Rectangular Footing Design | Numerical | Rectangular design problem | isolated rectangular footing

แชร์
ฝัง
  • เผยแพร่เมื่อ 28 ส.ค. 2024
  • This video explains the steps involved in designing of rectangular footing, detailed steps how to solve a problem on rectangular footing has been shown, also checks for one way shear and two way shear has been explained
    The link for the square footing : • Design of footing | Is...
    My Phone : amzn.to/311uFDW
    Amazon Basics 50-Inch Lightweight Tripod with Bag : amzn.to/3ayCdkG
    Laptop : amzn.to/3hi2yGp
    Limit State Design of Reinforced Concrete Design by B.C.Punmia : amzn.to/315UEu2
    Reinforced Concrete Design: IS:456-2000 Principles and Practice : amzn.to/315WLxY
    Illustrated Design of Reinforced Concrete Buildings : amzn.to/349rM62
    Design of Reinforced Concrete Structures : amzn.to/3142DYz
    #rectangularfooting #designoffooting #designofrectangularfooting

ความคิดเห็น • 144

  • @ojaswinikammili7489
    @ojaswinikammili7489 3 ปีที่แล้ว +2

    best channel in the TH-cam for structural engineers thank you sir

  • @magibooni875
    @magibooni875 4 ปีที่แล้ว +5

    Hi sir this is my first comment in YT ..great explanation I'm a recent subscriber..all video's r very clear ..in footing series kindly do a numerical on combined footing ..thank you

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  4 ปีที่แล้ว +1

      So nice of you, thanks for appreciating my work, support my channel with your friends, combined footing soon i will upload

  • @dannycbe949
    @dannycbe949 2 ปีที่แล้ว +2

    Good explanation.
    You could think of providing a reinforced pedestal to reduce the impact of shear.

  • @rohitsahu5845
    @rohitsahu5845 3 ปีที่แล้ว +1

    Everyone skip this in rectangular footing area of reinforcement should be calculated two times .i see your video just to verify that

  • @ankitdubey4949
    @ankitdubey4949 2 ปีที่แล้ว +4

    Nice work man
    Well done
    Clearly explained

  • @engineermohammedsoyebbadgu3714
    @engineermohammedsoyebbadgu3714 4 ปีที่แล้ว +1

    It is design only by Column Load or Reaction...
    How To We Design If there are also Some Bending force is come during Analysis...
    Like
    Pu 600 KN
    Mx 10 KNm
    My 25 KNm
    Thanks for your Explanation
    Superb 😊😊

  • @ShivKumar-qw8nd
    @ShivKumar-qw8nd 3 ปีที่แล้ว +1

    Nice way of teaching

  • @vasachisenjubean5944
    @vasachisenjubean5944 4 ปีที่แล้ว +3

    *THANKS A LOT SIR, I WAS WAITING EAGERLY FOR THIS VIDEO*

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  4 ปีที่แล้ว +3

      This was specially done for you which you had requested, keep supporting and loving like this and share with your friends

    • @vasachisenjubean5944
      @vasachisenjubean5944 4 ปีที่แล้ว +3

      @@structuralanalysisanddesign Thank you and stay safe

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  4 ปีที่แล้ว +2

      You too stay safe, next will be coming up with center line method to find out the quantities

    • @halalmeatshophk
      @halalmeatshophk 2 ปีที่แล้ว +3

      @@structuralanalysisanddesign Sir, at 24:50 you did a mistake. 1155 divide by 113 is 10.2 bars, but u answered 12.36 bars. why?
      if 10 bars is right, then it is under reinforced, right ? how come the calculation method is wrong ?

    • @brigadeshivu
      @brigadeshivu 5 หลายเดือนก่อน

      S correct

  • @bhaskarak4409
    @bhaskarak4409 ปีที่แล้ว +1

    Bro vertical load lo live load tesukunty same procedure y na bro

  • @nibhabhartee19
    @nibhabhartee19 2 ปีที่แล้ว +2

    sir for calculating Po we use column load only but here you used the total load.Why?

