कैसे चलाये बिना ग्रिड के सोलर ऑनग्रिड सिस्टम ! || How to Run Solar Ongrid system without Grid ?

แชร์
ฝัง
  • เผยแพร่เมื่อ 5 ต.ค. 2024
  • कैसे चलाये बिना ग्रिड के सोलर ऑनग्रिड सिस्टम ! || How to Run Solar Ongrid system without Grid ?
    #ongrid #zeroexport #powerlimit #solarsystem #offgrid #siteanalysis #solargeneration #solarsystem #electricaldesign #R&D
    Solar
    Safest
    Smarter
    Saur urja
    Biljli Kaise bachaye
    Solar se Bijli Kaise Bachaye
    Benefits of Installing solar
    Profitable solar
    Solar k Fayede
    Solar Lagane k Fayade
    MCB
    MCCB
    ACB
    AJB
    ACDB
    DCDB
    Lighting Arrester
    walkway
    cable Tray
    Solar Panel
    Solar Inverter
    Solar Cable
    AC Cable
    Follow me on -
    Telegram- t.me/+uVOzUWjD...
    LinkedIn- / raman-kumar-666436141
    Facebook - / solarfacts-37057195372...
    solar structures
    Solar panel mounting structure
    Solar mounting structure
    acdb and dcdb for solar system
    acdb box price
    dcdb box for solar system
    dcdb box price
    long rail solar structure
    mini rail for solar panels
    mini rail solar structure
    solar mounting structures
    solar panel structure
    solar structure
    solar structure types
    types of mounting structures for solar panels
    types of solar mounting structure
    types of solar structure
    mounting structure for solar panels
    mono rail solar structure
    solar acdb box
    solar acdb dcdb box
    solar dcdb box
    solar mini rail
    standing seam solar structure
    tilted solar structure
    acdb box for solar
    dcdb box for solar
    Video link -
    1. How solar zero export works.- lnkd.in/evPgfuj2
    2. What is Enphase microinverter ? // Microinverter & it’s step wise installation explanation. - lnkd.in/e3mr7HjF
    3. Concept of Solar Inverter Overloading //Solar inveter overloading is right or wrong !!!! - lnkd.in/eDNXTc2z
    4. What is Reactive Power ? // Why Industries Power Factory become poor after installing Solar! - lnkd.in/ei8S_d_m
    5. What is CT? What is CT Ratio? How to select CT? - lnkd.in/eCkNRTtZ
    6. How to check Current Transformers? - lnkd.in/eT5gc99e
    7. Why Solar Systems are not Success with Zero Export device. // Precautionary Majors for Zero Export. - • Why Solar Systems are ...
    8. How to design SolarEdge string // How to use SolarEdge string designing tool. - • How to design SolarEdg...
    9. How to install solar panel // What is the right way to install solar panel. - • How to install solar p...
    10. How to calculate string design for solar Inverter? -- lnkd.in/ekujjSpm
    11. How to design stand alone solar system & Battery bank capacity - lnkd.in/exEYzYdD
    12. What is surge protection device? // How to protect our system from surge? - • What is Surge Protecti...
    13. What is Armoured cable? // what is the benefits of Armoured cable?- • What is Armoured cable...
    14. Why Single Core Cable Comes with AL Armoured not with Steel? -- • Why Single Core Cable ...
    15. How To Calculate Neutral Current? 3 Phase Neutral Current Calculation! Unbalance current calculation! - • How To Calculate Neutr...
    16. What is Neutral Floating? // Why voltage increase // what happen if neutral breaks in a transformer. - • Video
    17. Solar Power Plant Shadow Analysis ! // Shadow Calculations for Row Spacing.
    • Solar Power Plant Shad...
    18. What is 1000VDC and 1500VDC solar system.// Advantage and Disadvantage of 1500VDC Solar System - • What is 1000VDC and 15...
    19. What is Netmetering and What is Gross metering. // Netmetering and Gross metering billing method. -- • What is Netmetering an...
    20. What is PID (Potential Induced Degradation) ? Why PID Occurs in Solar Panel ? / How to check PID ? -- • What is PID (Potential...
    21. How to select solar panel on technical basis ? // Best solar panel selection as per project. -- • How to select solar pa...
    22. What Is Solar PERC Technology? // Mono PERC // Poly PERC. // Passivated Emitter and Rear Contact -- • What Is Solar PERC Tec...
    23. How to Calculate size of Earting Conductor and Earthing Electrodes? // Earthing Calculation. -- • How to Calculate size ...
    24. How Mismatch affect Solar Plant Generation?What are the causes of Mismatch losses ? -- • How Mismatch affect So...
    25. Why Solar Energy Consume First ? // How Import and Export Works in Solar system ? -- • Why Solar Energy Consu...
    26. What is P-Type and N-Type Semiconductor? // How Solar Cell Works? -- lnkd.in/e6Ydxc2P
    27. Design your Solar Plant On your Own /Battery Selection and Sizing Calculation /Battery Calculation. -- • Design your Solar Plan...
    28. How Lithium-Ion Batteries Are Cheaper Than Lead Acid? // C Rating of Battery // C-10, C-20 and C-5. -- • How Lithium-Ion Batter...
    29. Comparison between string inverters vs micro inverter // Benefits of micro inverter. -- • Comparison between str...
    30.What is Skin Effect ? // Why Skin effect happens in AC not in DC ? // Why current flow through surface of conductor ? -- lnkd.in/eHTtuFtK
    For more information contact us 😊.
    Name - Raman Kumar
    Contact No- 9871073342

