Hi Bon, Do you need to use Daikin's S-ISO adapter together with service checker for multi split. According to Daikin video, it says S-ISO adapter and external power supply are needed together with service checker when connecting with multi split. But that was an older video so I am not sure if the S-ISO adapter is needed anymore. Thanks.
Thank you very much for sharing your knowledge. daikin wireless adapter checking very expaincive around $400😮. But do very good job. Is it working for old module?
Hi Mr.Bon my dakin MKS80QVMG split 3 units. The problem is when on master bed rm other two rm not cooling.when off master bed rm other two cooling.service contactor check for 4 days remove gas vacuum n top up gas still the same. Boss needs your advice thks
Hi, I am having a L5 error code. When error L5 come 3 unit when on blinking yellow light and is not running, after resetting the isolation switch it can power up again and if I leave the isolation switch on rest of the day it will have the error again or sometimes it may not. technician suggested I to change the whole compressor which is so expensive
Master what's the problem error code says signal transmission error between two cpu outdoor unit the indoor always blinking the out door the green led always blinking but # 2 3 and 4 red light blinking but # 1 and 5 off led multi split ..3 indoors
Hello sir. May I know the name of your company.. i would like to write it down in my list of service provider just in case I need your world class service in the future.
Thank you for the extra efforts to shoot the video alone and showing us, wishing you all the very best🙏🏻
Welcome 🙏
I've been following your work all along. ❤ 🇹🇭
Thanks
@@BonMjsar where are you from
Your video all very very useful to us thank you sir.
Welcome
HI Bon , Watching from Yangon. Thanks for helping all video clip.
Welcome
Great video Uncle Bon. 👍
Thanks
Great job Mr bon.
Thanks
👏👏👏 Well Done Teacher
Thanks
Very good speaking ❤❤❤
Thank you the effort. I really appreciate ❤
You're welcome 😊
Thanks!forAnother day of knowledge 🎉🎉🎉
Welcome
Good job bro.🇹🇷🧿👍👍
Thanks
Hi Bon, Do you need to use Daikin's S-ISO adapter together with service checker for multi split. According to Daikin video, it says S-ISO adapter and external power supply are needed together with service checker when connecting with multi split. But that was an older video so I am not sure if the S-ISO adapter is needed anymore. Thanks.
Should no problem with out S-ISO
May be for some old model
@@BonMj Thanks!
Thank you boss
Welcome
Thank you very much for sharing your knowledge.
daikin wireless adapter checking very expaincive around $400😮.
But do very good job. Is it working for old module?
Not all, latest model
@@BonMj thank you for your reply 🙏❤️
@@BonMj hope next video you show us how you check Mitsubishi
Good Job!!😎🇧🇷
Thanks
Please make a video on how to test the daikin inverter. Concealed ac outdoor fan motor
THANK you
You're welcome!
Bon sir nice picture
Thanks😊
Hi sir new subs here..
Thanks
Tenks Mj Bon
Welcome
thanks sir Bon
Welcome
Hi Mr.Bon my dakin MKS80QVMG split 3 units. The problem is when on master bed rm other two rm not cooling.when off master bed rm other two cooling.service contactor check for 4 days remove gas vacuum n top up gas still the same. Boss needs your advice thks
May thermistor faulty or other issues
@BonMj yes, I found that two indoor thermistor measures show 24.25 k ohm
Thanks Sir
Welcome
Can we use this wireless adapter whit mono split unit ?
Should be ok
Is 16 hp control pcb work on 18 hp machine daikin vrv 3
hi mr bon could tell us please where we can find wireless adaptor thanks
Daikin
How much does Daikin checker cost in Singapore? It is too expensive in America.
May around S$300
You can check online too
That checker works for all units or only for daikin units?
Only for Daikin inverter and VRV
Daikin only, inverter and VRV
Hi, I am having a L5 error code. When error L5 come 3 unit when on blinking yellow light and is not running, after resetting the isolation switch it can power up again and if I leave the isolation switch on rest of the day it will have the error again or sometimes it may not. technician suggested I to change the whole compressor which is so expensive
May Pcb got problem
Hello sir I need your help how to shop Bluetooth wireless adapter my country not available so plz i need your help
From Daikin
good afternoon Sir.Bon JM how to apply Sir.i interested for work in your company as a AC TECH.
Master what's the problem error code says signal transmission error between two cpu outdoor unit the indoor always blinking the out door the green led always blinking but # 2 3 and 4 red light blinking but # 1 and 5 off led multi split ..3 indoors
Hello Teacher Bon, How much is the bluetooth checker?
Around S$300
First
Thanks🙏🙏👍👍
Hi Mr bon
Hi
棒棒的啊,多少钱这个checker
应该300左右
Hello sir. May I know the name of your company.. i would like to write it down in my list of service provider just in case I need your world class service in the future.
How can buy this in sg??
Daikin sg
Hello bro...
Hello