  • @PraveenKumar-vy4py
    @PraveenKumar-vy4py 4 ปีที่แล้ว +2

    Sir also add a video with design of singly and doubly reinforcement beam. Along with what is balanced reinforcement over reinforcement and under reinforcement section with the graf

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  4 ปีที่แล้ว +1

      Hello Praveen, Design of Singly reinforced beam already i have uploaded and also what is meant by balanced, under reinforced and over reinforced sections, please see the playlist in my channel "RCC", if you dont find it leave here one message il give the link.
      Design of Doubly reinforced beam i will do soon

  • @mauliktala7427
    @mauliktala7427 4 ปีที่แล้ว +6

    Sir please upload eccentric footing or corner footing design... it's also much importance now a days

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  4 ปีที่แล้ว

      Ya i will be coming up with those videos also, stay tuned for more civil engineering videos, check out my patreon profile

    • @PraveenKumar-vy4py
      @PraveenKumar-vy4py 4 ปีที่แล้ว +1

      @@structuralanalysisanddesign sir where is this patreon profile

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  4 ปีที่แล้ว

      its just like youtube

    • @sonukumar-bp4wb
      @sonukumar-bp4wb 4 ปีที่แล้ว

      Sir please make a video series on g+2 building structure .I am waiting for a building design . Thanks #abhijeet sir

  • @gowsiraj2076
    @gowsiraj2076 4 ปีที่แล้ว +2

    Good and neat explanation.... Thank you sir

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  4 ปีที่แล้ว +1

      So nice of you, keep watching

    • @gowsiraj2076
      @gowsiraj2076 4 ปีที่แล้ว +1

      @@structuralanalysisanddesign Many thanks to you for clear teaching and explanations about formula derivations... Please do more videos sir☺

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  4 ปีที่แล้ว +1

      Sure will try to come up with more videos soon

  • @civilexplorer7038
    @civilexplorer7038 3 ปีที่แล้ว +1

    Sir, U explained it very well😍. #Best

  • @sudarshannikam5243
    @sudarshannikam5243 3 ปีที่แล้ว +1

    Thanks sir for this explanation, Sir which bar should be at bottom or top (for footing jali) .Should short bars be at bottom side and long bars should be above short bars? Is it mandatory ? Position of long bar and short bar depend on depth d and d1. It always depending on sequence of calculation of Ast1 and Ast2. Is it mandatory that As1 should be calculated by max BM (M1u) and Ast2 should be calculated by low value of BM (M2u). Because sequence of calculation of Ast1 and Ast2 decides the position of upper side or lower side of bars due to depth d and d1 . Can we calculate As1 by M2u and As2 by M1u vice versa. In footing reinforcement schedule there is no provision of showing Max BM and sequence of Ast1 and Ast2 calculation then how to decide laying position of short bar or long bar (above or below for same jali as a long bar and short bar) ? Please explain sir.

  • @Hariprasad-io3rl
    @Hariprasad-io3rl 2 ปีที่แล้ว +1

    Sir I think u have to take ultimate load as 600kn itself
    Then we will get net pressure as 100kn/m2

  • @mirwaisoriakhel7419
    @mirwaisoriakhel7419 3 ปีที่แล้ว +1

    its wrong 1/2(L-a) its OK 1/2(L-1/2a) please chick this in Geometry.
    and your explanation very good.
    thanks.

  • @madhusudhan8583
    @madhusudhan8583 ปีที่แล้ว

    Sir,
    τv =Nominal shear stress 0.33 N/mm² is Greater than, τc=Design shear stress 0.328N/mm² . Hence it is safe in One way shear. This is been explained in your previous rectangular footing design video.

  • @Jaydev-oj2hx
    @Jaydev-oj2hx 8 หลายเดือนก่อน +1

    Sir,
    Is it mandatory to provide same diameter bars along both directions or can we use lesser diameter bars(say, 10mm bars) for Ast2?

