How To Wire A Kitchen - Rough In Electrical Circuit Wiring Guide

แชร์
ฝัง
  • เผยแพร่เมื่อ 26 ก.ย. 2024

ความคิดเห็น • 295

  • @TheExcellentLaborer
    @TheExcellentLaborer  3 ปีที่แล้ว +22

    That was my daughter if you were wondering! Timestamps below...
    Type of outlet box for kitchen outlets: 00:29
    Height to place kitchen outlets: 00:58
    Kitchen Outlets Codes In My Area: 01:36
    How to wire for a refrigerator: 07:15
    How to wire for a microwave: 07:50
    How to wire a dishwasher: 08:41
    How to wire for a range: 09:46
    Overview of the kitchen circuit layout: 10:20
    Outlets almost too far from sink to pass code!: 11:35
    Tour of a kitchen I built in the past: 13:10
    What I use for recessed kitchen lighting: 13:36

    • @lostquartermaster52
      @lostquartermaster52 2 ปีที่แล้ว +1

      What about running from the kitchen to the circuit breaker?

    • @troybush5899
      @troybush5899 ปีที่แล้ว

      #2 should read "WITHIN 24" of the sink" to make it more clear ("from 24" sound like "away from").

  • @nicholasmoore8424
    @nicholasmoore8424 3 ปีที่แล้ว +64

    Just FYI, when you go to buy the breakers, they're called "dual function" breakers. They have GFCI and AFCI breakers, but the AFCI breakers are actually called "combination arc fault". So if you buy the ones that say "combination" on them, they're going to only be AFCI breakers without GFCI protection.

    • @carlodonnell146
      @carlodonnell146 2 ปีที่แล้ว +1

      fair enough but I meant the GFCI receptacles. No one ever seems to mention the danger of plugging medical devices or fridges or anything that shouldn't trip off unexpectedly. So do they have to be installed because it is code regardless of what makes sense?

    • @MarcosGarcia-xg1rf
      @MarcosGarcia-xg1rf 2 ปีที่แล้ว +1

      @@carlodonnell146 regardless of what’s going in it. All new 15/20 amp must be arc fault protected. There are exceptions

    • @Carl-LaFong1618
      @Carl-LaFong1618 9 หลายเดือนก่อน

      @@carlodonnell146 yeah, I had an extra freezer in my garage on a gfi and it tripped and I didn't know it. Food went bad.

    • @JamieHitt
      @JamieHitt 12 ชั่วโมงที่ผ่านมา

      Just to clarify for the folks at home when an arc fault breaker says "combination", it means that it deals with both series and parallel arc faults.

  • @TheAnon232
    @TheAnon232 ปีที่แล้ว +15

    Dude. You’ve become one of my favorite TH-cam channels. You do such a good job of explaining things. 👏

  • @jorgiep09
    @jorgiep09 2 ปีที่แล้ว +10

    This guy teaches the electrician teachers ,,I can't believe I was so afraid of doing electrical work ,right after watching this videos I went straight to installing recesed lights with dimming switches ,,remodel and new cons,,I was even teaching my partner he couldn't belive what he was actually doing it lol 😆 ,,thanks so much great work

  • @PatrickEArchuleta-fs8bv
    @PatrickEArchuleta-fs8bv 7 หลายเดือนก่อน +2

    Thanks for refreshing my memory, outstanding work second to none,may Almighty God continue to bless you and your work, family ❤😊

  • @MrNanah38
    @MrNanah38 2 ปีที่แล้ว +16

    I am thinking of building my own home, and I ran across your channel, you make it so simple, it seem intimidating at first but if I had a buddy like you at my side it would be a cake.

    • @gavinnewscum
      @gavinnewscum 2 ปีที่แล้ว +5

      It’s a piece of cake but takes a long time to eat

    • @forcedomkombat
      @forcedomkombat ปีที่แล้ว

      @@gavinnewscum ......lol

    • @kylehuberofs8052
      @kylehuberofs8052 5 หลายเดือนก่อน

      I started framing houses when I was 13 and started wiring houses when I was 15. Started doing everything at 25. I mostly take houses down to the studs and remodel now at 35. It's easy if you just start out taking your time and double check everything along the way. Once you've done a few it's a breeze

  • @olk084
    @olk084 6 วันที่ผ่านมา

    Josh, thank you for your videos about thet Stone vineyard on the fire place I did according your knowledge.

