have an Atlas Copco GA 37ff and someone accidentally hit the emergency shut off - got it working immediately after watching this...thanks for the vid !
how do you set inverter parameters on a Atlas copco GA 75-90 VSD compressor . I replaced the Siemens inverter Inside it. do I have to reset parameters or will it run on the old parameters which is already set on the keypad.? please help
For short term will work, load and unload but not for long term. The reason because there is a serial number in the controller will say that is not the right compressor. Therefore, you need to call the supplier of the compressor in order to set-up the new serial number of the invertor into the software.
STOP TIME, high volt VSD (more stop time will FIX the problem.) Now the moter send power back 'in STOP MODE' to controler, High voltage / make the stop time 15 sec. or 20 sec. instaed of 10sec....., You get this error if the compressor stops after the idle time. ( made by Atlas Copco China / No problems with your electricity installation, just a short 'INPUT' from VSD engine & CONTROLERS FLIPT ! )
Dear Chouse, thank you for your valuable time dedicated to my question. Sorry, I have another question, the elektronikon graphics stops at that stage, is there a way to restart it?
i have a ZT-160 VSD oil free air compressor, and i have a trip on high element temp in summer season, im trying to change the ramping time, did any one have an idea about how to change it ??
My Air compressor GA45 experience a motor rotation protection.. i wonder what the problem about it? does my motor connection problem or my wiring connection is wrongly connected. Pls assist me. Thank you very much
I have air dryer atlas copco CD150. I need instructions book. Do you know how can I get it? Do you know timer active on control panel air dryer what's mean?
our compressor is stopped and restart again after aperiod af unloaded time is it normal ?? bcs we have an old one never stopped only load and unload!! .also the frequency for stopping and restart is high..
Yes, its normal. It might be because of the temperature or receive wrong signal from the sensor. You you adjust the frequency. When did you last service the compressor?
I have resetted it however the light just keeps on blinking. Please help. We have a GA37 and the upside down triangle error signal keeps on popping up. We have a GA37 by the way and the bars is at 0, unlike the one shown on the video
Most of the cases the problem is the electric connection with different phases. Try to check that. The second scenario can be the low temperature, the compressor has to be kept always over 5 degrees. Check this two options and let me know if its solved.
our atlas copco compressor runs and stop giving an expansion module communication error thus triggering a stop on the machine. you resert and start again, then it stops after 5 minutes on the same error....
hello my factory have ga75 vsd 12.5 bar air comprossor have now almost overall maitanances time reach can you give me the name off that comprossor machanical parts for buy
Our compressor usually get service every 4000 hours and we service the air filter, electric motor and drain separator. We replace the compressor oil every 8000 hours. This is all you need for the maintenance ;)
Hi sir. How to remove the ground fault.why it given in the trouble shooting that contact the company.pl help in this connection.i will be greatfull to you this pl. Regard m.u khan
Hey, Sorry for the late reply. If it's a VSD, that code includes 8, which is heatsink overtemp. Check your fans and clean out dust and filters, for starters.
Hello i have error 3 i already check voltage and its ok. The compressor starts and then its stopps a few times, after all it sends error 3 on the screen. HELP PLEASE
Sir i need to program for automatic startup after power restore ...system ask for security code ..i have user password but it ask for security code ...?
Hey, If it's a VSD, that code includes 8, which is heatsink overtemp. Check your fans and clean out dust and filters, for starters :) I hope this will help.
Hey, in this case there are two options to solve this problem. Option 1: Check the power connection, make sure you have permenant connection without plug and check the breaker. Option 2: Probably the sensor which allows air to the air tank is broken. Please let me know if one of these two options will solve the problem.
hi at first i want thank you for your answer , after a wile of sending my first message i cheeked electric stuffs i found the problem it was in the phase sequenceأ i changed it and it work normal ,but to avoid problems like that i still ignore the causes of that.other thing plze can you help me how do my maintenance and what i need, thank you .
Our compressor usually get service every 4000 hours and we service the air filter, electric motor and drain separator. We replace the compressor oil every 8000 hours. This is all you need for the maintenance. Always remember to keep the compressor in the temperature over 5 degrees ;)
Chouse Molla-Storm I have a same problem with GA18 and I tried this but not yet solve. What else we can do? Actually second option sensor I did not find there..
please Chouse Molla-Storm Can you help me? I have flashed the program on the time error log: Erro 3 Everyone has a way for Flash to help me with. Can you give me the SD Card Backup file? Email: vo.an92@gmail.com thank you very much!
