Surge Protection Device (SPD) Installation and Operation / in Sinhala / Engineering Technology A/L
ฝัง
- เผยแพร่เมื่อ 24 ก.ย. 2021
- How to install a #Surge_Protection_Device.
How #surge_protection devices work.
An #SPD is to be installed on to an electrical circuit, and is for the #Electrical_safety of the equipment, mainly from voltage spikes.
These are mainly designed to protect against transient voltage surges that appear and disappear in just a few microseconds.
Although the duration of these spikes are very short, large single surge events such as lightning strikes, can reach hundreds of thousands of volts and can cause immediate damage to the equipment.
However, #lightning strikes account only for around 20% of total transient surge activities.
Remaining 80% of surges occur internally, when a motor starts or some other supply line fault outside of human control.
Although these surges can be of smaller in magnitude, with a higher frequency of occurrence, and with continued exposure, they can degrade sensitive electronic equipment within the circuit.
Installation of an SPD on to an electrical panel board is explained here with simple but explanatory animation work.
Description of the internal parts of an SPD and how they work together to arrest transient surges quickly, are very well explained here in this video.
If this video is useful to you, please subscribe the channel.
Thank you.
#engineering_technology
#surgeprotector #house_wiring #board_wiring #electrical_wiring #lightening_arrester #electricalengineering #3_phase_wiring
ප්රශ්නයක් ඇසීමට අවශ්ය නොවන තරමටම හරිම නිරවුල් පැහැදිලි කිරීමක්.
ස්තුතියි
Thank you 👍
Db එකට SPD දාන්න එපා.. .මණ්ඩලෙන් මීටරයට දාන C32 එකෙන් පස්සෙ ගෙදර DB එකට කලින් SPD එක දාන්න.. එතකොට ප්රොටෙක්ෂන් එක වැඩියි.. අනික කොහොමත් SPD එකේ අර්ත් එක ගෙදර අර්ත් එක එක්ක දාන්න එපා ඕවර් ලෝර්ඩ් එකක් ආවොත් SPD එක හරහා ග්රවුන්ඩ් වෙන ගමන්ම අනෙක් අර්ත් එකෙන් ගෙට යන්න පුලුවන්.. අර්ත් රොඩ් දෙක අතර මීටර් 5/6 ක් වත් පරතරය තියලා සවිකරගන්න ඕන.
Good
good job
dont use earth bar.. connect separate
නියමයි ඔබතුමා ඉලෙක්ට්රිකල් ඉලෙක්ට්රොනික් දෙකෙන්ම කියල දෙනව
Thanks මල්ලි මම කලින් මේක දැකල නැහැ ඔය හොද නිර්වචනයක් කලා බොහෝම ස්තුතියි
Thank you 👍
ඔබ තුමාගෙන් මෙවැනි තව වීඩියෝ බලාපොරොත්තු වෙනවා ස්තුතී
Thank you 👍
Clear explanation. Thank you for your valuable time
Thank you 👍
ස්තුතියි හොඳ පැහැදිලි කිරිමත් එක්කලා. මෙහි සාමාන්ය පවතින වත්මන් මිල ගනන් ගැනත් දැනගැනීම හැකිනම් උදව්වක්..
Thank you.
ගණන් බලාගන්න නම් "SPD price in Sri Lanka" ටයිප් කරලා, ඉන්ටෙර්නෙට් ගිහින් සර්ච කරල දැනගන්න පුළුවන්.
very good in detail explanation .Thank you sir...
Thank you 👍
lot of thank's for u.jaya weewa.
Thank you 👍
Very clear 👌 explanations sir. 😊 thanks for sharing
Thank you 👍
දැනුම බෙදා දීමේදී ඔබ ගුරුවරයා ගේ කාර්ය් භාරය මැනවින් ඉටු කරනවා .......... පැහැදිලි සහ නිරවුල්ව
Thank you 👍
Great explanation. Thank you😊😊
Thank you 👍
Very well correctly explained
Thank you 👍
Thanking you about ur valuable time.
Thank you 👍
Godak watinawa thanks
Thank you 👍
Very informative
Thanks
Thank you 👍
Very good explanation.... Good job... Thank you.
Thank you 👍
Good explain .thanks
Thank you 👍
Thanks brother
Thank you 👍
Excellent ... tks a lot
Thank you 👍
thank you sir.. good explanation.