  • @jeremymyers5503
    @jeremymyers5503 2 ปีที่แล้ว +9

    Great video. I enjoy all your videos as you are good at explaining everything in layman’s terms so we all can understand.

  • @TheRobWay1
    @TheRobWay1 2 หลายเดือนก่อน

    Licensed electrician here.. I love this video! Great job!!

  • @salfitimina2376
    @salfitimina2376 ปีที่แล้ว +6

    Definitely put a fridge on a dedicated circuit, some new fridges/freezers these days can draw like 12/14 amps alone. The gfci requirement for the fridge has nothing to do with a water source. Its required regardless ( depending on which code year your state is on ) . I have a feeling that requirement will be reversed at some point)
    The microwave above the stove needs to be GFCI ( again depending what code year ) , but in 2023 code, pretty much ANY outlet in kitchen will need to be GFCI, except for the stove.
    Also, if your micro is on the counter , run a dedicated ct to that outlet.
    We run ded ct for each micro; oven hood; coffee makers; trash compactor; fryers; if you have a hot plate for some reason; disp/dish. Also, run a ded if you have an instant hot; plus the 2 required general cts.
    A kitchen alone , especially a new one, can easily have like 7 to 11 cts. Overkill now, no headaches later.

    • @JoesPhenomenal
      @JoesPhenomenal ปีที่แล้ว

      So is it a good idea to just use arc protected and gfci breakers on every circuit for the kitchen including the lighting? If I did that, would I still have to use and gfci recepticles? I was thinking a still needed gfci on my cook top and oven (they are separate and apart from one another, but both are on 240v.

  • @aaudain1
    @aaudain1 ปีที่แล้ว +1

    This is what I like about your Channel you teach us step by step information clearly explain on top of that another license electrician are important that is to me

  • @MikeL-vu7jo
    @MikeL-vu7jo 2 ปีที่แล้ว +4

    Nice work thanks , one thing you could add when explaining the 12 inch rule for the island outlet is that when installing an outlet in a horizontal position always have the wider neutral blade slot in the up position and hot blade slot down , that's so if an appliance is plugged in and works it's way out the neutral is exposed and not the hot blade , thanks again .

    • @grovermccoy5512
      @grovermccoy5512 2 ปีที่แล้ว +2

      THERE IS NO CODE REQUIREMENT FOR THIS.

  • @kennieloo6357
    @kennieloo6357 3 ปีที่แล้ว +3

    Can’t wait for the recessed lighting video. That has been my nemesis to figure out when designing my place. Thanks!

  • @richvail7551
    @richvail7551 5 หลายเดือนก่อน

    Great video, thanks. Even getting just this amount done on my own will save me a handsome amount of cash. I’ll leave the final hooking up process to the professionals but to have it all placed and wires run is time well spent.

  • @chizo5097
    @chizo5097 3 ปีที่แล้ว +4

    good video You explain everything in a very simple way thank you for that

  • @danielphillips5045
    @danielphillips5045 2 หลายเดือนก่อน +1

    Thanks!

  • @T.E.P.
    @T.E.P. 3 ปีที่แล้ว +4

    Superb vid Josh!!! Fantastic info and your channel is indeed EXCELLENT!

    • @TheExcellentLaborer
      @TheExcellentLaborer  3 ปีที่แล้ว +1

      Thank Thor! I’m glad you appreciate my videos. It definitely takes time to make them presentable to an audience and I appreciate you watching them!

  • @Bradley-tx6ed
    @Bradley-tx6ed 2 ปีที่แล้ว +8

    a good tip I learned is to use slider boxes for your countertop outlet rough in, they are rigid plastic boxes as well but when tile is added you can loosen the screws and move your box forward flush with the tile afterwards. I believe they are available at most of your local big box stores

    • @grovermccoy5512
      @grovermccoy5512 2 ปีที่แล้ว

      PERFECT REMEDY FOR WHERE TILE IS ADDED.

    • @dallas5374
      @dallas5374 2 ปีที่แล้ว

      How does it move when there is grout and tile holding it in? Just curious?

