Installing an Outlet… For a Toilet Seat?!

แชร์
ฝัง
  • เผยแพร่เมื่อ 17 พ.ย. 2024

ความคิดเห็น • 3.4K

  • @civildisorder
    @civildisorder ปีที่แล้ว +5743

    The brace falling out of position over and over was the most real mood I've had watching one of these.

    • @questieee
      @questieee ปีที่แล้ว +31

      Gotta put 'me and the birds - duster' in the background

    • @Cannotoad1201
      @Cannotoad1201 ปีที่แล้ว +21

      10:13

    • @katrinabryce
      @katrinabryce ปีที่แล้ว +18

      I would have used some blu tack or masking tape to hold it in place.

    • @realcartoongirl
      @realcartoongirl ปีที่แล้ว +5

      10:10

    • @Science-Vlog
      @Science-Vlog ปีที่แล้ว +3

      i have lost my sole in this online world

  • @MaverickBlue42
    @MaverickBlue42 11 หลายเดือนก่อน +2182

    As an electrician, it's not often that we get to see an electrical engineer actually do electrician things. It was quite refreshing to see an engineer feel our pain...well done tho :)

    • @raffaelflugge5271
      @raffaelflugge5271 11 หลายเดือนก่อน +143

      As a german electrician my whole body clenched because all Our ruleing is so damn strict, i feel like He has broken at least a hand full of laws and defiled the entire DIN

    • @Mentaculus42
      @Mentaculus42 11 หลายเดือนก่อน +30

      @@raffaelflugge5271
      I believe he has broken multiple California electrical codes also. But at least in California, to do this work you have to have it inspected, no exceptions. If anything, I think that this video was a bit inappropriate as presented to have on youtube.

    • @MaverickBlue42
      @MaverickBlue42 11 หลายเดือนก่อน +61

      @@Mentaculus42 It's perfectly legal for a homeowner in Ontario to do their own electrical work in their home, however they do need to have it inspected afterwards while the wires are still exposed and accessible. I assume he left that part out of the video, because why include it? Regulations are different in every jurisdiction, even within the same country, let alone across the world.

    • @Mentaculus42
      @Mentaculus42 11 หลายเดือนก่อน +21

      @@MaverickBlue42
      AND it is perfectly legal in California, providing it is inspected, so we agree, AND the video should mention that to be complete and responsible to people’s safety.

    • @MaverickBlue42
      @MaverickBlue42 11 หลายเดือนก่อน +6

      @@Mentaculus42 That's fair.

  • @YimYum911
    @YimYum911 11 หลายเดือนก่อน +337

    Y’all complain about studs but we have solid concrete walls 💀

    • @marioskoczek4
      @marioskoczek4 6 หลายเดือนก่อน +5

      1 year laser hi today i will show you how to make a toilet seat Warmer and sprayer

    • @DihasNanayakkara
      @DihasNanayakkara 6 หลายเดือนก่อน

      Same

    • @JuxtaposedOver
      @JuxtaposedOver 5 หลายเดือนก่อน

      😢

    • @ANDRE-ys4yd
      @ANDRE-ys4yd 5 หลายเดือนก่อน +3

      in my home, I have solid bricks that are full so it's even worse and also the walls are really thick because my house is ancient like from the 1800s

    • @psilocybemusashi
      @psilocybemusashi 5 หลายเดือนก่อน

      never heard of it

  • @Cametek.CamelliaOfficial
    @Cametek.CamelliaOfficial ปีที่แล้ว +981

    As one of Japanese ElectroBoom watchers, I appreciate your accurate compliment towards our toilet shower (washlet) system. I'm glad you like it

    • @AfsYan
      @AfsYan ปีที่แล้ว +25

      lol camellia

    • @monomelon
      @monomelon ปีที่แล้ว +43

      camellia is a electroboom enjoyer too lets go

    • @yolkosu708
      @yolkosu708 ปีที่แล้ว +32

      seeing camellia here is so crazy 😂

    • @syahminorizan8064
      @syahminorizan8064 ปีที่แล้ว +8

      Ay yo Camellia?!

    • @Maninawig
      @Maninawig ปีที่แล้ว +9

      Yeah, North Americans are kinda fascinated with how Japanese toilets have 10k buttons. Tourists have many names for them, but it sums up as Heaven's Luxury at the Base Model.

  • @hugegamer5988
    @hugegamer5988 ปีที่แล้ว +1184

    Next do an in-line 220V electric heater next to the shower head! It’s those extra tingles with the warm water that really get you moving in the morning.

    • @thepolymorphicaris1939
      @thepolymorphicaris1939 ปีที่แล้ว +17

      😂😂😂

    • @jeffarends8843
      @jeffarends8843 ปีที่แล้ว +37

      When I was in Manila, I experienced those tingles.. then I decided to use a different shower

    • @BrokenAtari
      @BrokenAtari ปีที่แล้ว +59

      Industrial 500v service, I want the shower head hot enough to forge steel.

    • @timhartherz5652
      @timhartherz5652 ปีที่แล้ว +17

      The bigclive showed one of these deathtraps, the perfect place for an outlet is right next to said shower head, ungrounded of course.

    • @timothyschollux
      @timothyschollux ปีที่แล้ว

      th-cam.com/video/06w3-l1AzFk/w-d-xo.html

  • @Raizazel
    @Raizazel 11 หลายเดือนก่อน +43

    Just installed one of those non-electric bidet seats at my place. It's a simpler version than others but feels more reliable. No electricity needed - it hooks right up to the hot/cold water from the basin. Only cost me 30€ and it's perfect for a rental. Depending on your setup, you might not even need to do major work, just attach the hoses. Got it ready in just a few minutes. Super straightforward and efficient.

  • @TheStrykerProject
    @TheStrykerProject 11 หลายเดือนก่อน +937

    Mehdi not only showed that a) projects like this are possible, and b) that they are, indeed, awkward and difficult, but he showed you can do most of it with ONE HAND! 🤯

    • @davejones542
      @davejones542 11 หลายเดือนก่อน +4

      what was his other hand doing

    • @doderiolarkisso4038
      @doderiolarkisso4038 11 หลายเดือนก่อน +48

      @@davejones542 holding the camera, as he stated in the video.

    • @TheStrykerProject
      @TheStrykerProject 11 หลายเดือนก่อน +14

      @@davejones542 holding the camera 😆

    • @physicsguy6625
      @physicsguy6625 11 หลายเดือนก่อน

      ​@RepentandbelieveinJesusChrist5
      Chutiya hai jesus

    • @28russ
      @28russ 11 หลายเดือนก่อน

      @@davejones542You could see how happy and excited this made him........He was holding his "camera" 🍆😉😂

  • @2pointSummer
    @2pointSummer ปีที่แล้ว +589

    8:17 this has to be the most Mehdi method there is of testing if it's safe to touch or not

    • @manjudhaka6772
      @manjudhaka6772 ปีที่แล้ว +8

      Lol😂

    • @geordonworley5618
      @geordonworley5618 ปีที่แล้ว +5

      It cracked me up so much when he did that.

    • @ammarchangwani9
      @ammarchangwani9 ปีที่แล้ว +2

      😂😂😂😂

    • @leepshin
      @leepshin 11 หลายเดือนก่อน +3

      The "Mehdi Method"....I like that. lol

    • @maritoguionyo
      @maritoguionyo 9 หลายเดือนก่อน +2

      Touch touch

  • @akarigoshihime3900
    @akarigoshihime3900 7 หลายเดือนก่อน +13

    You inspired me to go into the electrical trade. Went to school and everything. You still teach me new things and i love it. Your videos are fun and educational while being a clear example of what not to do at many times. I love your content and hope you have fun making these videos

  • @gradesam6306
    @gradesam6306 ปีที่แล้ว +1807

    it's amazing that if you're an electrical engineer you can just spawn power sockets for your convenience.

    • @RindosRides
      @RindosRides ปีที่แล้ว +148

      I dunno about where he lives, but in my state it's illegal unless you are a certified electrician. So basically you have to pretend any outlet or switch you alter was done that way already.