ความคิดเห็น • 252

  • @RajeshPatel-jq8sd
    @RajeshPatel-jq8sd 4 หลายเดือนก่อน +4

    Aap live canection krke dikawo isko load bailensing ke sath off grid ongrid canection zero export units canectonstions, iska video singl phase or three phase 2 me

    • @dhakedramniwas4375
      @dhakedramniwas4375 3 หลายเดือนก่อน

      @@RajeshPatel-jq8sd th-cam.com/video/tN5dvyBiCpg/w-d-xo.htmlsi=pYeGiilnt181dddO

  • @NurulIslam-dy9jw
    @NurulIslam-dy9jw 6 วันที่ผ่านมา

    Sir, I am from Bangladesh. I am watching your videos & I got lot of knowledge to watch videos.
    Sir please make a video on power conversation system.

  • @PankajKumar-ux5fu
    @PankajKumar-ux5fu 2 ปีที่แล้ว +4

    Awesome Best Information given by you Thanks a lot

  • @vaibhavpurwar316
    @vaibhavpurwar316 5 วันที่ผ่านมา

    Good explanation Ramanji

  • @pr5991
    @pr5991 20 วันที่ผ่านมา

    just use small 12v 50-watt inverter to give ac signal to the on-grid inverter and you can run load on it. Switch off the main switch so no power can be imported or exported, the small inverter will serve the purpose of grid signal, make sure your load is always more than 50 watts. It is called artificial grid forming. By this method you don’t need to buy any other inverter or change the connections of solar panels. Your on grid inverter must have CT and you must set to zero export limit.

  • @umerbutt9651
    @umerbutt9651 9 หลายเดือนก่อน +4

    How can we combine a hybrid inverter and ongrid inverter system? if grid is not available then how can we keep running the on-grid system using a hybrid inverter system?

  • @ravidutta3534
    @ravidutta3534 ปีที่แล้ว +1

    Thanks for you email. My question was specific to my requirement Load is 225 KW, solar on grid system under planning is 300 KW. Grid is not available. Reference voltage to be sourced from a 250 KVA D. G, set. To avoid minimum continuous loading of 30% on the DG set and saving fuel. My question was if I drop the idea of DG set altogether and opt for a off grid as power source what size/capacity off grid system should I opt for to service this load of 225KW

    • @solarfacts4242
      @solarfacts4242  ปีที่แล้ว +1

      Sir when you go for your factory at least one reliable power source is very very important because when you install an offgrid you can run your online grid system but the challenge is suppose you want to run 250
      Kw load at your factory but due to non availability of irradiation your offgrid as well as your ongrid system is not capable to give you that much power in that case your system will trip and this is very common.
      That’s why we told at least one reliable source

  • @nitinkale560
    @nitinkale560 6 หลายเดือนก่อน +9

    मतलब ग्रिड फेल होने पर हमारा ही सोलर हमको पावर नही देगा। यह तो बड़ी नाइन्साफी हैं सरा😢

    • @Bluesky.c
      @Bluesky.c 6 หลายเดือนก่อน +2

      😂😂😂😂😂 yeh bus murkh bnaney waali yojna h 😂🤣 sarkaar ko dena h toh hybrid technology wala dena chahiye taaki phir uska use kiya ja skey

    • @nitinkale560
      @nitinkale560 6 หลายเดือนก่อน +1

      @@Bluesky.c Everything is guaranteed only for 5 years. It is supposed to run for 25 years.We should not go in loss after 5 years.

    • @jayprakashshrimali
      @jayprakashshrimali 2 หลายเดือนก่อน

      अरे भाई ग्रिड मैं जब पावर होता तब भी हमे तो सोलर का पावर मिलता ही नहीं है देखो हमे अपने घर मैं ग्रिड से पावर लेके सब चलाना है उसका एक बिल आएगा और जो हमारा सोलर सिस्टम है वो पावर बनाके ग्रिड को देगा उसका हमे पैसा मिलेगा ... कुल मिलाके बात ये है के जब पावर कट रहेगा तब हमे बिजली नहीं मिलेगी

  • @learnandcreation3744
    @learnandcreation3744 ปีที่แล้ว +2

    I am a technical person, your explanation is very good and informative. One major concern is when power fails, suddenly off-grid inverter power with phase difference kicks in.... can solar inverter sense that and automatically restarts again with 30sec delay or we should use an automatic changeover to mains supply and inverter supply.

    • @jaganmangat1989
      @jaganmangat1989 ปีที่แล้ว

      Jo inverter se chla raha hai use inverter se chalne do,jo high power requirements wale devices hai wo is method se chal sakte hai. I hope so!

    • @learnandcreation3744
      @learnandcreation3744 ปีที่แล้ว

      @@jaganmangat1989 Aap aise use kar rahi ho kya?

