does it works same as smarten's Dod feature which doesnt work at night i.e. it will start charging from grid at night irrespective of the charge left in the battery, or this works differently?
Good information sir Mere pass 2.5 microtek normal inverter hai 24 v ka . Kya mai ashapower 80 neon charge controller kharid ke aur 2 batteries is par parallel laga sakta hu rat me jiyada backup ke liye . Please advise
Sir mere pass smarten ka inverter hai..lekin voc 85 hai isliye panels parrell connect nahi ho skte..agar me smarten ko as a normal inverter use kru aur jo usme grid charging disable option hai use kru to to day time me asha power batteries ko charge krega aur sath me solar se. Smarten ka load b chalaega..ya fir asha power sirf batteries hi charge krega aur smarten batteries se load chalaega..kehne ka maqsad hai batteries se load to ni chalega din me har time..kabi battries asha power se charge hoti rahe aur smarten use discharge krta rahe load chalake..
I really need your help regarding Ashapower, I have purchased surya 60 (HV) , I have a problem with it as at the evening when solar isn't available it disconnect mains to inverter at set point of GRID -SOL and as solar isn't available my battery voltage drops suddenly then it connects with main at set point of SOL- GRID ,can i know does of your happen like this even though solar green light is off?
I can't understand you questions dear Green light only show the presence of solar Grid to solar and solar to grid you can set manually as per your consumption
@@sandhuztech4465 thanks for reply My problem is when at evening solar unavailable( GREEN LIGHT OFF) at that moment my load is running over ( BLUE LIGHT ON) at point of GRID - SOLAR Why its happening even though solar is unavailable For this my battery voltage suddenly drops as solar unavailable and it disconnect grid
@@sandhuztech4465 my settings are Flot v - 13.6 Bulk v - 14.3 Grid -sol - 13.5 Sol - grid - 12.2 suppose my battery voltage 12.4 and my load were running over solar(blue on) as evening occurs solar unavailable (Green light off) my battery voltage drops to 12.2 so it activate sol to grid so now my battery voltage rises to 13.5 now at that moment it activate sol to grid even though solar is unavailable Then now my battery voltage again drops as solar unavailable
Sir ji night mein ye controller main par jane ke baad jo grid to solar voltage set ki hai uspar apny aap mains cut karta hai fir battery par fir main to ismey jyada power electricity cosume hoti hai
Sir mere pass luminous Solar 150 ah ki battery + 650w ke panel charge controller pe connected hai... To wo 12v 30 ampere se battery ko charge krta hai... Agr ghar ka load ho to koi dikt nhi.. Lekin load na ho to.... Ky 30 ampere se battery kharab hogi?
sir क्या 24volt वाले बेटरीयों को पेरलल करके 4 बेटरी लगा सकते ह या नही मेरे पास 400watt चार पेनल ह कुल 1600Watt लगे ह 2kva का pwm ईनवेटर ह 2 बेटरी लगी ह C10 , 200Ah की तो मुझे ये mppt चार्ज कंट्रोलर लगाना चाहिये sir आप अपना फोन. न. दे सकते ह मेरा समाधान करे
Raat me battry discharge hone per charging grid se hogi or subah tak full charge ho jayegi grid se to solar ka fayda kaise milega, ye to roz raat me hoga ? Grid charging disable karne ka koi tarika hai ? Kya inverter me.koi jugad ho sakti hai ?
Isiliye aap ko bada battery install karna padega jo ki raat me sab load ko chalake bhi kam nehi hoga. Grid charge disable hone se ye problem nehi rahega. Aur ek problem hai Asha power me battery charging agar limit hoga to load keliye bhi limited current available hoga.
Hello 👋 sir muje ik kanfeujan h man lo 2000w k panal h or 24v battery lagi h tab to J 60 amper ja 80 amper se charg kare ga jis se battery jaldi kharab ho jae ga
@@sandeepvashishta3732 dear agr aap ki battery 100ah ki hai to aap aapne panel ki power dekhne ke liye battery thori khrab kar lo ge so that you adjust your system as per requirement
Sir, Make a video A to Z with asha power surya 60 HV voc165 panels support 1600watts. I have surya 60 LV voc 140 panels support 1600watts and what's meaning LV & HV. Can I connect Shark solar panels 440watts 04 or 03 for 24v battery bank? I want to add more 02 battery 200ah, c10 in 24v parallel.