    • @windyr
      @windyr ปีที่แล้ว +231

      ​@@RindosRides I document exactly what I install for that very reason, with a lot of detail. If a house burns down because of some home brewed shit and the owner says "the electrician did it", I can point to the documentation and say "no I didn't"

    • @BrainStormzFTC
      @BrainStormzFTC ปีที่แล้ว +54

      You sure your state doesn't have "owner/builder" provisions? It's hard to imagine any state having more restrictive building code than California

    • @Mentaculus42
      @Mentaculus42 ปีที่แล้ว +16

      Technically it should have been inspected by a governmental inspector and had a building permit. If something bad happens, your insurance company could have some difficulty questions for you. Personally I have seen too much crap installed by people who don’t know what they are doing or are purposely being cheap. I have seen new construction that in theory was inspected that is crap.

    • @FurqanHun
      @FurqanHun ปีที่แล้ว +26

      @@RindosRides Mehdi lives somewhere in canada ik that cuz of the Linus collab in the past and he also has mentioned it somewhere, he has a master's degree in Applied Sciences, and also has worked as a professional till few years ago

  • @stanleydenning
    @stanleydenning ปีที่แล้ว +1217

    I think that ElectroBoom did a pretty good job. Reto-fitting electrical wiring can be a pain in the ars.

    • @bosanaz2010
      @bosanaz2010 ปีที่แล้ว +95

      ask us in germany..solid walls or even beton^^

    • @Görkem-x5h
      @Görkem-x5h ปีที่แล้ว +28

      @@bosanaz2010 wait do Germans call it beton as well? We call it beton in Turkiye too.

    • @puellanivis
      @puellanivis ปีที่แล้ว +39

      @@Görkem-x5h yes, Germans call it Beton. Looking up “beton” in Turkish on wiktionary, it seems we both borrowed it from French béton, from Latin bitūmen.

    • @ZeroOneInfinity
      @ZeroOneInfinity ปีที่แล้ว +17

      Being from England we just stole the word, removed the unnecessary line above the u and called it bitumen.

    • @Nikola_W211
      @Nikola_W211 ปีที่แล้ว +7

      ​@@puellanivissame here in croatia

  • @ryanlewis4953
    @ryanlewis4953 ปีที่แล้ว +476

    Electrician comment here! Next time, as you pointed out, use a box that clamps on the dry wall instead. The lower example is the one I like. For the cut out on those it's best to just use a credit card as the template and you'll get the perfect size.

    • @ProtoV33MK1
      @ProtoV33MK1 ปีที่แล้ว +23

      Wait really? Those are the same dimensions? I've always just traced the box. Thanks for that info.

    • @nyer070
      @nyer070 ปีที่แล้ว +68

      Dude... That stud is no longer a stud... The hole was so big that the sides looked like toothpicks.

    • @manadoria
      @manadoria ปีที่แล้ว +5

      Yep. Usually they are in the same aisle, except in a section that is labeled for "old construction". This is not just limited to receptacle boxes as well.

    • @masonoliver8818
      @masonoliver8818 11 หลายเดือนก่อน +3

      Rack-a-tiers makes a template with a built in level that let's you trace the perfect hole for both plastic or metal old work boxes. It's cheap and saves so much time if you're constantly cutting in pop in boxes like me

    • @NakamoriAra
      @NakamoriAra 11 หลายเดือนก่อน +8

      You forgot to mention he forgot the anti short bushings 😂

  • @cosinusjay
    @cosinusjay ปีที่แล้ว +361

    Having an outlet right next to the toilet would be a dream. Imagine the new possibilities! Watching Mehdi while charging your phone!

    • @Tosti_bakker
      @Tosti_bakker ปีที่แล้ว +9

      Oh yeah totally what I was thinking too!... And nothing else

    • @jonc4403
      @jonc4403 ปีที่แล้ว +16

      I put one in for the bidet - and now I'm about to wall mount a laptop by the toilet.

    • @GenskiMusic7857
      @GenskiMusic7857 11 หลายเดือนก่อน

      Probably gonna be your last day tho@@jonc4403

    • @bosanaz2010
      @bosanaz2010 11 หลายเดือนก่อน

      ITS Not...i Had IT in nearly every Rent flat.....you ass fuses to the Bowl...NoNo ITS Like a Lifetime McDonald's for free...Sounds great,but in the end you get cancer

    • @SproutyPottedPlant
      @SproutyPottedPlant 11 หลายเดือนก่อน +1

      Pull yer wire!

  • @lewisdepatserlord4737
    @lewisdepatserlord4737 11 หลายเดือนก่อน +104

    6:06 average technician's reaction when they realize their job just became 10x harder to do

  • @avennon1873
    @avennon1873 ปีที่แล้ว +264

    I'm studying electrical right now and I love watching you explain everything as if you have no idea whats going on, then doing safely dangerous things to teach. I wish my teachers could do funny stuff like this in the shop but I'm sure insurance would kill them before the electricity.

    • @miinyoo
      @miinyoo ปีที่แล้ว +8

      Heh. Band of assassin insurance brokers. I like it.

    • @birthdayrosie3410
      @birthdayrosie3410 11 หลายเดือนก่อน +4

      @@miinyooyour mom

    • @avenger3163
      @avenger3163 4 หลายเดือนก่อน

      @@miinyoo Boeing would like to know your location.

  • @grbansen
    @grbansen ปีที่แล้ว +179

    Other than grounding the boxes properly you should have used an "anti-short" on both ends of the cable. It's red and made of plastic that protects the wires from the metal sheathing.
    Other wise good job.

    • @advikbhushan7652
      @advikbhushan7652 11 หลายเดือนก่อน +22

      He did that in his patio heater video but forgot in this one

    • @sgath92
      @sgath92 11 หลายเดือนก่อน +12

      I don't know how he could forget the redhats a 2nd time around. He made a whole follow up video about it the last time he was called out for it!

    • @CheapFlashyLoris
      @CheapFlashyLoris 11 หลายเดือนก่อน +29

      ​@@sgath92 He was clearly just distracted by needing to poop the entire time

    • @bertjesklotepino
      @bertjesklotepino 11 หลายเดือนก่อน +9

      it shows he is not an expert.
      Experts would not make that mistake twice.
      O wait, even experts can make the same mistake twice.
      I guess he is human?
      Nah, that can't be it.
      Wait, he is the Crazy Iranian Hacker. Brother of the Crazy Russian Hacker.

  • @janekilIer
    @janekilIer 3 หลายเดือนก่อน +4

    this reminds me of my grandmas house that was built in like the late 70s and there was an outlet right next to the sink ON THE COUNTER. for "convenience" but thankfully she had someone remove it a few years back

  • @PurlCat
    @PurlCat ปีที่แล้ว +85

    Im an electrician (actually just south of Electroboom across the border ;) )and we do a lot of residential remodels. Medhi came up with a lot of methods that we use all the time like how he fished the metal sheilded cable into the box with a piece of metal.
    Btw, an "outlet" is anywhere where line voltage is available, as in constant power, not switched power. So technically all boxes where switches are located in your house (unless they are 3 or 4 way switched) are outlets, as well as every receptacle (what everyone calls an outlet) location. Atleast thats what my boss tells me.

    • @macaddct1984
      @macaddct1984 ปีที่แล้ว +5

      I don’t think any of these methods were new to Medhi. 😉 He plays the part well though!

    • @Mentaculus42
      @Mentaculus42 ปีที่แล้ว +2

      I once watched a cable installer use super strong magnets to fish wires within the walls. Personally I use those fiberglass rods that can be extended, but it is a pain.

    • @aaronevans8701
      @aaronevans8701 ปีที่แล้ว +3

      Here in Australia, we call our standard 10A outlets GPO's (general purpose outlet). It does 240V/10A. There are also identical looking ones, but with a wider earth plug, that do 240V/15A for higher current use cases, like caravans, and some ovens.
      For more industrial/commercial uses, 5 pin 3 phase is also very common.
      All of our circuits are on RCD switches, usually at the main pannel/distribution board. There are some instances where individual GPO's have their own RCD on them at the outlet, but that's not very common.

    • @gg-gn3re
      @gg-gn3re ปีที่แล้ว +1

      @@macaddct1984 yep it's pretty amazing how many people don't get that, even 10 years later.. he's acting.