Thank you 👍
Very good cler explanation.
Thank you 👍
Thank you very much....
Thank you 👍
Thanku supiri supiri
Thank you 👍
Thanks 👍
Thank you 👍
Good 👍
Thank you 👍
ඉතාමත් හොඳ ගුරුවරයෙක්,
Thank you 👍
meka waradi.erth 1 wenama denna one,natham therumak naha
Good job sr👍👍👍
Thank you 👍
Good explanation 👍
Thank you 👍
Good lesson tanks
Thank you
thanks.
Thank you 👍
හොඳ පැහැදිලි කිරීමක්
Thank you 👍
ස්තුතියි
Thank you 👍
👌...
Thank you 👍
Niyama guruwaru
Thank you 👍
Thank you so much for this great video...
Thank you 👍
Earth rod 2k danna hondada ekam circuit ekata?(step potential )bonded ground neda one?
👍
Thank you 👍
ithamath hodai
Thank you
Sir akunu gahanakota trip eke offwenavanum trip eka doshayakda
Single pase line ehekata
32Ak neda puluwan ,ethakota 32A wada ekathu kaloth beker ganana api kiyamuko
16A
10A
10A
Ekathuwa 36A ehema agayak ekthu kaloth weradida prashnayak wenawada
harima pehediwa denawa hoda wedak jawewa
Thank you 👍
Spd thibune nathi unoth loku surge ekak awoth wenna puluwan de equipments pichchena eka witari neda?
👍❤
Thank you 👍
Main switch ekata isslla hi karanan wadaath hoday
🙏🙏🙏❤️
Thank you 👍
Spd eka db eka atule savi karana eka nam awadaanam neda.wenama box ekak atule savi karanna ona
house wiring video series ekak karanna pls..
Ok. Karannanm.
Mage spd aka 385V dala thiyenne sir aka hari nam 275V neda wenna ona.
Line 2k set kara video ekak danna puluwada
Auto electric වල ඒවත් පුලුවන්නම් කරන්න සර්..🙏
Uc 460v SPD එක කමක් නැද්ද?
Spd 1k surge 1ki පස්සේ පොඩි ground leak 1 awoth off වෙන්ඩ තැනක් ne neda.....rcd 1n පස්සේ දැම්මොත් ඒ leak 1 detect වෙනවා නේද?
is it better to have a over current protector before the SPD? Please let me know.
Over current protectors are not quick enough to detect transient voltage spikes, appear and disappear within few microseconds.
So it can go after the SPD.
සුබ අලුත් අවුරුද්දක් වේවා ... Spd එකක් මිලදී ගන්න විට voltage එක කියක එකක්ද ගන්න ඕනෑද sir ?
සුබ අලුත් අවුරුද්දක් වේවා.!
V RMS අගය 230 volts නිසා, V max හෙවත් උපරිම අගය වෙන්නෙ 325 volts.
ඒකට 10-15% විතර වැඩි අගයක් SPD එකේ තියෙන්න ඕන.
375 - 385 V වගේ අගයක් තියෙනවා නම් තමයි හොඳ.
Meka karanna apa spd eka cb eka laga danna
60A 3phase supply ekakata danna ona spd eke saha fuse wala agayan kiyada.
Uc= 385 V, In= 20kA, Imax=40kA SPD ekak athi. 40 Amp HRC fuse 3 k SPD line 3 ta daana.
Aeka daane SPD eka fail wela athulen short unoth, short circuit current eken load eka paththa parissam karagannai.
Suba dawasak. Oyage videos valin loku danumak labuwa. Tnx. Oben danaganna yamak thiyanawa. Mage niwase kotas 3 ta board 3 k thiyanawa. Mee hama ekeema. Main and trip switches thiyanawa. Main line eka loop karala thiyenne. Meeka ok da? Nathnam 1st main board eken anith bordswala breakers walata loop karanna phuluwanda? Distribution boards athara dura 10m wage thiyanawa. Obagen pilithurak balaporotthu wenawa. Tnx
Main eke input eken loop kalata prashnayak naha, venama trip switch daala thiyenawanam.
Palamuweni kotasa sita deweni kotasata daala thiyena wire eka, deweni thunweni kotas wala load ekathuwata hariyana size wenna ona.
Palaweni gedarata daapu wire eka CEB hari LECO harine daala aththe.
