Simple Mechanical System in Revit Tutorial

แชร์
ฝัง
  • เผยแพร่เมื่อ 7 ก.พ. 2025
  • Complete Revit Courses: balkanarchitec...
    Project files: / balkanarchitect
    Subscribe for more!
    Please Like this Video!
    In this tutorial I show you how to model an MEP HVAC system in revit.
    Revit Shortcuts:
    GR - Grid
    RE - Scale
    CL - Structural Column
    MM - Mirror (pick axis)
    UN - Project Units
    WA - Wall
    CS - Create Similar
    RP - Reference Plane
    Al - Align
    TR - Trim/Extend
    AR - Array
    CO - Copy
    TX - Text
    LI - Model Lines
    DL - Detail LInes
    Additional Tags: MEP, mechanical, HVAC, Ventilation, system, duct, air vent, family, Structural, Beam, Column, Beam System, Light, family, family editor, street light, Revit, Architecture, House, Reference Plane, Detail Line, Floor,, BIM, Building Information Modeling. Building, Roof, Roof by element, Roof by extrusion, How to model a roof in revit, Revit City, Revit 2018, Revit Turorials, Revit 2017, Revit Autodesk, Revit Architecture 2017, Revit Array, Render, AutoCAD, How to model in Revit, learn Revit, Revit Biginner tutorial, Revit tutorial for Beginner, Revit MEP, Revit Structur

ความคิดเห็น • 168

  • @stk57thst
    @stk57thst 3 ปีที่แล้ว +24

    1 year experience here: this video is excellent! After you watch this video, watch a ductwork sizing calculation video, then come back to this and youre almost there...

  • @harrylee3434
    @harrylee3434 5 ปีที่แล้ว +8

    most useful HVAC video on youtube

  • @mounderbellal9368
    @mounderbellal9368 6 ปีที่แล้ว +11

    You do well man, your tutorials are amazing, very clear, accurate and very very useful.

  • @jeromesmith6152
    @jeromesmith6152 6 ปีที่แล้ว +2

    Balkan ur're great, thanks keep doing what you do; a lot of people benefit from ur efforts.

  • @LittleOrphanAidsie
    @LittleOrphanAidsie 5 ปีที่แล้ว +23

    A fan coil or split system would be a better fit for this building.
    You want the Supply Air near the windows and doors, Return In the middle. With that t bar ceiling you don’t need to duct the R/A back to the unit. The attic acts as a return plenum. The duct and air handler need to be hung higher, allowing a smoother radius in the flex to the register. Also, this system could be installed with spiral duct (round), making it much cheaper to produce.
    The office needs S/A & R/A as well. The bathroom needs Exhaust and either a supply drop or a transfer duct from the office.

    • @zabba7461
      @zabba7461 5 ปีที่แล้ว +1

      Would you mind breaking down exhaust, supply drop, and transfer duct please?

    • @whatevr100
      @whatevr100 5 ปีที่แล้ว +3

      @@zabba7461 you will typically have an uninsulated exhaust duct in each restroom that will rise up through the roof via variable drive exhaust fan.
      A supply drop is just a ducted runout coming from your supply main to provide fresh conditioned air to the bathroom.
      A transfer duct that was mentioned is typically a return air boot above ceiling. That is just an open duct on both ends that penetrates the wall between rooms to allow for the air in the attic space (above ceiling) to move freely between rooms. This also allows rooms to relieve positive pressure caused by the supply air going into the room.

    • @dacoobob
      @dacoobob 3 ปีที่แล้ว +3

      it's a Revit tutorial not an HVAC design tutorial lmao

    • @Stalkerfiveo
      @Stalkerfiveo 2 ปีที่แล้ว +1

      @@dacoobob he literally asks for feedback @:47

    • @NewJill2024
      @NewJill2024 5 หลายเดือนก่อน

      amazing! better if we have the visuals for this.

  • @gl3ddesignandassemblinginc882
    @gl3ddesignandassemblinginc882 6 ปีที่แล้ว

    Very good job, its very good to be flexible, do not stop from teaching the world, you may be from a different country but good deeds and attitudes are universal

  • @Lichfeldian--Suttonian
    @Lichfeldian--Suttonian 4 ปีที่แล้ว +9

    Great video. Nice and clear.
    I _am_ one of those MEP people and I am struggling to draw ducts in directions other than in the XY plane: I am trying to get the supply and extract/return ducts to bend to two different vertical offsets, but I am yet to get the success of this just as I can with AutoCAD MEP.
    It’s driving me nuts!