    • @PurlCat
      @PurlCat ปีที่แล้ว +1

      @@macaddct1984 I mean he got the general ideas right but all his methods were still a bit crude. The fact that he has rough-in photos of his house does sorta imply that he had some hand in the building process, either in helping plan/design with the contractors and subs or he actually helped build it.

  • @ericthecyclist
    @ericthecyclist ปีที่แล้ว +247

    Once you have one, it feels primitive/backwards when you get stuck using a legacy toilet elsewhere.
    Got a bidet toilet seat a year before covid; it was also a life-save during the great toilet paper shortage.

    • @harrycushing
      @harrycushing ปีที่แล้ว +41

      As someone yet to use a bidet, I find it hilarious that you refer to bidet-less toilets as a "legacy toilet" lol, must be life changing

    • @vhfgamer
      @vhfgamer ปีที่แล้ว +10

      Can't think of anything more unpleasant than having nasty toilet water shot at me while I'm trying to go to the bathroom.

    • @ericthecyclist
      @ericthecyclist ปีที่แล้ว +9

      Its like the difference between using an out-house versus a flush-toilet with indoor plumbing.

    • @ericthecyclist
      @ericthecyclist ปีที่แล้ว +53

      @@vhfgamer There is a t-junction at the water supply to your toilet, so it's fresh water that wasn't even in the tank. The water is heated on demand to the temperature you like, and it only happens when you press a button (ie, when you'd normally be reaching for some toilet paper). There is a blower to dry off your backside, also user controllable temperature. But I understand, back in the day, there were probably people who couldn't understand why somebody would replace their perfectly good out-house with indoor plumbing and a flush toilet.

    • @vhfgamer
      @vhfgamer ปีที่แล้ว +1

      ​@@ericthecyclist Yeah. The bidet is like the outhouse.

  • @its_captain_aardvark
    @its_captain_aardvark 11 หลายเดือนก่อน +23

    Hey Electroboom, I just want to thank you because your videos have actually helped me in physics class. Your explanation of diodes, capacitors and resistors and such. It actually helped me alot. Thank you Electroboom!

  • @osgeld
    @osgeld ปีที่แล้ว +295

    really should have an insulator at the ends of the armor flex so it wont potentially cut into something and become live (they sell these little red plastic / rubber plugs just for that) to be 100%

    • @SomeGuysGarage
      @SomeGuysGarage ปีที่แล้ว +43

      As is required by code here, they're called anti-short bushings.

    • @NickBeeee
      @NickBeeee ปีที่แล้ว +28

      He might've installed them off camera, as in a separate vid about his back porch infrared heater, he showed just that

    • @peterfordham3562
      @peterfordham3562 ปีที่แล้ว +22

      ​@@SomeGuysGaragehe forgot those on the garage heater install to and ended up doing a follow up video where he installed them. Surprised he forgot again.

    • @noahbones1221
      @noahbones1221 ปีที่แล้ว +1

      those are not required on MC/greenfield cable here in the USA. not sure about canada though.

    • @Beeeeeeeeeee
      @Beeeeeeeeeee ปีที่แล้ว +6

      If it does become live, the gfci will pop. That's what it does.

  • @I-like-cows
    @I-like-cows ปีที่แล้ว +141

    Stumbling across this channel while dealing with college is the best thing that happened to me for a long time thank you electro boom you're great

    • @beanapprentice1687
      @beanapprentice1687 ปีที่แล้ว +2

      Welcome

    • @alext7074
      @alext7074 ปีที่แล้ว

      Welcome!

    • @noskatehate
      @noskatehate ปีที่แล้ว +4

      You've gotta check out the episode where he tests the outlets in his hotel room in Hawaii. You'll thank me later 😂

  • @Owen_loves_Butters
    @Owen_loves_Butters 11 หลายเดือนก่อน +185

    2:16 Well who didn't see that coming?

    • @bluecrew5248
      @bluecrew5248 9 หลายเดือนก่อน +5

      me

    • @mernokimuvek
      @mernokimuvek 8 หลายเดือนก่อน

      It was faked. If you stop at 2:18 you can see that the probes are not plugged into the multimeter.

    • @doxzlaborathory
      @doxzlaborathory หลายเดือนก่อน

      probe was not connected to Multimeter, probably there was capacitor on the other end

    • @doxzlaborathory
      @doxzlaborathory หลายเดือนก่อน

      probe was not connected to Multimeter, probably there was capacitor on the other end

  • @panemon187
    @panemon187 11 หลายเดือนก่อน +12

    When using a metal box, you should consider making a bonding pigtail to your ground and have it wrapped around a grounding screw which is mounted to the frame of your box. You also want to make sure you put your stud hole about 6 inches above your receptacle, and clamp the conduit down against the stud.
    This will give you extra protection and it's code in some places. It's also a good idea to wrap your exposed receptacle screws with electrical tape as well. This way you don't short something out and your box has a path to ground to prevent you from energizing the box and shocking yourself. (I like to use antiox on my copper conductors in wet areas to protect against moisture and oxidation of the conductors.)
    Leviton makes a WAGO style receptacle connector, which makes installing these much easier, you just push the wire in and snap it closed. Consider using Wagos instead of wirenuts, they will give you more space to work with in your box. (I wrap those in color coded tape to prevent the levers from coming back up)
    I would have bought a plastic box for the bathroom. Metal boxes are a headache imo, but they hold up well to heat in-case there is a lose connection or potential fire situation.

    • @darrenwoloshyn
      @darrenwoloshyn 9 หลายเดือนก่อน +1

      No one uses plastic boxes in Canada. There's only Plastic Nutek boxes that we use on rough in new construction for exterior walls.

  • @hhjones9393
    @hhjones9393 11 หลายเดือนก่อน +195

    Just like Mehdi I took pictures of my house before the sheetrock went up. It is so handy to have later on for repairs or additions! I was worried for him that the hole he planned to use was meant for the sink drain line. I guess either it wasn't or he worked around it without telling us.

    • @RipVanFish09
      @RipVanFish09 11 หลายเดือนก่อน +4

      Imagine if it was meant for the sink, and he managed to bust the pipe. OOOF.

    • @Idiomatick
      @Idiomatick 10 หลายเดือนก่อน +3

      You can see the sink drain line in the picture he took.

    • @UserOfTheName
      @UserOfTheName 10 หลายเดือนก่อน +6

      They should keep construction photos and include the house when you buy it. Renovating a home is like opening a mystery box only instead of finding a rare png you find a 4 inch void above the door frame hidden by base boards and a pile of rusted exacto blades.

    • @joseherrera8489
      @joseherrera8489 6 หลายเดือนก่อน

      @@UserOfTheName how would that work with houses built pre-WWI? There's still tons of those in big cities.

    • @UserOfTheName
      @UserOfTheName 6 หลายเดือนก่อน +2

      @@joseherrera8489 It wouldn't but It doesn't mean new homes shouldn't

  • @patrickzavas
    @patrickzavas ปีที่แล้ว +21

    You should pick up a meter that has the Loz setting. It tests for voltage while applying a small load. You can use it to test GFCIs and you can also use it to get a true reading without any ghost voltage. Sometimes there can be a very loose connection or wires just traveling next to each other for a long period of time and a voltage will show on a wire that does not have any power. This Loz setting eliminates the ghost voltages.

    • @LOLMAN9538
      @LOLMAN9538 ปีที่แล้ว

      Would it also require you to place a 10K resistor between live and earth or would it eliminate that need?

    • @ghostali8351
      @ghostali8351 ปีที่แล้ว +1

      ​ It has already built in somehow so u don't need anything else

    • @Kwauhn.
      @Kwauhn. 11 หลายเดือนก่อน +2

      Legend of Zelda setting

  • @talalaziz1531
    @talalaziz1531 4 หลายเดือนก่อน +4

    this man is the most funniest teacher I have ever seen. This man has to fricking turn off the full power of his room, get third degree burns, almost dying, almost losing his vision, almost demolishing his house, LIKE THERE IS SO MUCH MORE. You are the main reason I have an inspiration to use ELECTRICITY and hopefully not get eviscerated by the cables. Thank you...

  • @IsacCraft2009
    @IsacCraft2009 ปีที่แล้ว +21

    2:38 POP IT AGAIN!!! HERE WE GO!!!!

