    @sahiljuned3762 2 ปีที่แล้ว +2

    Please one video auto addressing setting daikin vrv 4

  • @LC-qi5ff
    @LC-qi5ff ปีที่แล้ว +2

    Do you put the recovered refrigerant back into the CU via the charging port?

  • @pablochinchilla4372
    @pablochinchilla4372 3 ปีที่แล้ว +3

    No nitro flow..?

  • @muthusamy228
    @muthusamy228 2 ปีที่แล้ว +1

    Hi ! Mr bon If the capillary tube leaking should be the oil also come out right then replace the capillary tube need to top up oil or no need

    • @BonMj
      @BonMj  2 ปีที่แล้ว

      Depend by customer budget.$$
      Better replace the compressor.

  • @jcaniban6243
    @jcaniban6243 9 หลายเดือนก่อน +1

    Sir Bon do you need to recover the refrigerant or just bypassing? Same to the indoor unit when you do repair for vrv indoors you need to recover the refrigerant or just bypassing? It will help much thanks

    • @BonMj
      @BonMj  9 หลายเดือนก่อน

      Recover

  • @crispinplariza1503
    @crispinplariza1503 2 ปีที่แล้ว +1

    When reparing aircon we have to pump down its a right sir.

    • @BonMj
      @BonMj  2 ปีที่แล้ว

      U can lock the service vale and recovery the cu refrigerant .

  • @soelwinoo5280
    @soelwinoo5280 ปีที่แล้ว +1

    Hello, Mr.Bon, RXQ8PAY13 vrv3, firstly capillary tube was damaged and we have oil lost. I would like to know how many liter (mL) do we need to add after changing capillary tube. And then, i would like to know that the capacity of compressor oil in normal compressor. (inverter, standard1 and standard2 of VRV3). thanks!

    • @BonMj
      @BonMj  ปีที่แล้ว

      Hi, normally replace capirrally tube and compressor together is better way.i not sure how is the compressor oil level.

    • @soelwinoo5280
      @soelwinoo5280 ปีที่แล้ว +1

      @@BonMj thanks!

    • @salimagwan9672
      @salimagwan9672 ปีที่แล้ว

      Bon sar for what purpose you have set the setting of 2:40, please tell.

  • @DwiSeetyawanPKG
    @DwiSeetyawanPKG 2 ปีที่แล้ว +1

    Pak mau tanya, kalok mau ganti kompresornya apakah freon nya harus di pumpdown dahulu ke kompresor satunya jika di satu outdoor ada 2 kompresor

    • @BonMj
      @BonMj  2 ปีที่แล้ว

      Kalau ganti compressor,freon di outdoor harus di keluarkan.
      Freon di piping saja boleh simpan

  • @crispinplariza1503
    @crispinplariza1503 2 ปีที่แล้ว +1

    How we pump down before you repaired.

    • @BonMj
      @BonMj  2 ปีที่แล้ว

      Daikin not allow pump down.
      Only can do refrigerant recovery .

  • @biswamondal8082
    @biswamondal8082 3 ปีที่แล้ว +1

    Sir please tell me .Daikin 5.5 ton ductable air conditioner. error code . df-1 solution .

  • @mujeeb7100
    @mujeeb7100 3 ปีที่แล้ว +2

    Sir pls make a video on daikin vrv 3 odu discharge thermistor value how many Kilo ohms required and how to troubleshoot J2 error.

    • @Saito362
      @Saito362 3 ปีที่แล้ว

      I've been dealing with j2 and can't seem to find the problem 😕

    • @karthikrajesh5247
      @karthikrajesh5247 3 ปีที่แล้ว

      *I think the thermistor value should be normal when it shows 32 or 40 something which relates with atmosphere temperature. Upto 60-70 the thermistor is faulty.* For J2 error Outdoor Unit Standard Compressor Current Sensor may Fault or This is a fault with one of the standard compressor's current sensors.
      It occurs when the unit's PCB asks the compressor to run but then doesn't recognise that the compressor is drawing any current.
      *This can be due to a fault with the compressor contactor not coming in or a fault with either the Main PCB not giving an output to the contactor or not receiving the signal from the current sensor, or it could be a fault with the current sensor its self.*

  • @tora_100
    @tora_100 3 ปีที่แล้ว +1

    Daikin vrv 3 oil returns go this prblem

  • @mdsaifmdsaif3328
    @mdsaifmdsaif3328 3 ปีที่แล้ว

    God bless you sar❣️❣️❣️👌

    • @BonMj
      @BonMj  3 ปีที่แล้ว

      Thanks

    • @mdsaifmdsaif3328
      @mdsaifmdsaif3328 3 ปีที่แล้ว

      @@BonMj 😂😂❣️👌

  • @kroy2774
    @kroy2774 7 หลายเดือนก่อน +1

    What is The Capillary Size Bro

    • @BonMj
      @BonMj  7 หลายเดือนก่อน

      Suggest get it from Daikin

  • @vishalkumar-yc2km
    @vishalkumar-yc2km 3 ปีที่แล้ว

    Thanks very much sir.

    • @BonMj
      @BonMj  3 ปีที่แล้ว

      Thanks

  • @laukokhin1935
    @laukokhin1935 3 ปีที่แล้ว

    Sir, how to do pump down procedure in brand dikinnmulti outdoor.pls

    • @BonMj
      @BonMj  3 ปีที่แล้ว

      Do setting at main cu .

  • @mdsahiljuned8505
    @mdsahiljuned8505 3 ปีที่แล้ว +1

    Capillary size

    • @BonMj
      @BonMj  3 ปีที่แล้ว

      Original from daikin,i not sure

  • @mehedihasanasheek2518
    @mehedihasanasheek2518 3 ปีที่แล้ว +1

    💖💖💖💖💖

    • @BonMj
      @BonMj  3 ปีที่แล้ว

      Thanks

  • @karaors8970
    @karaors8970 2 ปีที่แล้ว +1

    👍

    • @BonMj
      @BonMj  2 ปีที่แล้ว

      Thanks

  • @kkwong4104
    @kkwong4104 3 ปีที่แล้ว

    HiBonmj 大金冷氣out door 按reset你個D嗎

    • @BonMj
      @BonMj  3 ปีที่แล้ว

      如果外机关切断电源重开,建议reset.

    • @kkwong4104
      @kkwong4104 3 ปีที่แล้ว

      @@BonMj thx

  • @slavamavashev8083
    @slavamavashev8083 2 ปีที่แล้ว +1

    👍

  • @slshen4524
    @slshen4524 ปีที่แล้ว +1

    👍

    • @BonMj
      @BonMj  ปีที่แล้ว

      Thanks