@@LeeThayer-nn5yeDid this work when lights cut off and come back on? Suppose the pump was ON (that is the water level is below the top sensor wire) and then electricity cut off and come back on again.. will the pump still be on?
I made and working perfectly fine... If you add 1 more function for municipal water supply and submersible auto on off function then this will work all conditions.. Hatsoff brother..
Very good project, but please help me solve one problem, why my relay keeps switching on and off rapidly after the tank is full?Please help me ,thank you.
How to add one more sensor to the overhead tank? This sensor should cut off the power to the pump once it gets in contact with water. This is so that if the pump switches on after power failure, the tank still won't overflow. Hope someone comes up with this
Hello, please reply, I have a question: Will this work when electricity cuts off and on? Suppose, The pump was ON, that means, the water level was below TOP and pump was ON then electricity cut OFF and later came ON.. will the pump still be on?
Sir I made this circuit but there is some problem in my circuit. When tank is full means all 3 sensor get connected together then my relay should be in off state but my relay malfunction sometimes it gets on some time it gets off. Can you please suggest to me what could be the problem.
I made this using a board from PCBWay, tested it today with a lightbulb, absolutely perfect function. Thank you!
Hello sir... Is this circuit working perfectly till now...
@@varakrishna1016 It worked great for several months, no problems at all, but I did swap that out to another circuit.
@@LeeThayer-nn5yeDid this work when lights cut off and come back on?
Suppose the pump was ON (that is the water level is below the top sensor wire) and then electricity cut off and come back on again.. will the pump still be on?
@@chewthiya I did not test that aspect, but in design, the sensors are still making the same readings.
👌👌🌹GOOD TICHING KARTE HO AP THANKS 👌🌹💖😂😆
I made and working perfectly fine... If you add 1 more function for municipal water supply and submersible auto on off function then this will work all conditions..
Hatsoff brother..
Hello sir... Did u make this circuit
Электродов не хватит на долго уже проверено! Лучше поплавковый герконовый .
Can I keep it on,all the time?will it effect the relay?Please advise me. Thank you.
In this circuit, When the power cut off and turn on ,it will turn on automatically while tank is not in below level
Yes...
How to contact you
@TechStudyCell Any solution for this?
This will lead to flooding in case of a power outage
Can it drive the 2 HP motor without the use of contactor?
Can you replace the starter with just another switch?
Parabéns pelo
Canal. Como faço para que a Alexa identifique ou mude um tasmota como um “plug” e não somente Luz.?
Which app ur using to make pcb layout bro
PDF is not opening
I need this circuit diagram.
Detail of Connection of starter with pcb and which type orf stater is used
Sir 0-12v, 1Amp trasformar use kar sakte hai
Sir suggest additional connection for multiple overhead tanks and underground tank + government water supply
Very good project, but please help me solve one problem, why my relay keeps switching on and off rapidly after the tank is full?Please help me ,thank you.
It may occur if there is any loose connection or the wire overlap on each other.
Thank you very much.
Hello?
I'm asking you a question.
What kind of tool do you use to make the paper patterns?
Photoshop
Bhai mujhe ye buy karni h kaise karon full circuit
What is the thickness of the plastic sheet? Kindly tell me..
How to add one more sensor to the overhead tank? This sensor should cut off the power to the pump once it gets in contact with water.
This is so that if the pump switches on after power failure, the tank still won't overflow.
Hope someone comes up with this
If we use groundwater instead of underground tank then what will we do?
Hello, please reply, I have a question:
Will this work when electricity cuts off and on?
Suppose, The pump was ON, that means, the water level was below TOP and pump was ON
then electricity cut OFF and later came ON.. will the pump still be on?
video is helpful Dry Run cut off motor Please help sir
Yes, Those two probes shown in the underground tank, put them in a T - Pipe and then you are ready to go...
Sir I made this circuit but there is some problem in my circuit. When tank is full means all 3 sensor get connected together then my relay should be in off state but my relay malfunction sometimes it gets on some time it gets off. Can you please suggest to me what could be the problem.
My circuit also getting same problem bro... Did you find the solution
Link share kiya kijiye project ki , taki easily mil jaye
Where can I get the diagram sir? Please help
During the video or visit article. Link in description
Bro how to make zero PCB layout please upload a video about this
Can you make wireless float for top tank iot based
Can you make wireless float control for top water tank iot based
Can you please send the BOM and pick and place files for SMT services. Will be grateful
I have 1.5 hp submersible motor which i have No and Nc switch i want to make this two way , with wifi, Bluetooth and switch can you make it please!
Please make a door lock use OLED display, ESP 32,4x4 key , RFID model
Required for submersible pump
It is for submersible pump
No it's not working for submersible pump
bro can u give me the gerber file and schematic
download from easyelectronicsproject.com/mini-projects/automatic-pump-controller-using-555-ic/
I dont no,, good blazzz,,,😅