  • @abdulzahiraliyi8675
    @abdulzahiraliyi8675 4 ปีที่แล้ว +1

    do we have to provide As1 in the shorter direction?
    do we have to always use the BOTTOM Reinforcement %(As1) while calculating for concrete shear in 1way shear check?

  • @mohamednaseer9167
    @mohamednaseer9167 4 ปีที่แล้ว +2

    For area of steel reinforcement Ast1 I think u made a mistake ... in the root of the formula it is Bd²... so it should be 400² which is equal to 160,000.. can u please clarify if I am wrong

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  4 ปีที่แล้ว +1

      Yes my dear student its BdSqaure and 400square, by mistake i have written only 400 but the answer is correct its done by taking 400sqaure

    • @johnnytun471
      @johnnytun471 ปีที่แล้ว +1

      He calculated with 400 square, he just forgot to put square sign in formular
      you can check his calculation is correct.

  • @Abc-wb2kk
    @Abc-wb2kk ปีที่แล้ว

    Sir i think you forget to put periphery value in last Two way shear Tv value ... formula is Load/periphery you only took load / Area of punching shear.

  • @chinmoy_ce_135
    @chinmoy_ce_135 3 หลายเดือนก่อน

    Sir if moment are given in the question on shorter side and longer side then how to calculate

  • @suraj__710
    @suraj__710 8 หลายเดือนก่อน

    sir in check for 1 way shear we concluded it as not safe , is it because Tv and Tc value are real close .If Tv = 0.35 and Tc=0.328 then it will be safe , isnt it sir , as there is a good difference here

  • @uttaranplotter5997
    @uttaranplotter5997 3 ปีที่แล้ว +2

    Sir, well presentation. Ast1 > 0.12% but Ast2

  • @hs.markandeyahonnalisiddap5534
    @hs.markandeyahonnalisiddap5534 ปีที่แล้ว

    Equal projectons beyond the coloumn are allowed for the design

  • @priyabrataghosh9309
    @priyabrataghosh9309 ปีที่แล้ว +1

    Sir,for net upward pressure of soil,in some books, they took the live load instead of adding 10% of it for calculating the value,here you add 10% with live load for calculating... now I'm confused sir... please reply

  • @prabhatrijal
    @prabhatrijal 3 ปีที่แล้ว

    Thank you sir.....
    Sir, it would be so great if you could make a video of design of eccentric loading footing too.

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  3 ปีที่แล้ว +1

      Your request Noted, keep watching and checkout channel membership feature

    • @prabhatrijal
      @prabhatrijal 3 ปีที่แล้ว

      @@structuralanalysisanddesign ok sir

  • @garrixergaming692
    @garrixergaming692 3 หลายเดือนก่อน

    Example from RCC BC Punmia 🤩🤩

  • @bheemaabhinav7941
    @bheemaabhinav7941 2 ปีที่แล้ว

    Pls explain about flat slabs design

  • @suraj__710
    @suraj__710 8 หลายเดือนก่อน

    sir do we have to show how the BM at XX equation comes or just write the equation only

  • @Mutant707
    @Mutant707 6 หลายเดือนก่อน

    cant u make a dedidated vedio on patterns for all types of structures

  • @arbeenbaba123
    @arbeenbaba123 3 ปีที่แล้ว

    Sir make a vedio on combined trapezoidal footing for 02 columns

  • @deenkibaatein4778
    @deenkibaatein4778 6 หลายเดือนก่อน

    Hi Bro can you please explain the shoe footing which is eccentric footing where column at edge side.

  • @narasimhamurthymr4612
    @narasimhamurthymr4612 4 ปีที่แล้ว +1

    sir, Ast-2 u have not followed clear spacing rule mentioned in table-15 of IS;456. for 415 steel clear spacing should not be more than 180mm. correct me if I'm wrong.

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  4 ปีที่แล้ว +1

      Check out page number 66 of IS 456-2000, clause 34.5.1, it says as per solid slabs we have to follow and table 15 is for beams, clause 26.3.3 in slabs it says 3 times effective depth or 300mm whichever is smaller.
      I hope i cleared you doubt, thanks for watching

    • @narasimhamurthymr4612
      @narasimhamurthymr4612 4 ปีที่แล้ว +1

      @@structuralanalysisanddesign Yes sir, cleared. Thank you. sir plz teach us edge column footing .... No YT channel did that.