  • @Rulerofwax24
    @Rulerofwax24 ปีที่แล้ว +115

    Seeing Mehdi try to screw in the conduit brace, I now know that I need to gift him a mini tripod for Christmas.

    • @bobafettjr85
      @bobafettjr85 ปีที่แล้ว +11

      This is a man who used a 10k ohm resistor, voltmeter, and light bulb to check the GFCI instead of the outlet tester he most definitely has. He will not use the mini tripod if he thinks it will make life easier.

    • @bhanuchhabra7634
      @bhanuchhabra7634 11 หลายเดือนก่อน +2

      And he will shoot while holding the tripod 😅😅😅

    • @PMA_ReginaldBoscoG
      @PMA_ReginaldBoscoG 11 หลายเดือนก่อน

      A GoPro would do the work 😅

  • @professordey
    @professordey 11 หลายเดือนก่อน +4

    In my limited understanding, this sort of setup would never be allowed in the UK due to 'splash zone' exclusion rules for outlets. I believe that if you wanted to do something like this and have the socket within 5 feet of a water source (Particularly a sink or toilet tank that can flood the room if the normal overflow control measures fail) is if you use a completely plastic and waterproof in-wall access box which you run a cable directly into without a plug, just a lot of waterproofing before it's connected directly to the mains AC through a fuse. Good ones have watertight but removable fuses as I very vaguely recall. They're also used a lot for electric radiators as it's far safer to have such a high current device directly wired in much like an oven or the like, especially when it may contain conductive fluids or be around water itself.

    • @hallsofvalhalla1749
      @hallsofvalhalla1749 7 หลายเดือนก่อน

      I have never seen GFCIs at the point of use in a british home. I have seen GFCI outlets available, but they don't seem to be nearly as common as they are in the states.
      Codes aside, I still find it a bit odd that bathrooms in the USA have regular outlets in them, even if they are GFCI. Plenty of outlets in my home were wired incorrectly. I've also had electricians come in and do a bad job of wiring outlets (they had to get redone).
      So, it's a good idea to get an outlet tester when you buy a new home, and test all of your outlets and make sure they are grounded and the hot is wired to hot etc.
      Oh, did I say that I found a switch where someone had cut the ground? The wire had to be rerun............
      That turned into a bit of rant.........

  • @stevesether
    @stevesether ปีที่แล้ว +27

    Pretty good job.
    Only thing I'd add is, when working with metal flexible conduit (what we used to call BX), use a red head at the end to protect against the metal cable cutting the conductors.
    I thought it was required by code, but apparently it's just a "best practice".

    • @snakeinthegrass7443
      @snakeinthegrass7443 ปีที่แล้ว +6

      You're correct - it's required. The list of violations in this vid is long.

    • @3nertia
      @3nertia 11 หลายเดือนก่อน +6

      @@snakeinthegrass7443 But just look at the boost to engagement he's gotten by editing out all the footage of him doing those things ;)

    • @stevesether
      @stevesether 11 หลายเดือนก่อน +1

      @@snakeinthegrass7443 All the electrical forums I've found seem to indicate red heads aren't required, but highly recommended.
      If you disagree, can you provide the relevant section in the NEC code? I can't prove a negative, but you can provide code references to show they're required.

    • @snakeinthegrass7443
      @snakeinthegrass7443 11 หลายเดือนก่อน +9

      @@stevesether I'm shocked! When I started in the biz, all there was available was BX cable. Then when MC came out, the manufacturers still attached a bag to the roll so I hadn't realized anything had changed. I should've known something was up when they started sending bags with 5 bushings in it and then it stopped completely. Every electrician I know still uses them, but after a very quick search just now, I see you are correct - they are not required. It's my belief that this was done not because there is a ground wire inside now, but rather the armor is no longer steel - it's aluminum. I don't know how either of those situations would eliminate the need for a redhead, anti-short, bushing - however we say it.
      Thank you for forcing me to correct myself. I will always continue to use them because it seems crazy not to. And the way he unraveled the outer jacket was insane!! I would've loved to see the actual cut he made in the armor when he was done. That is the sharpest part and if it's not done carefully, there will be a very small razor in there just waiting for the next guy to get it. One of the saddest part is that he didn't have to use MC at all. He could've just used Romex because it is not subject to damage inside the cabinet. And that would've eliminated two violations because (1), you can not shove armored cable into the clasp of a plastic box that's designed for Romex. And (2), the metal box he bought that he had no idea how to use, was in fact the wrong box. That too was designed for NM cable. The screw-down clamps inside that box were absolutely the wrong ones to use. Using those type will def lead to increased risk of being cut by the armor because the proper clamps are designed so the the wire can't bend at the armor - it bends at an extended portion of the clamp. It's not there!
      I know he goofs around and plays dumb a lot, that's what makes his channel unique. But this one wasn't an experiment in his lab. It's a permanent part of the electrical system in his home where his family lives, and that's nothing to play around with. Sorry for ranting but this has been my life for almost 40 years and this was truly hard to watch.
      Thanks again for teaching me something new that I will NOT be passing along to my colleagues. 🤣🤣 God bless and stay safe!

    • @stevesether
      @stevesether 11 หลายเดือนก่อน +3

      @@snakeinthegrass7443 Honestly I thought the red-heads were required as well. I like to check my assumptions, so I did some quick googling and was surprised to learn they're not required.
      With that said, I'd never not install them, and I've put a good many of them in my own house. I'm not an electrician, only a DIYer that generally knows what I'm doing.
      My house sadly didn't have this luxury of having someone who knows what they're doing work on the electrical. I've replaced quite a lot of the hack work over the years, so I'm familiar with how people REALLY screw things up. Just finally got all my ground wires working everywhere, which someone, 30 years ago, forgot to hook up a ground, in some unknown spot.

  • @ReadTheShrill
    @ReadTheShrill ปีที่แล้ว +11

    Tip: 10:12 - Put the curved side of the bracket into a pair of lineman's pliers* and "bite" down just enough to hold it. Slip the bracket over the wire sheath, and bite down hard enough to bend the bracket a little, but not enough to bend the sheath. Then the bracket will hold on to the sheath nicely while you drive the screw in. I did a lot of wiring in my attic, and this saved me a lot of time.
    (*Lineman's pliers worked best for me, but I suspect it will work fine with any pliers that have serrated jaws)

  • @G.A.N.
    @G.A.N. 7 หลายเดือนก่อน +3

    i was watching the struggle at 10:10 but i had to pause a video when i saw a smoking car outside, what a hal hour LIVE show outside. Noone got hurt and air smells nice after that car combusted. What a lovely monday we have today.

  • @mysa39
    @mysa39 ปีที่แล้ว +45

    Coming from Europe I'm always surprised to see all electrical cabling in metal (now I know why thanks) the metallic plug boxes and the exposed live and neutral screws... It's all plastic and covered here, and it feels so much safer. But maybe it's just because I'm used to it?

    • @benjurqunov
      @benjurqunov ปีที่แล้ว +7

      In US past 60 some years, it's pretty rare to see metallic clad cables installed in residential constructions.
      Said that, this guy's application is a perfectly sound example reasoning that some part of the drawer mechanism could fail and pinch against the cable.
      Exactly right about the hazards of exposed screw terminals and non shielded connector pins.
      For electrical safety, The US is seriously lacking in many regards.

    • @tier3rd375
      @tier3rd375 ปีที่แล้ว +5

      Metal electrical boxes are required to be bonded to ground for the precise reason of having a return path should the box become energized. Also, while not a requirement by code, it's highly encouraged to wrap the screw terminals of a receptacle in a metal box in electrical tape.
      Typically, electrical conductors are not wrapped in metal. They're usually wrapped in a plastic sheath. A popular brand is "Romex".
      Also, not excusing our serious lack of electrical safety, we use 120v for everyday residential use while Europe mostly uses 240v. So I believe that plays a part in why Europe has more requirements for electrical safety than the US. We also use 240v, but only for large appliances such as clothes dryers that don't typically get disconnected from power on a regular basis.

    • @stevesether
      @stevesether ปีที่แล้ว

      @@benjurqunov Highly dependent on the age of the house. Before "Romex", i.e. non-metallic cable became popular in the 60s, and definitely in the 70s, BX wire with metal cladding (originally steel, now AL) was generally used. My house was built in 24, and it's a mix of BX and Romex.

