How Do I Get Shocked? Why Am I Getting Shocked? It's Simple.

แชร์
ฝัง
  • เผยแพร่เมื่อ 26 ม.ค. 2025

ความคิดเห็น • 397

  • @Matt10Lawrence
    @Matt10Lawrence 2 ปีที่แล้ว +162

    I've been stuck to a metal equipment cart because my muscles tensed up closing my hands. Up one arm,across my chest, out the other arm. Unable to let go. Couldn't move. Couldn't speak. Couldn't breathe. I could only make low gurgling noises. The most helpless feeling in the world. It was maybe 30-45 seconds before someone saw me. He looked at me like what in the f are you doing before it finally clicked what was happening. He hit the E-Stop button on the wall dropping power to the whole shop. I took the deepest most wonderful breath of my life when I finally fell off it. Yes, that hurt. I have a very intimate appreciation for GFCI protection after that. And a good healthy fear and respect for never letting that happen again. And that was only 120v!

    • @justdrive5327
      @justdrive5327 2 ปีที่แล้ว

      You're going to be a very seeable ghost when you die. You have alot of energy inside you. All I get from 120 is a tickle

    • @ryans6423
      @ryans6423 2 ปีที่แล้ว +26

      Me sitting here not expecting this to be a 120V story…. 😰. Note taken

    • @Hatim.13
      @Hatim.13 2 ปีที่แล้ว +15

      @@ryans6423 Most electrocutions happen with 120V, crazy when you think about it.

    • @jsb7546
      @jsb7546 ปีที่แล้ว +5

      @@Hatim.13 it's a low enough voltage some take it for granted and don't realize other factors can make even a 120 volt shock way worse than usual it's also the most common voltage.

    • @Dave-nm3xc
      @Dave-nm3xc ปีที่แล้ว +1

      Damn. You're lucky to be alive. Glad you lived to tell the story!

  • @normILL
    @normILL 2 ปีที่แล้ว +26

    I was working in an basement demoing out old K&T that another electrician told me they had turned the breaker for off. I got to a bathroom plug with one of those old small metal boxes. Same circuit as the lights in that area. I started trying to push the wires out the back so I could pull the box out, but when I pushed the second wire the first one would keep bumping back inside. I had the smart idea to use both my thumbs to push them simultaneously, and that's when I discovered the circuit was still live, and I was just getting lucky with the light outlets up to that point.
    Needless to say I then slammed every breaker off and went to find that other electrician.

  • @justin_other_kayaker
    @justin_other_kayaker 2 ปีที่แล้ว +62

    High school industrial engineering teacher here. Love your stuff man, please keep it coming. Anything you offer is appreciated.

    • @c50truck
      @c50truck 2 ปีที่แล้ว +13

      My high school electric shop teacher, (decades ago), had a saying over the chalk board. "Electricity is always searching for ground, never let it find it through you". That stayed with me, and kept me safe for decades!

  • @paaao
    @paaao 2 ปีที่แล้ว +49

    You cannot be grounded at all if you want to touch single hot wires without getting bit. Most shoes will have a low enough resistance to allow 120V and up to pass through the body to earth. Make sure you are on a fiberglass ladder, or have electrical rated mats, etc, if you plan to touch anything hot.

    • @KF-zl5io
      @KF-zl5io 2 ปีที่แล้ว +16

      Not really....Ill grab a hot wire here and there with my ticker or my meter in the other hand to freak the new guys out. Never been bit from standing with boots. But I'm sure after typing this it will happen next time I do it...gotta love electrical

    • @CharkG73
      @CharkG73 2 ปีที่แล้ว

      True story lol. The guy that taught me this, let's just say I made sure he did it first before I trusted him to try it myself. Better make sure your boots don't have holes in them hahA

    • @CharkG73
      @CharkG73 2 ปีที่แล้ว +9

      You do have to be careful though because even though you won't feel anything if you're ungrounded touching 120, higher voltages can cause problems simply from the potential difference of your body and the wire when they touch. Those guys who sit on top of transmission lines coming off a helicopter have a wand that helps them equalize potential

    • @Bapuji42
      @Bapuji42 2 ปีที่แล้ว +2

      I mean, unless you have ASTM electric hazard rated boots, safe up to 18kV. Which everyone ignores because they pick their boots by looks, and which "top notch" brands like Nick's and White's don't even offer.

    • @blakek1043
      @blakek1043 2 ปีที่แล้ว +1

      I use to test power by using 1 hand 2 fingers, but I've stopped doing that as I probably shouldnt...shouldn't.... lol good ol days, when you start to care about your health.

  • @ramiro9172
    @ramiro9172 2 ปีที่แล้ว +10

    I've been doing electrical work for 17 years And you Have a really good way to teach t in all your videos so congratulations brother keep going

  • @mattnone1440
    @mattnone1440 2 ปีที่แล้ว +9

    I used to do commercial/ industrial electrical work. I was retrofitting light fixtures in a facility that was still running, so we worked hot circuits. I had been standing on a warehouse rack for access to a group of lights and had been working without issue. Always start by clipping the hot and capping it off then work the rest of the conductors. At one point the ceiling lowered so I sat down on the rack to continue work, without issue on the first fixture. When working the 2nd fixture, I mistakenly allowed my finger to contact the metal of my cutters when clipping the hot. I immediately verified that the racking system was properly grounded and the protection my safety boots offered did not extend to my a$$. He is right about the 2 point connection.

    • @pogtuber5146
      @pogtuber5146 หลายเดือนก่อน

      So you're saying your ass is your path of least resistance

  • @TR4Ajim
    @TR4Ajim 2 ปีที่แล้ว +15

    I learned a lesson several years ago. I had to go into an outlet box to make some changes. When working by myself, I plug in an old radio, so I can hear the radio go off when I turn off the right breaker. I went back to the outlet, unplugged the radio, and put the multimeter into the upper plug (THE SAME PLUG THAT THE RADIO WAS IN), verifying no power. I pulled out the outlet, touched the screw on the lower plug and promptly blew off the tip if the screwdriver!
    Turned out the outlet had been split, and the lower plug was on a different (live) circuit!!
    Lesson learned.

  • @raymond3722
    @raymond3722 2 ปีที่แล้ว +8

    You are so eloquent in demonstrating to us, you are a true Master the way you explained yourself theoretically.

  • @jamesalbert4520
    @jamesalbert4520 2 ปีที่แล้ว +37

    Also, always confirm it on your own that the power is off. Dont rely on "buddy" to make sure its off. "Hey buddy did you turn the circuit off?" Make sure its off. Dont count on Buddy

    • @farrieterrisky
      @farrieterrisky 2 ปีที่แล้ว +5

      Buddy is never your buddy! Hell even when I turn off power I still check, because I'd rather coffee over a shock to wake me up!

    • @bertblankenstein3738
      @bertblankenstein3738 2 ปีที่แล้ว +2

      Verify the power is actually removed also. Don't rely on the wiring to be correct, or the labeling to be correct.