Aeka, kotas thunema load ekata hariyana size wenna ona.
Electrician kenekta kiyala, load walata hariyana wire da kiyala balawaganna.
Ok. 👍 Tnx
@@TechTipsEngineering Mma Breakers okkoma C 10 walin damma. Water motor ekata vitharak C16 damma ok da?
මේන් ස්විච් එක වෙනුවට චේන්ජෝවර් එකක් දාන්න බැරි ද
digatama vidieo karanna asai denaganna
Thank you 👍
spd eka earth wayr ekai mcb bood eka earth wayr. Ekama thanata polawata samabanda karan one da e daka wanama samabanda karata gataluwak nadda. Pahadila karala denko ❤
Earth wire wenama sambanda kalata kamak naha.
Ekata sambanda karanawanam, DB eken ena earth wire eka, video eke kiyala thiyena size ekata wadiya aduwenna baha.
earth bata deka adi 18k wage durakim dawata wana wanam kamak na neda
Sir main switch එකේ යටින් Nutrel Bar එකද තියෙන්න ඕන Earth එකද.. අපේ ගෙදර Main එක yatama Earth එක තියෙන්නේ
ඒක ප්රශ්නයක් නැහැ.
සාමාන්යයෙන් neutral bar එක දිගටත්, earth bar එක ඊට ටිකක් කොටටත් තමයි එන්නෙ.
Sir What software tools do you use to practice Animation?
Powerpoint animation
@@TechTipsEngineering Thanks sir 👍
I have wired as exactly your diagram. With a new dedicated earth rod. But lighting still passes to the trip and when lighting, it trips. How to solve it?
Actually RCD (or Trip switch) is made to protect people getting electric shock.
It trips off when detect a very small current difference of 30 mA (0.03 Amps) or less between phase and Neutral wires.
(Please watch my video on trip switch testing).
During lightning also, there can be very short period current differences induced between outdoor power lines making RCD on a DB to trip off.
SPD will not operate for that much small current differences between power lines.
@@TechTipsEngineering thank you for the very clear explanation. So wat is the solution to have more tolerance for the rcd when there's the small surge's via lightning?
Therum ganimata pahasu vidiyata pahadili karala thiyanawa sir
Thank you 👍
Tellicommunication walata use karanna wnnama SPD thiyanawada
Main switch board ekata daanne Type 1 SPD ekak.
Equipment pramanaya wadinam Sub- switch board thiyeyi ne.
Ethanadi Sub- switch board walata Type 2 SPD enna ona.
Thawa amtharawa Telephone system, CCTV system saha PLC system ehema thiyeyi nam,
samanyayen ae place walata Type 3 SPD daanna ona.
SPD එකේ Earth එක DB Board එකේ Earth එකට Connect කරන නිසා අකුණක් ගහද්දි ඒ ව්දුලිය DB එකෙන් රිටන් වෙලා උපකරණ පිච්චෙන්නේ නැද්ද
DB එකෙන් වර්ග මිලිමීටර් 10ක වත් earth wire එකක් Direct පොලොවට සවි කරල නැත්නම්, SPD එක වෙනම earth කරගන්න ඕන 10 sq.mm වයර් එකකින්.
අනිත් උපකරණ DB එකේ earth එකට සවිකරන්නෙ බොහෝ විට පොඩි earth wire එකකින් නිසා ලොකු වයර් එකෙන් තමයි බහින්නෙ.
කොහොම උනත් SPD එක වෙනම earth කරගන්න එක තමයි සුදුසු.
බොහෝම ස්තුති මහත්මයා 🙏🙏🙏මහත්මයා SPD එකක් සවිඉ කිරිමෙදි fuse වෙනුවට mcb/mccb එකක් සවිඉ කිරිම සුදුසුද? ස්තුති 🙏
3-phase 63A 3-pole MCB එකක් වගේ දාන්න වෙනවා fuse වෙනුවට නම්.
Fuse දාන්නෙ ලොකු ව්දුලි කෙටීමකදී SPD එක ඇතුලෙන් 3-phase short වෙලා ගිනි ගන්න උනත් පුලුවන් නිසායි.
Breaker කෑලි තුනක් දාල තිබුනොත් කවුරු හරි දන්නෙ නැතිව ඒ වෙලාවෙදි on කරන්නත් ඉඩ තියෙනවා. Fuse ම දාන්නෙ ඒකයි.
