There are many mistakes here 🙏 1. Your surface preparation is not adequate there is lot of cement latence on the floor after the chisel and hammer wire brushing needs to be done with intermittent washing to remove all loose latence. Covings at wall joint is missing proper cement sand covings need to be made before waterproofing treatment. 2. After final washing it's important that we hydro test by filling water up to 3 inch to check leakage .(we need to treat the leakage and after repair we again hydro test and see for any active leakage if all is ok only then we go further . 3.We wash and allow surface to dry till it's damp usually 2 to 3 days but depends on atmospheric weather conditions. 4. Primer coat is applied in cross hatch Patten at least the surface is completely blinded with primer till coat is tacky. 5.Apply the first coat of so that you get at leat 1.5 to 2 kg material per sq.mt of as per manufacturer data sheet. Apply the second coat when the first coat is tacky .in cross hatch consuming 1.5 kg to 1.8 kg . Allow the coats to air cure. Also place a small bleeder pipe closed at one end with perforated holes opening towards the shaft where the pipes will run it shall work as a drain incase there is a pipe leak in the sunken along with the water and waste. As for the mistake here there are so many . Primer is too too thin The surface is wet and there is stagnant water ,etc and more I recommend to do away with sunken and to hide the pipes we can do false celing which can be openable it's being followed by many builders .
301 doc fixing plain code first time, second time 112 with cement, third time 301 with white cement, 3 layer production then finally do flooring with cement before tiles laying
DRFIXIT Documentation says one should not mix any cement/white cement with the material. But you have added what it likes white cement, Does it make it effective
From 1:42, when you haven't water proof the floor, you already use water! What is the point of water proofing later when water already seep into the ground prior to water proofing?
Hello sir Bathroom me water proofing karvana bahut jaruri hota hai Water proofing ki jagah yadi ek bada patathar rakhkar uske upar bathroom banaya ja sakta hai to isse kabhi Pani niche nahi jayega Kya ek single patathar ke upar bathroom banana sahi hoga
shouldn’t be added cement other than the cement came along with the pack and this will applicable for water, only white chemical should you.. wrong information
What you are adding, give in details ratio. Is it better to do waterproofing Dr fixit URB + cement 1:1.5 ratio. Better to do with a 4" brush and then plastering the areas.
OMB WALL MAGIC COAT 🔥 क्या आप गर्मी से परेशान हैं क्या आप गर्मी से मुक्त होना चाहते हैं यदि हा तो हम आपके लिए लाए हैं गर्मी कम करने वाली बाहरी कोटिंग अंदरूनी सतह को लंबे समय तक ठंडा रखता है 🔥🔥🔥🔥🔥🔥🔥🔥
There are many mistakes here 🙏
1. Your surface preparation is not adequate there is lot of cement latence on the floor after the chisel and hammer wire brushing needs to be done with intermittent washing to remove all loose latence.
Covings at wall joint is missing proper cement sand covings need to be made before waterproofing treatment.
2. After final washing it's important that we hydro test by filling water up to 3 inch to check leakage .(we need to treat the leakage and after repair we again hydro test and see for any active leakage if all is ok only then we go further .
3.We wash and allow surface to dry till it's damp usually 2 to 3 days but depends on atmospheric weather conditions.
4. Primer coat is applied in cross hatch Patten at least the surface is completely blinded with primer till coat is tacky.
5.Apply the first coat of so that you get at leat 1.5 to 2 kg material per sq.mt of as per manufacturer data sheet.
Apply the second coat when the first coat is tacky .in cross hatch consuming 1.5 kg to 1.8 kg .
Allow the coats to air cure.
Also place a small bleeder pipe closed at one end with perforated holes opening towards the shaft where the pipes will run it shall work as a drain incase there is a pipe leak in the sunken along with the water and waste.
As for the mistake here there are so many .
Primer is too too thin
The surface is wet and there is stagnant water ,etc and more
I recommend to do away with sunken and to hide the pipes we can do false celing which can be openable it's being followed by many builders .
In Chyna, we do not waterproof homes.
The houses are meant to only last 7 years
How to do waterproof at new construction home. Where lanter is plain.
Not clear what your are doing and which meterial you are using
301 doc fixing plain code first time, second time 112 with cement, third time 301 with white cement, 3 layer production then finally do flooring with cement before tiles laying
Bhai.. aur thoda detail mein samjha sakthey hn kya ??
Fosroc Brushbond vs Dr Dixit 301 - Which is better?
ho
The Best procedure.
Many many thanks
Product ka name nd usage to bta dete bhai
DRFIXIT Documentation says one should not mix any cement/white cement with the material. But you have added what it likes white cement, Does it make it effective
It comes with cement.