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  4 ปีที่แล้ว +1

      Definitely i will try to work out that problem

    • @narasimhamurthymr4612
      @narasimhamurthymr4612 4 ปีที่แล้ว

      @@structuralanalysisanddesign sir, for Ast-2 , pt value is less than o.12%. in that case what to do? should provide minimum %?

    • @thecivilboyverma1430
      @thecivilboyverma1430 4 ปีที่แล้ว

      th-cam.com/video/LD03FfyTu1U/w-d-xo.html

  • @ministryofgirls_
    @ministryofgirls_ 2 ปีที่แล้ว

    Take only axial load while u r calculating soil pressure due to column load not total load sir

  • @raheelfaraz3040
    @raheelfaraz3040 3 ปีที่แล้ว

    Sir my quedtions
    1)is this a confirmed question from 5th unit
    2)i can do same method for scoring
    3)sir due to covid it caries 14 marks
    4) please reply
    4

  • @vijaybhasker2928
    @vijaybhasker2928 3 ปีที่แล้ว +1

    sir please make a video oncombined footing

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  3 ปีที่แล้ว

      Yes vijay working on it, will be coming up with detailed video

    • @vijaybhasker2928
      @vijaybhasker2928 3 ปีที่แล้ว

      @@structuralanalysisanddesign
      thank you so much for your concern sir. i respect you alot. because you made me to understand subject easily. and seriously no faculty had gave clear lecture than you

    • @vijaybhasker2928
      @vijaybhasker2928 3 ปีที่แล้ว

      @@structuralanalysisanddesign
      but sir, i have little bit of confusion while taking sections in rectangular footing design. please give me clearance about it

    • @vijaybhasker2928
      @vijaybhasker2928 3 ปีที่แล้ว

      @@structuralanalysisanddesign
      thank you sir, please take care

  • @khajaazammohiuddin5105
    @khajaazammohiuddin5105 หลายเดือนก่อน

    Now a days using fe 500 and 550
    How we design what is formulas

  • @vijaybhasker2928
    @vijaybhasker2928 3 ปีที่แล้ว

    sir, why dont you consider footing design biaxial moments i.e, "mx "and "my" ?

  • @kinlleygyamtshookh209
    @kinlleygyamtshookh209 2 ปีที่แล้ว

    sir ... if you could solve a problems on raft footing...

  • @jessicac6015
    @jessicac6015 3 ปีที่แล้ว +2

    Hello, could you explain where the M1u= 0.138FckBd^2 comes from?

    • @jessicac6015
      @jessicac6015 3 ปีที่แล้ว +1

      Its in 15.20

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  3 ปีที่แล้ว +2

      Hello Jessica, it is the modified formula of Mulim which is given on Page 96 of IS 456-2000 (G 1.1 (c) Formula) i have substituted (Xumax/d) value and got 0.138Fckbd^d and remember its valid only for Fe415. for Fe 250 and Fe 500 (Xumax/d) is different so you get different Mu value.
      I hope i cleared your doubt, keep watching and keep sharing

    • @jessicac6015
      @jessicac6015 3 ปีที่แล้ว +1

      @@structuralanalysisanddesign Thank you! Your videos are very informative :)

  • @vijaybhasker2928
    @vijaybhasker2928 2 ปีที่แล้ว

    sir kindly upload design of combined footing

  • @bholasontakke
    @bholasontakke 3 ปีที่แล้ว

    Please take problem on combined footing

  • @UjjwalKumar-
    @UjjwalKumar- 3 ปีที่แล้ว

    Sir , I have Doubt in 7:45 W is equal to Load Given sir , But Why you took 660 , we should take 600 na Sir .
    Pls Tell me as soon as possible

  • @vjyvncnt
    @vjyvncnt 4 ปีที่แล้ว

    Foundation size if we make same size we get less rft moment will reduce
    Make 4 side same size for construction

  • @arbaazmirza5084
    @arbaazmirza5084 ปีที่แล้ว

    Please mention which codes used ???? In all ur videos...

