Design of Footing| Isolated Square Footing| Civil Engineering

แชร์
ฝัง
  • เผยแพร่เมื่อ 29 ต.ค. 2024

ความคิดเห็น • 130

  • @mdsajid-mq2cm
    @mdsajid-mq2cm 4 ปีที่แล้ว +12

    Mam, net upward pressure calculated value as per calculation is 293 kpa that little value varies for moment and one Way shear check and Two Share check , Nice explanation thank you.

  • @pulakpal2915
    @pulakpal2915 4 ปีที่แล้ว +19

    For calculating net upword pressure you put load of footing 1760 kn but the calculated value is based on 1600 kn

    • @learngrandeur304
      @learngrandeur304 4 ปีที่แล้ว +1

      Manda, self weight of footing is assumed 10 percent. Watch full

    • @Structure0156
      @Structure0156 3 ปีที่แล้ว +2

      @@learngrandeur304 please read the book first before watching this video.... Unfactored load=1600kN..... 10% increase load durring calcuation the area of footing not there . But durring calcuation the net upward pressure have not to take 10% increase value.

    • @surykantchaudhary5138
      @surykantchaudhary5138 ปีที่แล้ว +1

      ​@@Structure0156yeah u right 👍 load must be 1600 KN instead of 1700 KN.

    • @ashokankp4321
      @ashokankp4321 11 หลายเดือนก่อน

      Yes it has to be corrected

  • @deekshihomes
    @deekshihomes 5 ปีที่แล้ว +4

    In critical section what value u multiplied with 266.67

    • @halalmeatshophk
      @halalmeatshophk 3 ปีที่แล้ว

      i guess the answer is 3. but why ? need to clarify. lots of things is missing explanation.

  • @rajanv.m.8136
    @rajanv.m.8136 4 ปีที่แล้ว +2

    While arriving size of footing, it is a concept to assume self weight of footing as 10% of column load. As the weight of footing is nearly equal to weight of earth excavated to the volume of footing, you can ommit the self weight on economical point of view. If you want to add self weight of footing, you may consider little less. While working out it is found that the difference in weight of column and footing embedded in soil and excavated earth is only 3 to 4% of column load considering weight of soil is already included in net sbc of soil. Hence You can take 5% as self weight of footing. This is resonable for isolated footing.

  • @KISHANKUMAR-xf4ki
    @KISHANKUMAR-xf4ki 5 ปีที่แล้ว +10

    Mam ,not including footing load in upward pressure

  • @halalmeatshophk
    @halalmeatshophk 3 ปีที่แล้ว +3

    at 9:35, please confirm if the P-t should be 0.1399 instead of 0.136? thanks

  • @aryansing07
    @aryansing07 ปีที่แล้ว

    ❤❤❤❤omgg thanku you so much dear you make it easy

  • @RaviKumar-ku6yf
    @RaviKumar-ku6yf 3 ปีที่แล้ว +4

    Load on critical section will be 266.67x1.25 =333.33 kN/m and bending moment at face of column will be 266.67x1.25x1.25/2=208.33kN.m/m, plz correct me if I m wrong

    • @RaviKumar-ku6yf
      @RaviKumar-ku6yf 3 ปีที่แล้ว

      Oh ok, I was calculating per m along the width of footing....

  • @BHADRATY
    @BHADRATY 3 ปีที่แล้ว +2

    She was making laugh while explaining with her voice 😂😂😂. Nice explain 👍👍👍

  • @thomasokusi2696
    @thomasokusi2696 2 ปีที่แล้ว

    I love your clear voice well understood

  • @fistonndongalo139
    @fistonndongalo139 3 ปีที่แล้ว

    you are simply THE BEST , much appreciate it !!!!!!!!!!!!!!!!!1

  • @rameezkhan9352
    @rameezkhan9352 3 ปีที่แล้ว +2

    1 word for u..wonderful

  • @bhaskarraodee1743
    @bhaskarraodee1743 4 ปีที่แล้ว +2

    Excellent Teaching ..Thank you Madam

  • @prashantbilthare8742
    @prashantbilthare8742 5 ปีที่แล้ว +4

    1.5 se column load ko into krenge na when we calculating upward pressure, aapne total load se kiya h?

