Diesel generator Training for Begginers n Expert level - Engine hunting , governor connection

แชร์
ฝัง
  • เผยแพร่เมื่อ 28 พ.ย. 2022
  • Diesel generator Training for Begginers n Expert level - Engine hunting , governor connection
    #dieselgenerator #training #engineering
    Best technical video tutorials
    1. Dse 7320 full course video tutorial
    lnkd.in/dCPHvrk
    2. How to read Electrical Drawings Video tutorial
    lnkd.in/g8v6BEG
    3.how to bypass generator AVR
    lnkd.in/dP6Xn-Kd
    4. Three phase genrator excitation system video tutorial
    lnkd.in/dE8ZDz3
    #generator #dieselgenerator #generators #Electricgenerator #electricalengineering #electricalengineers #Engineering
    #Electrical #techjobs #technicalsupport
    DSE Programming in Urdu/Hindi Chapter -1
    Video Link: • DSE generator controll...
    DSE Programming in Urdu/Hindi Chapter -2
    Video Link: • How to do basic config...
    DSE Programming in Urdu/Hindi Chapter -3
    video Link: • DSE program Urdu /Hind...
    DSE Programming in Urdu/Hindi Chapter -4
    • DSE program Urdu /Hind...
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 109

  • @DieselGeneratortraining
    @DieselGeneratortraining  ปีที่แล้ว +2

    1. Dg operator practical training
    th-cam.com/video/T77bZHVUAXM/w-d-xo.html
    2.Plc industrial automation free video tutorial course
    th-cam.com/video/hk1WTmLujrA/w-d-xo.html
    3. Dse 7320 full course video tutorial
    th-cam.com/video/bsZ8875Xo58/w-d-xo.html
    4. How to read Electrical Drawings Video tutorial
    th-cam.com/video/IHHCT43sdYM/w-d-xo.html
    5.how to bypass generator AVR
    th-cam.com/video/JzuFHKMkKyA/w-d-xo.html
    6. Three phase genrator excitation system video tutorial
    th-cam.com/video/Y5jshFwHCvk/w-d-xo.html

    • @kaderkader2947
      @kaderkader2947 ปีที่แล้ว

      Thank you

    • @jeremiahmwale9588
      @jeremiahmwale9588 9 หลายเดือนก่อน

      My generator Cummins 100kva ,on display is showing gen over voltage shadown

  • @user-jt6kc7yd1c
    @user-jt6kc7yd1c 2 หลายเดือนก่อน

    I have been inspired with this lesson. Very educative

  • @user-ko4jt9vb3t
    @user-ko4jt9vb3t ปีที่แล้ว +6

    hi sir. I can not understand how you can solve your customer problem of engine hunting? at the first part of this video you said your customer have problem with this engine . thanks for your video.

  • @pranavsrajeshiii-d2303
    @pranavsrajeshiii-d2303 หลายเดือนก่อน +1

    Could you please explain about stability and gain adjustment

  • @walusansadouglas5616
    @walusansadouglas5616 ปีที่แล้ว +1

    Much appreciation Eng. Muzamir,thank you for sharing this beneficial information

    • @DieselGeneratortraining
      @DieselGeneratortraining  ปีที่แล้ว +1

      Ur welcome

    • @dennisbriggs1088
      @dennisbriggs1088 6 หลายเดือนก่อน

      Engr Muzamir, please I need ur help.There is am American generator (3-phase/60hz). And I need to convert it to 50 Hz. Please, what should I do? Expecting your reply, thanks.

  • @robertasiimwe9337
    @robertasiimwe9337 หลายเดือนก่อน +1

    Hey Muzammil thanx for your videos they are really of great importance to us Engineer but i was requesting you to take me through the synchronizing proccess right from the beginning

  • @oscarfucanan4618
    @oscarfucanan4618 ปีที่แล้ว

    Thank you Sir for your nice explaination

  • @gacgovernorsamericacorp1383
    @gacgovernorsamericacorp1383 8 หลายเดือนก่อน +1

    This is a real GAC product! Yay!