    • @brandonreyes5567
      @brandonreyes5567 ปีที่แล้ว +1

      1000 %

    • @eisenmantom
      @eisenmantom 4 หลายเดือนก่อน

      Even if Buddy is competent, you don’t know for sure if Buddy and you are thinking of the same circuit. Think how mny times you’ve said something like “move it a little to the left" and had the person move it to the right. The other person has a different point of view (they are facing you) or they just momentarily forget which is left and right.

  • @freddywohlfahrt8830
    @freddywohlfahrt8830 ปีที่แล้ว +2

    Bro I got shocked barefoot on a patio today and you made me feel a lot better about it and gave me good understanding of electricity. Thank you.

    • @glasshalffull2930
      @glasshalffull2930 10 หลายเดือนก่อน

      Can you describe in detail what happened please.

  • @ronlovell5374
    @ronlovell5374 2 ปีที่แล้ว +29

    AC capacitors will bite you good too, even if source is shut off, it can still back feed to it. Got me a few times!

    • @jakesully5402
      @jakesully5402 2 ปีที่แล้ว +1

      Yup. Same here. I’ve felt the love of a capacitor too…

    • @goaliedude32
      @goaliedude32 ปีที่แล้ว +1

      A young man was killed working on HVAC equipment because of the capacitors still charged. I remember hearing the news story on my way in to work on the news radio. Terribly tragic loss of life.

  • @Bestnightcoreofalltime
    @Bestnightcoreofalltime 2 ปีที่แล้ว +4

    I got shocked once in my life in Germany with 400V and after that it never happened again.
    Have my Duspol beha ampere at my side every time and mostly shut down the breaker of the circuit I work on.
    It is not worth it to risk your life.

  • @WestonP22
    @WestonP22 2 ปีที่แล้ว +50

    My grandfather used to casually work on hot receptacles like it was nothing. Always freaked me out that he didn’t turn off the breaker. Turns out he was well educated on this and saw it as no big deal, as he first started doing hot work while being shot at in the Korean War.

    • @mesohunt704
      @mesohunt704 2 ปีที่แล้ว +7

      I work on hot receptacles a decent bit. I wouldn’t say “often” but it’s not rare. Sometimes for XYZ reason a circuit cannot be turned off at the time. Of course it’s dangerous but if you know what you’re doing and take your time moving very precise it’s usually fine. I would never recommend anyone do it and honestly it’s stupid that I do it. The older I get the more I find myself not making decisions like that.

  • @djromaxtions8328
    @djromaxtions8328 2 ปีที่แล้ว +7

    bro I like how u incorporate the graphics and small cartoon skits in ur lessons its actuaally interesting lol this channel rocks

    • @maddyolive5985
      @maddyolive5985 2 ปีที่แล้ว +1

      It helps me understand better

  • @Silvermeow
    @Silvermeow 2 ปีที่แล้ว +6

    So when you ARE touching only the hot... do you know if the current stops in your body? Or if its stopping at the end of the wire?
    Furthering this question, if you don't get shocked when the electricity is stopping within you but only once its passing through you? Why? Because you have allowed a path? So less resistance and increase of current?

    • @tedlahm5740
      @tedlahm5740 2 ปีที่แล้ว

      absolutely to part 2 of the question.

    • @bertblankenstein3738
      @bertblankenstein3738 2 ปีที่แล้ว

      If you only touch one wire, and the rest of your body is insulated, dry, etc, there is no current flow through your body (the circuit is not complete). It is the current flowing through your body that'll hurt you. Think of a bird sitting on an electrical line.

  • @CharkG73
    @CharkG73 2 ปีที่แล้ว +4

    I was trained to always treat it like it's hot. Well one day we were tracing out a couple circuits after a demo to leave on for temp power. J man said to find it and come back to the electrical room so he can shut it off while I make it up. I went back and said I found it, then went out and made up two plug feeds in an old box. Came back and said, "ok it's finished, you can flip the breaker back on.". To my surprise, he showed me the breaker still turned on. I had never told him to flip the breaker off, but made the mistake of assuming that by walking into the panel room and saying I found it, he would understand to flip it off. I was quite surprised that even though it was through a mistake, I had just made up two hot joints and their neutrals without even realizing it. If I didn't have the habit drilled in to me about treating everything like it's hot, I could have easily caused an uh-oh there by cutting the whole cluster of wires at once, grounding myself to the ceiling grid, letting two stripped wires touch, etc. Still didn't tick test it like I should have, and learned a lesson about assuming things

  • @Nicholas-xz6dp
    @Nicholas-xz6dp 2 ปีที่แล้ว +3

    Bro... I fucking LOVE you.... AND THAT is why I am telling you... you are one of the main reasons I have an amazing career now.. but bro, its "ad nauseum".
    This is not the first time so that is why I am telling you now lol. Love you mucho thank you for all your hard work.

  • @charlesmcadory8286
    @charlesmcadory8286 2 ปีที่แล้ว +3

    I do many residential now and when you kill the power you tend to do a neater job.

  • @Rickrolled88
    @Rickrolled88 2 ปีที่แล้ว +11

    I've been hit with 120V with a 15A circuit breaker, 240V from source, and 480V with a 5A circuit breaker. Luckily nothing substantial, but the 120V was the most dramatic. The 120V was totally unexpected. I thought I was doing it safely. The 240V, and 480V were just me putting a finger where it shouldn't have been. The closest I've been to getting hit really hard though was with a 480V distribution panel. We were demobilizing a couple of units and had two different panels feeding into our different units from the customer from two different panels. The customer turned off one of them panels and left the other one on. When we came back to unhook the power from our units I took off the safety shield from our breaker panel and was about to go in and disconnect the main power, but something told me(inches away) from getting shocked, electrocuted, killed, to stop and check the voltage. Turns out it was still live. I am so lucky that didn't happen otherwise I either would be a crispy critter, or dead.

    • @deang5622
      @deang5622 ปีที่แล้ว

      If you were touching 120 volt either deliberately or accidentally, then you were not doing it safely, you did something wrong, unless you are a qualified lineman and are using techniques to work on live lines

    • @leighz1962
      @leighz1962 ปีที่แล้ว

      240 has more resistance so "safer" in that regard. Costs more to run it.

    • @Rickrolled88
      @Rickrolled88 ปีที่แล้ว

      @@leighz1962 Got Lucky with a finger brush against a live terminal. (stupid mistake) but a learning experience.

    • @Rickrolled88
      @Rickrolled88 ปีที่แล้ว

      It's all about how you get shocked and where. The 240V and 480V shocks where a brush against a live wire or post. The 120V shock was more dramatic and could have been bad, but really a lot of luck was involved. The worst part was I felt I was doing the line work safely.
      @@mclaurinisGODsSon2

  • @mikegrimaldi5844
    @mikegrimaldi5844 2 ปีที่แล้ว +8

    Careful with white conductors that are generally neutral and circuit is off and thinking it is safe to work on. If whites are all tied together in a jbox and from DIFFERENT circuits, there’s a chance that that supposed neutral is live (from another circuit). I’m a handyman and couldn’t figure out why I was getting power in the connection box when circuit was off. Your comments about hot neutrals are welcome as I am still learning about safety.
    I learned to use voltmeter instead odd those on/off indicators when testing for voltage on what I am working on. Your teachings are very helpful-and potentially (no pun intended) lifesaving!

