Best UFO LED high bay lights in 2024 [warehouse]

แชร์
ฝัง
  • เผยแพร่เมื่อ 13 ก.ย. 2024

ความคิดเห็น • 18

  • @umitgoren9430
    @umitgoren9430 ปีที่แล้ว

    I have a 70×144 shop with 18 ft ceiling. How many of these would I need. Guessing 3 rows of 9? Also have a tool room that's 16×40, 12 ft ceiling. And also a 16×40 with 12 ft ceiling. The tool room needs to be well lite, where the storage room not so much. Also need outside lights on each side of a 58 ft door and a 30 ft door.

    • @CoydonLighting
      @CoydonLighting  ปีที่แล้ว

      For the 70x144 we recommend you to use 30pcs 200W UFO LED high bay lights for your building, you can place them in five rows of six fixtures. For the 16x40 we recommend you to use 5pcs 100W UFO LED high bay lights for your building, you can place them in one row of five fixtures.

  • @bulentuncuoglu-vt2ot
    @bulentuncuoglu-vt2ot ปีที่แล้ว

    I am is 8 of your 150 W lights in my 48x48x14 shop and have loved them... I am now working on remolding my 24x36x10' shop into a game room for the kids and wondering what your recommend for coverage? I'd like bright light when playing games, and then dim it down for movies. thanks!

    • @CoydonLighting
      @CoydonLighting  ปีที่แล้ว

      We recommend you to use 6pcs 100W UFO LED high bay lights for your building, you can place them in 2 rows of 3 fixtures.

  • @fatmacaki8213
    @fatmacaki8213 ปีที่แล้ว

    We are building a garage that is 44' W x 72'L x 16' H walls to house our RV which will sit in the center of the building. The interior walls and ceiling will be finished with white metal liner panel. What lighting and spacing would you recommend given we do not want lighting directly above the RV as the RV will block the light? The RV is roughly 16' wide with the slides out. We want the interior to have plenty of light without dark spots.

    • @CoydonLighting
      @CoydonLighting  ปีที่แล้ว

      We recommend you to use 15pcs 150W UFO LED high bay lights for your building, you can place them in 3 rows of 5 fixtures. You can send email to sales@coydon-lighting.com a design of your building and we will provide a detailed layout.

  • @Mustafakayik7456
    @Mustafakayik7456 ปีที่แล้ว

    I have a 32X40 shop with coffered trusses, so the ceiling is 12' high by 10' wide on each side and the center of the ceiling is 13-1/2' high x 12' wide. I was thinking of running three lights evenly spaced on each side and three evenly spaced in the center. What is your recommendation as far as count, style nd output of lights? I like a very well lit space.

    • @CoydonLighting
      @CoydonLighting  ปีที่แล้ว

      We recommend you to use 8pcs 100W UFO LED high bay lights in a 2x4 pattern (evenly spaced fixtures) for your building.

  • @abdullahbilici4312
    @abdullahbilici4312 ปีที่แล้ว

    Building 50 x 50 20 ft ceiling How many 250 watt lights do I need N what is the spacing u recomend The building will be a csr fab shop n restirations

    • @CoydonLighting
      @CoydonLighting  ปีที่แล้ว

      We recommend you to use 9pcs 200W UFO LED high bay lights for your building, you can place them in a three by three grid.

  • @emre9039
    @emre9039 ปีที่แล้ว

    Building a new steel building and shop area is 40' X 60' with 18' side walls 24' peak. What light would you recommend, how many and electrical load?

    • @CoydonLighting
      @CoydonLighting  ปีที่แล้ว

      We recommend you to use 10pcs 200W UFO LED high bay lights in a 2x5 pattern for your building

  • @futboleglence7309
    @futboleglence7309 ปีที่แล้ว

    Looking to light up a 60x90 20' ceiling. How many do I need?

    • @CoydonLighting
      @CoydonLighting  ปีที่แล้ว

      We recommend you to use 20pcs 200W UFO LED high bay lights for your building, you can place them in 4 rows of 5 fixtures.

  • @servet-zt7hk
    @servet-zt7hk ปีที่แล้ว

    30 x 40 with 12' sidewalls...how many, what wattage?

    • @CoydonLighting
      @CoydonLighting  ปีที่แล้ว

      We recommend you to use 8pcs 100W UFO LED high bay lights for your building, you can place them in 2 rows of 4 fixtures.

  • @mhikecabillo1709
    @mhikecabillo1709 ปีที่แล้ว

    Paano po gagawin pag patay n ung switch tapos my konti pang nkailw sa led?

    • @CoydonLighting
      @CoydonLighting  ปีที่แล้ว

      Please check the incoming line, whether the live line and the neutral line are reversed?