संधू सर सत श्री अकाल पाजी... र्कप्या मेर प्रश्न का उत्तर देन दा कष्ट करें 01. 300 ah की दो बैटरी, 330 वाट के दो सोलर पैनल के साथ आशापावर नीओन 80 चार्ज कंट्रोलर से सुबह 6 बजे से 12 बजे दोपहर तक ज्यादा से ज्यादा कितने प्रतिशत जार्ज हो सकती है? जबकि घर में लोड 10 एम्पीयर डीसी लगातार चल रहा है। क्योकि दोपहर 12 बजे के बाद घर का लोड 30- 35 डीसी एम्पीयर हो जायेगा। और फिर शायद शाम बजे तक बैट्री पूरी तरह से चार्ज ना हो पाये। 02. क्रप्या आशापावर नीओन 80 मे ऐसी सेटिंग बताने का कष्ट करें जिससे भीषण गर्मी के मौसम में सुबह 6 बजे से दोपहर 12 - 1 बजने के दौरान ( 5-6 घंटे) मे ज्यादा से ज्यादा बैटरी को चार्ज किया जा सके। क्योंकि ग्रिड सप्लाई बहुत कम है। 03. यदि संभव हो सके तो अपना कोई वास्टसएप नम्बर शेयर करने का कष्ट करें जिससे सोलर संबंधित समस्याओं का समाधान आपके अनुभव से ठीक कर सकें बहुत बहुत धन्यवाद महोदय 💐 आपका सब्सक्रईबर रविंद्र जायसवाल
Sir mere paas 12 volt system hai Kiya main ashapower nova 40 amp controller ke sath 3 battery parallel main laga sakta hu charge ho jayegi 150 ah ki battery
श्रीमान मेरे पास सूर्या 60 h। मैं grid connect नही किया हूं। पैनल से 45 amp आ रहा है लेकिन बैट्री को 30 amp se ऊपर नही दे रहा है। क्या सेटिंग ह की पूरा amp output ho जिससे लोड भी चले और बैटरी भी चार्ज हो। बताए।
Sir plz help Maine 150 ah ki 2 battery paralle main lagai hai agar Battery 11.2 ho morning main jab ashapower surya 60 charge krta hai to max 50 amp se krta hai But only 2 fan load chlta hai 900 watt solar hai fir bhi battery 5 pm tak only 13.5 tak aati hai but gravity nahi banti sirf 1100 Tak banti hai meri battery new hai to saara din 50 amp se charge hone ke baad bhi gravity kiyu nahi banti charge kiyu nahi hoti Jab ki aapki dono battery 11 am tak full ho jaati hai Help me sir Battery ko sirf 20 days hue hai bilkul new hai
If we limit the charging current for example say 30Amps, what happens when the inverter takes more than 30Amps as load requires? does this provide extra current at that time? or how does it know that extra current is being required? do you how these things work? thankyou
my settings are Flot v - 13.6 Bulk v - 14.3 Grid -sol - 13.5 Sol - grid - 12.2 suppose my battery voltage 12.4 and my load were running over solar(blue on) as evening occurs solar unavailable (Green light off) my battery voltage drops to 12.2 so it activate sol to grid so now my battery voltage rises to 13.5 now at that moment it activate sol to grid even though solar is unavailable Then now my battery voltage again drops as solar unavailable
If you want when solar is not available in night time your load running on grid There is two options 1. You can set solar to grid level voltage on high level which you want. 2. You can set bulk charging on 15v and AMP LT settings on 2 no. And maximum charging time till 50 amp
pura youtube me apka video very very helpful mila Sir.
Thank you so much Sir. aur vi video banaiye is jaisa
Presently the best explanation of the ASHAPOWER MPPT charge controller unit on TH-cam. Keep it up.
Can I use LiFePO4 battery with smart BMS along with this controller
Very knowledgeable video
If we are using single 150AH c20 battery. Then can we limit the charging current to max 15A all the time?
Battery ko equalising automatically hotahe..ya fir korna padtahe... ashapower mppt solar charge controller main...oour kitne din main hotahe
Can I use LiFePO4 battery with smart BMS along with this smu
Sir mere pass light connection nhi h to mai is control to pwm inverter ke sath connect kar sakta hu ki nhi
does it works same as smarten's Dod feature which doesnt work at night i.e. it will start charging from grid at night irrespective of the charge left in the battery, or this works differently?
Very good sir
Thank you for the effort.
Kitne time mai charge ho jati hai battery or 3 saal hone ke baad ap ki battery ka backup acha de rahi ya kuch damage hue battery?
Sir is mppt charge controller ka inverter ke sath connection kaise karte hai... Plz guide me sir.. plz isko connection diagram ke through samjhaye....
