LV panel testing procedure in new 2017/lv switchgear testing/lv switchgear panel

แชร์
ฝัง
  • เผยแพร่เมื่อ 2 ธ.ค. 2024

ความคิดเห็น • 54

  • @dthangel4
    @dthangel4 6 ปีที่แล้ว +1

    the irony of this video is that i know in which switchgear this test was carried out as i was the first one to use the exact same hioki 5kV Insulation tester. and i never tested sub main distribution boards with lower power rating with insulation voltage of 1000VDC but only 500VDC. this machine only came in to use when some consultants demanded to see the megger value readings, as normal hioki megger would never show any reading above 4000Mohms, only infinity or pass sign. anyway nice to see someone post knowledgeable things so that others can learn. keep up the good work.

  • @vkk3292
    @vkk3292 ปีที่แล้ว +1

    thanks..
    Please tell the rate of voltage to be applied for different rate of switch gear.

  • @vibeelectricals9471
    @vibeelectricals9471 5 ปีที่แล้ว +2

    what will be the connection diagram when we want to apply high voltage between all the three phases short and earth?

  • @தமிழ்-ம1ந
    @தமிழ்-ம1ந ปีที่แล้ว

    Hi voltage test is a pressure test
    in this test you will get a leakage current in micro amps not in mega ohm.

  • @zulfiquarali6205
    @zulfiquarali6205 6 ปีที่แล้ว +1

    please give video or video link for routine test for lv panel in a factory.

  • @anandhaperumal7822
    @anandhaperumal7822 2 ปีที่แล้ว

    Why high voltage test required in lv panel?

  • @jagrutijadhav5720
    @jagrutijadhav5720 4 ปีที่แล้ว

    Why we want to short the c.t before testing . And how to short

  • @SaurabhSingh2
    @SaurabhSingh2 4 ปีที่แล้ว

    I need to connect LV and MV cable in respective spare feeder but client is ask to perform full panel test. Kindly help me, in preparing minimum list of test I need to perform for LV and MV cubicle

  • @tungnguyenquang1804
    @tungnguyenquang1804 2 ปีที่แล้ว

    The video sound is pretty good, beyond my imagination

  • @karthickjl9453
    @karthickjl9453 7 ปีที่แล้ว +1

    For 4 run 240 sq.mm xple armoured cable 1000v 513meter for insulation resistance testing what value should come using Megger

    • @NaveedKhan-hy2uz
      @NaveedKhan-hy2uz 7 ปีที่แล้ว

      Karthick siva Hi Siva, Insulation Resistance greater than 200Mohms is better insulation resistance if u obtain in Gigaohm or Teraohm would be great insulation resistance...hope i have answered ur question

  • @vijayganesh4489
    @vijayganesh4489 3 ปีที่แล้ว

    How to short the CT in LV panel and what's the reason sir.

  • @ayarottilsandeep545
    @ayarottilsandeep545 3 ปีที่แล้ว

    What is the testing voltage for LV cable (for IR test)? Is it 500volts or 1000 Volts or any other

  • @REKAPALLIVDNRao
    @REKAPALLIVDNRao 7 ปีที่แล้ว +1

    What is the good resistance value of Insulation resistance ?

  • @Shansamad
    @Shansamad ปีที่แล้ว

    Very Good information ❤

  • @br.ampethkarmari2283
    @br.ampethkarmari2283 7 ปีที่แล้ว

    Sir.your video s my doubt clarified. very use full video s any way how to mltp inter locking in mltp lv panels.

  • @syedsheik8780
    @syedsheik8780 ปีที่แล้ว

    Please explain FAT and SAT test

  • @irfanhussain9282
    @irfanhussain9282 3 ปีที่แล้ว

    HOW WILL YOU GET RESULT IN OHMS FOR HIGH VOLTAGE TEST? DURING HIPOT YOU WILL GET RESULT IN MICRO OHMS

  • @sudipmaurh6710
    @sudipmaurh6710 4 ปีที่แล้ว

    Kindly discuss briefly with audio & visual

  • @vijaymani6476
    @vijaymani6476 7 ปีที่แล้ว

    bro explani to how many range ohms resistance using in earthing for sub station and home& industrys

  • @NaveedKhan-hy2uz
    @NaveedKhan-hy2uz 7 ปีที่แล้ว

    Thanks bro u r videos are of great help

  • @shekahamedshadhik1592
    @shekahamedshadhik1592 3 ปีที่แล้ว

    3:33 Tera Ohms not Tiga Ohms

  • @kalaiveera20
    @kalaiveera20 5 ปีที่แล้ว

    Nice bro how to short CT. How to make live voltage test I need video.

  • @irshathahmed4782
    @irshathahmed4782 7 ปีที่แล้ว

    G Hi I need to explain phase to phase RY YB BR two phase part of the voltage going

  • @asif57154
    @asif57154 7 ปีที่แล้ว

    Bro why we need to short ct terminals before hv test . Must reply please

    • @Edisonworld
      @Edisonworld  7 ปีที่แล้ว +3

      preventing demages of measuring meter s in LV panel s because of messuring meters insulation voltage is low that why we remove meters and shorting ct terminal....

    • @irshathahmed4782
      @irshathahmed4782 7 ปีที่แล้ว

      what is mean of CT

    • @irshathahmed4782
      @irshathahmed4782 7 ปีที่แล้ว

      G I had to phase to phase RY 410v same YB BR voltage it is good results

    • @irshathahmed4782
      @irshathahmed4782 7 ปีที่แล้ว

      than. How to check the phase to earth on digital clamp meters

  • @deepakkumarraja6538
    @deepakkumarraja6538 7 ปีที่แล้ว

    Kinldy do the explain about ATS & ACB of LV Panel testing procedure also

  • @tariquemallick4612
    @tariquemallick4612 2 ปีที่แล้ว

    Thanks bro ✔️

  • @ggm420
    @ggm420 2 ปีที่แล้ว

    your Camera is not working at all

  • @mdsobujkh
    @mdsobujkh ปีที่แล้ว

    Thanks

  • @mostpowerfullsayri8888
    @mostpowerfullsayri8888 6 ปีที่แล้ว

    Hv test not clear

  • @alirezajafari84
    @alirezajafari84 ปีที่แล้ว

    🎉ok

  • @ashrafhossain9332
    @ashrafhossain9332 6 ปีที่แล้ว

    good

    • @Edisonworld
      @Edisonworld  6 ปีที่แล้ว

      tanks for your support

  • @rukminigouda3203
    @rukminigouda3203 2 ปีที่แล้ว

    「画像が不快すぎる」、

  • @伏云刚伏
    @伏云刚伏 2 ปีที่แล้ว

    Bunyi video tidak bagus

  • @raviarya1738
    @raviarya1738 7 ปีที่แล้ว

    Hindi me banar

  • @mopkabhatapara8614
    @mopkabhatapara8614 6 ปีที่แล้ว

    hindi me bolakarona please

    • @austanraj761
      @austanraj761 5 ปีที่แล้ว +1

      You useless guy..Learn International language..Idiot..As a Engineer you should know English

    • @prabhakaran20ten
      @prabhakaran20ten 4 ปีที่แล้ว

      @@austanraj761 damn true brother 😂👌