    • @jameslke1241
      @jameslke1241 24 วันที่ผ่านมา

      Very true!

  • @domainmojo2162
    @domainmojo2162 4 หลายเดือนก่อน +1

    I've never been electrocuted apart from little DC shocks and staic, BUT I have never and will never ask someone- even if it is my wife or child, or a buddy to disconnect the power. I will also NEVER want to leave the power source insecure and unguared. Never, ever.
    If I ever have to work on electricity, I will disconnect the power and prevent anyone- by physically securing the area, from swithcing the power back on! I have one of those - "anything will happen" mindsets - careful to the point of being fearful, so anything will happen.
    Anyway, this is life-saving information. You don't know how many lives you've saved across the world, man. Neither do I, but it has to be many. 😀
    I ALWAYS had problems understanding electrocution, I mean it's been years that I tried to see if I can finally understand it, but "Grounding" got in the way. It always does. 😀
    I've realized today (finally- it only took .... years! ) that I'm getting Grounding and general electrocution confused and so I searched and searched and refined my search and finally landed on your video - cause it's something I REALLY want to understand.
    Grounding and short-circuits due to electrical faults/failure is DIFFERENT to general electrocution. I think that is what confuses people, but they don't realize it.
    Thank you!

  • @workingshlub8861
    @workingshlub8861 2 ปีที่แล้ว +1

    great point about tick tester....i work with a guy that always just relied in tick tester and and i got him in the habit of using the meter also....know your voltage never assume anything.

  • @williambratton8900
    @williambratton8900 ปีที่แล้ว +1

    After years of replacing receptacles and switches without turning off the breaker I finally learned my lesson. I was kneeling on a dry wooden floor, after telling myself it was no need to shut off the breaker to wire the plug since I had done this 10s of times with not getting more then a finger buzz. I picked up the romex to open the jacket at the cut off end. As soon as I picked up the romex the end hit me in the middle of my chest giving me the worst shock of my life. It did not knock me down but it hurt like hell. Needless to say I got up and turned off that circuit’s breaker. I will never work with live wire again because it is unpredictable.

  • @allenft8396
    @allenft8396 2 ปีที่แล้ว +13

    Love your videos and animations! Can you do a quick video on the correct way to pool bond including the deck and surroundings. ?

  • @thetruthexperiment
    @thetruthexperiment 9 หลายเดือนก่อน

    I really appreciate this because not knowing and being afraid is liable to cause a lot more accidents than when you understand what’s going on. Kids are told not go near electricity and are too afraid as adults to jump a car. Sure, working with live wires a person could get careless but every kid and certainly every adult should understand how and why shocks occur and how and they don’t. Carelessness can cause accidents but confidence (not over confidence when you’re actually ignorant) is invaluable. Most people live in their house terrified of the wires that they use all day long and never actually know what the dangers are. Our modern safety culture is a culture of accidents waiting to happen. There are probably houses that could have been saved from fire if the occupants didn’t have to call an electrician to fix a precarious looking mess left by a braver but foolish previous occupant or some other situation with a simple solution.

  • @igoro9898
    @igoro9898 2 ปีที่แล้ว +9

    Great video! We really should start teaching apprentices with that guide and understanding how it actually works. Be safe everyone

    • @mtoohill
      @mtoohill ปีที่แล้ว

      Should be taught senior year of HS.

  • @Mr122397
    @Mr122397 2 ปีที่แล้ว +1

    Not long ago, I was changing out an electrical panel and our local utility company didn’t have any SOP requiring them to disconnect the service lateral down at the street level. So the utility worker taped up the hots and when I put on the new panel I got a nice arc burn to the face. That was not fun at all but it seemed like one of the hots wasn’t taped up correctly and when it came in contact with the lugs on the utility side it completed the circuit with the service neutral that wasn’t taped up. Needless to say, I double tape it now after they leave!

  • @D_Spear
    @D_Spear 2 ปีที่แล้ว +2

    I don’t suggest it but I like showing apprentices a hot wire with my tick tester while on a fiberglass ladder, then proceeding to touch it bare handed. It always blows their mind

    • @modernbassheads5051
      @modernbassheads5051 2 ปีที่แล้ว +1

      You just blew my mind and I’m a 3rd year apprentice I’ve never heard of this phenomenon I always thought the potential is very different even if you’re not grounded you’d feel something. Can you make a video showing how this is possible ?

    • @D_Spear
      @D_Spear 2 ปีที่แล้ว

      @@modernbassheads5051 it doesn’t have anywhere to go if you aren’t grounded. You won’t feel a thing.

  • @claytonfite3197
    @claytonfite3197 2 ปีที่แล้ว +2

    Respect the power be aware of all conditions around you. Eliminate the risks .Great video

  • @tonyt160
    @tonyt160 2 ปีที่แล้ว +2

    Great videos. I mostly connect and run wire into hot PPC- load centers.. The Cell Carrier Companies only allow us power shut down from 11pm to 5am. So we build during the day and do the cut overs at night.

  • @bayrealist4176
    @bayrealist4176 2 ปีที่แล้ว +9

    Neutral is supposed to be a non current carrying conductor. I've been hit from neutral to ground when circuit was OFF. Just because you turn breaker off it does NOT mean you are safe to touch wires. NEVER trust your co workers..TRUST ONLY YOURSELF. First time I ever got shocked was due to a licensed journeyman installing the switch upside down..I " turned off" switch and went straight to replacing ballast without checking with voltage tester. Was definitely a learning lesson! Save your own life!

    • @ApekHeilon
      @ApekHeilon 8 หลายเดือนก่อน

      Yes , so many unlicensed or unqualified electricians will just simply folowing color to color for connections. They even don't realized that was wrong connections too. Hot to neutral and neutral to Hot... OMG why this will happened................

  • @bradmironik6137
    @bradmironik6137 2 ปีที่แล้ว +3

    Good topic. I have been shocked a few times but the strangest situation was during a gas piping installation on a outdoor furnace. It was wet outside and as I was getting zapped trying to assemble pieces. I had about 15v from piping to ground on the meter. I couldn't figure out what was the cause but quit and came back on a dry day. Maybe someone might have some ideas. This was several years ago and I won't forget it.

    • @justinphoenix21
      @justinphoenix21 2 ปีที่แล้ว

      Is possible that the metal piping had become energized through some fault in the wiring or grounding of the furnace. On the other hand, if you were working from the utility side towards the furnace, it could be that there was a ground fault at the furnace which energize the ground, and your metal pipe was acting as a lower resistance conductor to complete the ground path back to the transformer. Then of course you complete the circuit by touching both the ground and the pipe. I'm sort of guessing this second scenario might have been what you experienced since that could be quite puzzling. Did you report this so an electrician could look into it?