    • @inderpalsingh1426
      @inderpalsingh1426 ปีที่แล้ว

      ​@@jaganmangat1989inverter se chal jage kya?

    • @solarfacts4242
      @solarfacts4242  ปีที่แล้ว

      For automatic you should install PLC

  • @nityanandasahoo8854
    @nityanandasahoo8854 5 หลายเดือนก่อน +2

    Plz confirm, without netmetering if not connected zero export device, main meter will increase kwh reading?

  • @puneetgarg8305
    @puneetgarg8305 2 ปีที่แล้ว +2

    I already install Ongrid system like this working well in day time

  • @ramlakhandewangan1028
    @ramlakhandewangan1028 2 ปีที่แล้ว

    Sir ! बेसक आपने बहुत ज्यादा अच्छा विश्लेषण किया व समझाया निश्चित सराहनीय है , और जिसको भी इलेक्ट्रिकल्स की समझ है उसके लिये काफी सरल भाषा मे समझाया है । आप कहते है " ऑफ ग्रिड को ग्रिड के विकल्प के तौर पे इस्तेमाल कर सकते हैं । " मेरा प्रश्न यह है कि, क्या ऑफग्रिड सिस्टम ग्रिड की जगह काम कर सकता है ? मैं यह प्रश्न इसलिये कर रहा हूँ sir ! मैंने यू ट्यूब पर ऐसे वीडियो भी देखा है , जिसमे यह बतलाया गया जाता है कि ऑफग्रिड की फ्रीक्वेन्सी सपोर्ट नही करती है । कृपया बतलाएं सच क्या है ?

    • @solarfacts4242
      @solarfacts4242  2 ปีที่แล้ว

      no i dont think so

    • @Prowess0906
      @Prowess0906 2 ปีที่แล้ว

      It should be pure sine wave output from your inverter

  • @jayprakashshrimali
    @jayprakashshrimali 2 หลายเดือนก่อน +1

    आप की बाते पल्ले नहीं पड़ी .....अगर कोई छोटे से एक्जाम्पल से समजाते तो क्या जाता ?? दूसरी बात लोड को कंट्रोल ...अरे भाई कंट्रोल करना ही क्यो है ॥लोड का मतलब है की जो भी डिवाइस है उसको चलाने के लिए जो बिजली चाहिए उसको लोड कहते है और जितना लोड होगा उससे ज्यादा सोलर का उत्पादन होना चाहिए इसमे कंट्रोल वाली बात कहा आई ?

  • @charchitrajput8020
    @charchitrajput8020 2 ปีที่แล้ว +5

    I already ordered an ongrid system but after the system arrived my vendor said that it's useless when the grid is offline. I live in town and my main reason was that I experience power outages, i already spent so much money on it and now i am being informed that it's useless, please tell me how can I utilise it when grid is offline,I asked them and they said that they will connect a changeover on the DC power generated by my solar panels and in case of an outrage i can simply route the DC from my panels directly to my battery pack through a solar inverter ( instead of going to grid side inverter). Is it a good solution?

    • @netrocker9990
      @netrocker9990 2 ปีที่แล้ว +1

      Use hybrid inverter. Or use a off-grid system by tapering ongrid systems pv array to charge off-grid system

    • @solarfacts4242
      @solarfacts4242  2 ปีที่แล้ว +1

      It is not a good practice
      This can damage your battery and system

    • @zigpre-solutions3674
      @zigpre-solutions3674 ปีที่แล้ว

      Use hybrid inverter it's very usefull in rural area

    • @jayawantbavaskar9369
      @jayawantbavaskar9369 ปีที่แล้ว

      @@netrocker9990 u can use Solar management system (SMU) that can reachrge u rbattery

    • @dimplesharma9960
      @dimplesharma9960 ปีที่แล้ว

      @@solarfacts4242 what is your contact number Sir.....

  • @ravidutta3534
    @ravidutta3534 ปีที่แล้ว +2

    In that case a 6 KW off grid system as a power source to supply a 50 KW grid connected system a continuous power to eliminate a DG set. will also not work if all of a sudden irradiance disappears and the complete load of 50 KW grid connected system gets shifted to the 6 KW off grid system In my case the load is 225KVA, grid connected solar system is 300 KW and to give continuous power to the inverter a 250 KVA DG set is planned. As suggest by you a reliable source other the the solar is essential to run the factory. If the grid is not available, an equal size power source is required, in my case it has to be a DG set of 250KVA. Your thoughts please.

    • @solarfacts4242
      @solarfacts4242  ปีที่แล้ว +1

      No In case of low irradiation load will not shift to 6 Kw that we can control through PLC command but yes if irradiation is low your device will trip

  • @narendersingh3
    @narendersingh3 3 หลายเดือนก่อน

    Total (off grid + On grid) system cost of the same load. Ye bhi bataye pls

  • @atwalcheapenergy3918
    @atwalcheapenergy3918 2 ปีที่แล้ว +2

    Ur Tech. Is very complicated it is not possible for a Comman man. But I developed a device which can convert any ongrid PV string into off grid PV string automatically and it's working as a off grid solar system when grid power not available

    • @code-jz1ds
      @code-jz1ds ปีที่แล้ว

      Could you please share the details?