    • @ghostali8351
      @ghostali8351 ปีที่แล้ว +1

      And I'm amazed that Wagos isn't a requirement in the US

    • @stevesether
      @stevesether ปีที่แล้ว +1

      @@ghostali8351 There' nothing unsafe about wirenuts. In some ways they're slightly better since the resistance is a little lower. Code should be based on experience in the field, not irrational fears.
      We've been using them here for 60+ years, and they just aren't a problem if you use them right. All you have to do is give them a slight pull to make sure they're in properly.
      Wagos sometimes approach $1 a piece or so in smallish numbers of 30 or so. I'd rather just buy the wirenuts once and be done with it.

  • @abbeyoneworld
    @abbeyoneworld ปีที่แล้ว +30

    2:43 😂😂😂😂😂😂😂 mehdi is something else

  • @georgeprout42
    @georgeprout42 11 หลายเดือนก่อน +3

    09:34 add a string. It doesn't do anything, but is there if you ever need to pull another wire through the same channel. Rinse and repeat. But always leave a pull in place.

  • @Dug88
    @Dug88 ปีที่แล้ว +4

    Nice. No drywall patching. That hole in the stud worked out really well. It would have been a pain to have had to cut the wall to get a drill in there in that space. Trying to get things through people's walls can be a nightmare. Especially in older houses.
    A lot of older houses have horizontal or angled cross members between studs. A lot of electricians also used to box their electrical boxes in with would and they would usually block off the entire stud space. Trying to get anything up a wall in a house like that usually means cutting drywall and cutting or drilling behind the wall.
    There was one customer where we were trying to get a thermostat wire up from a crawl space. The fish tape just wouldn't go through, turns out whoever drywalled the house crammed all the drywall offcuts into the walls. The entire wall was full of broken chunks of drywall. We ended up having to dig a bunch of it out of the wall to get the wire up.

  • @ButteredCarpet
    @ButteredCarpet ปีที่แล้ว +19

    7:31 that's what he said

  • @turtlepowa
    @turtlepowa 11 หลายเดือนก่อน +65

    I would love to see some "testing" on some vintage electrical direct current model trains to see how safe they are

  • @tmo26
    @tmo26 ปีที่แล้ว +19

    That eyeborow wiggle @14:17 is epic! 😀

  • @aussiebloke609
    @aussiebloke609 11 หลายเดือนก่อน +45

    13:26 That's one reason I prefer to use the plastic boxes - no need to ground the box. There's also the advantage that if the outlet ever gets loose, it can't short the side terminals against the box accidentally - and as there's a limit to how many connections you should put in each size box, having one less pigtail makes the job easier. 👍

    • @snoopdogie187
      @snoopdogie187 11 หลายเดือนก่อน +4

      Benefit of the metal box, if the electrical ever starts to burn, the box won't be harmed, and possibly even stop the fire.

    • @jeevana.6391
      @jeevana.6391 11 หลายเดือนก่อน +1

      I prefer metal boxes. You just ground them and there's no need to ground devices individually. Plus they don't flex or anything.

    • @WJCTechyman
      @WJCTechyman 11 หลายเดือนก่อน +2

      @@jeevana.6391 I am pretty sure that only grounding the boxes is against what the Canadian and American electrical codes say. I also think the reason we ground our devices as well (in Canada we don't ground light switches, which is fine, but some would disagree) is for redundancy sake. I am not an electrician but I came across a set of lights in our basement that had a few problems: There weren't strain reliefs on the non metallic (Americans refer to it as Romex) cable running to each octagon box, so I pulled those boxes and put in the strain reliefs required, the connections where Marettes (wire nuts to those in the US) were supposed to be used were twisted together and only electrical taped so of course I put Marettes on those connections and also had to make new pig tails at each box so they were grounded. I couldn't use the lights so in their place I put electrical outlets as I wanted to put shelves against that wall and maybe plug some lights into those for each shelf.
      That job, working in awkward positions is definitely relateable to Mehdi putting those clamps in to hold the wire, I had to work above my head for those.

    • @jeevana.6391
      @jeevana.6391 11 หลายเดือนก่อน +3

      @@WJCTechyman Grounding the box only is code compliant as long as whatever connected has a path to ground. They're called self-grounding devices. Outlets have their ground connected to the same strip of metal as the screws do and you can usually see a bit of brass on the mounting ears specifically for this. Most lights are the same. If installing something that doesn't have that path, say a type of light fixture, then it needs to be grounded via wire.
      Also I don't know how applicable it would have I'm your case, but learning how to drywall has been the best thing when doing any projects involving running wire. It's so much easier to work while not cramped and hoping you can poke something through a hole a metre away.

    • @eDoc2020
      @eDoc2020 11 หลายเดือนก่อน +2

      Fun fact: plastic electrical boxes in Canada have metal straps, so you still need to ground them. It was surprising when I learned this. Also btw I don't believe ground wires count towards box fill.

  • @tumo07
    @tumo07 11 หลายเดือนก่อน +4

    8:12 that’s why newer gfci works by monitoring the power between live and neutral and cut power when there is a difference
    You should make a video on types of gfci to educate us

  • @paulevans9307
    @paulevans9307 ปีที่แล้ว +44

    Out of all the cleaning methods you mentioned at the start, you forgot to mention the best one - the three seashells

    • @airmann90
      @airmann90 11 หลายเดือนก่อน +2

      There really is no better way

    • @dieseldragon6756
      @dieseldragon6756 11 หลายเดือนก่อน

      We heard it a little differently in Britain, so it's common to find three *egg* shells in some peoples bathrooms over here... 🥚🚽🙃
      (It's probable they misheard the dialogue about the seashells...Or it might just be because ground-up eggshell is a good light abrasive and excellent for tackling limescale... 😇)

    • @paulevans9307
      @paulevans9307 11 หลายเดือนก่อน +2

      @@dieseldragon6756 Brit here. Never heard egg shells, only sea shells. It was the Pizza Hut dub.

    • @foogod4237
      @foogod4237 11 หลายเดือนก่อน +2

      (Psst! He doesn't know about the three seashells! _giggle_ )

    • @Ozspanman
      @Ozspanman 6 หลายเดือนก่อน

      Careful - you don't want to become just another "murder death kill" statistic. lol

  • @goatah
    @goatah 11 หลายเดือนก่อน +24

    Hey Mehdi! Thanks for another diy type video, I like them because you have a tendency to show a realistic experience.

  • @fazer_6
    @fazer_6 11 วันที่ผ่านมา

    Electrician here. A cut-in box is what you have. You cut the drywall so that everything passes through, but the top and bottom tabs. You then use f-clips to secure it to the drywall. With the stud there, you could have taken them off. You also need to ground the box. Everything you did was great though. It is safe, but not code or manufacturers inteanded purpose.

  • @TheCatAliasTNT2k
    @TheCatAliasTNT2k 11 หลายเดือนก่อน +6

    In Germany more or less all outlets have a common (sometimes split per floor) GFCI protection.
    And these GFCI "breakers" are installed at the same place as all other breakers, so you do not need to search the whole house.
    But be aware, that in older buildings, this might not be the case.

    • @LiquidPortalDigital
      @LiquidPortalDigital 11 หลายเดือนก่อน +1

      We have GFCI breakers as an option here in the US as well, they're becoming more common.