  • @berberkerkhof7448
    @berberkerkhof7448 8 หลายเดือนก่อน

    Thankyou so much for this video, I think it's maybe even better that you are not an expert so I can follow you better as a beginner 😊

  • @dondiedanamoroto1761
    @dondiedanamoroto1761 4 ปีที่แล้ว +3

    return & supply diffuser must align to the ceiling grid for architectural view. :) I Must say well done and more MEP videos please.

  • @pierredib9353
    @pierredib9353 6 ปีที่แล้ว +6

    Thanks a lot sir , waiting anxiously for some electrical tutorials

  • @andrearantes5171
    @andrearantes5171 6 ปีที่แล้ว +18

    Perfect. Can you do an electrical plan...I would love to see how you do it. Thank you

  • @andrewroyepazaro9090
    @andrewroyepazaro9090 2 ปีที่แล้ว +1

    hey man can you please do a video a landscape design..with additional houses, stairs and pathway..the last one that I saw from you, you started from the middle...

  • @yayitsjepoy
    @yayitsjepoy 5 หลายเดือนก่อน

    Thank you for the tutorial!

  • @BOLTINGSK8ER
    @BOLTINGSK8ER 4 ปีที่แล้ว +6

    The flex duct needed a minimal length, that's why it wouldn't let you draw it that close.

    • @zaneraza4044
      @zaneraza4044 11 หลายเดือนก่อน

      is this a general HVAC thing or a software thing? aka: is the minimal length of the flex duct the same as it would be in real life?

    • @hummingbird5964
      @hummingbird5964 2 หลายเดือนก่อน

      @@zaneraza4044 has to be both. making that close of ducts would leave you with minimal room for air to let in easily.

  • @dimitardimitrov9958
    @dimitardimitrov9958 6 ปีที่แล้ว +7

    Thank you for the nice clear video, but if you permit me I would like to correct one big mistake:
    The "in" of your VAV where suppose to comes the inlet air from the AHU you have connected to the Air terminals instead of the correct duct "out" which is rectangular and stay unused.
    Keep doing your videos, they are amazing!
    Regards from another Balkan man! ;)

  • @unnikrishnanr8099
    @unnikrishnanr8099 4 ปีที่แล้ว

    Superb.. Very helpful❤️❤️

  • @atkinsvijay
    @atkinsvijay 4 ปีที่แล้ว

    Excellent...well demonstrated

  • @farllon
    @farllon 6 ปีที่แล้ว +3

    thanks, more Mechanical System please.

  • @tendupadala5090
    @tendupadala5090 2 ปีที่แล้ว

    well explained thank you sir .excellent

  • @omartamer1988
    @omartamer1988 9 หลายเดือนก่อน

    Thank you Balkan

  • @Arqbrunao
    @Arqbrunao 3 ปีที่แล้ว

    Wow, amazing

  • @sandrahegedus3950
    @sandrahegedus3950 2 ปีที่แล้ว +2

    This is great. I took the plumbing course, extremely helpful. Could you do a more extensive HVAC class? Thank you.

    • @TheRevitMagician
      @TheRevitMagician 9 หลายเดือนก่อน

      What would you like to see in an extensive HVAC class?

  • @hyderali440
    @hyderali440 6 ปีที่แล้ว

    It's use full & nice video

  • @lindbl0m
    @lindbl0m 2 ปีที่แล้ว

    nice video. thank you

  • @bimskool
    @bimskool ปีที่แล้ว

    you actually want to create a system out of the air terminals first, then connect the system to the VAV, then draw the duct. Same worfllow as electrical.

  • @SirKombabomba
    @SirKombabomba 6 ปีที่แล้ว

    Very helpful indeed!

  • @amirlatifi4631
    @amirlatifi4631 3 ปีที่แล้ว

    Thanks for great educational videos all these years.🙏
    I would appreciate if you could highlight cursor

  • @amirahwahab
    @amirahwahab 6 ปีที่แล้ว

    great work.

  • @drew9923
    @drew9923 2 ปีที่แล้ว

    When you say architects don't know about mech systems. Maybe you don't, but architects who are worth their money do.

    • @arialynch172
      @arialynch172 10 หลายเดือนก่อน

      It’s just not something most schools ever teach.

  • @skyrayplays8014
    @skyrayplays8014 3 ปีที่แล้ว

    Perfect

  • @Vusal_Abbasov_3D
    @Vusal_Abbasov_3D 4 ปีที่แล้ว

    Thank you so much, so amazing explaination

    • @ReactDanish539
      @ReactDanish539 4 ปีที่แล้ว

      All detail revit lecture step by step
      Follow me channel

  • @mohammedosmanjaveed6529
    @mohammedosmanjaveed6529 3 ปีที่แล้ว

    Can you please suggest the best tutorial or channel that makes videos on electrical.