Single phase SPD එකට fuse මොනවත් ඕනෙ නැහැ.
@@TechTipsEngineering බොහෝම ස්තුති මහත්මයා 🙏❤️
Suba dawasak. Oyage videos valin loku danumak labuwa. Tnx. Oben danaganna yamak thiyanawa. Mage niwase kotas 3 ta board 3 k thiyanawa. Mee hama ekeema. Main and trip switches thiyanawa. Main line eka loop karala thiyenne. Meeka ok da? Nathnam 1st main board eken anith bordswala breakers walata loop karanna phuluwanda? Distribution boards athara dura 10m wage thiyanawa. Obagen pilithurak balaporotthu wenawa. Tnx
Spd එක db එක ඇතුලේ දන්නේ නැතුව main switch එකට කලින් දාලා වෙනම earth එකක් ගහලා දැම්මොත් තවත් හොඳයි නේද
එස්පීඩී එකේ අර්ත් එක වෙනම දානවානම් ඩීබී එකේ අර්ත් එකට තිබිය යුතු දුරක් තිබේද ඒ කොපමනද
Earth rod එකක අවම දිග අඩි 8 ක් වෙන්න ඕන.
ඒක තමයි standard එක.
Earth rod දෙකක් අතර පරතරයත් අඩි 8ක් වත් වෙන්න ඕන.
අවමය ඒක.
ඊට වැඩියෙන් තිබුනට ප්රශ්නයක් නැහැ.
අනිවාර්යයෙන්ම spd එකේ අර්ත් එක වෙනම දාන්නම ඕන නේද.
අනිවාර්ය නැහැ.
Earthing system එකේ wire sizes, video එකේ කියල තියෙන විදියට තියෙයි නම් ඒකට connect කලාට ප්රශ්නයක් නැහැ.
Wire sizes මදි නම් වෙනම connect කරන්න වෙනවා.
SPD manufacturer companies recommend කරන්නෙ එහෙමයි.
Meka gedara savikarala pichchunoth kohomada balaganne
Kola patata thiyena screen eka rathu pata wenawa.
@@TechTipsEngineering aye on kara ganne kohomada aluthin ekak danna onada sir,
සර් මෙි spd එක මෙින් එකට පෙර සවි කලොත් දවුලක්ද? 🙏 ස්තුති😍
මේන් එකට කලින් සවි කලොත් SPD එක ෂෝට් උන වෙලාවකට ඒක Bypass කරගන්න බැරි වෙනවා.
Lankawata galapena AC SPD wala voltage eka kiyada ?
V RMS 230 volt. V max wenne 325 volt. Ekata 10-15% withara wadi agayak thamai hoda.
Volt 275-285 wage ganak hari yanawa.
@@TechTipsEngineering a kiyanne AC SPD 275-285V wage ekak damma nam hari ne da ?
@@mygalaxyvideoss ow.
@@TechTipsEngineering
Uc 275V wana saha
Imax hasa In = 60-30
Up 2.0Kv
Uc 275V wana saha
Imax hasa In = 40-20
Up 1.8Kv
Uc 275V wana saha
Imax hasa In = 20-10
Up 1.5Kv
2 pase niwasakata ihatha AC SPD 3 nen wadathma galapenne kumana ekada ?
Plz sir try and explain it in English for me
Please send your email address to me. sudarshan78@gmail.com
SPD ඵක ඵන්න ඕන මේන් ස්විච් එකටත් කලින් 🤔
branded spd wala fuse enawa. cheap spd danna epa me wage ewanam
Fuse walin "Transient voltage surgees" allanna baha.
Voltage spikes athiwena hati danaganna pahala link ekata gihin video eka balanna. th-cam.com/video/PlgRsRtcW8o/w-d-xo.htmlsi=BV2WK-SxJohfdbE5
Type 1 , Type 2 ,Type 3 කියලා කියන්නේ මොකක්ද
Aiye akunu walat ok harid
සර් ව්දුලි කෙටිමකදි ව්දුලිය නිවසෙ ඉහළ යන්නේ පිළිබඳ ව්ස්තර කරන්න පුළුවන්ද
පාරෙ ඇදල තියෙන wire එකට direct විදුලියක් කෙටුවොත්, wire එක දිගේ ගෙදර ඇතුලට එන්න පුලුවන්.