The supplier should have the password, its default password from the factory. If someone created a password by mistake then you need a technician to come with computer and reset the password/remove for you by using computer. That is the only way.
Please have an Englishman give these instructions instead of a Russian, (Now Russies - or Indias English / ... 'the 2-stage in 1' is built 4 Atlas Copco in 'China' !,The CP controllers 3000/4000 (also from china) is a bigger disaster! No good indication AUTOMATIC TURNING or UNLOADED TURNING, "yes" 1 "LED goes out manual position !!! In the past you had a clear Manual or automatic switch for "Turned load and / or turn unload."
have an Atlas Copco GA 37ff and someone accidentally hit the emergency shut off - got it working immediately after watching this...thanks for the vid !
My screen become blank why. Any one can help?
@@eyadhashemzyoud1682 Jitendra rajbhar
From pneumatic air compressor
All type compressor service providers
Atlas copco, CP , KEASER ,ELGI, ingersoll rand , FS CURTIS, KULMEC , etc...
Pls call 9561220176
WhatsApp nu 7709134775
Anywhere
Jitendra rajbhar
From pneumatic air compressor
All type compressor service providers
Atlas copco, CP , KEASER ,ELGI, ingersoll rand , FS CURTIS, KULMEC , etc...
Pls call 9561220176
WhatsApp nu 7709134775
Anywhere
As a tech for atlas I’m glad you have made this video.
I´m too..
hi i have an issue with my atlass copco GA11 FF red light is not resetting i try many time but not gone
Jitendra rajbhar
From pneumatic air compressor
All type compressor service providers
Atlas copco, CP , KEASER ,ELGI, ingersoll rand , FS CURTIS, KULMEC , etc...
Pls call 9561220176
WhatsApp nu 7709134775
Anywhere
Thanks very much ,im from Brasil
Compressor runs unloaded for a very long time, can u plz tell me pressure settings for 7 bar control air use?
how do you set inverter parameters on a Atlas copco GA 75-90 VSD compressor . I replaced the Siemens inverter Inside it. do I have to reset parameters or will it run on the old parameters which is already set on the keypad.? please help
For short term will work, load and unload but not for long term. The reason because there is a serial number in the controller will say that is not the right compressor. Therefore, you need to call the supplier of the compressor in order to set-up the new serial number of the invertor into the software.
always set the basics, speed, start time/ stop time, .... ! (Easy a VSD !)
Jitendra rajbhar
From pneumatic air compressor
All type compressor service providers
Atlas copco, CP , KEASER ,ELGI, ingersoll rand , FS CURTIS, KULMEC , etc...
Pls call 9561220176
WhatsApp nu 7709134775
Anywhere
Good day I would like to ask if anybody experienced like our problem, we follow the reset steps but not working. My unit is atlas copco GA30.
Obrigado, solucionou meu problema.
Can i ask ?What is the purpose of bolaite compressor machine?
Can you help me? Our atlas air compressor always alarm MOTOR CONVERTER TRIGGERED FAULT 22. what would would be the troubleshooting for this?
STOP TIME, high volt VSD (more stop time will FIX the problem.) Now the moter send power back 'in STOP MODE' to controler, High voltage / make the stop time 15 sec. or 20 sec. instaed of 10sec....., You get this error if the compressor stops after the idle time. ( made by Atlas Copco China / No problems with your electricity installation, just a short 'INPUT' from VSD engine & CONTROLERS FLIPT ! )
Hello. Wolud you please help me? I have an atlas copco ga30vsd unit and it shows error 3
I have replaced the LCD but in new LCD screen is coming upside down how to resolve this issue
Hi dear Chouse Mola-Storm, in the elektronikon graphic display appear in the below left corner the text unoperable, Do you know the cause?
Hey, I haven't seen this kind of text before, can you send me a picture so I can look at it? My Gmail molla.chouse@ ;)
Dear Chouse, thank you for your valuable time dedicated to my question.
Sorry, I have another question, the elektronikon graphics stops at that stage, is there a way to restart it?
I never had sach case. In this case I would plug out & in power supply. This is the only way to restart ;)
i have a ZT-160 VSD oil free air compressor, and i have a trip on high element temp in summer season, im trying to change the ramping time, did any one have an idea about how to change it ??
Jitendra rajbhar
From pneumatic air compressor
All type compressor service providers
Atlas copco, CP , KEASER ,ELGI, ingersoll rand , FS CURTIS, KULMEC , etc...