    • @GurbaniGyandhara
      @GurbaniGyandhara ปีที่แล้ว +2

      Veer ਵੀਰ ਜੀ ਮੈਂ ਪੰਜਾਬ ਤੋਂ ਹਾਂ ਤੇ ਮੈਂ ਆਪ ਜੀ ਦਾ ਉਪਕਰਣ ਖ਼ਰੀਦਨਾ ਚਾਹੁੰਦਾ ਹਾਂ। ਮੈਨੂੰ ਆਪਣਾ ਸੰਪਰਕ ਨੰਬਰ ਦਿਉ, ਜੋ ਬਣਦੀ ਸੇਵਾ ਹੋਵੇਗੀ ਉਹ ਦੇ ਦੇਵਾਂਗਾ..

    • @solarfacts4242
      @solarfacts4242  ปีที่แล้ว

      Ooh sorry

    • @InderjitSingh-AtwalSolarWorks
      @InderjitSingh-AtwalSolarWorks 23 วันที่ผ่านมา

      ​@@GurbaniGyandharaShare ur phone number

  • @TheOneRock770
    @TheOneRock770 9 หลายเดือนก่อน

    Sirji, is video mein off-grid system ki jagah normal battery powered inverter use karke on-grid system ko chala sakte hai ?

  • @masdeepsingh7806
    @masdeepsingh7806 ปีที่แล้ว +1

    What will happen when the grid becomes available again?
    Will the ongrid inverter automatically start getting refrence voltage from grid or is there any instrument needed to switch between offgrid inverter and the Grid

    • @solarfacts4242
      @solarfacts4242  ปีที่แล้ว

      That automatic function can be done

    • @solarfacts4242
      @solarfacts4242  ปีที่แล้ว

      Also for such kind of solution we have come up with a inverter where you can direct run your load with Solar no grid no Battery required both are optional
      - बिना बैटरी बिना बिजली, सीधे सोलर पर चलेगा ए.सी., फ्रीज, कूलर, पंखा, आपके घर का पूरा लोड I live Demo.
      th-cam.com/video/eMQCGnxjacg/w-d-xo.html

  • @vaibhavpurwar316
    @vaibhavpurwar316 5 วันที่ผ่านมา

    Single phase par bhi explain kare..

  • @dlpme2005
    @dlpme2005 หลายเดือนก่อน

    Kya mai ongrid system me xtra inverter and battery laga sakta hu for night power cut? Is it possible?

  • @Smart_invest007
    @Smart_invest007 หลายเดือนก่อน

    Acha ye batao
    Jo ye solar ki main grid line Alag hoti hai general transformer bali line se.??

  • @VickyJoshiIndian
    @VickyJoshiIndian 2 ปีที่แล้ว +1

    RYB Teeno Phase k Minimum load 9kw k According Device Set karne k baad Jis phase ka load 9kw h usme Consumption kam ho jaata h ya zero ho jata h tab kaise manage hota h... Device m phases ka load whichever is lower load k According hi set hota hoga na...

    • @solarfacts4242
      @solarfacts4242  2 ปีที่แล้ว

      There will be a minimum load set value to run this system

  • @ravidutta3534
    @ravidutta3534 ปีที่แล้ว +1

    It seems a viable option for using grid connected system where grid is not available and a D.G. - PV synchronization becomes essential. You have used a 6 KW offgrid system to power a 30 KW on grid setup. In case we have a 300 KW grid connected set up to provide for a 225 KW load, What would be the size of the the off grid system. What formula will apply

    • @solarfacts4242
      @solarfacts4242  ปีที่แล้ว

      Size could be anything sir
      Only you have to make sure that the reference device I mean offgrid system should not be overloaded this this case if your solar power goes down your appliances will be trip

    • @solarfacts4242
      @solarfacts4242  ปีที่แล้ว +1

      Also for such kind of solution we have come up with a inverter where you can direct run your load with Solar no grid no Battery required both are optional
      - बिना बैटरी बिना बिजली, सीधे सोलर पर चलेगा ए.सी., फ्रीज, कूलर, पंखा, आपके घर का पूरा लोड I live Demo.
      th-cam.com/video/eMQCGnxjacg/w-d-xo.html

  • @JaiHanuman9936
    @JaiHanuman9936 29 วันที่ผ่านมา

    If we have 3kw ongrid system and in emergency we are using 5kw load then what will happen

  • @RajeshPatel-jq8sd
    @RajeshPatel-jq8sd 4 หลายเดือนก่อน

    Zero export se only without netmiter work krega but canection digram bna ke dikawo

  • @SajjadAhmed-jk2dd
    @SajjadAhmed-jk2dd 3 หลายเดือนก่อน

    Bhai, zuberdust.
    pl. Guide, how to use on grid inverter as off grid inverter.

  • @ramkhelawantanti9293
    @ramkhelawantanti9293 5 หลายเดือนก่อน

    Kya DC ko AC me badalne par friqwency 50 Hz Bina greed ke nhi banaya ja sakta

  • @jaganmangat1989
    @jaganmangat1989 ปีที่แล้ว +1

    Solar AC module ko ham agar automatic change over ke genset point pr lga denge to kya hoga. Auto changeover ka GEN point grid ke sath connected nhe hai,so may be power supply ajayegi?