Good information sir
Mere pass 2.5 microtek normal inverter hai 24 v ka . Kya mai ashapower 80 neon charge controller kharid ke aur 2 batteries is par parallel laga sakta hu rat me jiyada backup ke liye . Please advise
Sir s mppt boost karte he kya
Sir setting ka video 24 v. Me bhi ek baar bna do please
Isme battery ka maximum cut off voltage set kar sakte hai??
Yes kar sakte hai
Sir mere pass smarten ka inverter hai..lekin voc 85 hai isliye panels parrell connect nahi ho skte..agar me smarten ko as a normal inverter use kru aur jo usme grid charging disable option hai use kru to to day time me asha power batteries ko charge krega aur sath me solar se. Smarten ka load b chalaega..ya fir asha power sirf batteries hi charge krega aur smarten batteries se load chalaega..kehne ka maqsad hai batteries se load to ni chalega din me har time..kabi battries asha power se charge hoti rahe aur smarten use discharge krta rahe load chalake..
Aap smarten ko as normal inverter use kar sakte ho or asha power se solar se battery charge sakte ho je dono Kam kare ge ethe
@@sandhuztech4465 dono matlab solar se battery b charge krega aur solar se load b chalaega
How many pannels of 330w. Total panel wattage please???
Sir Sabi utuob r mppt ko 12v battery k sath he video keo banate h 12v pe to amper jeada mele ge he 24v pe video banao fir pata chale ga
स्मार्ठनसेवर 2500का विडियो बनाओ
I really need your help regarding Ashapower,
I have purchased surya 60 (HV) ,
I have a problem with it as at the evening when solar isn't available it disconnect mains to inverter at set point of GRID -SOL and as solar isn't available my battery voltage drops suddenly then it connects with main at set point of SOL- GRID ,can i know does of your happen like this even though solar green light is off?
I can't understand you questions dear
Green light only show the presence of solar
Grid to solar and solar to grid you can set manually as per your consumption
@@sandhuztech4465 thanks for reply
My problem is when at evening solar unavailable( GREEN LIGHT OFF) at that moment my load is running over ( BLUE LIGHT ON) at point of GRID - SOLAR
Why its happening even though solar is unavailable
For this my battery voltage suddenly drops as solar unavailable and it disconnect grid
@@sandhuztech4465 my settings are
Flot v - 13.6
Bulk v - 14.3
Grid -sol - 13.5
Sol - grid - 12.2
suppose my battery voltage 12.4 and my load were running over solar(blue on) as evening occurs solar unavailable (Green light off) my battery voltage drops to 12.2 so it activate sol to grid so now my battery voltage rises to 13.5 now at that moment it activate sol to grid even though solar is unavailable
Then now my battery voltage again drops as solar unavailable
@@jayanarayan problem with your battery
Solar to grid means grid is charging your battery with inverter when battery voltage is = or below 12.2V. @@jayanarayan
Grid button off ya on rakhna hai
Hello bhaiya Mere asha power surya60 hai soler se jitna ampr aaraha hai utna hee de raha hai panels maine series me lagaye hain
Aap ne kaise measure kiya ?
Solar se aane wale amp display nahi show karta
Sir ji night mein ye controller main par jane ke baad jo grid to solar voltage set ki hai uspar apny aap mains cut karta hai fir battery par fir main to ismey jyada power electricity cosume hoti hai
th-cam.com/video/LEAeT2vsEts/w-d-xo.html
How to turn off Display Light of the controller , it's annoying at night ,
Please Help And Thanks
Sir mere pass luminous Solar 150 ah ki battery + 650w ke panel charge controller pe connected hai... To wo 12v 30 ampere se battery ko charge krta hai... Agr ghar ka load ho to koi dikt nhi.. Lekin load na ho to.... Ky 30 ampere se battery kharab hogi?
No nahi kharb ho gi
Sir is ke jo sateg h grid to solar menimum ketna kar sakte h ples reply me
12v
Can u make me a grid charging switch off for my ashapower neon 80 using on icruze 4500
During night, when solar power is not available, it shifts grid to solar when battery voltage gets more than grd to solar voltage?
Then its again take power form your batteries
Sir lithium battery charge kar sakta hai
No sir
@@sandhuztech4465 SIR AAPKA NO.. DIJIYE
sir क्या 24volt वाले बेटरीयों को पेरलल करके 4 बेटरी लगा सकते ह या नही
मेरे पास 400watt चार पेनल ह कुल 1600Watt लगे ह 2kva का pwm ईनवेटर ह
2 बेटरी लगी ह C10 , 200Ah की तो मुझे ये mppt चार्ज कंट्रोलर लगाना चाहिये sir आप अपना फोन. न. दे सकते ह मेरा समाधान करे
Kitne Watt ki palet h
Can I use smarten superb 2500 as a inverter only beside a asha power mppt charge controler?