  • @EffiongBassey-yv1kj
    @EffiongBassey-yv1kj ปีที่แล้ว +1

    Thanks this very educative

  • @adeebhassan5978
    @adeebhassan5978 หลายเดือนก่อน

    Thanks sir

  • @rafihussain
    @rafihussain ปีที่แล้ว +1

    Thanks for sharing. U r doing great job

  • @itsok2902
    @itsok2902 ปีที่แล้ว +1

    Thank you sir God Bless u

  • @BataDonason-ls4wp
    @BataDonason-ls4wp ปีที่แล้ว +1

    Thank you Boss you are the best

  • @samuelmiru2914
    @samuelmiru2914 หลายเดือนก่อน +1

    hi, good day my 3phase generator running well but 30- 40 minutes time it switched off , without load thanks.

  • @chamindagunarathna7774
    @chamindagunarathna7774 21 วันที่ผ่านมา +1

    Hi sir i have problem in 400kva genarator voltage no coming rpm also how can i solve this issue please help

  • @mohameddeik9556
    @mohameddeik9556 ปีที่แล้ว +1

    Thank you engineer

  • @sathishkrishnanasolar1339
    @sathishkrishnanasolar1339 7 หลายเดือนก่อน

    Thank you bro❤❤👍

  • @etoelectrotechinalofficer6286
    @etoelectrotechinalofficer6286 2 หลายเดือนก่อน

    bro, what was your hunting issue you found, when you testing you achieved from GOVERNOR actuator values of 8.9 vdc and 2 AC voltage from pick up sensor , hence where u finally reached the troubleshooting

  • @faridfarido6659
    @faridfarido6659 5 วันที่ผ่านมา

    What to do in case where generator trips with under speed while connecting load.

  • @mechanicdodz
    @mechanicdodz ปีที่แล้ว

    Thank you for sharing sir 'i have the trouble generator perkens 102kva''engine it has working''but no have the outpot ac supply'

  • @korushmw4896
    @korushmw4896 7 หลายเดือนก่อน

    Teach how to wire the governor of the Perkiniz 1106 motor to the DPSI 6021 controller board. Thank you.

  • @yourcomedychannel8027
    @yourcomedychannel8027 7 หลายเดือนก่อน

    How can I sync and parallel 4 generators where gen 1 and 2 is using a deepsea 8610 module and gen 3 and 4 using ComAp NTC controller.

  • @EffiongBassey-yv1kj
    @EffiongBassey-yv1kj ปีที่แล้ว

    Explain on configuring on dcec dongfeng Cummins 4bta3.9-g13 control module

  • @sahanas.r9360
    @sahanas.r9360 ปีที่แล้ว +1

    Sir, how to take stop signal externally by push button in kg934 62.5 kva genr,

  • @maxy437
    @maxy437 4 หลายเดือนก่อน

    You should disconnect component from governor and then check resistance.

  • @shonashona8332
    @shonashona8332 11 หลายเดือนก่อน +2

    One issue arha ha Generator under frequency shutdown
    And Generator under voltage shutdown
    But Rpm is ok and voltage also ok
    After I inactive frequency and voltage then we started Generator is working fine
    And we active generator under frequency and under voltage shutdown active then not cranking and locked out showing
    Can please help me know this issue

  • @marizbuay5265
    @marizbuay5265 4 หลายเดือนก่อน +1

    Sir cranking only theirs no suplly to push the actuator

  • @bobmulenga7786
    @bobmulenga7786 หลายเดือนก่อน +1

    Uli wauyo kabwalala

  • @Tanha_8817
    @Tanha_8817 2 หลายเดือนก่อน

    How to reduce or increase the running meter of the generator

  • @EdmondNgologwana-nj2qv
    @EdmondNgologwana-nj2qv ปีที่แล้ว +1

    Sir I need a d500 control panel kj power generator configuration

  • @Roatones
    @Roatones 9 หลายเดือนก่อน

    Sir you have a video about Cummins 100kva hard start? thanks..

  • @dennistejada2173
    @dennistejada2173 2 หลายเดือนก่อน +1

    I have a question.i start generator then will start.after 2 second will stop.what should i do.please helped me.

  • @user-jt6kc7yd1c
    @user-jt6kc7yd1c 2 หลายเดือนก่อน

    Pro muzzamil what could be the problem ever with the generator running idle and not to the rated speed 1500rpm speed. Hence Undervoltage

  • @njperez1310
    @njperez1310 ปีที่แล้ว +1

    Sir can you discuss CAT CDVR and MeccAlte DECS-150. In uour opinion, which is better between the two?