Pls call 9561220176
WhatsApp nu 7709134775
Anywhere
My Air compressor GA45 experience a motor rotation protection.. i wonder what the problem about it? does my motor connection problem or my wiring connection is wrongly connected. Pls assist me. Thank you very much
I think the phases are wrong. Please make sure the wiring is correct.
my model is ga 90ff i doing like this but still stop was not realese
Jitendra rajbhar
From pneumatic air compressor
All type compressor service providers
Atlas copco, CP , KEASER ,ELGI, ingersoll rand , FS CURTIS, KULMEC , etc...
Pls call 9561220176
WhatsApp nu 7709134775
Anywhere
What is the role of sprayer in this machine?
Can we dispense with it?
I have air dryer atlas copco CD150. I need instructions book. Do you know how can I get it? Do you know timer active on control panel air dryer what's mean?
Hey, instruction book usually comes together with the compressor. I don't what means, sorry. In this case, I would contact the supplier.
Jitendra rajbhar
From pneumatic air compressor
All type compressor service providers
Atlas copco, CP , KEASER ,ELGI, ingersoll rand , FS CURTIS, KULMEC , etc...
Pls call 9561220176
WhatsApp nu 7709134775
Anywhere
our compressor is stopped and restart again after aperiod af unloaded time is it normal ?? bcs we have an old one never stopped only load and unload!! .also the frequency for stopping and restart is high..
Yes, its normal. It might be because of the temperature or receive wrong signal from the sensor. You you adjust the frequency. When did you last service the compressor?
Chouse Molla-Storm
it's new one
When compressor need configuration what I can do to solve this problem?
Change to compressor that does not need configuration...
I have resetted it however the light just keeps on blinking. Please help. We have a GA37 and the upside down triangle error signal keeps on popping up. We have a GA37 by the way and the bars is at 0, unlike the one shown on the video
Most of the cases the problem is the electric connection with different phases. Try to check that. The second scenario can be the low temperature, the compressor has to be kept always over 5 degrees. Check this two options and let me know if its solved.
Jitendra rajbhar
From pneumatic air compressor
All type compressor service providers
Atlas copco, CP , KEASER ,ELGI, ingersoll rand , FS CURTIS, KULMEC , etc...
Pls call 9561220176
WhatsApp nu 7709134775
Anywhere
my atlas copco compressor, there is a blinking symbol of tools..trying to find what is the problem, anyone could tell me about it?
Service is required
Jitendra rajbhar
From pneumatic air compressor
All type compressor service providers
Atlas copco, CP , KEASER ,ELGI, ingersoll rand , FS CURTIS, KULMEC , etc...
Pls call 9561220176
WhatsApp nu 7709134775
Anywhere
how to connected with plc abb800m
My Atlas air compressor model number GA18 triggered falt problem
Jitendra rajbhar
From pneumatic air compressor
All type compressor service providers
Atlas copco, CP , KEASER ,ELGI, ingersoll rand , FS CURTIS, KULMEC , etc...
Pls call 9561220176
WhatsApp nu 7709134775
Anywhere
I need a complete online course for GA160 air compressor, could you help me please?
Sorry but I am not mechanic. I don't full functionality of the machine.
Jitendra rajbhar
From pneumatic air compressor
All type compressor service providers
Atlas copco, CP , KEASER ,ELGI, ingersoll rand , FS CURTIS, KULMEC , etc...
Pls call 9561220176
WhatsApp nu 7709134775
Anywhere
What does F1 F2. F3 means please
How to rectify dew point protection triggered alarm ?
are thee the same steps to take on the Ga30?
yes, its the same :)
dear sir, our compressor controller show " CONFIGURATION FAILURE" . How to solve this problem.... ThanX
Try to clean the sensors and filters. After that, make a factory reset. I hope this helps :)
@@mollachouse please help
How to factory reset the controller and again start. We have no backup for downloading or uploading.
Thnk u
Jitendra rajbhar
From pneumatic air compressor
All type compressor service providers
Atlas copco, CP , KEASER ,ELGI, ingersoll rand , FS CURTIS, KULMEC , etc...
Pls call 9561220176
WhatsApp nu 7709134775
Anywhere
In this I am getting inoperate what is the problem
My scroll button at GA11+ isn't response, could u tell me the way to repair it?
I fix the LCD display after that i installed it in the compressor but it can't red the temperatures and pressure its showing *****
our atlas copco compressor runs and stop giving an expansion module communication error thus triggering a stop on the machine. you resert and start again, then it stops after 5 minutes on the same error....
electro valve !
