Pressure Testing Our Drain-Waste-Vent Pipes

แชร์
ฝัง
  • เผยแพร่เมื่อ 17 ม.ค. 2025

ความคิดเห็น • 25

  • @jackiehowes9092
    @jackiehowes9092 ปีที่แล้ว +1

    I love following your progress and enjoy how thorough you are. Can wait to see what the future holds for you youngsters ❤

  • @shawnfahey7243
    @shawnfahey7243 4 หลายเดือนก่อน

    I totally liked watching your review on the DWV testing.

  • @ibrahimmohammed4368
    @ibrahimmohammed4368 ปีที่แล้ว +1

    amazing....you are the best

  • @envoyabroad104
    @envoyabroad104 9 หลายเดือนก่อน

    Thank you!!!

  • @timbrown9305
    @timbrown9305 2 หลายเดือนก่อน +1

    I am 60 and I have never had any issue with teflon tape or pipe dope alone. Why together?

  • @lukekaz9
    @lukekaz9 5 หลายเดือนก่อน

    I get the adapter with threads and screw it into a clean out so I don’t need to glue it on

    • @MasonDixonAcres
      @MasonDixonAcres  5 หลายเดือนก่อน

      Very good idea - will steal that for the next build

  • @DarrylHamilton-dm1de
    @DarrylHamilton-dm1de 9 หลายเดือนก่อน

    Hey buddy where'd you find the yellow extension?

    • @MasonDixonAcres
      @MasonDixonAcres  9 หลายเดือนก่อน

      Supplyhouse.com as per usual

  • @VINODPVARGHESE
    @VINODPVARGHESE 10 หลายเดือนก่อน

    Good video

  • @chrisalister2297
    @chrisalister2297 3 หลายเดือนก่อน

    Isn't tape and pipe dope overkill? Shouldn't pipe dope be sufficient?

  • @robertbuck7186
    @robertbuck7186 8 หลายเดือนก่อน

    good job...

  • @bgd5339
    @bgd5339 ปีที่แล้ว

    If you only had one small leak, I would call that a success. 👍

  • @ChristopherBurger-m2s
    @ChristopherBurger-m2s 5 หลายเดือนก่อน

    A positive air pressure test is not allowed in the state of Connecticut. The only two acceptable options is a vacuum test or a water test. Some manufacturers may actually require you to replace all of your DWV pipes if you put an air test on the system. Please make sure to give your local jurisdiction a call.

    • @MasonDixonAcres
      @MasonDixonAcres  5 หลายเดือนก่อน

      Our area is either 5psi air or hydrostatic water, most jobs I've seen by plumbers in both residential and commercial settings use air

  • @johnf8877
    @johnf8877 ปีที่แล้ว

    I just got finished watching your AC video, have you considered the amount of room needed to install your stone between the AC unit and the wall. I am putting this here hoping that you see it instead of a month old video. It is hard to see with the camera angle in that video.

    • @MasonDixonAcres
      @MasonDixonAcres  ปีที่แล้ว +1

      Yep it should be okay, a little tight but about 30” I believe

  • @JTTTTx
    @JTTTTx 10 หลายเดือนก่อน

    Please remind your viewers that not all plumbing codes are the same.
    There are some jurisdictions that would fail you for the Fernco inside a building, air admittance valves anywhere on the installation and most importantly the wrong gauge used for the test-- must be a lower range attached to the system.

  • @jamesc1283
    @jamesc1283 ปีที่แล้ว

    I was curious so did a bit of googling and found this:
    "Fernco (Rubber) fittings are not approved in wall framing unless they have a metal sheathed hose clamp assembly covering the entire fitting as part of the design, Which limit them to straight couplings or reducing couplings. The reason is that vermin can chew through the rubber. They are suitable for underground but are more expensive than standard no hub couplings or regular pvc fittings. So the reason for wanting to use them for that is questionable unless there is some sort of access issue."
    So I doubt having that coupling in the wall would not be acceptable to your inspector. It sounds like the full-metal covered couplings are ok, and honestly based on the way that was bulging I'd think you'd want that anyway. I'm curious if your inspector already passed it though.

    • @jamesc1283
      @jamesc1283 ปีที่แล้ว

      And to not just be negative in comments, I've watched a few of your videos and I'm enjoying them so far!

    • @MasonDixonAcres
      @MasonDixonAcres  ปีที่แล้ว

      Thanks for the research! Is that in the IRC or where did you find that? I really can’t imagine a mouse chewing through that boot and not also chewing pvc wire insulation, PEX, etc. so I’m not too worried. The inspector did already pass it 😄 There’s no inlets above it so it should never ever be under that kind of pressure again (if the drain stops up, it will come out the utility room floor drain).

    • @stevestadterman9270
      @stevestadterman9270 ปีที่แล้ว

      believe or not,,mice/rats find the rubber more tasty,,@@MasonDixonAcres

    • @JohnFarrell-jo2sw
      @JohnFarrell-jo2sw 6 หลายเดือนก่อน

      Don’t know why he didn’t just redo the thing right and glue on anew couple of fittings and be done with it forever and not have to worry about it coming back to haunt him later on but hey that’s on him

  • @michaelvrbanac6923
    @michaelvrbanac6923 4 หลายเดือนก่อน

    You don't need both tape and dope. They act only as a lubricant.

  • @BOSS_805
    @BOSS_805 8 หลายเดือนก่อน

    Using air to pressure test PVC is a bad idea, positive air pressure is combustible and PVC drain lines are not ready for pressure which could in turn lead to an exploding sort of pipe bomb. Never exceed 5 PSI. Your best bet is to use negative air pressure AKA suction and watch your gauge to test for leaks. Next time just use it 4-in plug instead of that insert bladder thing