  • @civilstruct4053
    @civilstruct4053 4 ปีที่แล้ว

    sir how u are taking b/L ratio as 40/60 ,is it practicle ????

  • @vkchowdary7924
    @vkchowdary7924 3 ปีที่แล้ว

    In Area Calculations why take B/L = 40/60
    This ratio will be taken from column dimensions ?

  • @Civilzone975
    @Civilzone975 2 ปีที่แล้ว

    Sir I have problem in SFD and BMD of frame structure ☹️☹️☹️☹️

  • @rohitsahu5845
    @rohitsahu5845 3 ปีที่แล้ว

    Best bro

  • @rithikavidhu5700
    @rithikavidhu5700 8 หลายเดือนก่อน

    hi sir for ast2 did u take d1^2?

  • @amansah9354
    @amansah9354 3 ปีที่แล้ว

    sir can u pls upload the eccentric footing design ...

  • @suraj__710
    @suraj__710 8 หลายเดือนก่อน

    sir whats the name to be written for Vx andVux

  • @rohitarya7512
    @rohitarya7512 2 ปีที่แล้ว

    Sir, upward pressure mai to =load on column to total area lai tai hai na
    Sir aap total load to total area lai liyai hai,
    Sir, if i am wrong then help me sir

  • @kwalicks
    @kwalicks 3 ปีที่แล้ว

    but as per is code depth is governed my shear only, for safe design of footing.... so how is it possible to adopt depth by calculating moment

    • @brigadeshivu
      @brigadeshivu 5 หลายเดือนก่อน

      Then how to calculate Ast without moment we have to assume Ast and then proceed for depth by shear

  • @katilnikki7104
    @katilnikki7104 4 ปีที่แล้ว

    Cant we calculate moment with cantilever formula?

  • @bagguviswanadh8036
    @bagguviswanadh8036 4 ปีที่แล้ว +1

    And from which code book u took ast formula please let me know

  • @bhanusairamoju9000
    @bhanusairamoju9000 2 ปีที่แล้ว

    It should be (T suffix v) < (T suffix c)
    In one way shear

  • @mariyamir2000
    @mariyamir2000 3 ปีที่แล้ว

    At 40:06 how do we calculate the value of Fu? Plz explain

  • @bajisaidavalishaik5670
    @bajisaidavalishaik5670 2 ปีที่แล้ว

    What if they given bi axial load in question?

  • @aayushrjl
    @aayushrjl 4 ปีที่แล้ว +1

    Sir next time please use X-X section in X axis and Y-Y section in Y axis , its really confusing

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  4 ปีที่แล้ว

      It depends upon you aayushrjl but still i will consider your suggestion, thanks for watching

  • @sangavaimkulanthaivelu8217
    @sangavaimkulanthaivelu8217 2 ปีที่แล้ว

    If ast1

  • @kartikshettar2050
    @kartikshettar2050 3 ปีที่แล้ว

    Sir staircase problems upload

  • @amitsaha2537
    @amitsaha2537 4 ปีที่แล้ว +1

    for net upward pressure , isnt it we should use factored load?? like 1.5*600

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  4 ปีที่แล้ว

      Hello amit, i have not incorporated factored load while calculating upward pressure but if you watch carefully complete video i have factored moment by mutiplying 1.5, its usual practice to use safety factor for moment instead of load

  • @vikasreddy2562
    @vikasreddy2562 3 ปีที่แล้ว

    Sir, why u considered b/l = 40/60

    • @K1M01
      @K1M01 2 ปีที่แล้ว

      Column

    • @K1M01
      @K1M01 2 ปีที่แล้ว

      400/600

  • @imazuddinzoha4260
    @imazuddinzoha4260 4 ปีที่แล้ว +1

    fck means=?
    Is it ultimate compressive strees???
    sir plz reply

  • @gixerriders1993
    @gixerriders1993 4 ปีที่แล้ว +1

    Are you same from Build it home channel ? Am I right ?