  • @henryjojodadzie6420
    @henryjojodadzie6420 3 ปีที่แล้ว +2

    in the sizing of the footing, i noticed you used the serviceability limit state and the ultimate limit state for the net upward pressure. In case you have the factored reaction for axial, should one use the factored axial load or unfactor it before applying

  • @narasimharaojakkampudi8405
    @narasimharaojakkampudi8405 2 ปีที่แล้ว

    Very clear explaining

  • @rahmanrahmani2896
    @rahmanrahmani2896 4 ปีที่แล้ว +1

    You have provided bottom reinforcement in both directions which are O.K, but you need to provide minimum top reinforcement in both direction as well. The four corners of the footing are in tension due to column loading therefore, you need to provide extra reinforcement up to 1m from each corner in both directions. You have not provided close up bars as well as face reinforcements which may be required and based on the code that you are using.
    Rahman Rahmani

    • @engmaalin1103
      @engmaalin1103 4 ปีที่แล้ว

      What Should be the minimum top reinforcement ? Please.

  • @puneithjain6815
    @puneithjain6815 2 ปีที่แล้ว +1

    Since the depth of the footing is around 730 mm which is nearly 2'6" depth , should we have to provide both top & bottom reinforcement in footings?

  • @Gaurang_Khatri
    @Gaurang_Khatri ปีที่แล้ว

    1:34 Mam as u did , for load on footing forumla is 1.1 × working load .
    But when in question ultimate load is given do we divide it by 1.5 ?
    And then 1.1× working load ?
    Pls guide

  • @RakeshKumar-ef4ko
    @RakeshKumar-ef4ko 2 ปีที่แล้ว

    easy to understand thank you soo much mam

  • @ashokankp4321
    @ashokankp4321 11 หลายเดือนก่อน

    Excellent work

  • @balucomedywonders2948
    @balucomedywonders2948 3 ปีที่แล้ว

    Why we should take higher values?

  • @sumitmondal548
    @sumitmondal548 2 ปีที่แล้ว

    madam, for the reinforcement steel area why did not use the formula shown in IS 456-2000? instead SP 16?

  • @jaiharris9824
    @jaiharris9824 5 ปีที่แล้ว +2

    Sister your explanation is very clear thanks for it but I have another small request if you can please make video for high water table foundation also please

  • @balucomedywonders2948
    @balucomedywonders2948 3 ปีที่แล้ว +1

    Why can't we take approximately d= 300mm

    • @halalmeatshophk
      @halalmeatshophk 3 ปีที่แล้ว

      because it will fail under shear stress.

  • @bari198810
    @bari198810 2 ปีที่แล้ว +1

    Would like to Thank cwill, well explained.
    Thanks once again.
    The videos are really helpful and at hand. 👍👍

  • @tejavajrala7190
    @tejavajrala7190 3 ปีที่แล้ว

    OMG she is damn good at explaining.. ❤❤

  • @rahmanrahmani2896
    @rahmanrahmani2896 4 ปีที่แล้ว +2

    Excellent work. You need to provide min reinforcements at the top in two directions to prevent thermal cracking. Could you please calculate how much reinforcement is required to over come the thermal cracking effects. You also need to provide close up bars on four faces (U-Bars). Since the total depth is 730mm I think you need to provide face reinforcement as well (simply you design a steel cage to put it into the ground and fill it with concrete). Thank you

  • @tadakamallapavankumar3989
    @tadakamallapavankumar3989 2 ปีที่แล้ว

    Nyc

  • @barakayekonia7468
    @barakayekonia7468 ปีที่แล้ว

    Congratulations

  • @vijaybhasker2928
    @vijaybhasker2928 4 ปีที่แล้ว +3

    ok madam , i got it, thank you. but actual value of upward pressure is 293.33kn/m^2, kindly please check, thank you

    • @Structure0156
      @Structure0156 3 ปีที่แล้ว

      Yes u r right bro... Bt madam has taken some wrong values,.. correct value is 1.5×1600/9= 266.67 kN/m^2

    • @Structure0156
      @Structure0156 3 ปีที่แล้ว

      1.5×unfactored load/area of footing.... This is a true sum.
      Unfactored load=1600KN...... Not 1760kN

  • @jawaharbharani1866
    @jawaharbharani1866 2 ปีที่แล้ว +2

    Mam,how can upward soil pressure greater than SBC?

    • @amaridenise2539
      @amaridenise2539 2 ปีที่แล้ว

      I agrer with you @jawahar bharani in this case you need to increase the footing size, upward soil pressure must not be greater than the SBC = 200 KN/M^2.
      It must be Corrected.

