TA-0368: OWON CM2100B AC/DC Clamp Multimeter 20.000 Counts Bluetooth

แชร์
ฝัง
  • เผยแพร่เมื่อ 10 ก.ย. 2024
  • Testing the Owon Clamp and BlueTooth App. it can exports a CSV file.
    CM2100B Eleshop: www.eleshop.nl...
    CM2100B AliExpress: s.click.aliexp...
    CM2100B Amazon: www.amazon.nl/...
    Related Items:
    Volt/Current Pro LB02A go.tonyalbus.c...
    DMMcheckPlus go.tonyalbus.c...
    Volt/Cur FNIRSI SG003A go.tonyalbus.c...
    Voltage/Current LB02G go.tonyalbus.c...
    Related Videos:
    Video LB02A/SG003A : • #260 Process Calibrato...
    Video DMMcheckPlus : • #228 DMMCheck Plus Cal...
    Video Keithley 224 : • #243 Keithley 224 Curr...
    Video Advantest R6142 : • TA-0349: Advantest R61...
    #OWON #CM2100 #CM2100B

ความคิดเห็น • 45

  • @miguelc_seeker
    @miguelc_seeker 11 หลายเดือนก่อน +2

    Hola, yo compré esa pinza por ALIEXPRESS hace unos meses desde chile.... todo funcionaba perfecto , menos la funcion V.F.C o filtro LPF, cuando media corriente y la activaba , se caia demaciado la corriente, estaba mal esa función.... entonces me puse en contacto con OWON, les mande videos de la falla y constancia de la compra de ALIEXPRESS , y despues de varios correos me enviaron otra pinza por garantía, y ya vino sin falla en la función V.F.C .....por lo demas es excelente pinza, muy precisa en corrientes bajas. La recomiendo

    • @TonyAlbus
      @TonyAlbus  11 หลายเดือนก่อน +2

      Great to hear Owon helped you out with your broken meter, even though you bought it from AliExpress .. good service, thank you for sharing that.

    • @miguelc_seeker
      @miguelc_seeker 11 หลายเดือนก่อน +2

      @@TonyAlbus si, no tenía muchas esperanzas que reconocieran la garantía, pero me asombro lo correcto que es OWON. eso te da confianza con la marca 👏👍💰💵🇻🇪🇨🇱

    • @TonyAlbus
      @TonyAlbus  11 หลายเดือนก่อน +1

      @@miguelc_seeker Yes it does, Great.!

  • @qzorn4440
    @qzorn4440 11 หลายเดือนก่อน +3

    A most impressive Bluetooth multimeter. 🥳 Amazon $50 OWON CM2100B Clamp Meter 😎 Thank you Tony.

    • @TonyAlbus
      @TonyAlbus  11 หลายเดือนก่อน +2

      Thank you!

  • @mostlypostie1
    @mostlypostie1 11 หลายเดือนก่อน +3

    This looks and works very similar to my UT-210E, but with more counts and BT. I see "basically" the same performance from my UT-210E. Which is great for the price! Thanks for the video 👍

    • @TonyAlbus
      @TonyAlbus  11 หลายเดือนก่อน +1

      Thanks, yes your are correct, looks a lot like the uni-t with those differences.. funny

  • @nickking8317
    @nickking8317 11 หลายเดือนก่อน +2

    Owon is awesome I love their meters I got a bench top and a hand held

    • @TonyAlbus
      @TonyAlbus  11 หลายเดือนก่อน +1

      Thanks! yes a nice little meter.

  • @Petertronic
    @Petertronic 11 หลายเดือนก่อน +3

    Good review, quite a decent clamp meter from Owon. A year ago I bought the EEVblog BM036 meter which was nearly £100 and it's specs are very disappointing, e.g. fixed voltage range of 600V with 0.1V resolution, 6000 count. I will probably sell it.

    • @TonyAlbus
      @TonyAlbus  11 หลายเดือนก่อน

      Thank you.. this one or have a look at UT-210E .. i see in the comments

  • @grerlab2777
    @grerlab2777 11 หลายเดือนก่อน +2

    Good to know... Thank you Tony for the beautiful video...
    By the way... You really have a beautiful laboratory... 👍

    • @TonyAlbus
      @TonyAlbus  11 หลายเดือนก่อน +1

      Thank you so much Grer!

  • @johnshaw359
    @johnshaw359 11 หลายเดือนก่อน +1

    Bought one, it works well. Thanks.

    • @TonyAlbus
      @TonyAlbus  11 หลายเดือนก่อน

      Thank you for user feedback!

  • @0nyxghost
    @0nyxghost 5 หลายเดือนก่อน +2

    I purchased this clamp meter and used it for a week and found it very accurate and compact. You did not test the frequency mode. It will measure 20 MHz with a signal greater than 8 Vpp from a signal generator. I used 10Vpp sine wave without issue over the full range.

    • @TonyAlbus
      @TonyAlbus  5 หลายเดือนก่อน

      Thank you for this extra information!

  • @noneofabove5586
    @noneofabove5586 10 หลายเดือนก่อน +1

    I liked your low amp test. Having a reading at 10ma is quite good. I have not seen this test done on the uni-t yet.

    • @TonyAlbus
      @TonyAlbus  10 หลายเดือนก่อน

      Yes very sensitive, very nice.