  • @kishorekumar-tp1kq
    @kishorekumar-tp1kq 2 ปีที่แล้ว

    Thanks sir

  • @Lumeos19
    @Lumeos19 6 ปีที่แล้ว +2

    More MEP videos please!

  • @AkshayPatel-l1d
    @AkshayPatel-l1d 6 หลายเดือนก่อน

    can we have more tutorial ? Thanks for this

  • @alinanaaz6730
    @alinanaaz6730 6 ปีที่แล้ว

    Keep continue

  • @ahmedanwar4511
    @ahmedanwar4511 6 ปีที่แล้ว

    Thanks appreciate your effort

  • @costheta2
    @costheta2 2 ปีที่แล้ว

    GREAT

  • @TheResn8r
    @TheResn8r 2 ปีที่แล้ว +1

    Just remember not to use flex duct on your return ductwork ;)

  • @tendupadala5090
    @tendupadala5090 2 ปีที่แล้ว

    this video is for mep or architecture or structural?

  • @alexandersalinas6538
    @alexandersalinas6538 6 ปีที่แล้ว +1

    So for one interior bay you only need one supply & one return branch? Also if you have a longitudinal supply branch doesn’t it get smaller after each supply flex disburses ?

  • @randomcomment2177
    @randomcomment2177 5 ปีที่แล้ว

    Thanks!

  • @satishchinna8789
    @satishchinna8789 6 ปีที่แล้ว

    Thank u 😊

  • @nitzanaloni7768
    @nitzanaloni7768 6 หลายเดือนก่อน

    Hello, Im working with revit and trying to aply Mechanical Equipment. and when I click on that I get a message: Mechanical Equipment family is loaded. And as far as I know there is a basic package that should come with the software. How and where can I get the basic package that should come with the software?

  • @klkw19997
    @klkw19997 5 ปีที่แล้ว +1

    YOU ARE A FKING G. THANKS SO MUCH FOR THE VIDEO

  • @hiphop74100
    @hiphop74100 5 ปีที่แล้ว +1

    a vav is not a air unit, it is just a air distributor you should use an RTU or AHU .

    • @ReactDanish539
      @ReactDanish539 4 ปีที่แล้ว

      All detail revit lecture step by step
      Follow me channel

  • @vigneshwaran7139
    @vigneshwaran7139 5 ปีที่แล้ว

    nice bro we need more MEP videos

  • @syedshakeeb97
    @syedshakeeb97 7 หลายเดือนก่อน

    Where can I find the revit link "Auto Repair Shop", So that I can link and work on it

  • @jonhjosephperez
    @jonhjosephperez 11 หลายเดือนก่อน

    how to setup for a small scale area like a split type

  • @ertarunverma4111
    @ertarunverma4111 6 ปีที่แล้ว

    Thank you

  • @Grenmaju666
    @Grenmaju666 ปีที่แล้ว

    As for a tutorial for placing mechanical equipment, ductwork, and air terminals, this is decent. However you showed some techniques which display a misunderstanding of the way Revit works: (1) the ductwork cannot be stretched like you did at 6:30 (notice that it did not convert the elbow into a tee, it just overlapped a straight duct across the, now disconnected, elbow) and (2) I'm 90% sure you drew the supply duct from the outside air connection on the air handler (at 6:11 the connectors show that air flow on the left 2 are "in" and the air flow on the right is "out".
    If I could give a rating, it'd be probably a 3/5 but I had to give a thumbs down for missing those key features of MEP design in a tutorial.

  • @markblair9195
    @markblair9195 ปีที่แล้ว

    Hi Sir Thanks for this but question how do you change duct sizes like reducer making smaller ducts from bigger ones

  • @elsebethnathalietuxenwissi72
    @elsebethnathalietuxenwissi72 11 หลายเดือนก่อน

    Where do you have all your ME families from? - I am working in revit 2024, and it ask med for families in all the MEP functions.

  • @rakeshranjan7525
    @rakeshranjan7525 3 ปีที่แล้ว

    Nice

  • @haulankhup
    @haulankhup 2 ปีที่แล้ว

    how to create only flex duct as the whole system?

  • @LearningForum
    @LearningForum 6 ปีที่แล้ว

    very well done keep it up...
    Nice work....
    make a tutorial of cieling design...
    How to make design in cieling...
    Very good work and very informative videos...
    Thank you sir...