  • @ashwinpatil4034
    @ashwinpatil4034 4 ปีที่แล้ว +2

    maam how did you calculated ast provided & area of highlighted section

    • @achhuanapl1789
      @achhuanapl1789 4 ปีที่แล้ว

      yeah !! ast provided is not mentioned . how ???

  • @Ayush_N_M
    @Ayush_N_M ปีที่แล้ว

    Thank u mam ......

  • @thesanthu00
    @thesanthu00 ปีที่แล้ว

    3.56
    here.
    Net upward pressure value is 293.33 KN.
    U calculated value is 266.67
    How is it mam

  • @shafeekh6223
    @shafeekh6223 2 ปีที่แล้ว

    Mam, the great 😍😍

  • @fistonndongalo139
    @fistonndongalo139 3 ปีที่แล้ว

    please can you help me lost here , i wanted to make sure about the depth of the foundation and concrete thickness ...so the 650 is for the depth so what about the thickness of the concrete ?.....................PLEASE HELP

  • @structuraldesign2288
    @structuraldesign2288 4 ปีที่แล้ว

    Great video

  • @nightking3008
    @nightking3008 3 ปีที่แล้ว

    for calculating net upward soil pressure..factor load Pu=1600*1.5=2400kn

  • @mohammadafaan8241
    @mohammadafaan8241 ปีที่แล้ว

    Kormaye khup khup

  • @jayshah8711
    @jayshah8711 4 ปีที่แล้ว

    Good explanation mam.

  • @adarshalagur9148
    @adarshalagur9148 6 หลายเดือนก่อน

    Why are you multiplying 2.5 times the depth of foooting which is 225mm, after multiplication it will be 650mm so 650mm it means 2.5 ft depth. So cost wise it will become high I think 300mm depth is enough to consider here maam👍.

  • @er.sayanpal
    @er.sayanpal 3 ปีที่แล้ว +1

    how to calculate ast provided 2827.35

  • @suneejamyla7304
    @suneejamyla7304 2 ปีที่แล้ว

    Thank u mam

  • @VIJAYKUMAR-pj6hf
    @VIJAYKUMAR-pj6hf 2 ปีที่แล้ว

    Please tell us how did you get alpha St value for each providing mm dia bars

  • @b.nawazligade3582
    @b.nawazligade3582 4 ปีที่แล้ว

    Mam U HAVE ONLY CALCULATED Spacing between steel bars BUT DIDN'T MENTIONED it in the ROUND NUMBER & IN THE DRAWING Also How much Exactly the Spacing b/w the Reinforcement ,U didn't show. Please answer it. Thank U.

  • @selvakumaran4685
    @selvakumaran4685 3 ปีที่แล้ว

    nice

  • @warmthofblaze8788
    @warmthofblaze8788 4 ปีที่แล้ว

    Superb💖💖💖

  • @devarajathinarapu7701
    @devarajathinarapu7701 5 ปีที่แล้ว

    Mam iam devaraj ur voice like my teacher santoshi very sweet keep rocking

  • @bestrong8724
    @bestrong8724 5 ปีที่แล้ว

    Madam when you did win d load analysis as per is 875-3 you did not explain about the exposure coefficient I.e windward coefficient and leeward coefficient.
    Please explain those.

  • @amitmishra2909
    @amitmishra2909 5 ปีที่แล้ว

    Thank you very much mam, you explained the design beautifully.....

  • @khan01_
    @khan01_ 11 หลายเดือนก่อน

    What to do if two way shear check gets failed

  • @sukhram_rtw_143
    @sukhram_rtw_143 4 ปีที่แล้ว

    Nice... mam.

  • @thamimahmed6108
    @thamimahmed6108 3 ปีที่แล้ว

    My college ma'am use to teach this but I didn't care that time...now regretting after for it 😔

  • @rajanv.m.8136
    @rajanv.m.8136 4 ปีที่แล้ว

    I have one doubt in calculating net upward pressure. The pressure ia acting upward while the self weight of footing is acting downward. hence you have not to consider self weight of footing for net upward soil pressure .

  • @s.thamilmaran3880
    @s.thamilmaran3880 4 ปีที่แล้ว

    This is o.k .mam please explain rectangular footing.

