

    Brub i got 6th place for this participating in state electronics work experience fair 🎉😊

  • @diyandassembling2907
    @diyandassembling2907 3 ปีที่แล้ว

    Very helpful.

  • @bsrihari554
    @bsrihari554 ปีที่แล้ว

    If we it on big water tanks we high voltage when it attempts to current shock

  • @pradippaul2186
    @pradippaul2186 ปีที่แล้ว

    Is circuit me 230 v AC pump use kar sakhte he kya

  • @EELEC19
    @EELEC19 ปีที่แล้ว

    What is your supply is it 220VAC INPUT AND 12 DC OUTPUT?

  • @rayhan_ahmad
    @rayhan_ahmad 11 หลายเดือนก่อน

    Is there any chance of electrical shock in the sensor terminal?? Cause after making this circuit if i attach the phase line on relay it shock in the water, but if i attch the phase line on the pump than it dont shock. What is the problem and what is the solution

  • @abufahad.a6611
    @abufahad.a6611 5 หลายเดือนก่อน

    Can we use this procedure for ac motors?

  • @maheshraaz4915
    @maheshraaz4915 ปีที่แล้ว

    What are the main supplies kindly tell us ...is there and ac power supply ?

  • @joshitoshi9835
    @joshitoshi9835 3 ปีที่แล้ว

    thanks for the tut, but can u make another video with LoRa module, lcd screen and leds to show water level and automatic on/off, and also having manual switch to turn on/off the motor at any time?

  • @itz.imran84
    @itz.imran84 8 หลายเดือนก่อน

    Bhai ye circuit buy kar skte hai kya