  • @RonSch123
    @RonSch123 2 ปีที่แล้ว +5

    I would add, unplug washer/dryer if working on the laundry circuit right behind the units. Same with working on kitchen counter receptacles with your knee potentially touching a properly grounded dishwasher. And DON'T leave your cell phone in a pocket. Electricians have really fast reactions to the "vibrate feel" of a shock and you can pull your hand from a good position to a bad one in a panel for example. Leave your cell phones on a nearby surface. Ask me how I know LOL!

    • @WilliamMcCormickJr
      @WilliamMcCormickJr 2 ปีที่แล้ว +1

      If you lean against a Formica countertop, you can get a nice buzz through your pants while touching a live wire. I put a furniture pad or blanket on the countertop before working on them. Also, if you kneel, there is enough surface area to create a large enough capacitor to shock you. If you are holding a live wire. Laying on the ground will also allow you to be shocked if you touch a live wire. The large surface area creates a very large capacitor.

  • @alphasaiyan5760
    @alphasaiyan5760 2 ปีที่แล้ว +19

    277 V was the worst shock that I’ve ever experienced. I was on a 12 ft ladder up above a drop ceiling. Opened a junction box the disconnect some lighting and when I took the cover off the box the wires came out from under a wire nut and I touched them by accident. Got hit bad and fell backwards off the ladder through the drop ceiling. Hurt like a bitch lol. I was lucky that I didn’t get injured. The second worst shock I ever got I was changing out a service and the guy I was working with said it was disconnected. And like a dumbass I didn’t double check with my meter before I stuck the Allen wrench in the lug and BAM got hit bad. I felt my heart skip a couple beats and then I was sweating really bad for the rest of the day and felt real nauseous for a couple days. Then after about 3 days I felt better. This happened when I was a younger electrician and made me learn real quick to be more careful and always ALWAYS double check to make sure about things before just trusting someone else’s word. Now I’m fully confident in any situation because I know the steps and precautions to take. 👍

    • @NerveFlux
      @NerveFlux 2 ปีที่แล้ว +2

      Yeah. 277v 30a up the leg out the arm ruined my body. I still wake up seeing flashes on some nights.

    • @maxpilling7796
      @maxpilling7796 5 หลายเดือนก่อน

      Watching this video after getting shocked from 277 I was on a ladder and just jumped off and rolled bc I was gripping the mc that got energized. Now my finger will look like a bratwurst for a few weeks but it is a good wake up call

    • @alphasaiyan5760
      @alphasaiyan5760 5 หลายเดือนก่อน +1

      @@maxpilling7796 damn man yeah I saw a guys hand explode from the inside out from 277 once. He touched the hot wire with his index finger and the neutral with his pinky and it blew a big chunk of meat out of his hand. He was screaming in pain and the wound was cauterized from the inside out too. He almost lost his hand from that. It was bad.

  • @jllemin4
    @jllemin4 2 ปีที่แล้ว +4

    Commenting before watching as a student: You get shocked by hot HV anything, you die from disobeying the one hand rule, and you get shocked by giving a live circuit an overall shorter branch to discharge though(You). In simple terms, HV will bite you, keep one hand in your pocket around anything live, and touch with your eyes before you feel with your hands.
    Things I'm reminded of while watching: Always wire the ground first, then the neutral, then the hot, and never wire things while they are hot if you can avoid it. PPE is a given.
    My takeaway: Work in your training and specialty, if you are asked to do something you have not been trained for fall on the OSHA side of things and try to get training for it. Use every resource to prioritize safety above all, this is why we make lots of money: To spend it on PPE and contingencies. The temporary debt, education time, NEC book time, and perfectionism are ALL worth it and what makes an excellent electrician in the end. Kneeling is for suckers, squatting is the way to go. In the end electricity is a jetstream of energy similar to a water jet that moves through conductive material, if you become that conductive material it will vaporize your cells into a nice dry carbon conductor in an instant: don't let it happen.

    • @tukos7370
      @tukos7370 18 วันที่ผ่านมา +2

      that is a huge lesson, thank you

  • @glenmartin2437
    @glenmartin2437 8 หลายเดือนก่อน

    Thank you. Viewed your video before.
    I have worked on electrical wiring since I was about seven years old, starting with replacing wire fuses, then repairing broken and loose wiring. I had watched electricians wire new homes before I entered grade K in Virginia. I still stand by as a safety man when certified electricians work on our home.
    Over 400 volts AC, no contact is necessary for a shock or electrocution. Just get into the corona about a wire or metal surface and zap!
    I use my meter, not my fingers. After a while, fingers quit sensing electric shocks and those little shocks can damage your sense of balance.
    Mike Holt talks about these long term consequences and uses the term sequelae.
    Thanks, again.

  • @samuelcrossland1101
    @samuelcrossland1101 2 ปีที่แล้ว +8

    I'm glad you spoke on neutral current.
    I had a site where workers were saying they were getting shocked stepping off of an aluminum scaffold onto a wooden deck.
    Odd?
    The entire scaffold was energized by neutral current and had potential between the detached house and scaffold. I used a ground clamp on the scaffold and connected it to the ground wire from a flood light. No sparks or anything, voltage between the two structures whent from 115 to 0 immediately.

    • @w1swh1
      @w1swh1 2 ปีที่แล้ว +1

      That is quite scary Samuel. Will bear that in mind. I am always a little nervous when I switch on a table lamp where the switch is part of the light bulb holder. Should be perfectly safe....in theory!😨

    • @samuelcrossland1101
      @samuelcrossland1101 2 ปีที่แล้ว

      @@w1swh1 It's safe, lamps don't have a connection to ground normally. The plugs are polarized ( you can't plug it in wrong because one side is physically bigger than the other) [ Or it is double insulated meaning there is no physical connection between electrical parts and the body of a piece of equipment.]

    • @w1swh1
      @w1swh1 2 ปีที่แล้ว

      @@samuelcrossland1101 Thanks Samuel, makes sense.

  • @bertblankenstein3738
    @bertblankenstein3738 2 ปีที่แล้ว +2

    Here is another good one: don't rely on flipping the breaker off. It has happened where the hot has made a loop, connecting to two breakers (terrible I know). Flip the breaker and verify the power is off. Mislabeled breakers, and kitchen plugs where there are two circuits to one plug (Hopefully those breakers are ganged up).

    • @submittedbymail
      @submittedbymail 2 ปีที่แล้ว

      Sounds like you learned the hard way.

  • @okaro6595
    @okaro6595 2 ปีที่แล้ว +4

    In the series if there is no other load you will not get shocked as the circuit is not closed. The more load there is the less impedance there is. And in series you can get just as well shocked by the neutral.

    • @tedlahm5740
      @tedlahm5740 2 ปีที่แล้ว +1

      How often do we see AC circuits wired in series as opposed to parallel?

  • @Sparky-ww5re
    @Sparky-ww5re 2 ปีที่แล้ว +3

    Having worked in both residential and commercial, my multimeter is always within arms reach, right along side my screw drivers (electrical rated) and lineman pliers. Never trust colors. in residential it's common to run a 12/2 NM to a NEMA 6-20R, for a larger window air conditioner. the white is supposed to be re-identified as hot, but I've seen many instances this isn't done. In commercial working in a three phase panel, not only do I need to check whether the power is shut off and locked out, I also need to know, if I'm dealing with a 120/208Y, 277/480Y, or a 120/240V Delta with high leg. The high leg on a delta is 208V to ground and is supposed to be marked orange, and it's very easy to mistakenly place a single pole breaker on this high leg and you just wiped out thousands of dollars of equipment because you thought you were getting 120 volts.