Wire එක කිට්ටුවම විදුලි කෙටුවොත්, transformer එකක වෙනව වගේ මේ පැත්තෙ wire එකට ලොකු ඇම්පියර් ගනනක් පාස් වෙන්න පුලුවන්.
@@TechTipsEngineering thank sir
අකුණු සන්නායකයක් තියෙනවනම් මේ SPD ඒකක සවි කරේ නැතුවාට කමක් නැද්ද
SPD සවිකරන්නෙ පිටින් ඇතුලට එන wire දිගේ එන surge වලින් ආරක්ෂා වෙන්නයි. අකුණු සන්නායකයක් තියෙනව නම් හොඳයි.
SPD එකෙන්, වෙනත් ආකාරයට එන ක්ෂණික voltage සහ current වෙනස්වීම් වලිනුත් ආරක්ෂාව ලැබෙනවා.
SPD එක ට්රිප් ස්විච් එක ට පස්සෙ නේද හයි කරන්නේ ?
Surge එක bypass කරන්නෙ SPD එක.
Trip switch එක protect වෙන්නෙත් SPD එකෙන්.
Main Switch එකටත් කලින් දැම්මොත් තමයි හොඳ.
ඒත් repair එකකදි SPD එක bypass කරගන්න පුලුවන් නිසා තමයි, Main එකට පස්සෙ හයිකරන්නෙ.
සර් ව්ස්තර කිරිම ඉතාමත් හොදයි thank
Thank you 👍
Durability eka kohomada
Loku viduli ketimakadi, SPD eke ampere gananata wadiya current eka ena welawal thiyeyi.
Widuli kotana welawata equipment off karana eka thamai wadath hoda.
Ehema bari unath, bohoma welawata SPD eka damage wela equipment parissam wenawa.
Thank you
නිව්ටල් එක කෑඩුනොත් ආරක්ශාවක් නෑද්ද
මේකෙන් නිවස ඇතුලේ සිදුවෙන Surge වලිනුත් ආරක්ෂාවක් ලැබෙනවාද?
මේකෙන් ආරක්ෂාව ලැබෙන්නේ නිවසට පිටින් ඇතුලට එන surge වලින්.
@@TechTipsEngineering නිවස ඇතුළත නිර්මාණය වන surge වලින් අනෙක් උපකරණ ආරක්ෂා කරන්න හදපු protectors තියෙනවද? (ප්ලග් එකකට ගහන ඒවා හැර මේ වගේ DB එකට සවි කළ හැකි ඒවා)
@@Janakaprd දැන් Whole house surge protectors කියල අලුතින් ඇවිත් තියෙනවා.
මෙහෙත් ඇති.
Online shop වල පොඩ්ඩක් හොයල බලන්න.
මේක කීයක් විතර වෙනවද
Single phase SPD එක 4000-5000 ක් විතර වෙයි.
පහළ Kevilton ලගෙ ලින්ක් එකට ගිහින් බලන්න. kevilton.lk/products_description/spd-2-pole
SPD fix before the Main
Why? Tell the reason.
No aka awanna puluwan da
දැනට වැඩකටයුතු කිහිපයකම නියැලෙන නිසා පෞද්ගලිකව පිලිතුරු ලබාදීමට අපහසුයි.
Translate to Tamil or English please
Please go to below link
th-cam.com/video/d2UC56t0Ux4/w-d-xo.html
කියක් වෙනවාද
Spd එකක්
Single phase SPD එක 4000 -5000 ක් වගේ.
පහළ ලින්ක් එකට (කෙව්ල්ටන්) ගිහින් බලන්න.
kevilton.lk/products_description/spd-2-pole
@@TechTipsEngineering ස්තුතියි
waradi
SPD කියන්නෙ මොකක්ද ඒකෙන් කරන්නෙ මොකක්ද 🙄
SPD කියන්නෙ surge protection device.
මේක හදිසියේ ඇතිවන voltage නැගීම්, line එක හරහා නොයවා, ක්ශනිකව earth එකට මාරු කරන්න හැකියාව තියෙන item එකක්.
This video copied from # Electro Academy TH-cam channel
It is our English Channel. You can view Spanish version also on below link th-cam.com/video/FlCyyYZ-pCg/w-d-xo.html
Mage spd aka 385V dala thiyenne sir aka hari nam 275V neda wenna ona.
Good.good.vary.good