My Atlas make air controller is not resetting, while DI is ok means 1, which is required
All types compressor sells &service for call 9561220176 , 7709137556
hello my factory have ga75 vsd 12.5 bar air comprossor have now almost overall maitanances time reach can you give me the name off that comprossor machanical parts for buy
Our compressor usually get service every 4000 hours and we service the air filter, electric motor and drain separator. We replace the compressor oil every 8000 hours. This is all you need for the maintenance ;)
Jitendra rajbhar
From pneumatic air compressor
All type compressor service providers
Atlas copco, CP , KEASER ,ELGI, ingersoll rand , FS CURTIS, KULMEC , etc...
Pls call 9561220176
WhatsApp nu 7709134775
Anywhere
atlas copco air compresor does not start the intercooler error .the coperessor output is very hot i ask what is it broken
clean coolers
Jitendra rajbhar
From pneumatic air compressor
All type compressor service providers
Atlas copco, CP , KEASER ,ELGI, ingersoll rand , FS CURTIS, KULMEC , etc...
Pls call 9561220176
WhatsApp nu 7709134775
Anywhere
Hi sir.
How to remove the ground fault.why it given in the trouble shooting that contact the company.pl help in this connection.i will be greatfull to you this pl.
Regard m.u khan
I have "starter feedback contact open " issue. where is this contact?
My compressor keeps stopping every now and then any solution like resetting it



Live translation
apa penyebab tekanan tidak stabil??mohon jawabannya...trimakasih
GA22 display "Err bar" what is meaning?
dear friend i have atlas copco ga11-p , whn power is on Igot massage sytem fault 200 and the compressor does not start ! please help
Hey, Sorry for the late reply. If it's a VSD, that code includes 8, which is heatsink overtemp. Check your fans and clean out dust and filters, for starters.
Jitendra rajbhar
From pneumatic air compressor
All type compressor service providers
Atlas copco, CP , KEASER ,ELGI, ingersoll rand , FS CURTIS, KULMEC , etc...
Pls call 9561220176
WhatsApp nu 7709134775
Anywhere
Hello i have error 3 i already check voltage and its ok. The compressor starts and then its stopps a few times, after all it sends error 3 on the screen. HELP PLEASE
Bagaimana car seting naikan bar..
Help.. please air..
Oir air compressor cannot start.. because button on elektronikon panel not responding and alarm appears shutdown close
Try to shut down the power and put back after and see what happens.
Jitendra rajbhar
From pneumatic air compressor
All type compressor service providers
Atlas copco, CP , KEASER ,ELGI, ingersoll rand , FS CURTIS, KULMEC , etc...
Pls call 9561220176
WhatsApp nu 7709134775
Anywhere
Could anyone answer please?
Good very nice I need re wiring manual folt list and operation manual please
Nice video sir
Sir in our compressor it work only in loading condition and not go to unload
Bro check maybe your drayer both running that's why continue puerging
Your air demand it as much as the compressor can make. The machine will make a specific amount. I
my compressure trip changeover time please help me
Jitendra rajbhar
From pneumatic air compressor
All type compressor service providers
Atlas copco, CP , KEASER ,ELGI, ingersoll rand , FS CURTIS, KULMEC , etc...
Pls call 9561220176
WhatsApp nu 7709134775
Anywhere
Intarcooler error showing why
Sir hame Frank screw air compressors MAM .-870 ki display ka password btayie pls
Jitendra rajbhar
From pneumatic air compressor
All type compressor service providers
Atlas copco, CP , KEASER ,ELGI, ingersoll rand , FS CURTIS, KULMEC , etc...
Pls call 9561220176
WhatsApp nu 7709134775
Anywhere
Informing
Sir i need to program for automatic startup after power restore ...system ask for security code ..i have user password but it ask for security code ...?
You have to go on setting mode and then go to motor and enter password 2801 then you can activate automatic start option
It's not working
@@nishantkundu6210 enter 4735
It is a hard Work compressure, I use
Como hago para regular la presión de trabajo
Never trust an operator that wears jewelry on the job lol common job sense 101
i need manual for GA37ff and GA55VSDff in english any body can help me?
Jitendra rajbhar
From pneumatic air compressor
All type compressor service providers
Atlas copco, CP , KEASER ,ELGI, ingersoll rand , FS CURTIS, KULMEC , etc...
Pls call 9561220176
WhatsApp nu 7709134775
Anywhere
How to overcome Atlas Copco GA90 VSD FF, alarm motor convert failure ??? Plese help me,,
Hey, If it's a VSD, that code includes 8, which is heatsink overtemp. Check your fans and clean out dust and filters, for starters :) I hope this will help.
stop time vsd moter to short !