    • @shawnwaterssw
      @shawnwaterssw 2 ปีที่แล้ว +2

      Keep my fluke 101 with me at all times.

  • @MrGatlin98
    @MrGatlin98 2 ปีที่แล้ว +3

    I've been wondering this question for years. I understand how to be safe but I don't know exactly how it can go bad.

    • @deang5622
      @deang5622 ปีที่แล้ว

      It goes bad when a) you touch something whilst energised which you should not do
      b) you didn't turn the power off and lock it off so no one can turn it on.
      It is nearly always the result of incompetence, unless you are a qualified lineman and need to work on energised circuits.

  • @englishgator2629
    @englishgator2629 ปีที่แล้ว +1

    I’ve started training as an RV technician and I am doing well in most areas but I still just can’t wrap my head around electrical circuits. Im learning little by little and this video helps but I still just struggle to understand it at all😞

  • @gabrielesposito2735
    @gabrielesposito2735 3 หลายเดือนก่อน

    Great video Electrician U! 🔥 Thank you! 💯

  • @alexbemis2656
    @alexbemis2656 2 ปีที่แล้ว +1

    Great content!! I really enjoyed this one Dustin!

  • @joshcowart2446
    @joshcowart2446 2 ปีที่แล้ว +1

    We used to go to Mexico. Cuidad Acuña to be exact. It’s across from del rio TX. One of the bars called up and downs had an electric chair. You sit in this chair and grab a pole with each hand. They turn up a dial. If you get to 100 you get to sign the wall. I don’t know what 100 meant if anything . In hindsight that’s a stupid goal because it’s not too hard to do so after a certain time period they just paint over all the signatures. I don’t know what the voltages we were experiencing were. Your muscles would tense like crazy. I’m guessing it was fairly low because I’ve been hit by 110 a handful of times and it hurt more than the chair. Regardless it probably wasn’t the smartest thing I ever did.

  • @dannywitz
    @dannywitz 2 ปีที่แล้ว +5

    I’m surprised you haven’t had the experience of “two points” being a hand and your feet. Just brush your fingers with a live conductor (including a neutral with current flow) you’ll feel it!!!
    In practice it seems like you touched one item (one touch point) and may have forgotten your feet complete the circuit

  • @beanieweenie9543
    @beanieweenie9543 2 ปีที่แล้ว +2

    I will never forget the day I got shocked for as long as I live. It was some scary shit I literally thought my heart was going to explode.

  • @snuggie12
    @snuggie12 2 ปีที่แล้ว

    Not sure if you've ever covered this, but I live in a 100 year old house and when I watch your stuff the wires in the boxes are so clean (I mean organized-clean, not the opposite of dirty,) and what not. For example, I have boxes that are an inch and half back from the wall. I'm just a DIY'er so I don't know if this is normal but one thing I see is that there feels like there's way more pig tales and wires in general in the boxes.
    Wondering if you run into this kind of stuff and could comment on how designing a room's wiring has changed, things you might encounter and possibly ways to improve them or just understand the situation better.

  • @frankgonzalez24
    @frankgonzalez24 2 ปีที่แล้ว +2

    I have to be extra careful when it comes to electricity because I had a cardiac arrest and now have an implanted cardiac defribillator (icd). I'm a auto mechanic and have done home electrical repairs. I've been shocked by the ICD, the engine ignition coil and home voltage (not at the same time) and none of them feel good. Getting an external shock can damage my ICD or cause it to shut off. If one has some type of electrical device implanted in them, be extra careful when working with electricity because the affects of getting shocked and how it will affect the medical device implanted in the person is unknown until that person is shocked by the external source.

    • @modernbassheads5051
      @modernbassheads5051 2 ปีที่แล้ว +1

      If I was you I’d look into putting money aside for insulated gloves and leathers to go on top of, if not switch jobs buddy a desk job might be worth it for peace of mind not trying to be funny

    • @frankgonzalez24
      @frankgonzalez24 2 ปีที่แล้ว +1

      @@modernbassheads5051 working on cars with insolated gloves can be difficult especially with today's engine compartments that are extremely tight. The home repairs I do are things like replacing outlets, switches, installing lights, ceiling fans and other similar type fixtures. I'm not rewiring a house. When doing home electrical repairs, I shut off the circuit and make sure the circuit is dead with a the multimeter. I'm a hands on, technical type person which is why I work on cars and do simple type home electrical repairs and am not a "desk" person.

  • @hliz8818
    @hliz8818 2 ปีที่แล้ว +1

    What happens if a service wire accidently touches the panel..?? Always been curious about that.. like in a swap out.. where some electricians don't take out a meter..?

  • @FSAUDIOGUY
    @FSAUDIOGUY ปีที่แล้ว

    Had to do a breaker change today for a customer. Main breaker off first thing, box was very crowded. I have no interest in tempting fate when it comes to a service panel or a hot circuit. Been bit a few times by 120v, lessons learned. Your heart runs on electricity, don't introduce more juice into your body if you can avoid it. As always thank you for the content, stay well EU.

  • @RichardNickels-ot6iq
    @RichardNickels-ot6iq 8 หลายเดือนก่อน +1

    This Is Awesome Program 😄👏

  • @andrewfischer8564
    @andrewfischer8564 2 ปีที่แล้ว +1

    i didnt do it to often but i worked with old timers who would check 110 lines with their fore finger and thumb

  • @jllemin4
    @jllemin4 2 ปีที่แล้ว +3

    Hey ElU, dunno if you have a video covering the topic of how to price yourself as an apprentice getting working hours, but I'd like to hear your opinions on how to negotiate those sort of things as someone who is green but also good at the job. Thanks for the content you put out, its very helpful

    • @FCES_Electrical_Sol
      @FCES_Electrical_Sol 2 ปีที่แล้ว +1

      He actually does, you should check it out.

    • @jllemin4
      @jllemin4 2 ปีที่แล้ว +1

      @@FCES_Electrical_Sol If only you could link it in the comments. Could you tell me what it's titled?

  • @PERTEKofficial
    @PERTEKofficial ปีที่แล้ว

    Someone on my jobsite who isn’t an electrician decided to flip a breaker on and one of my coworkers got shocked. It became the topic of the safety meeting for a few weeks

  • @SierraGolfFoxtrot
    @SierraGolfFoxtrot 2 ปีที่แล้ว +1

    Depending on the the square footage of the house how long should it take you to rough a house, how long should it take you to trim a house??

