Bahot kuch clear ho gya sir aaj,,, superb sir ,, Sir plz Post tensioning of pier cap ,I girder, aur pre stressing ke , 2,3 video banaeye details me ..plz sir
Routine pile me jis pile ko test kar rahe uska steel cut krne se wo pile to useless ho gaya usko kaise use kr sakte aage jaise ki pile cap ki casting kaise karenge jab steel cut kar diye to
Sir bentonite ki jagha ab polymer bhi use ho raha hai to kon sa polymer better ja or iska use kaise karte hain iske testing method kya hai or benifit kya hai iska
Dear test completed hone ke baad chipping kar ke 10D welding karna hai as per required length of steel ya Approved drawing Jo length hogi. Ish ke baad hi pile cap casting karna hai bhai.
@@rbsinghcivilengineeringaca6777 sir 1 more questions plz reply Settlement maximum for Lateral load- working pile, test pile Vertical load - working and test pile Pull out test - working and test pile
Bahut badiya sir aapke video dekh ke sare doubts clear hojata hai very nice 🙂
🙏👌👍
Good Knowledge expand sir
Good work keep it up Sir.....
Pile VLT ki jankari starting to ending bahut hi super.... With graph.
Ji sir 👍
@@rbsinghcivilengineeringaca6777 sir ye test ka naam initial load test hai na??kya lateral load test bhi initial me ata hi ya routine mein?
Very good explanation
Thank you for explaintion 👍
Bahot kuch clear ho gya sir aaj,,, superb sir ,,
Sir plz Post tensioning of pier cap ,I girder, aur pre stressing ke , 2,3 video banaeye details me ..plz sir
Very good.
sir, u are fantabulous , keep up it .
Well done.
You all work very well
Good sir
Bhaiyo me bhi tha us test me 😂😂
Very well explained.
Super 👌
Good job sir
Very good
Sir ji pass ho gya 👍
Yes 👍
Once time seen the video and all dobt clear
Kindly koi beam or block ki calculations k bry btaye ga
Sir lateral pile load test ppr bhi bnaiyega
Concrete block ka wait kaise nikalte hai
Sir ek heavy civil infrastructure ka v bnayeye Test load
Aur sir pier cap k arrangements details m with drawing sir video banaye viaduct k sir
Hlo sir apko bridge load test ki report ka graph ata hai kya sir agar ata hai toh sir bta dijiye please sir
Routine test main bhi settlement 18 mm limit hain..if the pile diameter is more than 600 mm...
Ya
Sir lab test bhi construction ka karaye
Routine pile me jis pile ko test kar rahe uska steel cut krne se wo pile to useless ho gaya usko kaise use kr sakte aage jaise ki pile cap ki casting kaise karenge jab steel cut kar diye to
Steel ko cut off level c cut karte hai test complete hone k baad pile head ko break kar k fir steel lap kar sakte hai
Sir kiska project hai ye
Aap kon se project pe hai
Sir please share pepper work
Sir bbs bnana sika do
Sir plate load test ka video chahiye mujhe sir
Sir pile ka total 3 test hi hote hai
PDA or dynamic
Lateral load
Vertical or static load test
Ji dost , Dynamic ka procedure alag hota hai. 👍
Sir is block ka size and weight kitna hona chahiye
Length - 1x 1x1 MTR., Weight - 2300 kg to 2400 kg per block..
Nice sir ye video require tha sir ye sheet app upload kar sakte hain kya jo test sheet hai
Next video mein jarur clear rahega 👍
Sir kaise ek pile fail ho sakti hai agar checking k waqt koi mistake ho jaye kin mistake se bachna chahiye
Sir piling ka start kaise karte hain or iski depth ko kaise measure karte hain actual method kya hai
Pile ki depth ko measure karne ka
Sir bentonite ki jagha ab polymer bhi use ho raha hai to kon sa polymer better ja or iska use kaise karte hain iske testing method kya hai or benifit kya hai iska
Sir ji....humari site....aur hum hin nadarad
Office me rhne pr foto nhi aayega site pr bta rhe hai sir
Kaha karte h test
Plz clear video sir
Ok dear 👍
Sir pile load taste ke equipment purchase Karna hai tell me
Please contact this number , Mr. Kapil ji. - 9924350229, Regarding Load test equipment.
sir pile ka upper steel jo remove kr diya tha vo pile cap me kese aayega
Dear test completed hone ke baad chipping kar ke 10D welding karna hai as per required length of steel ya Approved drawing Jo length hogi. Ish ke baad hi pile cap casting karna hai bhai.
Pile head ka sariya mod dena chaiyye. With head diye.
@@empiregaming2094 without steel cutting head not proper making as per required pile dia.
Dekai nehi deta page ka leka
Sir,
yea load taste kaha par ho rahe,
Kon sa campani yea load taste kar rahe.
Dear test completed ho gaya hai 👍👍
@@rbsinghcivilengineeringaca6777 sir, ap ne kiya he kya.
Yes 👍
Sir kentledge load Kitna lenge design load k
Test pile ke liye - 2.5 Times & working pile - 1.5 times & dead load 1.25 times minimum extra lete hai.
@@rbsinghcivilengineeringaca6777 sir 1 more questions plz reply
Settlement maximum for
Lateral load- working pile, test pile
Vertical load - working and test pile
Pull out test - working and test pile
Pls.share calculation sheet with reading
Dear calculation per bhi video hai hamare channel mein, please check..I hope your doubt will be cleared.
Sir kon si lab hai aap ki ??
I am civil Engineer & working at construction company, testing by third party..
If you have any question related to test then you can ask us.
या कहीं टेस्ट करवाना है तो टेस्टिंग एजेंसी का नंबर और एड्रेस प्रोवाइड करवा देगे..
I want to meet .rest we will discuss in private channel pls. Contact me ..
Sir kya is report sheet ki pdf copy aap mail krskte hain
Sir quality ki training ap ke pass se karni hi
Bhai abhi vacancy Nahin hai jab hogi to batayenge..
Secondary bim load hi nhi lega
sir please share test report in pdf
Sir,
Design load kitna he.
76 MT Brother.
Please send pdf
Sir I am pile load Engineer if you required testing and reporting Call me
First learn to say SITE.. not side !!