What Will Happen if Transformer Neutral Supply Brake

แชร์
ฝัง
  • เผยแพร่เมื่อ 8 มิ.ย. 2023
  • What Will Happen if Transformer Neutral Supply Brake
    In this video, we will discuss what will happen if the neutral supply of the transformer fail near to our home
    Watch the complete video to learn more in details
    Thank You
    Arun Gupta
    Electricaltechnician02@gmail.com
    ══════⊹⊱≼≽⊰⊹═════════⊹⊱≼≽⊰⊹══════
    Hindi Channel @Electrical Technician
    / electricaltechnician
    2nd Channel @electrical Wiring School
    / electricalwiringschool
    Short Video @electrical technician Shorts
    / @electricaltechnician02
    TELEGRAM :
    telegram.dog/ElectricalTechnic...
    FACEBOOK : @electricaltechnical
    / electricaltechnical
    INSTAGRAM : @electricaltechnician02
    / electricaltechnician02
    ══════⊹⊱≼≽⊰⊹═════════⊹⊱≼≽⊰⊹══════
    My gadgets for TH-cam 📺
    Camera 📸 For video Recording
    amzn.to/3z3W9XM
    Mic 🎤 For Sound Recording
    amzn.to/3kpUyaK
    Tripod Stand
    amzn.to/3BajZmn
    Overhead Stand For Recording
    amzn.to/3z1rzhm
    ══════⊹⊱≼≽⊰⊹═════════⊹⊱≼≽⊰⊹══════
    You Should watch this videos too
    Amp to Watt Calculation in Electrical system
    • Amp to Watt Calculatio...
    Capacitor Value to Save Electricity Bill
    • Capacitor Value to Sav...
    Cooling Methods Used for Transformer
    • 7 Most Effective Type ...
    #transformer #electrical #interview #electrician

ความคิดเห็น • 25

  • @simonmaina2557
    @simonmaina2557 ปีที่แล้ว +2

    You are so knowledgeable my friend God bless you

  • @AnasAl-Dhafiri
    @AnasAl-Dhafiri ปีที่แล้ว +1

    Many thanks for your useful videos

  • @kaundabwalya7776
    @kaundabwalya7776 ปีที่แล้ว

    Keep them wonderful Videos coming Sir 👍.. & May GOD Bless you 🙏

  • @mohamedriyaz4545
    @mohamedriyaz4545 ปีที่แล้ว +1

    Well explained

  • @patrickmbalame5534
    @patrickmbalame5534 ปีที่แล้ว

    Keep up good work sir

  • @harshthacker8627
    @harshthacker8627 ปีที่แล้ว

    You get new Electrical sub bro...
    Great explanation...

  • @sheeteeshdansena7521
    @sheeteeshdansena7521 ปีที่แล้ว

    Very nice

  • @SiyaiDuanyoDavid
    @SiyaiDuanyoDavid หลายเดือนก่อน

    🎉

  • @zaacdozaacdo7004
    @zaacdozaacdo7004 ปีที่แล้ว

    Very nice bro

  • @noelfaithfulkari2857
    @noelfaithfulkari2857 ปีที่แล้ว +1

    Thank you sir. Could you do a video on transformer sizing for 200homes

  • @purushoth9053
    @purushoth9053 11 หลายเดือนก่อน

    Very clear explain for beginner in electrician, my role maintenance electrician so basic troubleshoot methods can you explain please sir.

  • @bamideledauda2447
    @bamideledauda2447 11 หลายเดือนก่อน +1

    Pls can you do full detail tutorial on conduit pipe laying for building and distribution of wires to circuit breaker. Thks

  • @johnkiran3306
    @johnkiran3306 หลายเดือนก่อน

    And please explain how the impedance will be different across houses. I mean if yellow house has all devices off at the moment. What will be the impact

  • @DH-tv2yw
    @DH-tv2yw 2 หลายเดือนก่อน

    Would the house with low voltage also suffer damage? E.g. motors that labour and overheat?

  • @johnkiran3306
    @johnkiran3306 หลายเดือนก่อน

    Please tell the protective measures as well

  • @pankajsonu3768
    @pankajsonu3768 ปีที่แล้ว

    Sir,
    How can we find resistance of a House

  • @2010bolte
    @2010bolte 11 หลายเดือนก่อน +1

    Thank you, but
    I thought that phase to phase would be 400V at a phase angle of 120 degrees. In stead of 415V.

  • @montatharhayder
    @montatharhayder 5 หลายเดือนก่อน

    If i have a device in my house works on 3 phases and the neutral break down from the transformer, does this device will damaged too?

    • @temp06j723-pmeighttq
      @temp06j723-pmeighttq หลายเดือนก่อน

      Depends if the Device/Equipment is tailored for 3Ø supply ?
      Eg 3Ø ∆ Motor will work fine but if any Control circuitry that runs on Single Phase Eg PSU/contactor will probably get damaged.
      To consider also if that Equipment all-together is protected by any means of Overvoltage Protection devices.

    • @30mAkills
      @30mAkills 25 วันที่ผ่านมา

      Broken neutral cannot damage 3 phase devices.

  • @echenduconfidence4998
    @echenduconfidence4998 10 หลายเดือนก่อน

    What if you link ur earth to neutral bar. From TT to t n c s.what will happen

    • @temp06j723-pmeighttq
      @temp06j723-pmeighttq หลายเดือนก่อน +1

      It it NOT for you to simply "link" your own TT Earthing to N-bar to make it so called TNCS🚫
      TNCS is defined by the Integrity of the PEN Supplied by the Electricity Supplier deemed fit to be used as "Protective Earthing" within Premises.

    • @temp06j723-pmeighttq
      @temp06j723-pmeighttq หลายเดือนก่อน

      If you are Adding a Supplementary Earthing (by adding Local earthing rods to Strengthen the PME network) to your TNCS supply, that is another different story.

    • @30mAkills
      @30mAkills 25 วันที่ผ่านมา

      Assume your earth electrode is corroded or no continuity. You don't know this as the linked neutral was acting as earth. One fine day your service neutral floats. Now no neutral no earth. In this scenario all your appliances will not work. But the metal bodies will get energized due to looping. (phase to neutral to earth to metal bodies). You touch your fridge and die! Hope this helps.