    • @Bradley-tx6ed
      @Bradley-tx6ed 2 ปีที่แล้ว +2

      you install the box a couple inches forward past where the finished surface would be. then the grout is only supposed to be in between the tiles not around the box and even if the tile is tight up against the box you can lightly tap the box back flush

  • @dadaszeto833
    @dadaszeto833 2 ปีที่แล้ว +2

    I learned from you more.thanks

  • @upliftadventuresu.s.a1918
    @upliftadventuresu.s.a1918 2 ปีที่แล้ว +6

    Thanks for all your videos! I'm currently building my own cabin and have started on the electric, been learning all from your videos!

    • @shoneythomas9215
      @shoneythomas9215 2 ปีที่แล้ว

      Sir I suggest you if u do follow a licensed electrician it’s 3 circuits refrigeration needs to be by itself but do what you want

  • @edrodriguez3190
    @edrodriguez3190 3 ปีที่แล้ว +2

    Thanks again Josh for the excellent tutorial. 👍

  • @JAM-zb2vh
    @JAM-zb2vh 10 วันที่ผ่านมา

    I love working with a bare bones to do a complete wire job.

  • @JavierLopez-po2dv
    @JavierLopez-po2dv 2 ปีที่แล้ว +3

    My respect and thank you for the excellent videos so well explain and right to the point great videos

    • @TheExcellentLaborer
      @TheExcellentLaborer  2 ปีที่แล้ว

      Thank you for your kind comment. I’ll try to keep my videos simple and educational. Thanks for watching!

  • @cyrusparsaei1441
    @cyrusparsaei1441 2 ปีที่แล้ว +1

    Fantastic clips. so clear and well explanation.

  • @mickdulmage5173
    @mickdulmage5173 3 ปีที่แล้ว +3

    Great video. Love the kitchen outlet 101 list!

  • @terrycaldwell9114
    @terrycaldwell9114 3 ปีที่แล้ว +7

    Again great vid! Will be looking to see 200 panel wiring next, then onto plumbing!

    • @TheExcellentLaborer
      @TheExcellentLaborer  3 ปีที่แล้ว +2

      Hey Terry! Yup the 200 panel video is underway. I want to run most of the wiring so I can show everyone how to wire double breakers and single breakers. Stay tuned and thanks for watching!

    • @michaeltaylorjr9962
      @michaeltaylorjr9962 2 ปีที่แล้ว

      This guy is bout to make us all rich 🤑

  • @scottslotterbeck3796
    @scottslotterbeck3796 ปีที่แล้ว

    What a great way to make a living. I envy you.

  • @rodneyhall1435
    @rodneyhall1435 ปีที่แล้ว +1

    Great video. Lots of useful information.

    • @TheExcellentLaborer
      @TheExcellentLaborer  ปีที่แล้ว

      Thanks Rodney! I try to pack as much information into each one of my videos. Take care!

  • @yuhriandraikou2024
    @yuhriandraikou2024 ปีที่แล้ว

    i like your videos i want to learn how to learn elctricity

  • @stevediep4328
    @stevediep4328 2 ปีที่แล้ว +5

    Fridge doesn't have to be dedicated circuit. Can be on a small appliance circuit

  • @randypaul5427
    @randypaul5427 3 ปีที่แล้ว +3

    Great video!

  • @vikramsinh566
    @vikramsinh566 20 วันที่ผ่านมา

    Nice i M indian electricion hous 🇮🇳🇮🇳🇮🇳🇮🇳🇮🇳🇮🇳🇮🇳

  • @ronaldoleksy8264
    @ronaldoleksy8264 ปีที่แล้ว

    I like an was taught to alternative outlets A -B -A. An so on Nice to use Ark fault breakers an GFI in the kitchen. That way when an if its trips. More convenient for the homeowner to reset

  • @bigtime37ja
    @bigtime37ja 3 ปีที่แล้ว +1

    Really enjoy your videos. A wealth of info and entertaining too. THANKS

    • @TheExcellentLaborer
      @TheExcellentLaborer  3 ปีที่แล้ว

      Thanks a lot Jerry! Thanks a lot for watching. You are welcome!

  • @tuyentran3456
    @tuyentran3456 ปีที่แล้ว

    Respect u a damn good teacher

  • @tonyfinck8024
    @tonyfinck8024 2 ปีที่แล้ว

    Thanks for the knowledge. I'll be doing the same thing soon and I hope to find a really good Master Electrician to pull the permit

  • @bobniles1928
    @bobniles1928 ปีที่แล้ว

    For a DW and disposal install a 20 amp receptacle in the sink base. This also provides the required disconnect.