  • @arslandylan9769
    @arslandylan9769 5 ปีที่แล้ว

    l'accent a la française !
    good works

  • @dewetbritz5715
    @dewetbritz5715 2 ปีที่แล้ว

    I was cringing till you said it and then i felt better

  • @syedatiqabbas5036
    @syedatiqabbas5036 6 ปีที่แล้ว

    Great really great plz keep on , and water supply and electrical wiring also upload how it doing plz plz I love you Balkan

  • @HAMEEDKHAN000
    @HAMEEDKHAN000 4 ปีที่แล้ว

    Bhai jan revit 2016 ki templates aur family ki setting kaise karen age usme HVAC ka kam karo to air terminal, macanical equipment nhi ate hai bahi jaan

  • @mohammadzamin4924
    @mohammadzamin4924 6 ปีที่แล้ว

    Very nice. Can you share a video about LODs? How does that work?

  • @omarbazrto7682
    @omarbazrto7682 ปีที่แล้ว

    if I modified my architecture project dose it modified in mechanical template too??

  • @rajkgupta9276
    @rajkgupta9276 2 ปีที่แล้ว

    Can you adjust the rectangular duct

  • @cwang4ever
    @cwang4ever 5 ปีที่แล้ว

    I am your Patreon subscriber. My question is for single family unit. Can you show the whole process if possible 1. Electrical connection from outdoor A/C compressor unit to the house. 2. The attic furnace unit connection. 3. The connection from the outdoor utility company's surface electrical pole to the house? Thank you.

  • @lucaskalkmann9877
    @lucaskalkmann9877 6 ปีที่แล้ว

    thanks alot

  • @fatimemermerci6223
    @fatimemermerci6223 6 ปีที่แล้ว +2

    hi, my interface doesnt look like yours. i dont see other discipline together or sub discipline in project browser: mechanical +hvac etc.. please help me. thanks for all tutorials and generosity.

    • @FogTop
      @FogTop 4 ปีที่แล้ว

      Have you find solution, I've same problem now?

    • @thetaunters3052
      @thetaunters3052 4 ปีที่แล้ว

      Have you selected the right template?

  • @arashhosseini1073
    @arashhosseini1073 3 ปีที่แล้ว

    When I try to connect the duct to return to the diffuser (The pink color), I get the following error: The element you are trying to connect to has a different system classification. Does anyone know what should I do about it?

  • @omidsharif3189
    @omidsharif3189 6 ปีที่แล้ว +2

    THANK YOU FOR YOUR AMAZING TUTORIAL
    CAN YOU MAKE A VIDEO FOR SERVICE CORE OF HIGHRISE BUILDING

  • @walterjr80
    @walterjr80 6 ปีที่แล้ว +1

    Wonderful.
    Can you do a basic electrical and hydraulic (piping) system?

  • @afeezj4130
    @afeezj4130 6 ปีที่แล้ว +1

    Nice video but how do you determine the number of diffuser and return in a zone or space.

    • @LittleOrphanAidsie
      @LittleOrphanAidsie 5 ปีที่แล้ว

      Afeez J the amount of CFM the room requires divided by the amount of registers...

  • @slug182
    @slug182 6 ปีที่แล้ว +3

    Could you make a tutorial about schedules?

  • @bipuray3652
    @bipuray3652 4 ปีที่แล้ว

    Great

  • @bharathichowdary564
    @bharathichowdary564 6 ปีที่แล้ว

    Please to maintaining the visibility of the video

  • @24SevenMarketing
    @24SevenMarketing 6 ปีที่แล้ว +1

    Great ... now you have a basic system installed can you show us how you connect it to the analysis program and calculate the final sizes and air flow volumes? ... I'm trying to figure out a proper work flow for mechanical ... plumbing ... and electrical drawing parts of construction projects ... your tutorials are always so clear and easy to follow so I'm hoping you can help me get my basics workflows set up

    • @EchoMirage72
      @EchoMirage72 6 ปีที่แล้ว +1

      24SevenMarketing I work in mep all day if you'd like I can help you out some

    • @igormuniz88
      @igormuniz88 6 ปีที่แล้ว

      banderson470
      Hi, I work with MEP but i need help in same things, Can you help me ?
      Tks

    • @EchoMirage72
      @EchoMirage72 6 ปีที่แล้ว +1

      Igor Muniz yup I can help. Let me know what you need

    • @igormuniz88
      @igormuniz88 6 ปีที่แล้ว +1

      banderson470 Great !!!
      Give me your e-mail and i'll send a mensage.