    • @mannynemer5316
      @mannynemer5316 2 ปีที่แล้ว

      However long it takes. As long as ya bust ur ass

  • @joecliffordson
    @joecliffordson ปีที่แล้ว +1

    Question for the pros. Recently had a tester registering hot ground revers on a home run with no other load. Upon turning off the breaker the tester lights stayed on. Working my way down the breakers I found the circuit leaking to ground on that sub panel. The second box I opened had a ground wire screwed onto a traveler terminal of a three way. The traveler (hot)wire was in the push in on that terminal. Presumably someone mistook that terminal for a ground screw. It had been there for years. Only showing up on a tester when the three way was in that configuration. Now for the question. Why did this not break out or burn off?

    • @ethanavery9748
      @ethanavery9748 ปีที่แล้ว +1

      I'm just a second year apprentice, but it may be possible that the electrical wiring was not properly grounded. If it was, then in the proper 3-way configuration it would have a low resistance to ground and trip the breaker as it would exceed the amperage on the circuit before it started burning anything. Also it's possible the lights to that 3-way would be very dim (in the proper configuration) as it was in parallel with the ground but a much higher resistance. The homeowner would realize that there was only 1 combination of up/down that would allow the lights to turn on therefore rarely even shorting the circuit out.

    • @joecliffordson
      @joecliffordson ปีที่แล้ว +1

      @@ethanavery9748 your response reminded me I did not post what I found. The 200 amp panel for this house was a sub panel coming from the farmyard pole. The electrician that wired the sub put in put the required insulated direct ground wire to the pole box from the sub panel. He however connected it to the common lug instead of the ground lug in the sub panel(incorrect) and on the main panel connected it to the common lug(correct). Problem being in a sub panel the ground and common are not bonded together. The effect being that all the grounds literally ran into the dirt on the ground rod. They were not connected to the insulated underground ground wire that was supposed to connect the grounds in the sub panel to the common in the main panel completing the circuit in case of a hot to ground short. Very dangerous since the ground wire in the three way accidentally touching the hot essentially had current running through all the grounds. It was new construction so no sensitive equipment was ruined. I took a picture and sent it to the offending party who apologized profusely. So the bathroom gfi plug box circuit was getting power from a different circuit as was the case with every junction box in the building. In short you were correct in assuming the wiring was not properly grounded. Thank you. In a land of inspection this should have failed rough in.

    • @ethanavery9748
      @ethanavery9748 ปีที่แล้ว

      @@joecliffordson agreed lol, that could have been a bad day for someone if they found a way to touch the refrigerator and say the sink faucet. I'm just curious though, the grounds wouldn't have been connected to the ground rods at the sub panel correct? If they were; Couldn't the current have gotten back to the transformer via the main panel ground rods? Or maybe it was too far away. Electrical can still confuse me sometimes.

  • @kaysonntag74
    @kaysonntag74 2 ปีที่แล้ว +2

    My "best" experience was trying to pull off completely wet insulating tape from a phase while standing in a puddle with completely wet work shoes (even inside).
    That the insulating tape was wet, I could not see due to poor lighting conditions. It dripped water from the hall roof directly on the insulating tape and from there into the puddle.
    (Oh, the whole thing of course here in Germany, so with our 230V phase to neutral / earth).
    That was a moment where I would have liked the US - voltage levels.

    • @goaliedude32
      @goaliedude32 ปีที่แล้ว

      you shouldn't have been working in those conditions.

    • @kaysonntag74
      @kaysonntag74 ปีที่แล้ว

      @@goaliedude32
      You only make a mistake like that once in your life. Afterwards you are wiser. It will definitely never happen to me again!

  • @Jnglfvr
    @Jnglfvr 2 ปีที่แล้ว +1

    The example at 2:06 is very misleading. Touching hot with one hand while standing on the ground DOES result in a complete current path through ground back through transformer neutral through hot unless precautions are taken as you observe later in the video. The only time this is "safe" is if you are isolated from ground with thick rubber soles OR if voltage is supplied via an isolation transformer where the secondary has no ground reference.

  • @silversoozookee2839
    @silversoozookee2839 2 ปีที่แล้ว +2

    Funny timing this just came up in my playlist
    Another trade bypassed my LOTO and energized the circuits in the unit I was working on
    Got a charge felt it from right to left hand
    Right across my chest.

    • @whippitwill4842
      @whippitwill4842 2 ปีที่แล้ว +2

      They cut your lockout tagout? Jesus

    • @freddybee4029
      @freddybee4029 2 ปีที่แล้ว +2

      Did the bastard get fired permanently?

  • @notredo
    @notredo ปีที่แล้ว

    Wish you would have shown cutting the neutral in the circuit you were demonstrating. Touching the neutral returning from the light( or any load) and completing the circuit to the other neutral or ground will give a shock. Learned this 50 years ago and is one of the first things I tell new or wannabe electricians.

  • @99andrianmonk
    @99andrianmonk 2 ปีที่แล้ว +2

    What's your recommendation / thought about making sure the neutral in a circuit being worked on has not been pirated for another circuit? I was working in an older building and shut off the circuit I was working on only to get a jolt when I touched the neutral (I was kneeing on metal scaffolding). Turns out the neutral had been pirated for another circuit that was still live. The other circuit wasn't identified as a multiwire branch at the circuit board. What do you do to avoid same?

    • @Avaddon911
      @Avaddon911 2 ปีที่แล้ว +1

      You'll find this a lot in older construction. Shared neutrals were allowed until like 2011 nec. The best rule of thumb is just assume neutrals are shared in old work situations.

    • @modernbassheads5051
      @modernbassheads5051 2 ปีที่แล้ว

      My opinion? Untwist neutrals with insulated pliers , or cap them off or tape so your hand doesn’t graze them

    • @alexknight7191
      @alexknight7191 2 ปีที่แล้ว +1

      This is why using a multimeter to test an unfamiliar circuit is important. I was was installing a GFCI in my parents' very old garage and it kept tripping when I screwed in the fuse (yes, that old). Taking it back out to inspect, I got a little tingle on the neutral. Put the multimeter on it and lo and behold, there was about 6 volts on it but wasn't enough to trigger the non-contact detector. Discovered it was a shared (or pirated) neutral with another circuit that was hot. Could have been worse if there was more stray voltage on the thing, so now I always check with the meter before I touch anything.

  • @argekay1960
    @argekay1960 ปีที่แล้ว +1

    The problem with electricity is there is a threshold called ‘stick on milli amperage’ above which, you cannot let go of a conductor if you are holding it. Since you don’t know your body’s resistance between the two contact points, you don’t know where you sit on the ohms law equation. Always assume it’s live and you can die. Don’t be afraid, but respect it and have training. Electricity is not a hobby.

  • @braulioojeda5200
    @braulioojeda5200 2 ปีที่แล้ว +1

    Your videos help a lot to sharp the saw man, ty a lot.

  • @hunter-ie8mv
    @hunter-ie8mv ปีที่แล้ว

    One thing to note about completing circuit, with load. Very often if the load is much much lower resistance then your body so it doesn't really add any significant resistance to the circuit compared to you. There are of course exception which pull very little power like turned off electronics. Lightbulb I EU has cold resistance of only 130 ohm, hand to hand it can be from 3k to 200k ohms, very depandant on the skin resistance in your hands.