  • @jacobkelso9867
    @jacobkelso9867 2 ปีที่แล้ว +1

    I need a vid on installing a kitchen sink!!

    • @TheExcellentLaborer
      @TheExcellentLaborer  2 ปีที่แล้ว +1

      Stay tuned, I will be doing one in the future!

    • @jacobkelso9867
      @jacobkelso9867 2 ปีที่แล้ว

      @@TheExcellentLaborer thanks brother.. keep the vids coming!!

  • @JS.990
    @JS.990 2 ปีที่แล้ว

    I hammered the like button, now I need a new phone -_- . Thanks a lot my guy.

  • @TrueCrimeQueen
    @TrueCrimeQueen 2 ปีที่แล้ว

    I love your content! Be safe out there everyone 💜💜💜

  • @davidc9135
    @davidc9135 ปีที่แล้ว

    Outlets 2' out from the corner makes sense for accessibility seeing as counter depths are going to be around 2' from the corner

  • @pedropereira8924
    @pedropereira8924 3 ปีที่แล้ว +1

    Thanks a lot for sharing your experience, excellent

  • @jeffreyvictor3678
    @jeffreyvictor3678 ปีที่แล้ว +1

    Could you put a dedicated junction box under the kitchen sink cabinet with a gfci outlet for both the dishwasher and garbage disposal?

    • @sargentnocap1414
      @sargentnocap1414 ปีที่แล้ว

      Yes but make sure to run 12/2 wire and have it on a 20amp breaker.

  • @aaudain1
    @aaudain1 ปีที่แล้ว

    Why am I now seeing this 😭 thanks for sharing 👍 🙏

  • @kirkshirley1319
    @kirkshirley1319 7 หลายเดือนก่อน

    the kitchen outlets are not required to be on an arc fault but it doesn't hurt. As of the 2023 NEC (210.52(C)(2) I believe) you cannot put an outlet on the side of an Island. You can use a pop-up outlet rated for that use or put it in the backsplash of a 2 level (bar) or cap it off underneath for future. (Weird, I know.)

  • @laura8512
    @laura8512 3 ปีที่แล้ว +4

    Great video! This was exactly what I needed.

  • @tonyaction5284
    @tonyaction5284 2 ปีที่แล้ว

    Great video brother!!!🤙🏼💪🏼

  • @tszymk77
    @tszymk77 3 ปีที่แล้ว +1

    Thank you.

  • @jms6184
    @jms6184 2 ปีที่แล้ว

    Another great video. You probably have videos on the actual wiring the switches and plugs maybe should've referred us to that video(?). According to your video a kitchen will have at least 5 separate circuits (Frig, MW, DW left and right side)? I didn't realize the MW and DW had to be on separate circuits(?). I thought we could wire the DW with garbage disposal(?). Thanks -

  • @grilledcheesesammy
    @grilledcheesesammy 7 หลายเดือนก่อน

    The horizontal 2x4s about 4 foot up is that to catch your cabinets? I'm in the middle of building my 1st house and you're great help Thanks

  • @withphateama3094
    @withphateama3094 2 ปีที่แล้ว +1

    Awesome 👌it would be great to build a home with you. I would love to get some hands on experience with electricity installments.

    • @TheExcellentLaborer
      @TheExcellentLaborer  2 ปีที่แล้ว

      Hands on experience is the only way I learn also. I worked with my father for years to develop the skill set to handle wiring, plumbing, ect. Thank you for watching!

  • @seanhorton3811
    @seanhorton3811 7 หลายเดือนก่อน

    The 2023 NEC no longer requires islands or peninsulas to have a receptacle. See NEC 210.52(C)(2) & (3). These were commonly mounted on the sidewall of the cabinet. Now, the island must have the ability to have it added. Think either run an empty conduit accessible at both ends or the wiring not connected and/or ran to a box but safed off. This is so one can be added if the code changes again without tearing up the kitchen.
    There are safety issues of having a cord running over the side of the counter top where the cord can be pulled, possibly dumping the hot contents of a cooking appliance onto someone. Children have been badly burned. If the owner wants one installed the way the previous code required, the code does not prevent it. They just don't count towards the required receptacles. I would not install it, explain why, and let them use the "future install" option at their own doing. A much better option is a counter top receptacle that is specifically listed for the use. A web search will show options for work surface and counter tops, they are different in the code as how and where they can be used.
    A sidewall mounted island receptacle is major safety liability and a lawsuit waiting to happen. Installer beware.