    • @memyadventures2730
      @memyadventures2730 6 ปีที่แล้ว

      Sir make a video for that, it will help me alot

  • @sauravsharma2617
    @sauravsharma2617 6 ปีที่แล้ว

    We need more MEP videos
    ps this one was good

  • @hamizahzaini6899
    @hamizahzaini6899 3 ปีที่แล้ว

    where can i get that m_supply diffuser

  • @michaelshonclark
    @michaelshonclark 4 ปีที่แล้ว +1

    Your fundamentals of drawing are fine but you selected the wrong piece of HVAC equipment also, you tied your supply air into the primary air side of the VAV it should be on the other secondary side of the VAV. VAV's have to be fed by a larger air handling unit. The larger air handling unit will feed as many as 20 VAV'S. Some large facilities we have done may have up 30 large air handling units and 500 VAV boxes.

  • @musicbythebrain
    @musicbythebrain 6 ปีที่แล้ว +1

    Could you do one in Electrical on a commercial Building?

  • @karya1636
    @karya1636 4 ปีที่แล้ว

    how to add more plan view in floor and ceiling

  • @kevinhicks9447
    @kevinhicks9447 6 ปีที่แล้ว +2

    Would be good to show sun analysis, etc. in revit

  • @harshadkondalkar1502
    @harshadkondalkar1502 4 ปีที่แล้ว +1

    How you finalize location of duct is there any standard dimension we have to maintain from wall or other unit of HVAC.
    OR
    It is just free style work all we need to maintained symmetry

    • @ReactDanish539
      @ReactDanish539 4 ปีที่แล้ว

      Follow me channel All detail revit lecture step by step

  • @mohdayaz1212
    @mohdayaz1212 5 ปีที่แล้ว

    please make more videos on building services.

  • @hsaddok
    @hsaddok 6 ปีที่แล้ว +2

    I didn't find the Revit File in your link ?????

  • @jhownicolas
    @jhownicolas 6 ปีที่แล้ว +4

    Very helpful !
    Could you do some tutorial on electrical installation?
    Thanks a lot!

  • @alinanaaz6730
    @alinanaaz6730 6 ปีที่แล้ว

    Sir ur do wery well

  • @sweethumanissmsubbu592
    @sweethumanissmsubbu592 3 ปีที่แล้ว

    Any job opportunity for this course

  • @yasinege
    @yasinege 5 ปีที่แล้ว

    where the hell is the plenum boxes before the diffusers

  • @darrelnorton5826
    @darrelnorton5826 2 ปีที่แล้ว

    let's do some examples of house HVAC systems.

  • @marwaomar2395
    @marwaomar2395 4 ปีที่แล้ว

    how to automatically create duct openings through the walls?

  • @joshuawong7535
    @joshuawong7535 4 ปีที่แล้ว

    Hi Sir, Where can i get the auto repair project file

  • @sombatkrasethep
    @sombatkrasethep ปีที่แล้ว +1

    ขอบคูณครับ

  • @hef12180
    @hef12180 3 ปีที่แล้ว

    Where did you get the Mechanical Template?

  • @DiiezMiizNiiz
    @DiiezMiizNiiz 5 ปีที่แล้ว

    Please request a file to make an example to practice. , Thanks.

  • @michelantony8803
    @michelantony8803 6 ปีที่แล้ว +1

    Sir, how to connect the duct into 1st floor to 2nd floor wd one AHU

    • @baechu3108
      @baechu3108 5 ปีที่แล้ว +1

      I have the same problem!

    • @FogTop
      @FogTop 4 ปีที่แล้ว

      Have you find your problem? If yes then how?

    • @thetaunters3052
      @thetaunters3052 4 ปีที่แล้ว +1

      Every floor, has it's own AHU. There is no such ducting possible!

  • @xcuted_rizwan_1670
    @xcuted_rizwan_1670 5 ปีที่แล้ว

    Very good. Nice video can you help me sir I want to learn

  • @adityapkumar4147
    @adityapkumar4147 4 ปีที่แล้ว

    how edit it , after linking ,
    not able to edit the model ,
    anyone with any suggestion.........

  • @monissshaikh2162
    @monissshaikh2162 6 ปีที่แล้ว

    Do you have any solution for preparing Revit integrated duct work fabrication CNC drawings?

  • @binhsharingan9537
    @binhsharingan9537 6 ปีที่แล้ว

    Structure 😘😘

  • @Sanka4761
    @Sanka4761 6 ปีที่แล้ว

    Supeerb

  • @AymenHumoodi
    @AymenHumoodi 6 ปีที่แล้ว