  • @kennethluedtkejr1903
    @kennethluedtkejr1903 2 ปีที่แล้ว

    At my grocery store I get shocked when touching the metal shelves or the check out counter. I dropped a jar of jelly. I have mentioned this to the store. I did meet a lady with the same problem.

  • @willthomsen7569
    @willthomsen7569 ปีที่แล้ว

    I became the load one time working in a basement and I thought the wire was dead and it wasn’t and I accidentally connected hot and neutral through my needle nosed pliers and it locked me onto the wire with 110 coursing through my body. Felt like an hour and I finally managed enough control over my body to lean back, then throw myself forward and the pliers flew out of my hands thank god. I literally couldn’t let go with my hands they wouldn’t move just GRIP. Few minutes to catch my breath I had to go finish the job too… made sure it was off this time

  • @WilliamMcCormickJr
    @WilliamMcCormickJr 2 ปีที่แล้ว

    Every time I have seen a fellow electrical worker get shocked, it was from them inserting their body in series between a cut neutral. Some electronic and induction loads can also cause a higher voltage to the body when the body is inserted in series between a cut neutral returning the hot through the electronics and or induction load.

  • @ronnieettienne6335
    @ronnieettienne6335 9 หลายเดือนก่อน

    Was welding metal guard rails to the top of a construction site in 95° sun, sweat pouring down my arm,I grabbed the guide wire and everything went all dark and fuzzy.

  • @that1electrician
    @that1electrician 2 ปีที่แล้ว +7

    I've been doing this for 7 years and have hit by 120, 208, 277, 480, 250VDC and 24VDC. Guess which one hurt the most.
    24 fkn volts dc hurt the most. I was on top of a liquid filler machine trying to reset a plc module. It was hot as hell in there and i was sweating like a stuck pig and also had a ton of cuts on my fingers and my nitrile gloves were ripped.
    To this day, I am still baffled that that incident hurt the most.
    Don't get me wrong- getting hit by 277 or 480 doesn't feel very good either.
    Edit- no I am not bragging about getting shocked. Thats nothing to brag about. It means you were being dumb and not testing the circuit dead or not wearing your ppe. But a few of those times I was still an apprentice and it definitely wasnt my fault.

    • @RonyTomo420
      @RonyTomo420 2 ปีที่แล้ว

      Sounds like you need to find another job

  • @notme22
    @notme22 2 ปีที่แล้ว +1

    Doesn’t matter how well insulated you are, if you quickly and lightly rub you finger over the wire you will feel a tingling sensation from a live wire due to the interaction of the electric field created by the live wire and the static created. Same thing with the moisture sensor in your clothes dryer but safer to try since the 240 is passed through a couple megohm resistor. Remember, when it comes to electricity and just about everything else, contact time matters. Swiping your finger across a wire is not as likely to electrocute you as grabbing a wire is!! Arc flash from a 15A circuit with stranded wire creates a good size blinding blue fireball that could probably cause some injury if done close to the face.

  • @thomasdado7770
    @thomasdado7770 ปีที่แล้ว

    While I was in South Africa, and staying on a ranch, i would get shocked doing everything in the kitchen - from the appliances. Cooking, fridge, toaster oven, the washing machine was in the kitchen, and when I pulled the clothes out. So I never was able to go in the kitchen when power was on without having my bluntstone boots on. Everything in the area was 220 who would I mention it to that landlord? He just laughed and said “if that’s my biggest worry about having a good time in Africa.”

  • @wademchenry1560
    @wademchenry1560 2 ปีที่แล้ว

    I always had rubber mats or a mini pallet to stand on when replacing a meter enclosure or a line side tap.

  • @gnrfan713
    @gnrfan713 2 ปีที่แล้ว

    We had a salt lamp night light plugged into the gfi in our bathroom. They are really not safe as the salt draws moisture and makes that moisture more conductive. My wife went to pull it out of the outlet and used both hands. Got a little shock. I was surprised it didn't trip the gfci. I tested it afterwords and it was working. My only guess is she was getting less then 5ma of current.

  • @Martin4Mary4Ever
    @Martin4Mary4Ever 2 ปีที่แล้ว +1

    Always use a multimeter, I've worked on busbars where the main shut off did not work.
    Everytime, I thought, "awwh.. Shit, this thing is going to kill me. Grab a 2 by 4."

  • @america0014
    @america0014 2 ปีที่แล้ว +1

    First time I really had a question. Okay so say you touch the hot wire and that electricity always want to go back to the source, theoretically therefore would you only be hit by 120V instead of the full 240V? My thought being that ground and neutral will be bonded at the main panel and if you were to touch a hot wire and have current flow through one's body...then wouldn't you only be being shocked with 120V since ground is bonded to neutral?
    Also I should mention I have been shocked with by a single phase 460v airconditioner, but what probably saved my life was that my pinky had been touching a grounded plate so I could feel it go through my hand pretty violently. I should also mentioned that this could had been avoided if I had double checked my operator's powercord connection. She had wired in a 14/3 powercord used only for testing purposes (cord used for a 3 phase wye system) instead of a 14/2 (leaving a live wire dangling on the back of the unit we had been testing. Even thought L1-L2 are being used, L3 will still be energized). In this theory, I believe I had been shocked with 266V (460 divided by the Sq. Root of 3 equalling 265 and some change) since I had been grounded through the back plate of the unit. The main point of my long winded story is you might have done everything by the book, but always double check the electrical situation of another person working on the same electrical job as you.
    If felt like one of those zombie dogs biting my hand and violently shaking my hand. I tried to move my hand and it felt like a thousand rubber bands holding my hand down as I tried to move it in a upwards direction.

  • @garden_therapy_nj
    @garden_therapy_nj 2 ปีที่แล้ว

    I work for a company where we have to work on hot wires. It’s actually critical that the power stays on.

  • @ronny9407
    @ronny9407 7 หลายเดือนก่อน

    I never use a voltmeter to check power. I can touch 110 or 220 and tell the difference. I am trained and conditioned to do this. A long as o am not touching ground i use my thumb and forefinger to test voltage. It works fine

  • @el-magnifico3485
    @el-magnifico3485 หลายเดือนก่อน

    I'm not a professional, lol, but when I work with live wires, I make sure to take the ground and cap the wire before proceeding.

  • @lukehubbard4915
    @lukehubbard4915 2 ปีที่แล้ว +1

    Love the visuals and definitions added in

  • @docferringer
    @docferringer 2 ปีที่แล้ว +2

    I only use Fluke meters and leads, mainly because I once vaporized a set of leads trying to probe a light switch and I came away unscathed. :P I work at a manufacturing/office space, so it's smart to check the voltage of lighting circuits before swapping out any fixtures. (And we had several sparkies out for lighting mods previously, so god only knows what they changed.) Case in point, there were a lot of angry pixies hiding out in a light switch of all places. I probed hot and ground to check voltage, since the lighting in that building runs on a mix of manufacturing and office voltages. *POW* the lights for half the building go out. That was...new. I checked the meter and everything was set correctly for a voltage measurement--my Fluke 87V was ready to go. I reset the breakers and the lights come up fine. I perform the same test with everything set the same and I get the standard 277V. To this day I have no idea what happened....other than arc flash vaporizing half an inch off one of my test leads and giving me a sunburn on the inside of my eyeballs. :)

  • @neilmarsh1904
    @neilmarsh1904 ปีที่แล้ว

    "Most mistakes get made because somebody got in a hurry." True in every trade and profession.