Yes u can do
Thank you sir
Which model of asha mppt is best in low baget? Between 7 to 10 thousand?
Amp limited par video kab ayegi?
I can't understand that point
Jaldi hi banne gi
Video aa chuki hai
Kya ashapower mppt solar charge controller two amp se kam current par amp ko boost nehin karpati..
.... please reply
Ek do amp pe bhi kam karta hai
Raat me battry discharge hone per charging grid se hogi or subah tak full charge ho jayegi grid se to solar ka fayda kaise milega, ye to roz raat me hoga ? Grid charging disable karne ka koi tarika hai ? Kya inverter me.koi jugad ho sakti hai ?
Solar to grid voltage ko kam rakhiye...
Raat mn grid se charge nhi hoga ya minimal hoga
Isiliye aap ko bada battery install karna padega jo ki raat me sab load ko chalake bhi kam nehi hoga.
Grid charge disable hone se ye problem nehi rahega. Aur ek problem hai Asha power me battery charging agar limit hoga to load keliye bhi limited current available hoga.
Hello 👋 sir muje ik kanfeujan h man lo 2000w k panal h or 24v battery lagi h tab to J 60 amper ja 80 amper se charg kare ga jis se battery jaldi kharab ho jae ga
Amp ki limit aap set kar sakte ho mannually
@@sandhuztech4465
Amp ki limit kam kar denge to jyada panel lagaane ka kya fayda
@@sandeepvashishta3732 dear agr aap ki battery 100ah ki hai to aap aapne panel ki power dekhne ke liye battery thori khrab kar lo ge so that you adjust your system as per requirement
@@sandhuztech4465 भाई जी
Amp कम कर देंगे तो load ओर batt चार्ज एक साथ कैसे होगी,
बढ़ा देंगे तो कम लोड पर बैटरी खराब हो जाएगी
@@sandeepvashishta3732 sir je sab kush automatically hoga aap tention na le
Dear sir i want to connect my 4 x24 volt panels in series to get more higher ampere...
Its depends upon charge controller voc rang series connection much batter then parallel conection
Exide 300 ah 6 volt battery ke uper detailed video banaiye
Sir, solar kitne volt ka solar panel use kr rhe ho?
Sir,
Make a video A to Z with asha power surya 60 HV voc165 panels support 1600watts. I have surya 60 LV voc 140 panels support 1600watts and what's meaning LV & HV. Can I connect Shark solar panels 440watts 04 or 03 for 24v battery bank? I want to add more 02 battery 200ah, c10 in 24v parallel.
Hv means high voc and lv means low voc
Sir 24 volt baitry ki setting ka video bna do
Bana rakha hai smarton wala video dekho
Sir aap ke pass ongrid or offgrid dono system he na
Yes
संधू सर सत श्री अकाल पाजी...
र्कप्या मेर प्रश्न का उत्तर देन दा कष्ट करें
01.
300 ah की दो बैटरी, 330 वाट के दो सोलर पैनल के साथ आशापावर नीओन 80 चार्ज कंट्रोलर से सुबह 6 बजे से 12 बजे दोपहर तक ज्यादा से ज्यादा कितने प्रतिशत जार्ज हो सकती है? जबकि घर में लोड 10 एम्पीयर डीसी लगातार चल रहा है। क्योकि दोपहर 12 बजे के बाद घर का लोड 30- 35 डीसी एम्पीयर हो जायेगा। और फिर शायद शाम बजे तक बैट्री पूरी तरह से चार्ज ना हो पाये।
02. क्रप्या आशापावर नीओन 80 मे ऐसी सेटिंग बताने का कष्ट करें जिससे भीषण गर्मी के मौसम में सुबह 6 बजे से दोपहर 12 - 1 बजने के दौरान ( 5-6 घंटे) मे ज्यादा से ज्यादा बैटरी को चार्ज किया जा सके। क्योंकि ग्रिड सप्लाई बहुत कम है।
03. यदि संभव हो सके तो अपना कोई वास्टसएप नम्बर शेयर करने का कष्ट करें जिससे सोलर संबंधित समस्याओं का समाधान आपके अनुभव से ठीक कर सकें
बहुत बहुत धन्यवाद महोदय 💐
आपका सब्सक्रईबर
रविंद्र जायसवाल
Sir neon 80 ki greed..wairing. Kaise kare. Bataye
Did not understand what u say dear
If you buy 2kv inverter then you can run even 1 inverter ac. Otherwise fridge, water pump. Etc
No sir
My friend Iam using 2.2kv inverter with 1 ton inverter AC. V guard smart 2300 inverter is capable.
