Atlas Ship Service Air Compressor GA37 : Maintenance

แชร์
ฝัง

ความคิดเห็น • 17

  • @stevecarter529
    @stevecarter529 ปีที่แล้ว +1

    Look look look. The ten and a half minute compressor service. No separator, no checks on condition of air/oil cooler and no solenoid service kits. I think my boss would like me to turn around a 37kw screw compressor service in this time.

  • @joshuasinyinza2812
    @joshuasinyinza2812 ปีที่แล้ว

    Nice work

  • @jordanuppal4220
    @jordanuppal4220 2 ปีที่แล้ว +1

    Where did you rebuild the minimum pressure valve and unload solenoid?
    The full 8K service comes with rebuild kits for the valves and the mesh filters were not replaced

  • @mec6953
    @mec6953 2 ปีที่แล้ว +2

    keep it up🥰👍

  • @RamBabu-ev9wl
    @RamBabu-ev9wl 3 หลายเดือนก่อน

    👍

  • @manishdhetarwal4939
    @manishdhetarwal4939 10 หลายเดือนก่อน +1

    In my same compressor DRYER DEWPOINT PROTECTION alarm is coming up...what to do ?

    • @shipneer5984
      @shipneer5984  8 หลายเดือนก่อน

      You should check first the water drain valve.

  • @Hardik_8918
    @Hardik_8918 ปีที่แล้ว +1

    Brother, can you share me the video of GA30+ model.
    We are facing issue as Our display controller sometimes hand or freeze and not able to load the pressure even at the set Level

    • @Hardik_8918
      @Hardik_8918 ปีที่แล้ว

      It will be grateful if I can contact you any way, can I have your contact number or email id for further discussion.?
      I like your maintenance work procedure.

    • @shipneer5984
      @shipneer5984  ปีที่แล้ว

      I'll try to make a video about it as well. Thank you Brother.

  • @ibrahimalrwishad3059
    @ibrahimalrwishad3059 ปีที่แล้ว

    I have a compressor that is overheating. The oil filter, seberitor filter, and thermostat valve have been changed, and the problem hasn't been resolved yet.

    • @shipneer5984
      @shipneer5984  ปีที่แล้ว

      Did you check the oil cooler?

    • @onedownclutchin2up
      @onedownclutchin2up ปีที่แล้ว +2

      How fast is it overheating? Is it immediately? A collapsed oil cooler line which is extremely rare can do that. Or more commonly if the thermal valve is installed incorrectly the pin doesn't have the plate to push off of so it actually doesn't open correctly.

    • @helderhernandez1525
      @helderhernandez1525 ปีที่แล้ว

      Para descartar le intercambiador deberás tocar las mangueras de entrada y salida del radiador y debes sentir la diferencia si unas está muy caliente y la otra no quiere decir q no está recirculando aceite x allí. Cómo también debes revisar si la válvula termostática está bien instalada. A pasado q el sentido de giro motor ventilador no es el correcto

  • @bmilewski
    @bmilewski ปีที่แล้ว

    Did he run compressor without oil for a while? 😮

    • @shipneer5984
      @shipneer5984  ปีที่แล้ว

      No~ friend. Final L.O. filling is top up.😆

  • @muhammadhanif-fz3wd
    @muhammadhanif-fz3wd ปีที่แล้ว

    How are you brother, please check Atlas copco Dryer FD1250+.
    Its Heat Exchanger that part number P1609001319.
    Inside this gas lekage can possible to repair it.