  • @idhatemet00
    @idhatemet00 ปีที่แล้ว

    For the microwave, i would recommend just terminating it in a box as usual, then once cabinets are installed you can just put an extension box or plastic box extenders (white pvc sleeves that would sit on the face of the cabinet backing and extend into said box). I'm personally not fond of the idea of drywall installers having to install and tape around a bare romex sticking out from the wall.

  • @nancylewis7142
    @nancylewis7142 2 ปีที่แล้ว

    Excellent.

  • @justinbailey7281
    @justinbailey7281 2 ปีที่แล้ว +1

    So what type of contractor like what license do you hold?

  • @jstone1211
    @jstone1211 ปีที่แล้ว

    the cost of these Combined Fault breakers is significant. I am all about GFCI breakers and outlets, but AFCI breakers I have to look at the ROI and wonder how many houses have been burnt because of arc faults. Personally, I think solid electrical work by licensed professionals would eliminate any possible arcing. And to be honest, the circuitry for the AF is simply a frequency detection circuit as an arc creates a higher frequency above the 60HZ. but the code requires them so....

  • @Sean4reall
    @Sean4reall ปีที่แล้ว

    Does the outlet for the microwave really have to go straight to the circuit breaker (I’m in Virginia)? This is an awesome and informative video!

  • @harshadpatel5349
    @harshadpatel5349 4 หลายเดือนก่อน

    Do you have any video on range hood vent rough-in, or any suggestion on it?

  • @techdave05
    @techdave05 3 ปีที่แล้ว +10

    Unless there is a code in your area, there is no code for left and right. What I like to do is alternate the recepts with the circuits.

    • @TheExcellentLaborer
      @TheExcellentLaborer  3 ปีที่แล้ว +1

      Very good David! We always divided it by left and right but it may not be the exact verbiage. Thanks for watching!

  • @harolddouglas4057
    @harolddouglas4057 2 ปีที่แล้ว

    Just a suggestion; tell us what version of the NEC you are working to: 2014, 2017, or 2020. (I'm pretty sure not 2020.)

  • @greensfarmland
    @greensfarmland ปีที่แล้ว

    Great video, but what about the garbage disposal? Did I somehow miss it?

  • @smitlag
    @smitlag 2 ปีที่แล้ว +1

    Yep kitchens chew up a lot of panel space given the number of dedicated circuits. I think your garbage disposal is another dedicated circuit.

  • @holasoyabelalclopez3679
    @holasoyabelalclopez3679 24 วันที่ผ่านมา

    How many outlets and lights goes connected on a 12/2 wire?

  • @randypaul5427
    @randypaul5427 3 ปีที่แล้ว +2

    I forgot to ask, so you’re using AFCI/GFCI breakers instead of the GFCI receptacles in the kitchen and near water sources? Thanks Josh!

    • @TheExcellentLaborer
      @TheExcellentLaborer  3 ปีที่แล้ว +3

      Correct Randy! It may cost a little more to do it that way but it is less complicated than trying to remember which circuits you’re going to buy a GFCI breakers for and which ones you are not. You are welcome!

  • @marcusjames3035
    @marcusjames3035 2 ปีที่แล้ว +2

    Does the plug for refrigerator have to be 20amp?

    • @electricaf365
      @electricaf365 2 ปีที่แล้ว +1

      Outlet or receptacle. Not a plug 🔌

    • @surferdude642
      @surferdude642 2 ปีที่แล้ว

      If it's a dedicated line you could probably use a 15 amp circuit, but it doesn't make sense as a 20 amp circuit has advantages and the cost increase is not much.

  • @markn.795
    @markn.795 2 หลายเดือนก่อน

    Does the outlet have to be 20 amps for the kitchen or 15 amps on a 20 amps circuit is ok?

  • @jcaleca60
    @jcaleca60 2 ปีที่แล้ว +4

    Good video the only thing on a 3-wire 12 make sure when you snap the breakers in your black wire from the three wire number 12 is on phase a and the red wire is on phase B this way you don't overwork the neutral that is code

    • @electricaf365
      @electricaf365 2 ปีที่แล้ว

      🤣🤣🤣🤣🤣🤣 where did you hear that crap?