  • @gopeshbaichan3887
    @gopeshbaichan3887 ปีที่แล้ว +1

    Hi sir I do not know if u can help me in the parallel operation with generator where the pf on one alternator is fluctuate but the other is stable

  • @velusamypothiraj2300
    @velusamypothiraj2300 ปีที่แล้ว +1

    How to wiring in between dse controller and governor

  • @BataDonason-ls4wp
    @BataDonason-ls4wp ปีที่แล้ว +1

    I really wish I can get in contact with you sir

  • @B.S_eaditor_ff
    @B.S_eaditor_ff 7 หลายเดือนก่อน +1

    500 kva dg ke bare mein batao pl

  • @vikramnanavare8484
    @vikramnanavare8484 ปีที่แล้ว +1

    Sir please make a video of governer settings for synchronisation of 2 Nos DG set

  • @kaisirahmedvlog8428
    @kaisirahmedvlog8428 ปีที่แล้ว +1

    Coolant sensor fault, show display and engine shutdown,how can I do

  • @hermantoofa1868
    @hermantoofa1868 ปีที่แล้ว +1

    Hi bro
    I would like to change the coupling of the alternator, 400v triphase with neutral series star to 220v triphase parallel star triphase.what about to the deep sea controller ? Are there any setting to change? Change the wiring?

  • @mohd.f.shahnewaz860
    @mohd.f.shahnewaz860 5 หลายเดือนก่อน +1

    Assalamu Alaikum... Boss can u tell me what is MPU and what is the function of MPU? Thanks a lot.

  • @amg3434
    @amg3434 4 หลายเดือนก่อน

    What is the best brand? 4G

  • @dennisbriggs1088
    @dennisbriggs1088 6 หลายเดือนก่อน +1

    Muzamir,how can i convert an American generator (60 hz) to Uk generator (50 hz).

    • @DieselGeneratortraining
      @DieselGeneratortraining  6 หลายเดือนก่อน

      Contact me on : muzammiloger@hotmail.com with ur full details and generator details

  • @user-wd3hb9vb3d
    @user-wd3hb9vb3d 8 หลายเดือนก่อน

    Sir I can not know how to set configuration system please you guidelines me lot of thanks I live in Pakistan

  • @teklukifle9910
    @teklukifle9910 ปีที่แล้ว +1

    how i set the Generator availability of singe phase and three phase on Digital ATS
    L-N=220V
    L-L=380V
    NOT VISBLE during the Gentor running

  • @user-fo5sw3lv5c
    @user-fo5sw3lv5c ปีที่แล้ว +2

    هلا فيك ممكن كود شاشه EMS927 V3

  • @kelechiarinze7977
    @kelechiarinze7977 9 หลายเดือนก่อน

    Hi good morning, I don't understand where and what the actuator does

  • @farhanshoukat9901
    @farhanshoukat9901 ปีที่แล้ว +1

    Plz make this topic video in Urdu 30 to 40 min

  • @benzblogsVlogs
    @benzblogsVlogs ปีที่แล้ว +1

    In this speed controller connection i saw that this connection will run direct to speed 1800 no idle correct me if im wrong

  • @dennisbriggs1088
    @dennisbriggs1088 6 หลายเดือนก่อน +1

    How can I convert generac gas generator running on 60 Hz to 50 Hz?

  • @mohamedhanyf278
    @mohamedhanyf278 ปีที่แล้ว

    Ahsalaam Alaikum
    I am Mohamed Haneef from Maldives
    I have got an issue from the Generator Cummins KTA19G4
    It gets RPM variation between 1512 1506 1497 1488 etc when start it but the voltage is good
    So how can trouble it and how to Mach actuator with control card some one asked me we have to Mach both of no before fixed it
    I hope you can help me

    • @mohamedhanyf278
      @mohamedhanyf278 ปีที่แล้ว +1

      I need to know how to troubleshoot it and how to check MPU and Actuator

    • @kevin00861
      @kevin00861 ปีที่แล้ว

      For the magnetic pick up sensor,
      Run the engine,
      Check with multimeter the AC voltage at the speed control terminals of the MPU,
      You should get between 1 & 1.5 VAC

  • @verhillovalakay5393
    @verhillovalakay5393 3 หลายเดือนก่อน +1

    Sir nice job...❤❤❤but you very fast talking😂😂😂

  • @mugabogabriel-rp9se
    @mugabogabriel-rp9se 3 หลายเดือนก่อน

    Hi explain to how you can solve the problem when generator display power up in screen

  • @shaynegaudet6131
    @shaynegaudet6131 11 หลายเดือนก่อน

    Lf9000 oil

  • @irshadnaik3524
    @irshadnaik3524 ปีที่แล้ว +1

    My next q without mpu can start generator posibble

  • @Layaqathayatkhan
    @Layaqathayatkhan 8 หลายเดือนก่อน +1

    View 25k and like zero what happened

  • @user-py2zr9qs7l
    @user-py2zr9qs7l ปีที่แล้ว +2

    How to change hour reading?