    • @CycleWerkz
      @CycleWerkz 9 หลายเดือนก่อน

      @@LiquidPortalDigital Almost all municipalities now require combo breakers for almost all circuits. These are both AFCI and GFCI, combination breakers. Exceptions are now for permanently wired devices such as ovens and cooktops. Strangely, Air Conditioner units are forced to comply. Soon all circuits will be required to have combo protectors

  • @questieee
    @questieee ปีที่แล้ว +41

    Mehdi installing an outlet to wash @ss 25 seconds ago... so educative

    • @Science-Vlog
      @Science-Vlog ปีที่แล้ว +2

      but its a video about butt

  • @geralduslepan5208
    @geralduslepan5208 11 หลายเดือนก่อน +2

    8:19 finally i found the best practical way to know if my breaker was off, thanks mehdi

  • @davidpanic
    @davidpanic ปีที่แล้ว +65

    Very nice! But good luck to anyone that ever tries to remove that cabinet in the future, you've now permanently bonded it to the wall 😂

    • @Science-Vlog
      @Science-Vlog ปีที่แล้ว +3

    • @Mentaculus42
      @Mentaculus42 ปีที่แล้ว

      @@Science-Vlog😵

    • @Hamzaanwar839
      @Hamzaanwar839 ปีที่แล้ว +2

      ​@@Science-Vlog😂😂

    • @davey2k12
      @davey2k12 ปีที่แล้ว +2

      That's if it ever gets removed
      It's only where he passed through the wood once doubt that be a problem for a saw 😂😂😂

  • @ujjc001
    @ujjc001 ปีที่แล้ว +14

    10:13 the struggle is real. I feel your pain...

    • @danek_hren
      @danek_hren 11 หลายเดือนก่อน +3

      Sisyphus's struggles

  • @andrevanderwesthuyzen5644
    @andrevanderwesthuyzen5644 11 หลายเดือนก่อน +19

    Great job!! Home DIY projects are always so fun to do. In my country it is illegal to have a plug outlet in the bathroom, even if it is GFCI protected. You truly inspire me! Have a nice day Mehdi :)

    • @maxgood42
      @maxgood42 11 หลายเดือนก่อน +8

      Just the whole room, may I ask what country ? usually there is a location issue like it must be a certain distance from the shower or taps ?

    • @Frizzy9000
      @Frizzy9000 11 หลายเดือนก่อน +2

      Yeah also curious here, can you wire *anything* in the bathroom? You said no plug outlet, is there another kind you can do?

    • @jeffspaulding9834
      @jeffspaulding9834 11 หลายเดือนก่อน +4

      ​@@maxgood42 ​ @Frizzy9000 Might be the UK. They're only allowed a "shaver receptacle" in bathrooms. No light switch except for a pull cord.

    • @maxgood42
      @maxgood42 11 หลายเดือนก่อน

      @@jeffspaulding9834 No hard switch ? well it makes sense being wet and all.

    • @Richard-dc5he
      @Richard-dc5he 10 หลายเดือนก่อน +1

      @@jeffspaulding9834 UK only permits safety ELV (12V, basically) that close to a toilet.
      You can have a 'shaver socket' a certain distance away from water, anything else must be even further away - thus outside the bathroom, unless you have a really large one.
      It's basically to ensure it's impracticable to drop a toaster in the sink or the bath.

  • @bwjclego
    @bwjclego ปีที่แล้ว +23

    Very impressive fishing abilities. From the cabinet to the existing box was fantastic!

  • @rhouser1280
    @rhouser1280 ปีที่แล้ว +43

    Sometimes getting it all to fit back in the outlet is the hardest part

    • @Mentaculus42
      @Mentaculus42 ปีที่แล้ว +4

      I will definitely agree with that! Sometimes you have to use the screws to push an overly stuffed box back together. Hate having to do that as it can cause wires to slip out of wire nuts. Many times I find wire nuts that are too small for the number of wires or someone added an extra wire to the outside of old bundle without first straightening the old bundle out first and re-twisting them together and then using the proper sized nut. Then you have to push this all back in without a wire slipping inside of the wire nut. Personally I always wrap some electrical tape around the insulation next to the wire bundle before applying the wire nut.

    • @theherk
      @theherk ปีที่แล้ว +2

      Especially with a lower gauge wiring. Lower than 12 can be a real pain.

    • @rhouser1280
      @rhouser1280 ปีที่แล้ว +2

      @@Mentaculus42 I work as an electrician in a power plant. People are against taping wire nuts, but I’m not. It’s an extra level of security to hold your wires together with the nut. & if the nut does come loose, at least you don’t have to worry about exposed conductors

    • @Mentaculus42
      @Mentaculus42 ปีที่แล้ว

      @@rhouser1280
      That is interesting, why are they against, is it because it might be harder to tell if there is arcking or less cooling. I didn’t explicitly say that I first put some tape to hold the bundle even, twist on the nut and then apply more tape to hold the nut from loosing up during the “pushing everything back in” phase. I have pulled boxes apart that are old and sometimes the wire nuts can be uncomfortably loose. Maybe I am just too paranoid, but the more I see of other people’s work that was not done at least half-@ʴsed , the more I shake my head and think bad words.

    • @THE-X-Force
      @THE-X-Force ปีที่แล้ว +3

      @@rhouser1280 Why would anyone be against taping wire nuts?

  • @davidh.4649
    @davidh.4649 11 หลายเดือนก่อน +3

    I had to do the same in my bathroom. I just went ahead and cut small holes in my sheetrock, making sure to keep the pieces I cut out and not let them fall into the wall. That way the wiring is in the walls and I was able to use regular romex. Sheetrock repair is pretty easy to do The way you did it, if someone ever decides to change out the bathroom cabinet they are really going to curse you for running the wire through the cabinet. 😁

  • @JMjayesim
    @JMjayesim ปีที่แล้ว +16

    Putting the light bulb where he poops. I guess thats what you call a butt lamp 13:47

  • @cubanes
    @cubanes ปีที่แล้ว +62

    As always. Entertaining and informative. Love watching these videos!

  • @lip897
    @lip897 10 หลายเดือนก่อน +1

    I'm an german electrician and these american outlets and how the wires are connected just scars me. German outets and the whole connections of the wires is so much safer.
    I don't understand why your cable has a metal sheathing. In Germany it's just PVC and even the tubes lying in concreat and behind plaster are made out of some sort of plastic.
    But I really like your videos so keep it up :)

  • @HugforYou
    @HugforYou ปีที่แล้ว +8

    14:05 I agree with you Mehdi! Thx 👋☺

  • @dallynsr
    @dallynsr ปีที่แล้ว +8

    Hay, I do electrical, and would’ve probably used yellow romex even, but it would’ve turned out the same with the path being hidden behind the wall and in the cabinet. The MC flex is a nice upgrade to romex.
    Is also a good little sit-thru for anyone not understanding what post-construction electrical is like.
    Great job Mehdi.
    TMI on the need for the Bidet though.
    Some Americans just want to fight over TP when it’s out, that’s all, they’ll never learn.

    • @lukeanderson439
      @lukeanderson439 11 หลายเดือนก่อน +3

      "where exposed to damage" or something iirc. Behind the drawers should qualify as protected. You aren't doing things behind there 99.9% of forever. NM would probably suffice!

    • @manletopia4801
      @manletopia4801 11 หลายเดือนก่อน

      ​@@lukeanderson439 UF romex

  • @Avidiy
    @Avidiy 11 หลายเดือนก่อน +2

    Make something for 6 million subscribers, very good job on the wiring, but remember you used those red pieces on your heater installation video upgrade video? O think you should use those here, you could run wire of the toilet seat by just extending its wire and then plugging it in, anyway good installation.

  • @LegoTechnicsRule
    @LegoTechnicsRule 11 หลายเดือนก่อน +12

    10:35 As an electrical apprentice who has placed thousands of straps, I feel your pain.

  • @Ariccio123
    @Ariccio123 ปีที่แล้ว +20

    4:38 mehdi lemme blow your mind - now there are GFCI receptacles on the market that have AUDIBLE ALARMS! I've been in the process of putting them at the head of every branch circuit lately, they're amazing, and also super useful for any non-technical people who may be in your home!

    • @3nertia
      @3nertia 11 หลายเดือนก่อน

      What value does that really add though?

    • @ematt622
      @ematt622 11 หลายเดือนก่อน +3

      ​@@3nertianotifies you when it trips. It's helpful if you have a sump pump, radon system, deep freeze, etc on a GFCI protected circuit in a basement or garage, for instance.

    • @Ariccio123
      @Ariccio123 11 หลายเดือนก่อน

      @@ematt622 not *just* that either. It's common for people to have no clue what is wired downstream of a GFCI. A neighbor had several outlets that hadn't worked in years and had no idea why... Turns out that a GFCI in a half bathroom used as a closet was in the tripped state, and it fed outlets all the way across the house

    • @3nertia
      @3nertia 11 หลายเดือนก่อน +1

      @@ematt622 I s'pose that's a fair point - I'm stuck in an apartment, without a vehicle or a job so it hadn't occurred to me heh

    • @Ariccio123
      @Ariccio123 9 หลายเดือนก่อน

      @@3nertia apartments sometimes have really questionable wiring! When I was little I had weird issues with gfcis in my apartment, and had no idea what the deal was other than something was tripped somewhere! An alarm makes it obvious.