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  4 ปีที่แล้ว +1

      No Madhvendra, This is my first channel

    • @gixerriders1993
      @gixerriders1993 4 ปีที่แล้ว +1

      @@structuralanalysisanddesign don't mind pls thank you your all solutions are so unique & useful for exams ......

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  4 ปีที่แล้ว

      I am very happy that my videos are useful for you, this motivates me to come up with more videos, keep supporting and sharing these lectures to your civil engineering friends

  • @rajivprajapati7458
    @rajivprajapati7458 4 ปีที่แล้ว

    Why you don't check minimum reinforcement in case of ast2.

  • @georgen9755
    @georgen9755 10 หลายเดือนก่อน +1

    hand writing not in compliance

  • @panchalchintan9689
    @panchalchintan9689 3 ปีที่แล้ว

    Can anyone tell me about B/L ratio where this came from🤔

  • @UjjwalKumar-
    @UjjwalKumar- 3 ปีที่แล้ว

    Pu = P/A ( 600/6) = 100Kn/m²

  • @arifshaik711
    @arifshaik711 4 ปีที่แล้ว +1

    why you are not using this formula for Ast calculation Mu=0.87 x fy x Ast d {1-(Ast*fy/(bd*fck))}

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  4 ปีที่แล้ว

      I dont use that formula because it becomes tedious to follow that formula, the modified version of Ast formula which i use is very easy to use and apply, please refer Limit State Design of Reinforced Concrete by B.C.Punmia for that theory how the formula is modified, i recommend to use modified version for simplicity, however both formula gives same Ast.

    • @arifshaik711
      @arifshaik711 4 ปีที่แล้ว

      Tq so much sir for giving clarity, I did one footing design with reference of your video that is sq footing and rectangle column I'll send it Plz check sir.....

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  4 ปีที่แล้ว

      sure

  • @bagguviswanadh8036
    @bagguviswanadh8036 4 ปีที่แล้ว

    Sir ast1 u in place of dsqure u give n d means instead of 400*400 u given 400

  • @bagguviswanadh8036
    @bagguviswanadh8036 4 ปีที่แล้ว +1

    I need circler footing problem

  • @monishabalu622
    @monishabalu622 3 ปีที่แล้ว

    Sir, how to calculate the bending moment in square footing for rectangular column ?

    • @praveenmotovlogger98
      @praveenmotovlogger98 3 ปีที่แล้ว +1

      Consider critical section length i.e (L-a/2) and BM for cantilever is WL^2/2...
      Finaly u wil get Wu(L-a)^2/8

    • @everthinghere3750
      @everthinghere3750 2 ปีที่แล้ว

      @@praveenmotovlogger98 hi Darla

    • @vjyvncnt
      @vjyvncnt ปีที่แล้ว

      B.m =po.B*L/8(B-b)^2
      But my doubt is how two way shear check for a rectanglurar column squre footing

  • @kids-nv7et
    @kids-nv7et 4 หลายเดือนก่อน

    design safe eddida mad ri sir 😢😢

  • @tarun8741
    @tarun8741 2 ปีที่แล้ว

    Ast 2 is wrong answer sir

  • @dheerajkhanal7251
    @dheerajkhanal7251 3 ปีที่แล้ว

    circular footing bolo sir. voh kohi thik sey nahi bolrey. plze explain that.

  • @tejavajrala7190
    @tejavajrala7190 3 ปีที่แล้ว +1

    Wrong solution..B value is taken wrong. At Vx it is raken as 2000 and at Tv it is taken as 3000..ive wasted my time looking at this video. Observe from 29th minute. DISAPPOINTED.

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  3 ปีที่แล้ว +3

      Solution is not wrong, at 33:22 i have corrected as 2000, while writing i made mistake but value calculated is correct

  • @amritkumarbehera7748
    @amritkumarbehera7748 9 หลายเดือนก่อน

    How d= 0.4???