For LW+ cement is used
From 1:42, when you haven't water proof the floor, you already use water! What is the point of water proofing later when water already seep into the ground prior to water proofing?
It's already leaking at my home. Can't touch the bathroom above. What can be done to stop it from below room?
Sir aap ek video send kijiye ese pta nhi lagega. Me shayad apki help kr sku
Need more videos like this
Mr brother, you are not mentioned chimical used, you doing work adda type
Nice concept sir from which state you are
Sigana india
Meraj
good work
Bathroom tiles leakage ka problem kaisa solve kare.
Can u mention the particular products which u mixed first
Dr Fixit pidfin.
What powder was mixed with Dr.Fixit waterproofing
That is actually slow setting cement which is provided according to the proportion
Damp Proof Powder
Hello sir
Bathroom me water proofing karvana bahut jaruri hota hai
Water proofing ki jagah yadi ek bada patathar rakhkar uske upar bathroom banaya ja sakta hai to isse kabhi Pani niche nahi jayega
Kya ek single patathar ke upar bathroom banana sahi hoga
Hi very good
How much meter for hight in tha flor 1 or 2 meter
Which is better fosroc or dr.fixit
BASF is the best
Which 2 cement is put.
Good👍
Good and detailed information sir
Super
You must not add anything in Dr fixit 112 it's written on box wrong information..
Brother apne cement mix kiya esa krna theek hai keya pls answer?🙏
Use app membrane or 2k
Bilkul galat hy pidifin 2k is a not dilution product
Waterproofing step by step video is now available
Pls give the link for that video
Step by step kya kya add kiya batana chahiye
shouldn’t be added cement other than the cement came along with the pack and this will applicable for water, only white chemical should you.. wrong information
I think they mixed too much water
Sir plz give us information about estimate??
Material datails???
Put powder into the water.
Pls dont add cement and water
Dr fix it ka galat product istamal kar rahe ho, 301 product istamal karna caheye.
There is no mention of material used. Just showing the work video doesnt make sense
First you mention product name in description.....
Pidifin 2k dr fixit
Sir aap ne to coting hi kar diye or joint me to wata banaaye hi nahi
What you are adding, give in details ratio. Is it better to do waterproofing Dr fixit URB + cement 1:1.5 ratio. Better to do with a 4" brush and then plastering the areas.
Right product wrong method.
Manish Nishad ka dukan he thane me vaha se Dr fixit le lena
Bro koving laagara
OMB WALL MAGIC COAT 🔥 क्या आप गर्मी से परेशान हैं क्या आप गर्मी से मुक्त होना चाहते हैं यदि हा तो हम आपके लिए लाए हैं गर्मी कम करने वाली बाहरी कोटिंग अंदरूनी सतह को लंबे समय तक ठंडा रखता है 🔥🔥🔥🔥🔥🔥🔥🔥
Good morning
You are not properly ues the meterial & your leber not trained as well Expat please don't lodede the video you can watch dr. Fixit video property
फर्श पर भूल कर भी टाईल्स न लगवाएं सिर्फ दीवाल पर लगवाएं। वर्ना सिपेज होगा और दीवाल के दूसरी तरफ और छ्त के नीचे सिलन। फर्श पर सिमेंट का घोल मरवा दें।
Tile lagane se silan hota h kya ..grout ko proper epoxy grout se fill kro
Kya naam ka product hai
Dr fixit
It's pidifin 2 k
Nise
Waterproofing,Construction Chemical & Building care products ചെയ്യുന്ന ഒരു ചാനൽ ഉണ്ട്. ഈ മേഖലയുമായി ബന്ധപ്പെട്ടവർ ചാനൽ കണ്ടു അഭിപ്രായം പറയാമോ?
Ok. Which channel
@@swarnas6281 Constra care. Please click my dp
👍🏾
Galat kam ho rha hai
Only appliying dry place
Coating was should do uniformly and in same direction
Sh jondhale college me aaja ye sab hi sikhate he
Ok
This is not the real water proofing materials..
Be more professional.. Use mask, glouse, mixer
waterproofing amar company achhe
Hi
Fail procedure
This is not working i tried totally waste!!
अबे हिंदी में बोल
Hindi bolo g
😂😂😂😂😂😂😂
Very worst video on waterproofing ...
And worker is also not apply pidifin 2k perfectly, it should be applied in horizontal and perpendicular manner
This is not the right way you are doing.... Totaly wrong
Plz share right video
Do you know ?
This is not waterproofing.. its a joke
Putty mixture machine
Mistakes,🙄
Please point out what are the mistakes
Hindi bol sase
Loda...material name plz
Wtf
Hi