  • @colinstu
    @colinstu 11 หลายเดือนก่อน +13

    Can't use AC/MC with plastic boxes like that. You could mount a junction box in the cabinet that takes the MC, and NM-B from the back-side that feeds up wall and into plastic box properly. Also those are the wrong size one-hole straps, need 3/8" MC straps. 13:05 you bought the right box, but yeah hole a lil too big, but what you need to use there are two "madison straps", which are flat metal straps that you insert and then bend, which then rigidly holds the old-work-box in place against the drywall. no need for screws or extra ears.

    • @sirenfan97
      @sirenfan97 5 หลายเดือนก่อน +2

      Your supposed to use 12/2 in bathrooms too

  • @davidwilliams-qu7cm
    @davidwilliams-qu7cm 11 หลายเดือนก่อน +4

    Not an electrician but from UK and it amazes me that the modules have the power feeds exposed. Makes me appreciate our sockets and wiring a bit more feels safer.

    • @Pow3rus
      @Pow3rus 11 หลายเดือนก่อน +3

      Watching this from france and oh man these breakers/gfci/outlets and those weird things to tie wires together really look medieval to me.
      Looks like things you could find in a french house from 1980 or 1990 max.

    • @eDoc2020
      @eDoc2020 11 หลายเดือนก่อน +1

      Your sockets are better than our outlets but in terms of wiring: do you know what a "ring main" is?

    • @mernokimuvek
      @mernokimuvek 8 หลายเดือนก่อน

      Safety is for the cowards.

  • @Lierofox
    @Lierofox ปีที่แล้ว +4

    8:23 Duplex receptacle, or outlet. "Plug" is for the cord side.

  • @terrance_huang
    @terrance_huang 11 หลายเดือนก่อน

    11:01 you can just use the outlet as a jumper, it has 2 terminals each side.

  • @davidwatson7604
    @davidwatson7604 ปีที่แล้ว +9

    Really enjoy your work here, glad you're not afraid to get lit up. Lotta fun, thanks.

  • @HardwareScience
    @HardwareScience ปีที่แล้ว +5

    13:26 do you even need to tie the earth wire to the box? IIRC, unless it’s an isolated ground receptacle, the green screw is shorted to the metal box

    • @EvilCarrot
      @EvilCarrot ปีที่แล้ว

      Well you probably wouldn't need it, it's just for more safety. As always when grounding things.

    • @markc2643
      @markc2643 ปีที่แล้ว

      Some outlets are rated for grounding that way, others aren't.

  • @Patytay
    @Patytay 11 หลายเดือนก่อน +7

    This guy makes you laugh but he also makes you learn. It's really fun to watch his educational videos while also having lots of laughs.

    • @cdo7881
      @cdo7881 10 หลายเดือนก่อน +1

      fax

  • @TheHellis
    @TheHellis 11 หลายเดือนก่อน +7

    8:05 the breaker tried to save you multiple times, you just ignored it and reset it every time :-)

  • @EHCVisp100
    @EHCVisp100 ปีที่แล้ว +15

    You could have daisy chained the outlet by the sink. Would have saved you the effort to use the wire nuts. Regardless either way is to code

  • @milosozegovic6980
    @milosozegovic6980 9 หลายเดือนก่อน

    In Europe we use RCBs, in my country we also call them FID (don't know what it stands for and is it in english anyway) instead of GFCI, and it can protect your whole house if you want to. I put mine in front of all circuits so all outlets and machines, water heaters and so on are protected.

  • @AliFareedMC
    @AliFareedMC ปีที่แล้ว +17

    0:46 Japan is a butt haven - ElectroBOOM 2023 😂😂😂😂😂

  • @hyprodAx_
    @hyprodAx_ ปีที่แล้ว +10

    7:10 you have to buy an endoscope camera.

  • @Sam3532
    @Sam3532 11 หลายเดือนก่อน +2

    8:16 Yes check the breaker is switched off by grabbing the live terminals… brilliant idea! 😂 this was quite the ‘how NOT to do diy’ video lol, & a good alternative to stabbing a piece of wire blindly into the hole is an endoscope, they are so cheap nowadays, a really useful bit of kit to have in the tool bag

    • @Sam3532
      @Sam3532 11 หลายเดือนก่อน

      Oh & I thought American plug sockets where shit now I’ve sent he insides they are shit & deadly! Who thought putting the live terminals precisely where you naturally grab it from was a good idea……?

  • @nicolaslanglais
    @nicolaslanglais ปีที่แล้ว +15

    5:48 is that purple thing what I think it is?

    • @himankanborkakati8731
      @himankanborkakati8731 11 หลายเดือนก่อน +4

      Maximus dildoleus? 😮

    • @pixiesinc743
      @pixiesinc743 11 หลายเดือนก่อน +1

      To clean the toilet when get dirty by "resiudes"

    • @pixiesinc743
      @pixiesinc743 11 หลายเดือนก่อน

      ​@@himankanborkakati8731Everything's a dildo if you're brave enough too

  • @Zeddify
    @Zeddify ปีที่แล้ว +18

    3:32 had me dying

  • @WrathOfDragon.
    @WrathOfDragon. 8 หลายเดือนก่อน

    the "fun" phrases old electricians say to remember where each wire goes are "It's like the Olympics, black always gets the gold," and "Electrical work is BS"
    Black on gold as well as Black on smooth wire.
    also if you attach a ground to the outlet, it grounds the metal attaching bracket which will in turn ground your box. This is why if you have a properly grounded outlet you can touch the screw on it to ground yourself.
    EDIT: fix quotes

  • @tengelgeer
    @tengelgeer ปีที่แล้ว +8

    11:37 Wait, the light switch is still active.... Are you allowed to have feeds from two breaks into the same box?

    • @Owen_loves_Butters
      @Owen_loves_Butters 11 หลายเดือนก่อน +1

      Yes, that's completely fine.

    • @wigglesfourthree3390
      @wigglesfourthree3390 11 หลายเดือนก่อน

      When I ran wires for 120/240 residential in California over a decade ago, it was allowed. My mentor/boss did advise that you try to keep the two live line on the same leg so as not to accidentally get 240V in a box meant for 120.

    • @tengelgeer
      @tengelgeer 11 หลายเดือนก่อน

      @@wigglesfourthree3390 Reason why it's not allowed here is two fold. One, expectation, you should always be able to disconnect a complete branch / appliance with a single action. And two, if two wires from the same leg that are fused for their rating touch or get connected by somebody who doesn't pay attention you're now able to draw to much current because the breakers are now in parallel.

  • @Ariccio123
    @Ariccio123 ปีที่แล้ว +7

    11:28 mehdiiiiiii you may be electroboom but you're still an engineer! Use a torque screwdriver!!

    • @dogs-and-destruction-channel
      @dogs-and-destruction-channel ปีที่แล้ว

      To harsh for these style screws. Besides that's how you build up muscle strength my friend 💪.

  • @talbrys
    @talbrys 11 หลายเดือนก่อน +1

    Man, he makes the sponsor advertisement amusing enough I want to watch it through, that's skill

  • @danwhite3224
    @danwhite3224 ปีที่แล้ว +20

    7:56 Why on earth are those sockets designed like that? Who thought that having the L and N on either side, _exposed_ ,would be a good idea?

    • @Sassi7997
      @Sassi7997 ปีที่แล้ว +2

      Especially as metal boxes are quite common in North America.

    • @Mentaculus42
      @Mentaculus42 ปีที่แล้ว +1

      There was a time when legal sockets allowed you to insert the end of the stripped wire which in theory could have dealt with this issue, but they caused other safety issues, so back to exposed screws. Personally I always wrap some electrical tape around the exposed screws to deal with this and other issues.