    • @solarfacts4242
      @solarfacts4242  ปีที่แล้ว

      No that will Damage because there is no DGPV synchronisation

  • @sumitkaushik1216
    @sumitkaushik1216 2 ปีที่แล้ว +2

    Good Job Raman 👍👍👍

  • @muzzamilahmed4275
    @muzzamilahmed4275 2 ปีที่แล้ว +1

    In case we want to export power when the grid is available so how we can enable/disable zero export or which setting should we set?
    What I understood from the video is that, On grid inverter get prioritised in comparison of off grid inverter to power the load just because of CT on load side.

  • @kavindrayadav9033
    @kavindrayadav9033 4 หลายเดือนก่อน

    Kya unbalancing ki problem single phase system mein bhi Hogi

  • @intek9433
    @intek9433 3 หลายเดือนก่อน

    on grid jo extra power grid ko ja rahi ha, uska india may kya rules han? please guide

  • @siligurisolarstation2310
    @siligurisolarstation2310 ปีที่แล้ว +2

    Very nice 👌

  • @MultiTechEducation4U
    @MultiTechEducation4U 2 ปีที่แล้ว +2

    V.informative

  • @sauravmodak507
    @sauravmodak507 2 ปีที่แล้ว +1

    Thank you so much

  • @merapan1755
    @merapan1755 ปีที่แล้ว +2

    Same video single phase inverter pe banao plz

  • @pradeepsharma104
    @pradeepsharma104 ปีที่แล้ว +1

    नमस्कार , क्या घर के 3 kva के औंनग्रिड सिस्टम को नार्मल इन्वर्टर से सपोर्ट रिफरेंस देकर स्टार्ट कर दिया पर कुल लोड 1500 वाट है और जेनरेशन 3200 वाट 10 पैनल से हो रहा है यूज न कर सकने की स्थिति में एक्स्ट्रा पावर कैसे कंट्रोल करे, क्या चल जाएगा या सिस्टम डैमेज हो सकता है, ज़ीरो सिस्टम क्या चीज है

    • @solarfacts4242
      @solarfacts4242  ปีที่แล้ว

      You can sir but you have to use control device that will control your your on grid system not to generate more than your load

    • @gaur2050
      @gaur2050 22 วันที่ผ่านมา

      ​@@solarfacts4242, for single phase system, how we can use load control device. Please response.

  • @bharatinfotech8861
    @bharatinfotech8861 หลายเดือนก่อน

    Tokyo 2no system laguna padega?

  • @hasuthar6809
    @hasuthar6809 ปีที่แล้ว +1

    Mere pass 1kw off greed and 3kw on greed single phase both system working hai
    Zero export devish se kaise chalaye
    When greed not available
    Pl. Advice

  • @satishshinde7920
    @satishshinde7920 2 ปีที่แล้ว +1

    Very nice information

  • @debabratabarua4384
    @debabratabarua4384 5 หลายเดือนก่อน

    Is offgrid solar can run factory without grid connection

  • @abdulraoof8138
    @abdulraoof8138 3 หลายเดือนก่อน

    How to connect battery back up with on grid system?

  • @chandraveeryadav9977
    @chandraveeryadav9977 หลายเดือนก่อน

    Extra power se off-grid charging kyo nhi lega??

  • @jigneshpatel-zl1ob
    @jigneshpatel-zl1ob ปีที่แล้ว +1

    Bhai i have 5kw on grid solar system key leyea keet na off grid solar system lagana hogga ?????

  • @dhakedramniwas4375
    @dhakedramniwas4375 4 หลายเดือนก่อน +1

    Mere pass 10 kilowatt Of grade system hai aur 10 kilowatt ka on grid system kya ham aapke bataye hue is method se chala sakte hain kya kyunki hamare gaon ke andar please hamara reply de samay light 24 ghante ka top Ho jaati hai

    • @dhakedramniwas4375
      @dhakedramniwas4375 4 หลายเดือนก่อน +1

      ❤❤❤

    • @sandeepjangir627
      @sandeepjangir627 3 หลายเดือนก่อน +1

      Hybrid inverter lgwa lo

    • @dhakedramniwas4375
      @dhakedramniwas4375 3 หลายเดือนก่อน

      @@sandeepjangir627 th-cam.com/video/tN5dvyBiCpg/w-d-xo.htmlsi=pYeGiilnt181dddO

    • @InderjitSingh-AtwalSolarWorks
      @InderjitSingh-AtwalSolarWorks 23 วันที่ผ่านมา +1

      Yes u can use the both systems on same solar panels for more information share ur phone number

    • @dhakedramniwas4375
      @dhakedramniwas4375 23 วันที่ผ่านมา +1

      th-cam.com/video/tN5dvyBiCpg/w-d-xo.htmlsi=Px7Kzr0ediaZVEKK@@InderjitSingh-AtwalSolarWorks

  • @jayprakashshrimali
    @jayprakashshrimali 2 หลายเดือนก่อน

    एक नॉर्मल घर मैं मान लो 3 केवी का ऑन ग्रिड सिस्टम लगा है और उसको सोलर विदाउट ग्रिड चाहिए मतलब जब ग्रिड का पावर कट हो तभी चाहिए तो क्या करना चाहिए ?
    दूसरी बात मीने अपने घर मे 1000 वाट का ऑफ ग्रिड सिस्टम लगाया है 1000 वाट के सोलर पेनल लगा के रखे है बट मेरा यूसेज सिर 500वाट का है तो जो एक्सेस पावर है उसको अगर ग्रिड मैं देना है तो क्या ये पॉसिबल है ??