Sir mere paas 12 volt system hai
Kiya main ashapower nova 40 amp controller ke sath 3 battery parallel main laga sakta hu charge ho jayegi 150 ah ki battery
Yes but charging max 40amp se hogi
Or sir hum solar to grid maximum ketna kar sakte h
Net pe Ashapower ka user manual download kario us pe sab likha hai
16v
Equalising setting par vedio banao
Je equalise nahi karta sir
@@sandhuztech4465 uska settings main ek no 5 main ek options he battery equalising ki..
Fan ka sound jyada Aata hai kya
@@Shashikrsah fan ka sound to atta hai es mai
श्रीमान मेरे पास सूर्या 60 h। मैं grid connect नही किया हूं। पैनल से 45 amp आ रहा है लेकिन बैट्री को 30 amp se ऊपर नही दे रहा है। क्या सेटिंग ह की पूरा amp output ho जिससे लोड भी चले और बैटरी भी चार्ज हो। बताए।
Panel se jo 45 am p aate hai v kaise chak kya
What happens at night when solar is unavailable ,does it shift load to solar if battery voltage is high?
Its take voltage from battery till level of voltage which is set by you aol to grid
Sir plz help
Maine 150 ah ki 2 battery paralle main lagai hai agar
Battery 11.2 ho morning main jab ashapower surya 60 charge krta hai to max 50 amp se krta hai
But only 2 fan load chlta hai 900 watt solar hai fir bhi battery 5 pm tak only 13.5 tak aati hai but gravity nahi banti sirf 1100
Tak banti hai meri battery new hai to saara din 50 amp se charge hone ke baad bhi gravity kiyu nahi banti charge kiyu nahi hoti
Jab ki aapki dono battery 11 am tak full ho jaati hai
Help me sir
Battery ko sirf 20 days hue hai bilkul new hai
Thorha din or dekho gravity bann jaye gi
@@sandhuztech4465 thx
Sound is very loud when video start.
Mind it.
Sir isse accha to systellar ka mppt cc h full function
Mujhe full setting cheya aap ek aur vedio banaao setting ka full
Channel subscribe karo jaldi hi aye gi
Ok
If we limit the charging current for example say 30Amps, what happens when the inverter takes more than 30Amps as load requires? does this provide extra current at that time? or how does it know that extra current is being required? do you how these things work?
thankyou
Ongride me bill keya 00 yata he...
No 60 rs. Per watt load per fixed plus 10%total units thise you import from pspcl in a year aaye ga hi
@@sandhuztech4465 samja nehi. 3 month me kohi unit hehi liya to keya bill aye ga. ।।।westbangolme avi ongride chalu nehi hoya
my settings are
Flot v - 13.6
Bulk v - 14.3
Grid -sol - 13.5
Sol - grid - 12.2
suppose my battery voltage 12.4 and my load were running over solar(blue on) as evening occurs solar unavailable (Green light off) my battery voltage drops to 12.2 so it activate sol to grid so now my battery voltage rises to 13.5 now at that moment it activate sol to grid even though solar is unavailable
Then now my battery voltage again drops as solar unavailable
On set level 13.5 grid to sol mode active and but actually solar is not available then its take power from your battery till voltage 12.2
If you want when solar is not available in night time your load running on grid
There is two options
1. You can set solar to grid level voltage on high level which you want.
2. You can set bulk charging on 15v and AMP LT settings on 2 no. And maximum charging time till 50 amp
@@sandhuztech4465 thank u so much sir
May be it doesn't happen in absence of solar. If such a situation will be happened then what is the benifit of installing this controller.
@@learnandcreation3744 it occurs even at night
Pannel kitne watt ka hai sir...
330w
@@sandhuztech4465 kitne pannel hain. Total wattage please...
@@tariquemohammad4572 2
@@tariquemohammad4572 660w
यह एम्पियर मीटर ac h ya dc
Dc
Kisi ko second hand lena h to mere pass neon 80 lv hai dena chahta hu
Efficiency 70%
How
Setting mood is very bad 👎
Please help me
Apka koi video nahi aa raha
Sir thora busy chal raha hu jaldi hi aye ga g
Bhai iska great wala Jo wiring hai solar charge controller hai vah kaise hota hai Jara apna number WhatsApp pura do na
Sir setting ka video 24 v. Me bhi ek baar bna do please
Sir 24 volt baitry ki setting ka video bna do
Sir 24 volt baitry ki setting ka video bna do