  • @SlackersIndustry
    @SlackersIndustry 2 ปีที่แล้ว +1

    if i use a trick tracer and it doesnt light up meaning no voltage then why should i test with multimeter to see if no voltage? thanks great videos.

    • @superthrustjon
      @superthrustjon 2 ปีที่แล้ว +1

      Multimeter is much more reliable

    • @matthew-h
      @matthew-h 2 ปีที่แล้ว +2

      Batteries could be dead.
      You could forget to turn it on.
      Some models can give false negatives due to a design flaw and have actually been recalled.

  • @peterford9369
    @peterford9369 ปีที่แล้ว

    I'm not an electrician but I do thing's like panels, sub panels etc as a remodeling person. I have friends that are electricians that say that's part of electrician school is to hold a live 110 ? So to understand that sometimes the reaction can cause more harm than the initial zap. True or false?
    I've burned up linesman pliers cutting a hot that a probe said was not. And I've been ticked by a 110 slip grounding. And it's always,pull away. It's hard to figure training your brain to hang on to something that hurts. Like touching a hot stove or slice of cuban bread 😂. I just wondered. I've watched your videos for a long time. And appreciate your teachings.👍👍

  • @fjl05
    @fjl05 2 ปีที่แล้ว +2

    I've never been electrocuted but i have been shocked many times. A person once asked me what it feels like to get shocked. I thought about it and realized that from my experience, I've never actually felt pain from a shock. So i told them that it doesn't hurt but that its a very VERY *VERY* uncomfortable feeling that will make you react very fast. Lol

    • @bertblankenstein3738
      @bertblankenstein3738 2 ปีที่แล้ว +2

      I've had it both ways. One time I'm holding on to alligator clips with 120v thinking "yhea this is uncomfortable, I should let go." and another time I got a good jolt and was white for the afternoon.

  • @chancefincher2194
    @chancefincher2194 9 หลายเดือนก่อน

    Subject: Water heater
    My side is fine
    Top thermostat of the water heater is fine
    Breaker is fine
    Bottom thermostat is 1/2 voltage
    Two issues
    When I was messing around in the top thermostat, I got shocked. Ground issue?
    Had no hater water. Top thermostat reset button had tripped. Reset the reset button. The WH wouldn't stop filling. I heard the drip from the pressure relief valve. It almost blew. What's up?
    Additional:
    I trip breakers when load is high. For example; in bedroom, I can't have lights on, and run a shop vac at the same time. Lights flicker. Fans click
    Any tips would be helpful. I know, I just need to call an electrician. Seems so simple at times, though.

    • @sewerrat7612
      @sewerrat7612 7 หลายเดือนก่อน

      Water and electric tripping would be two different issues on a water heater. Water heater won't overfill if you have a pressure reducing valve that's not working properly could trip the t&p. Other option would be a closed circuit a failed/failing expansion tank. As for voltage in water heater could be bad thermostat or possibly bad fuse in disconnect in rare cases can show that way.

  • @brandonprice2897
    @brandonprice2897 ปีที่แล้ว

    I do some electrical work in the commercial environment and I can never find the proper fitting gloves to wear. I have started using like electrically insulated tools to prevent the possibility of a major problem. But I was wondering if you could point me in the right direction of where to find proper fitting gloves. Yes I have small hands. And some smalls fit me and in some cases I can get medium to fit me. Please help if you might know where to look. Thanks in advance.

  • @classicman1828
    @classicman1828 6 หลายเดือนก่อน

    I have seen a video where someone is walking in a road next to light pole while the ground is wet after raining than he got electrocuted to death just be walking close to it! the horror comes after when people came to help him and they all died not knowing what is happening, when you see water near electricity just walk the other way.

  • @Saturn2888
    @Saturn2888 หลายเดือนก่อน

    Does that 5% include working on the power panel of a house? You can turn off the breaker box itself, but what if you add another breaker box? I'm assuming you have to shut it off outside right?

  • @jimjjewett
    @jimjjewett 2 ปีที่แล้ว

    If asking whether a circuit is off, it might help to say "it claims it is" instead of "yes". Because sometimes the label lies.

  • @brianlittle717
    @brianlittle717 11 หลายเดือนก่อน

    I am always very adamant about putting the rotation direction wires of a condenser motor below the grill on an air conditioner. Lots of people will install the condenser motor and they don’t know which direction it will turn so they put the wires up through the grill so they can easily switch it later. Then after a few years the sun eats away the insulation and some kid gets out of the swimming pool barefoot in the grass and somehow comes in contact with it. I always look at the diagram on the motor and it will tell you the combination for a certain rotation. That way you can wire it right before you turn it on. And get the wires inside the unit where they belong.

  • @vince6829
    @vince6829 2 ปีที่แล้ว +1

    Thank you for sharing your knowledge. Much appreciated.

  • @Dinco422
    @Dinco422 ปีที่แล้ว

    2:10 IMPORTANT: You forgot to mention you feet.... if your feet is not isolated and you still have the hand in the pocket while touching just 1 wire doesn't matter.... you're still electrocuted. Keep your feet isolated, wear rubber things (anything rubber) Even flipflops made of thick rubber... although not recommended ofc, still works.

  • @buffydog21
    @buffydog21 2 ปีที่แล้ว

    I worked live on a circuit, when I changed a light switch on knob and tube wires. I didn't know, where the breaker was for that circuit. I touched the 2 wires together and found out that the light turned on and it didn't break the breaker. I was wearing a pair of dish washing gloves. I'm just a homeowner.

    • @freddybee4029
      @freddybee4029 2 ปีที่แล้ว

      Stupidity is going to play Darwinism, on you one of these days, not later, but sooner than you think.

  • @blackheart_mechanic
    @blackheart_mechanic ปีที่แล้ว

    What if. Those two cut wires the black one will be stick together then i will hold it.but im not connected to the ground.i will not be shock right???

  • @dylanstack8710
    @dylanstack8710 11 หลายเดือนก่อน

    So does this mean you could twist a live wire for a splice with one bare hand while standing on a ladder?

  • @mtoohill
    @mtoohill ปีที่แล้ว

    I was going to replace a GFCI outlet. Breaker off, plugged in lamp, and it didn't light up. Checked with the live wire tester, nothing. Grabbed pliers, and a shock ran up my arm and out my foot.

  • @Willesden_Rab1_TV
    @Willesden_Rab1_TV 8 หลายเดือนก่อน

    very well explained , thanks from london uk 🇬🇧

  • @TheLahore123456
    @TheLahore123456 2 หลายเดือนก่อน

    My friend getting minor electric shocks and vibration by upstsir neighbour. Any sugestion

  • @PeterJames143
    @PeterJames143 ปีที่แล้ว

    so if you have to touch two things how do animal electrical fences work?