  • @gursharansingh2911
    @gursharansingh2911 2 ปีที่แล้ว +1

    Hello 👋 sir app 2 ja 3kw k inverter pe vi ik video banao please

  • @logarhlandu2538
    @logarhlandu2538 4 หลายเดือนก่อน

    what if i have single phase

  • @aamirawan2720
    @aamirawan2720 ปีที่แล้ว

    Thanks sir good job

  • @asmatullah-zx1oi
    @asmatullah-zx1oi 3 หลายเดือนก่อน

    Sir ap on Grid inverter ka sath load pr off grid inverter ko frequency ko synchronize kasa kran gy . frequency different ho ge off grid ke or ON Grid ke?

    • @dhakedramniwas4375
      @dhakedramniwas4375 3 หลายเดือนก่อน

      @@asmatullah-zx1oi th-cam.com/video/tN5dvyBiCpg/w-d-xo.htmlsi=pYeGiilnt181dddO

    • @dhakedramniwas4375
      @dhakedramniwas4375 3 หลายเดือนก่อน

      @@asmatullah-zx1oi th-cam.com/video/tN5dvyBiCpg/w-d-xo.htmlsi=pYeGiilnt181dddO

  • @rpverma7455
    @rpverma7455 6 หลายเดือนก่อน

    Reverse voltage kese de do ge off grid ko ap ku off grid ki output se ongrid on kya ha ap ne

  • @avinash.gkp9383
    @avinash.gkp9383 ปีที่แล้ว

    Thank you very much sir🙏

  • @sheelkumarm
    @sheelkumarm 7 หลายเดือนก่อน +1

    Sir,
    Mujhe on grid system ko hybrid system me convert karna hai. Mere pass idea bhi hai. Kya aapse contact karke discuss kar sakta hu kya?

  • @hemensingla1398
    @hemensingla1398 5 หลายเดือนก่อน

    Nice info

  • @siddheshraut9827
    @siddheshraut9827 2 ปีที่แล้ว +1

    I have inverter at home with battery i am planning for on grid system ,can i use my existing inverter to give reference voltage and frequency to on grid system and then use zero export device ,so that i can use my on grid system when there is power outage as well ,can this work how can I implement

    • @solarfacts4242
      @solarfacts4242  2 ปีที่แล้ว +1

      Yes you can

    • @solarfacts4242
      @solarfacts4242  2 ปีที่แล้ว +1

      Logic will be same

    • @siddheshraut9827
      @siddheshraut9827 2 ปีที่แล้ว +1

      Thankyou very much for the reply ,Sir i have small one more question that is suppose I have power outage and i am using my system on ZED can my 3KW PLANT take the instantaneous load of appliances like mixer ,ac, induction stove as thier starting current is very high ,can solar generate and give that much of power to start the devices or will it keep triping ,keeping condition it is full sunny day and noon 12 pm

    • @solarfacts4242
      @solarfacts4242  2 ปีที่แล้ว

      Yes that can be managed by VFD

    • @solarfacts4242
      @solarfacts4242  2 ปีที่แล้ว

      But proper sunlight required

  • @praveenb3369
    @praveenb3369 2 หลายเดือนก่อน

    Can we run enphase ON GRID WITH zero export enabled

    • @optimusprime0299
      @optimusprime0299 2 หลายเดือนก่อน

      Yes you will need 2 CTs and grid supply for that to work

  • @gursharansingh2911
    @gursharansingh2911 2 ปีที่แล้ว +1

    Mare pass off grid laga h 2kw ka kea muje on grid vi same 2kw he lana chahea

    • @solarfacts4242
      @solarfacts4242  2 ปีที่แล้ว

      this will be good if the capacity is same

  • @harikrishnankr9150
    @harikrishnankr9150 2 ปีที่แล้ว +1

    Good concept

  • @RajeshPatel-jq8sd
    @RajeshPatel-jq8sd 4 หลายเดือนก่อน

    Wiring diagram kaise hoga load, ongrid, offgrid ka

  • @dr.ravindramalagi1204
    @dr.ravindramalagi1204 ปีที่แล้ว

    How to design a offgrid solar system for a 3KW single phase ongrid system. Please suggest sir

  • @YaasirRashid
    @YaasirRashid 9 หลายเดือนก่อน

    What about single phase 5 kw ??