    • @jcaleca60
      @jcaleca60 2 ปีที่แล้ว

      When I was in school for my master electrician license for New York City is where I heard that if you think about it the neutral balances the unbalanced load so theoretically if you're drawing 10 amps on one breaker and 10 amps on the other you won't even need a neutral

    • @jcaleca60
      @jcaleca60 2 ปีที่แล้ว +1

      @@electricaf365 I don't know what school you went to but you could look it up on the internet all your circuits should be balanced

    • @electricaf365
      @electricaf365 2 ปีที่แล้ว

      @@jcaleca60 you won’t find that in any code book.

    • @jcaleca60
      @jcaleca60 2 ปีที่แล้ว

      Look up electrician U Is the name of the guy neutral imbalances In multi wire branch circuits it's too hot one neutral

  • @StephenLawrence-n3b
    @StephenLawrence-n3b ปีที่แล้ว

    At what high from the floor is good for drilling the stud holes for the horizontal runs to the countertop outlets?

  • @feldmanjared
    @feldmanjared 3 ปีที่แล้ว +1

    I can’t get enough of this series. I always thought building “code” was for safety, but it seems like for outlet distances it’s just for homeowner convenience? Is most code like that?

    • @idealalaska8259
      @idealalaska8259 3 ปีที่แล้ว +4

      I believe the maximum spacing of outlets was determined with safety in mind. The 4' max spacing in a kitchen, for example, is based on the length of appliance cords (toaster, coffee pot, etc). Some appliances have a 2' long cord (though they might be longer), so this code rule will allow the toaster to be placed anywhere along the counter and able to plug into a receptacle without the use of an extension cord. Use of extension cords tend to increase shock and fire hazards.
      Floor lamps should have at least a 6' cord, which is why the maximum spacing of wall receptacles in living rooms, bedrooms, etc. is 12'. Again, to allow the lamp to be placed anywhere along the wall without having to use an extension cord to reach a receptacle.
      Some electrical code rules are not obvious as to how safety is involved, and the NEC (National Electrical Code) certainly does not explain the "why" behind its requirements.

    • @feldmanjared
      @feldmanjared 3 ปีที่แล้ว

      @@idealalaska8259 Awesome explanation, thanks Alaska!

    • @TheExcellentLaborer
      @TheExcellentLaborer  3 ปีที่แล้ว

      I feel like most codes are a blend of safety and convenience. Also it protects against shotty designs. For instance you would not want a toilet tight against the wall because it is not functional. Thanks for watching!

    • @anthonymccoy4460
      @anthonymccoy4460 2 ปีที่แล้ว +1

      Some of the code is made with handicapped people in mind as well.

  • @mikeheller1225
    @mikeheller1225 5 หลายเดือนก่อน

    My electric range is 240 volt - 40amp. What are you putting in that requires 50amp?

  • @chains6558
    @chains6558 2 หลายเดือนก่อน

    Does anybody know what size mail is used to mail the outlet boxes to the stud?

  • @geniusmarcsays2434
    @geniusmarcsays2434 4 หลายเดือนก่อน

    do you have a wiring for a house that i not made out of wood? in my country nobody uses wood

  • @cavemanconstruction116
    @cavemanconstruction116 9 หลายเดือนก่อน

    Great video. I have a plumbing question. Sorry to be that guy lol. At 12:30 in the video, you show the sink and outlets around it. I see your pvc sink drain under the window and looks like an F. Also didn’t see a vent. What are you doing there? I am assuming the bottom pvc inlet is where you will add your P trap for the sink and the top one is for a ventless vent. Is that correct? I am dealing with a similar issue, that’s why I asked thank you

  • @jasondeleon5511
    @jasondeleon5511 ปีที่แล้ว

    Was just wondering what the Hole (looks about 8inch) on floor where kitchen sink is for. I’m Just about done with drain and vent pipes, and water in, about to start electrical.

  • @23snacKs
    @23snacKs ปีที่แล้ว

    7:47 now i want to show you some things about the miker wave :D

  • @abdulzabed
    @abdulzabed ปีที่แล้ว

    if you don't mind how much do you charge to do single family house. please

  • @eodninja6
    @eodninja6 ปีที่แล้ว

    I have an issue in my house. Builder used a 3 wire from panel to the gang box for the fridge. The black wire is only feeding the outlet for the fridge. The red wire is spliced into a new 2 wire run that feeds the microwave and stove top. Red and black are on separate breakers. My problem is, if I open the black wore breaker, I get 40vac on the red wire. Nothing is plugged in, and all other breakers are open.