  • @zaheerdardar8340
    @zaheerdardar8340 4 ปีที่แล้ว +1

    Teacher great , you have convey v excellent way of teaching, i watch here in kuwait its so nice , R U teacher in Life , great you from ? Ladies are much intelligent

  • @Mizabmehndiartist
    @Mizabmehndiartist 4 ปีที่แล้ว

    Good explaaination

  • @luckysharma6849
    @luckysharma6849 2 ปีที่แล้ว

    Where is the formulas in code book can u say the page no.

  • @biharugeacinfo6372
    @biharugeacinfo6372 7 หลายเดือนก่อน

    Load on critical section how to calculate???????

  • @naveenreddyemani8731
    @naveenreddyemani8731 4 ปีที่แล้ว +1

    As per is 456-2000 spacing =(B×ast)/AST

  • @rknprojects3977
    @rknprojects3977 3 ปีที่แล้ว

    Mam don't we have to add the surcharge load due to plinth height on footing while calculating the area of footing.

  • @shambubhagat5388
    @shambubhagat5388 2 ปีที่แล้ว

    Please tell how you calculated ast

  • @riteshbadhani2625
    @riteshbadhani2625 4 ปีที่แล้ว

    thank you maam

  • @sknooruddin1442
    @sknooruddin1442 4 ปีที่แล้ว

    Mam, if nominal shear stress is greater than permissible shear stress then what should be do ??? Pls reply asap

    • @zaidalsudani7588
      @zaidalsudani7588 4 ปีที่แล้ว

      increase value of depth footing until check shear

  • @umashankarjagadish7755
    @umashankarjagadish7755 4 ปีที่แล้ว +1

    when designing the footing ,As a structural engineer its his job to design the depth n size of the footing based on Architectural plan . Your video is somewhat like teaching question & answer type
    what is this ???

    • @NehaSingh-me9bb
      @NehaSingh-me9bb 4 ปีที่แล้ว +1

      I guess she is making videos for student centric audience which I find excellent as I am also a student.

    • @umashankarjagadish7755
      @umashankarjagadish7755 4 ปีที่แล้ว +1

      @@NehaSingh-me9bb practical understanding is important ,not theoretical....you can't implement this while designing

    • @NehaSingh-me9bb
      @NehaSingh-me9bb 4 ปีที่แล้ว +1

      @@umashankarjagadish7755 i agree with you. But only this type questions are asked in semester exams.

    • @umashankarjagadish7755
      @umashankarjagadish7755 4 ปีที่แล้ว +1

      @@NehaSingh-me9bb if you are practical ,you would have not asked this question
      Be practical

    • @NehaSingh-me9bb
      @NehaSingh-me9bb 4 ปีที่แล้ว

      @@umashankarjagadish7755 the type of practical structural knowledge you are looking for won't come for free on TH-cam. Join some paid course. This channel is for students and faculties who want to learn more. Be mature and sensible.

  • @veenayadav-wc6iq
    @veenayadav-wc6iq ปีที่แล้ว

    Mam how u get alpha x value

  • @HimadriDeka-qk1qt
    @HimadriDeka-qk1qt 11 หลายเดือนก่อน

    Net upward pressure value= 293.33 kN/m2

  • @srikalyan8844
    @srikalyan8844 3 ปีที่แล้ว

    formulae for Pt is in IS code book 456:2000 if there please mention the clause or page number sir

  • @rkkaruna221
    @rkkaruna221 5 ปีที่แล้ว

    Thank you so much

  • @Harish_infra
    @Harish_infra 4 ปีที่แล้ว +1

    NICE EXPLANATION MADAM #HARISHKUMARR

  • @anilkota8589
    @anilkota8589 5 ปีที่แล้ว +2

    bf value how much

  • @kp81
    @kp81 2 ปีที่แล้ว

    Please give Rectanguar footing also video

  • @saketimanitilak7332
    @saketimanitilak7332 ปีที่แล้ว

    net upward pressure calculated is wrong u written 266.67 but it is 293.33

  • @engmaalin1103
    @engmaalin1103 4 ปีที่แล้ว +1

    Mam, Please upload the design of Uni-axial and Bi-axial footings kindly . I have confused a lot.