  • @rdd8101
    @rdd8101 ปีที่แล้ว +1

    Can you share any live examples or your project on the same

    • @solarfacts4242
      @solarfacts4242  ปีที่แล้ว +1

      Our customers has done this.
      Right now I don’t have video but yes I will make a video when ever I have time

    • @LUCIFER32ful
      @LUCIFER32ful ปีที่แล้ว

      @@solarfacts4242 please upload a live demonstration

    • @hrishikeshpatel1611
      @hrishikeshpatel1611 ปีที่แล้ว

      @@solarfacts4242 video on the above please for single phase

  • @elseif7620
    @elseif7620 2 ปีที่แล้ว +1

    Sir single phase per bhi year rules apply hoga

  • @vikkyyadav8993
    @vikkyyadav8993 ปีที่แล้ว

    Bhai muje bhi Ongrid system Lagana hai lekin power cut thoda Jada hai. To without grid kaise use kar sakte hai day time me

  • @dev.meghraj
    @dev.meghraj 3 หลายเดือนก่อน

    enphase guys said warranty will be void for this setup and enphase don't support it.
    has anyone successfully run enphase inverters with battery powered inverter for grid replacement.
    can you anyone share references for enphase system and it is safe?

    • @optimusprime0299
      @optimusprime0299 2 หลายเดือนก่อน

      It's true and I have talked to them they will soon launch sunlight backup in the future for IQ 8 series of inverter then only you can use solar power in the day even when grid power is cut. You will also required system controller that they will launch in future.

  • @ukseyousaf
    @ukseyousaf 2 ปีที่แล้ว +2

    What if there is no load on a phase, then zero export will make it zero on all phases ??? then How offgrid inverter will provide the supply ....... it will also trip????

    • @solarfacts4242
      @solarfacts4242  2 ปีที่แล้ว +1

      That you have to maintain actually

    • @solarfacts4242
      @solarfacts4242  2 ปีที่แล้ว +1

      We will divide the load in such a manner so that we can get the minimum load on each phase

    • @solarfacts4242
      @solarfacts4242  2 ปีที่แล้ว +1

      Also we will set if load value is more then the offgrid capacity we will trip offgrid.
      Offgrid trip will cause ongrid trip

  • @RiyaSharma-zg1ht
    @RiyaSharma-zg1ht 2 ปีที่แล้ว +2

    Sir. What is DGPD

    • @solarfacts4242
      @solarfacts4242  2 ปีที่แล้ว +1

      When we connect Solar and PV together then it is call DGPV

  • @MrKhabbu
    @MrKhabbu 3 หลายเดือนก่อน

    Zero export ki Bajay battery ko charge karo

  • @sunshinesolarenergy
    @sunshinesolarenergy ปีที่แล้ว

    Have you practically run this combination

  • @dadusteelindustry16
    @dadusteelindustry16 2 ปีที่แล้ว +1

    Pls tell me snyc genset with solar ongrid inverter

  • @SureshChaudhary-qv3uf
    @SureshChaudhary-qv3uf 2 ปีที่แล้ว

    Ek off grid 5 kva utl pcu ko transformer less pcu kaise bana sakte h.. please

    • @solarfacts4242
      @solarfacts4242  2 ปีที่แล้ว

      WHY YOU WANT TO MAKE IT TRANSFORMER LESS ?

  • @arifuzzamanarif4534
    @arifuzzamanarif4534 ปีที่แล้ว

    Beyond Compare Bro...

  • @jayawantbavaskar9369
    @jayawantbavaskar9369 ปีที่แล้ว

    U can use transformer at load end, so u can run unbalance load easily

    • @solarfacts4242
      @solarfacts4242  ปีที่แล้ว

      we can run but problem is generation from solar system

    • @YaasirRashid
      @YaasirRashid 9 หลายเดือนก่อน

      ​@@solarfacts4242 to stop excess generation we will use ct ??

  • @gursharansingh2911
    @gursharansingh2911 2 ปีที่แล้ว +1

    Hello 👋 sir please app aisa he same single face on grid off grid ka video bane kase chalae on grid ko off grid k sath

  • @VikasKumar-xb6mg
    @VikasKumar-xb6mg ปีที่แล้ว +1

    Mere ghar m metre nhi laga hai. Kya me solar lagva sakta hu?

    • @solarfacts4242
      @solarfacts4242  ปีที่แล้ว

      Aap laga rakhe hai per offgrid hi lagega

  • @yatendrasingh4759
    @yatendrasingh4759 7 หลายเดือนก่อน

    Thodi der ke liye on grid inverter ki jagah hybrid inverter lga do

  • @ImranKhan-bd7sg
    @ImranKhan-bd7sg ปีที่แล้ว +1

    Singal phase me to koi dikat nahi hongi laod balance karne ki

  • @iqbalahmed5612
    @iqbalahmed5612 ปีที่แล้ว +1

    Sir ji ongrid day time me power supply band hone per solar bhi band ho jata hai. Genset chalana padta hai.
    Us waqt direct solar power bina Genset ke kaise use kar sakte hain. Pl. Explain kijiye

  • @Arvindkumarooftopexpert
    @Arvindkumarooftopexpert 5 หลายเดือนก่อน

    100 kwp solar on grid system ko chalane ke liye kitne KVa ka DG ya Kitne kilo watt ka solar lagana hoga.