    • @IjazAhmad-bo3wy
      @IjazAhmad-bo3wy 10 หลายเดือนก่อน

      Same issue is with me if u have solved then reply me

  • @usmanbhatti5804
    @usmanbhatti5804 ปีที่แล้ว +1

    Teacher tell me your Instagram
    There is no show on TH-cam about?

  • @irshadnaik3524
    @irshadnaik3524 ปีที่แล้ว +1

    Asslamualaikum sir how can chainge ovltage means 380 convert 220 xplain me

    • @DieselGeneratortraining
      @DieselGeneratortraining  ปีที่แล้ว +1

      Video available

    • @MEYMATO
      @MEYMATO หลายเดือนก่อน

      Sir,communication is lost, this is FI GENARATER WAS Cat,500kw,feeding 10vDc 410AcV but without control control panel

  • @muhamadasim8673
    @muhamadasim8673 11 หลายเดือนก่อน +1

    Bro if there is no governor, it can work right only we cannot control the control the fuel consumption

    • @DieselGeneratortraining
      @DieselGeneratortraining  11 หลายเดือนก่อน +1

      It depends on your Generator fuel system

    • @muhamadasim8673
      @muhamadasim8673 11 หลายเดือนก่อน

      Yr I am confuse with electronic engine and mechanical engineer can please share some info or data

  • @Umfuntv786
    @Umfuntv786 ปีที่แล้ว +1

    Assalamu alaikum Engineer
    SDMO GENERATOR VOLVO ENGINE CRANK THREE TIMES BUT UNABLE TO START PLEASE SUGGEST SOME SOLUTION

    • @DieselGeneratortraining
      @DieselGeneratortraining  ปีที่แล้ว +1

      What is Engine brand

    • @Umfuntv786
      @Umfuntv786 ปีที่แล้ว

      @@DieselGeneratortraining VOLVO

    • @Umfuntv786
      @Umfuntv786 ปีที่แล้ว

      @@DieselGeneratortraining VOLVO, model TAD1242GE

  • @alejandrocastor4274
    @alejandrocastor4274 3 หลายเดือนก่อน +1

    Check your mpu

    • @alejandrocastor4274
      @alejandrocastor4274 3 หลายเดือนก่อน

      If there's output

    • @alejandrocastor4274
      @alejandrocastor4274 3 หลายเดือนก่อน

      Check also voltage supply terminal has 12 or 24 volts

    • @alejandrocastor4274
      @alejandrocastor4274 3 หลายเดือนก่อน

      On terminal battery at speed control module

  • @user-ut8wt3pz6v
    @user-ut8wt3pz6v ปีที่แล้ว +1

    Please I want to have your contact please 🙏, my name is mustapha Ismail from Nigeria,I work at Topclass and we go for AJ power.
    Please I need your contact for personal assistant, for any problem about connection.
    May Allah help us and AJ power,I want you to be my boss Muzammil Ismail.
    Am Mustapha Ismail,I love your lectures.

  • @imranraza4331
    @imranraza4331 ปีที่แล้ว +1

    Can I get number sir

  • @teoscott1
    @teoscott1 2 หลายเดือนก่อน +2

    Sorry man but you just let me waste 12 minutes of my time. Just saying thrice that watching the video full length will help us but you never explained what those parts do. I would suggest you to do a proper video and explaining in brief how each component works then explain how you resolve the problem of Engine Hunting. You are just showing and telling us what you saw and just few explanation. Hope you understand my point.

  • @shuhayldaniels82
    @shuhayldaniels82 11 หลายเดือนก่อน

    Are you on WhatsApp?

  • @shaharulislam203
    @shaharulislam203 ปีที่แล้ว +1

    Thanks sir