This is lateral pile load test followed as IS 2911 (Part-4). For any query contact us bicbareilly@gmail.com or call me 8279524588. We also provide pile load test.
Aaram se pressure liya. Ground ki HBC 20mt/sq. m hoti h. Pressure maintain karna padta h , hamare pass veriable pressure pump h. Wo autometic pressure maintain karta h.
No sir, is code ke according routine test 1.5 times karte h, aur initial test 2.5 times Design load same hi hota h dono case me. Initial test per ultimate load diya jaata h, aur routine per working load diya jaata h.
Wow
Requesting you to show us the actual calculations also...pls
Load calculations
What is the design test load given at site?...And what is the size of concrete block where hydraulic jack is attached?
Safe load 11 MT
Block size 1200 x 1200
Jack is in between block and pile
What purpose for this test
To check the bearing capacity of pile
Saporting pile kaha par hay.?
Saporting pile nahi hay load nahi la pai ga or test fail ho jayega.?
28 MT aaran se bear karta h 1200mmx12mm ka block
Pump ki lagatar low pressure per chalta chodna padta h jisse pressure back na jaye.
@@BilalKhanbic oh to thik hay,
magar block may presar la pay ga kya,
Aaram se pressure liya. Ground ki HBC 20mt/sq. m hoti h. Pressure maintain karna padta h , hamare pass veriable pressure pump h. Wo autometic pressure maintain karta h.
Agar hum initial test ki jagah routine test kare to design load and test load kitna raheta hai???
Design load same rahega, test load change ho jayega,
Test load Safe load ka 1.5 times hoga.
@@BilalKhanbic But as per IS code for routine lateral test design Load is same as working load.
No sir, is code ke according routine test 1.5 times karte h, aur initial test 2.5 times
Design load same hi hota h dono case me. Initial test per ultimate load diya jaata h, aur routine per working load diya jaata h.
@@BilalKhanbic Cl.8.4.1 clearly mentioned that for lateral routine load test load is same as working load.
@@BilalKhanbic For lateral initial test 2.5 time is ok but for lateral routine test test load is same as working load.
Sir How to contect you.
+91 87917 74490