    • @snakeinthegrass7443
      @snakeinthegrass7443 ปีที่แล้ว

      Most likely it was Thomas Edison. He had over 1000 patents on all sorts of electrical components. Many electrical things here in the US are still somewhat similar to when they were invented. I can install a brand new switch or receptacle in a box that's almost 100 years old and the screw holes are the same distance apart and use the exact same screws to install.

    • @Owen_loves_Butters
      @Owen_loves_Butters 9 หลายเดือนก่อน

      The North American outlets are just awful in every way.

    • @mr.s7576
      @mr.s7576 9 หลายเดือนก่อน

      You win the power outlet

  • @senorstrong
    @senorstrong ปีที่แล้ว +5

    as a professional dumbass myself, I think you did a great job. having the space behind the walls to do stuff like this makes me envious (I live in a country with mortar and brick homes, so no drywall for us)

  • @AlwaysAnts
    @AlwaysAnts 11 หลายเดือนก่อน

    Fun video, thank you. Coming from an outdoorsy person, may I ask your suggestion for going outdoors where there is no water? You should never wash off poop into a creek or other waterway. Frankly, as adults here, let's all agree that wiping or bidet is a personal choice, and, it is an unfortunate fact that if you're "smearing" feces around when you wipe, you aren't wiping correctly. Lastly, would you shake hands with someone who got poop on their hands and merely sprayed water on them to "clean" them?
    My outdoors go-to is mullein leaves for wiping, as they are antimicrobial and softer than TP. And being a common weed you can harvest all you want without hurting nature. Thanks for the vid, looking forward to the bidet install!

  • @AndrewTheRocketCityRailfan4014
    @AndrewTheRocketCityRailfan4014 ปีที่แล้ว +33

    He’s an electrical engineer, that’s why he was able to pull it off alive

    • @jonc4403
      @jonc4403 ปีที่แล้ว +4

      I put in outlets when I was a 10 year old kid. Anybody can do it.

    • @VeeTHis
      @VeeTHis 11 หลายเดือนก่อน +4

      @@jonc4403 Uh... I wouldn't say "anyone" can do it. If I tried putting in an outlet I wouldn't even know where to _start_ . Even if I did I'd probably set my house on fire from improper wiring lmao

    • @3nertia
      @3nertia 11 หลายเดือนก่อน +2

      @@VeeTHis With acquiring the necessary information, of course! You start by looking up electrical codes in your municipality. Then you identify which circuit breaker controls the circuit you need to work on. Turn that breaker off. Solve each problem along the way until you have an outlet installed according to the codes you researched :)
      Anyone really can do this, it's not quantum mechanics ;)

  • @markc2643
    @markc2643 11 หลายเดือนก่อน +5

    I've got that same DigiKey ruler at 11:59 It's awesome.

  • @8546Ken
    @8546Ken 9 หลายเดือนก่อน

    I've been advised that steel armored cable (sometimes called "BX") is not allowed by our local building codes because of the risk of nicking the wires. The code does allow flexible steel conduit (Greenfield), so that's what I use. When installed, it looks the same as BX. (I'm an electrical engineer and installing a bathroom receptacle for an electric toothbrush.)

  • @electrifyingvids3545
    @electrifyingvids3545 ปีที่แล้ว +13

    Next time use wago connectors! GreatScott would agree too.

  • @GeorgeCarlin88
    @GeorgeCarlin88 ปีที่แล้ว +14

    9:25
    that's what she said.

  • @foogod4237
    @foogod4237 11 หลายเดือนก่อน

    For a DIY project, this was really pretty good, IMHO.
    It is kinda confusing because people use the different terms wrong all the time, but:
    "outlet" = one set of holes (and contacts, etc) used for plugging in one power cord.
    "receptacle" = the whole unit (usually with two outlets) which you install into the box and connect to the wiring.
    Oh, and you really don't need armored cable for that application (at least in the US). You could just use NMC cable (AKA "exterior grade" Romex). You can't use regular NM (Romex) cable, because a bathroom is a damp/wet location, but NMC cable (typically gray, and rated for use in wet, outdoor, or corrosive locations) should be fine as long as it's secured up inside cabinets and such (i.e. protected from potential damage). Of course the armored cable is also fine, just more of a pain to work with...
    Those wire nuts are also not really twisted enough, BTW. I highly recommend DIYers use something like the Wago 221 "lever nut" connectors instead of wire nuts, because it's much easier to make sure you're actually using them correctly. Wire nuts are very easy to do wrong, which can be bad. (also, the Wagos are smaller, so they're easier to fit back in the box, too)

  • @kouroshkabir77
    @kouroshkabir77 ปีที่แล้ว +8

    Being able to record with one hand and do that wiring in those tight places with other, is an art. Kudos Mehdi

  • @beanapprentice1687
    @beanapprentice1687 ปีที่แล้ว +16

    3:39 umm, Mehdi… how can you be sure that DeleteMe isn’t just stealing your personal information too?

    • @Clearwater420
      @Clearwater420 ปีที่แล้ว +1

      Technically intel processor sense at least 2008 have had back door processor at hardware level, inless you buy your own wafers, then at least intel and would not be surprised if industry standard by now ..... *Intel Management Engine* it has access to all raw information from processor level ..... even VPN are technically useless...

    • @harriska
      @harriska ปีที่แล้ว

      ​@@Clearwater420completely unrelated

    • @Nsodnoajdjksl
      @Nsodnoajdjksl 11 หลายเดือนก่อน

      ​@@Clearwater420not ExpressVPN.

  • @robertb6276
    @robertb6276 11 หลายเดือนก่อน +1

    Its like watching a video of myself doing a home improvement project except with more ElectroBOOM.

  • @someoneelse1904
    @someoneelse1904 ปีที่แล้ว +5

    After spending quite a bit of time in Indonesia I ended up installing a shataf at home in the UK. Love it 😁

  • @frankowalker4662
    @frankowalker4662 ปีที่แล้ว +31

    The power outlet here in the UK is either referred to as a socket or simply 'the mains'. As in 'Plug it into the mains'. 👍

    • @GojosBackHand
      @GojosBackHand ปีที่แล้ว +1

      That sounded so corny😂

    • @GTLugo
      @GTLugo ปีที่แล้ว +3

      Well, "the mains" usually just means the power wires, not the receptacle itself. Over here in the east coast of the US, I usually also hear it called a "power socket" or "wall socket."

    • @leopichler
      @leopichler ปีที่แล้ว +1

      mostly a south/south east thing to say imo! others say socket, or just plug it in. never outlet, and if you’re really posh you might say receptacle

    • @viscousman
      @viscousman ปีที่แล้ว +1

      Same here in India too

    • @fromthegamethrone
      @fromthegamethrone ปีที่แล้ว +3

      I disagree, the mains is the source of the power. For example, if I had a "plug" or "socket" coming directly from the national grid, and one coming from a power generator, I'd say plug it in to the mains.

  • @DerpyLaron
    @DerpyLaron 11 หลายเดือนก่อน +9

    7:41 Well your aren't supposed to hold the camera. That's what tripods or kids are for

    • @BenGameBG
      @BenGameBG 7 หลายเดือนก่อน +1

      7:34

  • @Roman-Pregolin
    @Roman-Pregolin ปีที่แล้ว +4

    "Push it in and hope for the best" - words to live by

  • @aliensmile22
    @aliensmile22 11 หลายเดือนก่อน +3

    Look at that, no plastic wrap, wire cut offs, or any mess for someone else to clean. Sparkys oughta learn from this. Great video Mehdi.

  • @electrokid4885
    @electrokid4885 ปีที่แล้ว +32

    Mehdi you are my all time favorite TH-camr and you have taught me so much! ❤

  • @X4Alpha4X
    @X4Alpha4X 11 หลายเดือนก่อน +7

    you didnt need to wire nut a 3rd length of wire to connect to the first outlet. if you notice, there are two screws on each side of the outlet. these are intended to be used for live pass throughs like what you just did. so you'd for example tie the incoming hot to the bottom, and the hot outgoing to the top screw, same on neutral.

    • @lukeanderson439
      @lukeanderson439 11 หลายเดือนก่อน +2

      You aren't wrong about the device being able to do that. However, best practice is to pig tail from the wire nut. This way, the device isn't carrying the full load of all downstream devices and you can remove that device simply without compromising anything else.