  • @kaanyil5726
    @kaanyil5726 11 หลายเดือนก่อน +2

    great video Thank you!!
    I have a question I am looking for a current sensor which records the values and can transmit them to the computer. I saw that the clamp has a recording mode (without bluetooth connections) is there a limited number of measurements recorded? For example, I can place the clamp and let it take current measurements for 8 hours and at the end connect the phone via Bluetooth to extract the measurements?

    • @TonyAlbus
      @TonyAlbus  11 หลายเดือนก่อน +1

      Thank you. Good question, i really did not test any offline logging, i did not expect it to be able to. Maybe you can find it on the Owon website? i would be surpriced it can, usualy only higer level multimeter would be able to do that.

    • @kaanyil5726
      @kaanyil5726 11 หลายเดือนก่อน +2

      ​@@TonyAlbusthanks you! ☺️

  • @belgua-nh8rm
    @belgua-nh8rm 6 หลายเดือนก่อน +2

    20.000 counts, but not when measuring current?
    Or am I wrong?
    means 0- 19999 = 20.000
    min 10:42 0.032 A --> only 2.000 Counts,
    min 5:34 100.07 Ohm --> 20.000 Counts

    • @TonyAlbus
      @TonyAlbus  6 หลายเดือนก่อน +1

      Yes that is exacly what the video is for.

  • @mrpetit2
    @mrpetit2 11 หลายเดือนก่อน +4

    2 things I noticed:
    1. in amp mode (the most important mode for this meter), it's not 20.000 count, but only 2000 count! So the same as competitors like the Uni-T UT210E (which even can be hacked to 9999 counts). That's a bit disappointing.
    2. the logging is not consistent. In the data stream you can see that it sometimes log's a value 2 times per second and sometimes even 5 times per second. Because I don't see a decimal on the seconds value, a dataset like this (in a csv file for example) can't really be processed for example to calculate derivative values of this log (for instance if you want to calculate milliamps-hour). This is something that has to be improved imho to actually be useful in a more advanced application.
    So I have a bit of mixed feelings about this meter. If I look at both manuals, the Uni-T UT210E also has more accurate specs in the 2A DC mode (2%+3dig instead of 2%+8dig for the Owon meter), and the UT-210E has exactly the same price as the OWON CM2100 (without bluetooth) (at eleshop at least).
    Can you check that if you log on the fastest setting (

    • @TonyAlbus
      @TonyAlbus  11 หลายเดือนก่อน +1

      Hi Guido,
      Well spotted! about the logging to file, that was my mistake, the manual clearly says: set interval between 1 to 40 sec. i left it at

  • @gixerags750
    @gixerags750 11 หลายเดือนก่อน +1

    nice video... ps i want you're Marconi !!!

    • @TonyAlbus
      @TonyAlbus  11 หลายเดือนก่อน

      Thanks!

  • @foxythedirtydog4494
    @foxythedirtydog4494 7 หลายเดือนก่อน +1

    I didn't watch it all but couldn't see him testing NCV. I saw another review alongside the UT 210E and the NCV was nowhere near as good so I bought my 4th UT210E instead as NCV is probably my most used feature.
    Input protection also looked not as good.

    • @TonyAlbus
      @TonyAlbus  7 หลายเดือนก่อน

      i didn't real your whole text, but i think i did not test NCV, but i don't remember, it is not the most interesting function in my opinion, i was mor einterested in the 20.000 counts.

    • @foxythedirtydog4494
      @foxythedirtydog4494 7 หลายเดือนก่อน

      @@TonyAlbus thanks for the reply. NCV is very much underated in many reviews as they are usually done by people at a bench who would not have much use for it, whereas NCV is probably my most used function.
      I work on commercial/industrial HVAC equipment where testing for dead is very important. Panels can have two supplies. Lights controls and monitors often are isolated elsewhere.
      I find NCV is a quick and effective double check.
      NCV is also great for quickly checking for power, for example to a faulty solenoid coil without having to remove the connector and probe it. It's good at finding breaks in cables. Even checking the fuse in a plug (UK type) can be done without removing the plug.
      Probes often give a false no voltage display if touched on corroded or coated areas.

  • @zdzisiek1979
    @zdzisiek1979 11 หลายเดือนก่อน +1

    👍

    • @TonyAlbus
      @TonyAlbus  11 หลายเดือนก่อน

      Thank you!

  • @kellycowett6254
    @kellycowett6254 หลายเดือนก่อน

    Quick question I'm new to this stuff can that be attached to oscilloscope

    • @TonyAlbus
      @TonyAlbus  หลายเดือนก่อน +1

      As far as i know, it works all by its own. and can unmodified not be used as a probe only for a scope.

  • @piotr-Garou
    @piotr-Garou 11 หลายเดือนก่อน +1

    👍. Kiedy nowe odcinki FF?

    • @TonyAlbus
      @TonyAlbus  11 หลายเดือนก่อน +1

      Thank you for asking! .. i will start the Fluke Friday again soon.

  • @johnshaw359
    @johnshaw359 11 หลายเดือนก่อน +1

    Does the ammeter default to ac or dc?

    • @TonyAlbus
      @TonyAlbus  11 หลายเดือนก่อน +1

      Hi, John, the Amp setting default to AC... The Volt setting defaults to DC

    • @johnshaw359
      @johnshaw359 11 หลายเดือนก่อน +1

      @@TonyAlbus Thanks, why do they do this for hobbyist grade products...P.I.A, every time you have to press a button, the D.C button on my uni-t210e is knackered because of this idiocy.

    • @TonyAlbus
      @TonyAlbus  11 หลายเดือนก่อน

      @@johnshaw359 would be better to remember the last setting per mode .. i agree