  • @clumpkin1012
    @clumpkin1012 8 หลายเดือนก่อน +1

    Can it be closer than 24" from the sink?

  • @busty1372
    @busty1372 ปีที่แล้ว +1

    When remodeling older home, make sure to level boxes, as floor may be out of level..

  • @eklasurrahman2711
    @eklasurrahman2711 2 ปีที่แล้ว

    Which one for bedroom kitchen ' bathroom and living room line size to power to every room

  • @wizard3z868
    @wizard3z868 ปีที่แล้ว

    as far as cost wise if you can get afci breakers being $30 and i have gotten gfci outlets on sale in multi packs discounts at less than $10 a pce vs combo breakers at avg $75 but again yes avg gfci outlet $20 to $30 a pce so ya combos are easier cost effective unless you do your shopping

  • @peterbourbous1035
    @peterbourbous1035 2 ปีที่แล้ว

    Hey Josh, love your videos. They are the most useful and comprehensive that I have seen. Just wondering, what about power for a garbage disposal???🙄🤔

    • @bmfitzgerald3
      @bmfitzgerald3 ปีที่แล้ว

      This is subject to your local jurisdiction, but based on my research I have found that the dishwasher does NOT need to be on a dedicated circuit. You wouldn't want to put it on your small appliance circuits, but you could likely share your dishwasher circuit with your garbage disposal. So, a 20 amp, 12 gauge wire circuit serving only your dishwasher and disposal.
      Worth noting, your local code may require a switch to disconnect your dishwasher. You could run an the incoming line into the sink cabinet for two receptacles. One receptacle to power the dishwasher, and another to power the disposal. You would then run two "switch legs" to switches at the front of the sink cabinet so that one switch would cut off the dishwasher (as required by code), and the other switch would turn the disposal on and off.

    • @davidsteinberg8024
      @davidsteinberg8024 ปีที่แล้ว

      Around here both the dishwasher and disposer are fed by one 20A circuit on plug receptacles in the sink cabinet. Use a two-gang box so one side gets a GFCI for the dishwasher and the other side a switched plain outlet for the disposer. There are several styles of disposer switches so I can't go into that here.

  • @jcaleca60
    @jcaleca60 2 ปีที่แล้ว +1

    The right way to do this circuit look up look up a guy named electrician u.. Neutral imbalances in multi wire branch circuits 2 hots Is one neutral

  • @Mitierragt753
    @Mitierragt753 2 ปีที่แล้ว +1

    You said your not license electrician. So how did you get your house inspected . I’m confused so if is your own house the inspector does not ask for license .

    • @TheExcellentLaborer
      @TheExcellentLaborer  2 ปีที่แล้ว +1

      In my jurisdiction I am building in, I can wire my own house if it is mine. It’s still gets inspected thoroughly. Thanks a lot for watching!

  • @tuyentran3456
    @tuyentran3456 ปีที่แล้ว

    Thumbs 👍👍👍that all I have to say

  • @gene2514
    @gene2514 ปีที่แล้ว

    Great videos! I’ve been demolishing and rebuilding house I just bought and really enjoy your videos.
    Question: I’m just curious why you used a 15 amp receptacle for the microwave? (which I learned from your video, must be on a 20 amp designated circuit)I would think with venting systems commonly combined in microwaves that a 20 amp might be more suitable (again electrical newbie here). I was told a 15 amp receptacle on a 20 amp circuit could deteriorate quickly and risk electrical fire.
    Thanks again!

    • @johnn.freisen3952
      @johnn.freisen3952 ปีที่แล้ว

      He states he is not an electrician. He doesn't know that a dedicated 20amp circuit can NOT use a 15amp receptacle. Only the 20amp branch circuits with multiple receptacles may use a 15amp receptacle. A dedicated circuit may not have a receptacle smaller than the dedicated branch circuit. FYI some states do not allow any 15amp receptacle on 20 amp branch circuits.

  • @willhamilton9121
    @willhamilton9121 2 ปีที่แล้ว +1

    You do mount a box for your microwave, buy 2in screws

  • @nicksmetzer9361
    @nicksmetzer9361 11 หลายเดือนก่อน

    So you mention 2 20amp (left amd right) what if my kitch len has another left another (L) shape on the adjacent side. Basically 4 walls of outlets?