(VSD moter = 'in stop modus' ~generator for the controler / high voltage !)
Jitendra rajbhar
From pneumatic air compressor
All type compressor service providers
Atlas copco, CP , KEASER ,ELGI, ingersoll rand , FS CURTIS, KULMEC , etc...
Pls call 9561220176
WhatsApp nu 7709134775
Anywhere
Plz i have a g11+ atlas copco refuse to start up and it show à red error with stop in the midle i trayed to rearm it , but it refuse
Hey, in this case there are two options to solve this problem. Option 1: Check the power connection, make sure you have permenant connection without plug and check the breaker. Option 2: Probably the sensor which allows air to the air tank is broken. Please let me know if one of these two options will solve the problem.
hi at first i want thank you for your answer , after a wile of sending my first message i cheeked electric stuffs i found the problem it was in the phase sequenceأ i changed it and it work normal ,but to avoid problems like that i still ignore the causes of that.other thing plze can you help me how do my maintenance and what i need, thank you .
Our compressor usually get service every 4000 hours and we service the air filter, electric motor and drain separator. We replace the compressor oil every 8000 hours. This is all you need for the maintenance.
Always remember to keep the compressor in the temperature over 5 degrees ;)
hi freind thank you for helping me
Chouse Molla-Storm I have a same problem with GA18 and I tried this but not yet solve. What else we can do? Actually second option sensor I did not find there..
Why this problem come
Me pasa la misma avería lo quise aser no me sale 🤦♂️🤦♂️
How to set Change language
pleas i need to change config> to automatic restart after power fall >>> i have not the pass word >>> how to relieve the pass word ?
sorry how to recovery the pass word ??
The password can be restarted only by the supplier of the compressor.
thanks
I need the same password too, if any one can help??
@@kanykamil6100 enter 2801
Plz help me how to solve it
Jitendra rajbhar
From pneumatic air compressor
All type compressor service providers
Atlas copco, CP , KEASER ,ELGI, ingersoll rand , FS CURTIS, KULMEC , etc...
Pls call 9561220176
WhatsApp nu 7709134775
Anywhere
How to reset it ?
Hey Fawaz, as long as the machine is working, no need to reset. You need to reset only if someone push the emergency button.
please Chouse Molla-Storm
Can you help me?
I have flashed the program on the time error log: Erro 3
Everyone has a way for Flash to help me with.
Can you give me the SD Card Backup file?
Email: vo.an92@gmail.com
thank you very much!
Serviceing kb karani h kaise pata krte h
servicing k bad kitna runing hour ho gya h ye janne k ley kya krna padta h sir
What do we do if the Console is pass word protected and that we have forgotton the password? How do we go about it?
The supplier should have the password, its default password from the factory. If someone created a password by mistake then you need a technician to come with computer and reset the password/remove for you by using computer. That is the only way.
Thank you dude for the info.
Como consigo manual?
Cuál es la clave para varias algún parámetro
thx
Pode traduzir para o português?
Có vietsub k bạn
my model is ga 90 ff i doing like this steps but still stop alaram blinking what is that reason pls send a reply
Most likely the outlet sensor is broken.
Chouse Molla u have any photos about that outlet sensor
I will find one after I am back from vacation and send it to you ;)
Thanks bro but i find out auxillary contactor for star connection was defective now i change after good
I am glad to hear that :)
JUnk.Oil has water and short groud the motor.. Rear bearing lock nut bolt craks and that's the end of it..
+Alberto Aguilar Try to clean it up, put new oil and replace the bolts. See what happens. You might be lucky.
Stator its short ground it! thats the end of air compressor why oil gets contact with stator with hot oil?
comment branches
Fault 20513
Besoin d'une schéma électrique GA45+
Escuta em português
Please have an Englishman give these instructions instead of a Russian, (Now Russies - or Indias English / ... 'the 2-stage in 1' is built 4 Atlas Copco in 'China' !,The CP controllers 3000/4000 (also from china) is a bigger disaster! No good indication AUTOMATIC TURNING or UNLOADED TURNING, "yes" 1 "LED goes out manual position !!! In the past you had a clear Manual or automatic switch for "Turned load and / or turn unload."
Jitendra rajbhar
From pneumatic air compressor
All type compressor service providers
Atlas copco, CP , KEASER ,ELGI, ingersoll rand , FS CURTIS, KULMEC , etc...
Pls call 9561220176
WhatsApp nu 7709134775
Anywhere