  • @vijaybhasker2928
    @vijaybhasker2928 4 ปีที่แล้ว

    madam pleaSe let me know how did you got 800 kn/m. please explain

  • @shreeyavyas379
    @shreeyavyas379 4 ปีที่แล้ว +1

    My net upward pressure is 293.33 KN/M^2

    • @devashishsandhu7549
      @devashishsandhu7549 3 ปีที่แล้ว +2

      Bcz she had a mistake it's 1.5×load on column by area of footing

  • @anishdas7376
    @anishdas7376 4 ปีที่แล้ว +3

    Multiple error in this solution
    In udl wl^2/2 does not exist

  • @trailers6730
    @trailers6730 3 ปีที่แล้ว

    Net upward pressure should be 293kn m2 but it is 266 written

  • @moinriyazshaikh5638
    @moinriyazshaikh5638 5 ปีที่แล้ว +1

    Plz design edge & corner footings along property line

  • @rajanv.m.8136
    @rajanv.m.8136 4 ปีที่แล้ว

    Kindly add the depth of foundation using Rankines formula.

  • @undhinesh
    @undhinesh 10 หลายเดือนก่อน

    7:39, from where we get Mu=0.138*fck*b*d^2 (in code means can share cl or pg no:) thanks

  • @juthinalex3106
    @juthinalex3106 4 ปีที่แล้ว

    Can u please explain moment redistribution

  • @sabujkumardolui3251
    @sabujkumardolui3251 11 หลายเดือนก่อน

    Explain find out the load on critical section bf

  • @amitsarpanch
    @amitsarpanch 4 ปีที่แล้ว

    which clause is Mu= 0.38fck bd^2.. can any one tell me please ?

    • @vasachisenjubean5944
      @vasachisenjubean5944 4 ปีที่แล้ว

      Page 96 Mu limit

    • @amitsarpanch
      @amitsarpanch 4 ปีที่แล้ว +1

      @@vasachisenjubean5944 Thank you, I figured it out before but thanks for replying.

    • @tushar.0275
      @tushar.0275 4 ปีที่แล้ว

      @@vasachisenjubean5944 dada ki korchis

    • @vasachisenjubean5944
      @vasachisenjubean5944 4 ปีที่แล้ว

      @@tushar.0275 😋😛

  • @udaykiran9438
    @udaykiran9438 5 ปีที่แล้ว

    Madam, please do column analysis and design of uni axial and bi axial bending. Thank you

  • @Vikas-kf5ys
    @Vikas-kf5ys 4 ปีที่แล้ว

    thanks please upload related numerical for more understand

  • @sunilnishad2
    @sunilnishad2 3 ปีที่แล้ว +1

    You are not clearly understood the people......... Totally confused.
    If anyone then hit like......for support

  • @surykantchaudhary5138
    @surykantchaudhary5138 ปีที่แล้ว

    Tau V should be less than K times of tau C

  • @vighneshbhadekar20
    @vighneshbhadekar20 5 ปีที่แล้ว

    Plz upload rectangular footing

  • @mukulgarg9857
    @mukulgarg9857 4 ปีที่แล้ว

    How is that Pt formula came from in reinforcement step?

    • @cwillstructures
      @cwillstructures  4 ปีที่แล้ว

      th-cam.com/video/ZbyadDc1aTA/w-d-xo.html
      Sir you can watch this video and you can get idea about Pt formula

    • @amaridenise2539
      @amaridenise2539 2 ปีที่แล้ว

      SBC = 200 KN/M^2 < 293.33 which is the computed upward soil pressure so you need to increase the size if your footing..correct me if im wrong

  • @warzone7978
    @warzone7978 4 ปีที่แล้ว +1

    One major mistake u have done in the sum in the reinforcement

  • @structureboy7639
    @structureboy7639 4 ปีที่แล้ว

    U too not designed completely..,,🥺

  • @just__alem1497
    @just__alem1497 3 ปีที่แล้ว

    am i the only one who got the calculation of nrt upward pressure as 293.33 instead of 266.67?

  • @experiencetheinfinity
    @experiencetheinfinity 2 ปีที่แล้ว

    Not impressed 😕 😒 😐 😑 pls try to explain it more clearly and accurately

  • @Mustafa-hw4kb
    @Mustafa-hw4kb 2 ปีที่แล้ว

    maam concept clear nhi hai aap ka

  • @alakeshdutta4139
    @alakeshdutta4139 2 ปีที่แล้ว

    nuubb

  • @veenayadav-wc6iq
    @veenayadav-wc6iq ปีที่แล้ว

    Mam how u get alpha x value