  • @neutral6778
    @neutral6778 2 ปีที่แล้ว

    Load unbalancing kaise find out kaise kare please suggest

    • @solarfacts4242
      @solarfacts4242  2 ปีที่แล้ว

      by reading the current on all the phases

  • @gursharansingh2911
    @gursharansingh2911 2 ปีที่แล้ว +1

    App 2 kw 3 or4 or 5 kw ke bare me vi batae laken DG k sath nahe

  • @Parisoniofficial
    @Parisoniofficial 2 ปีที่แล้ว +2

    Surat का मंचूरियन याद है भाई

  • @haseebpv2972
    @haseebpv2972 ปีที่แล้ว

    Use enphase on grid inverter

  • @minujha8214
    @minujha8214 2 ปีที่แล้ว +1

    👍👍👍👍👍

  • @dadusteelindustry16
    @dadusteelindustry16 2 ปีที่แล้ว +1

    Kya aap ne precticaly kr ke dekha hai

  • @gursharansingh2911
    @gursharansingh2911 2 ปีที่แล้ว

    Hello 👋 sir app ka praktical video nahe aea abi tak singl face pe

  • @gursharansingh2911
    @gursharansingh2911 2 ปีที่แล้ว +1

    Hello 👋 sir app ke Sabi video only big project ke he h fir hum logo ko aise video dakhne ka kea faida

    • @solarfacts4242
      @solarfacts4242  2 ปีที่แล้ว

      No worry will try to make simple videos on technology

  • @bhanwarlaldukhadiya8663
    @bhanwarlaldukhadiya8663 10 หลายเดือนก่อน

    मुझे ऐसा सिस्टम घर पर लगवाना क्या करू गाइडकरे

  • @dinesh3735
    @dinesh3735 2 ปีที่แล้ว +1

    Aap isko practical bhi kro aur uska video banao

  • @VickyJoshiIndian
    @VickyJoshiIndian 2 ปีที่แล้ว +1

    Zero Export Device Kaha lagana hota h... Solar Meter se Just Pehle ya kahi Aur...

    • @solarfacts4242
      @solarfacts4242  2 ปีที่แล้ว

      Offgrid ki line ke pass

    • @gursharansingh2911
      @gursharansingh2911 2 ปีที่แล้ว

      @@solarfacts4242 out put me ja in put me or 0 export on grid inverter pe vi lagana hoga kea

  • @ravidutta3534
    @ravidutta3534 ปีที่แล้ว +1

    correction grid connected system capacity 30 KW not 50 KW. Typo error

  • @satinderbirmaan8571
    @satinderbirmaan8571 2 ปีที่แล้ว +1

    Plant di video daso

  • @sanjeevsingh9376
    @sanjeevsingh9376 6 หลายเดือนก่อน

    Nahi chalega ap k hisab se off gride inverter ki capacity to hona chaiye loaded ko chalane k liye

    • @solarfacts4242
      @solarfacts4242  6 หลายเดือนก่อน

      Sahab chal raha hai mera

    • @solarfacts4242
      @solarfacts4242  6 หลายเดือนก่อน +1

      Also if you check one person has also commented that he is running his system

  • @nawab9317
    @nawab9317 ปีที่แล้ว +1

    सर आपके पास कोई बंदा ऐसा हो जिससे ऑन ग्रिड सिस्टम को उसका मुझे नंबर दीजिए

    • @solarfacts4242
      @solarfacts4242  ปีที่แล้ว

      Please let me know what you want to do ?

  • @rohitkdel
    @rohitkdel 3 หลายเดือนก่อน

    Hybrid lagao na bhai...kya bakiti hai.....double panels kyu jagana..... off-grid wala damage hona he hai ...coz we can't control load.....and loads are not constant

    • @solarfacts4242
      @solarfacts4242  3 หลายเดือนก่อน

      Bakiti kuch Ese hai sir ki ham isko control logic se chala rahe hai oor aap ne 1 min me hybrid bol diya oor han lage hue plant ne bina kharcha kiye usko use karne hi baat kar rahe

    • @optimusprime0299
      @optimusprime0299 2 หลายเดือนก่อน

      Hybrid is still in it's initial phase in india and most of the inveters available are Chinese imported products with questionable reliability and quality of service in future ​@@solarfacts4242

  • @parmindersingh9173
    @parmindersingh9173 ปีที่แล้ว +1

    Only theory, will not work practically. Instead of using two systems use hybrid solar system that is already available in the market.

    • @solarfacts4242
      @solarfacts4242  ปีที่แล้ว

      This is working sir and this is for the customers who have ongrid system and wants to Use as offgrid

    • @dpchoudhary12
      @dpchoudhary12 ปีที่แล้ว

      हाइब्रिड इनवर्टर सोलर की जनरेशन 25% कम कर देता है

  • @rajanikantrai7245
    @rajanikantrai7245 ปีที่แล้ว +1

    If only single Fase on grid ho

  • @gopaljee5257
    @gopaljee5257 2 ปีที่แล้ว

    सर आप से मुझे सोलर हेल्प चाहिए । आप से कैसे कनेक्ट हो सकते है। प्ल्ज़ responce

    • @solarfacts4242
      @solarfacts4242  2 ปีที่แล้ว

      by WhatsApp
      I have given my number in description

  • @ramkalapad7118
    @ramkalapad7118 2 ปีที่แล้ว +1

    Are available 6kw off grid inverter