  • @Platerpus7
    @Platerpus7 ปีที่แล้ว

    Do you need an outlet 24 inches from the sink if the sink is center on an island?

  • @cameroncowles6232
    @cameroncowles6232 2 ปีที่แล้ว +2

    Please turn your music down. It's very loud compared in contrast with your voice. Great video, thanks!

    • @TheExcellentLaborer
      @TheExcellentLaborer  2 ปีที่แล้ว +2

      Note taken. My newer videos are definitely volume correct. Thanks for watching!

    • @cameroncowles6232
      @cameroncowles6232 2 ปีที่แล้ว

      @@TheExcellentLaborer Oh, nice! Keep up the great work. My wife and I have been binging your videos as we work on our first home together (big fixer upper)

  • @wrightb4ureyes
    @wrightb4ureyes 2 ปีที่แล้ว +1

    I really enjoy all of your videos. Thank you! Quick question on the island electric, I really like the pop up outlets with the usb ports. I am assuming that would be okay to substitute for the side outlets? I have seen WAY too many things get knocked off the island counter if someone hits the cord.

    • @TheExcellentLaborer
      @TheExcellentLaborer  2 ปีที่แล้ว +1

      I will check your local building codes on that. I have not put in outlets like that before so I’m not sure. Good luck on your project! Thanks for watching!

  • @chrisbrady9122
    @chrisbrady9122 11 หลายเดือนก่อน

    I have a question my mom lives in double wide this is her place all receptacles in one room have no power Took a receptacle out check the hot wire has nothing nothing tripped in the rest of the place everything's working none of the main breakers are hot ceiling fan I did replace three receptacles cuz this has happened before I had power got power back into the room l last night it did it. The first time power comes back on by it's self

  • @04llydmaxmley27
    @04llydmaxmley27 ปีที่แล้ว

    How do you run your wiring for under cabinet lighting while the kitchen is just studs?

  • @pugpack45
    @pugpack45 2 ปีที่แล้ว +1

    I have a question with regard to outlet placement on an island. The island is 84 x 51. On 1 side will be a dishwasher, adjacent to the sink, adjacent to an 18" double garbage pull out. The mirror side of the 18" cabinet will be another 18" cabinet with drawers. That is it. There are no cabinets behind the sink cabinet (36") and the dishwasher (30"). The space is designed for counter seating. The only outlet planned was to have one above the baseboard behind the kitchen cabinet (GFCI). There is no place to put any outlets 12" below the counter top. Do you have any suggestions?

    • @TheExcellentLaborer
      @TheExcellentLaborer  2 ปีที่แล้ว

      In a case like that I would call the inspector to see what your best options are. In my area, the inspector will even come out to give you an alternative solution. Hope that helps!

  • @thebestalbum152
    @thebestalbum152 ปีที่แล้ว

    can I install an electrical outlet above the fireplace for TV purpose?

  • @AdamS-lh2ug
    @AdamS-lh2ug ปีที่แล้ว +1

    Per 2023 code, receptacles are NOT to be installed at all on the side of islands. Turns out they’re unsafe for children. They are to go on top as a pop up or the means to install a pop up need to be provided.

    • @johnhooton3286
      @johnhooton3286 10 หลายเดือนก่อน +1

      Not required on islands at all in 2023

  • @jonthealth9187
    @jonthealth9187 2 ปีที่แล้ว

    Do you do remodels? I am doing research I bought a house and the stove is freakishly close to the sink, I'm small and I'm the only person who can fit in there to wash the dishes.

  • @taniksambo1969
    @taniksambo1969 2 ปีที่แล้ว

    Hmm so if you are updating an old house. 1980. They don't have home run for fridge or range. So do you need like 3 to 4 circuit breaker for a kitchen? And what if your panel don't have space on the panel?

  • @NaturalMeditation88
    @NaturalMeditation88 2 ปีที่แล้ว

    do you have a video on upgrading panel from 100 amp to 200 amp? and do I need to rewire?

  • @anonymousperson4363
    @anonymousperson4363 2 ปีที่แล้ว

    Island code for islands is more complicated than 4 foot apart. Also, the refrigerator is supposed to be a dedicated circuit.