MULTIPLE YORK PACKAGE UNIT'S NOT COOLING

แชร์
ฝัง
  • เผยแพร่เมื่อ 24 ธ.ค. 2024

ความคิดเห็น • 164

  • @Ghyus01
    @Ghyus01 8 หลายเดือนก่อน +88

    "no wonder that one's missing, it's in my hand. Duh"
    Holy moly I feel that one 😂

    • @TheAncientOneYT
      @TheAncientOneYT 3 หลายเดือนก่อน +1

      That's not as bad as me searching around for a hat that is on my head. :(

  • @alext424
    @alext424 8 หลายเดือนก่อน +77

    Those units have definitely lived their life, and they’re still working decently well considering how old they are. They sure don’t build things of the same quality that they once did. Thank you for another awesome video Chris! I’m learning more and more from you with every new video I watch. Keep up the great work! 👍🏻👍🏻👍🏻

    • @dotcom624
      @dotcom624 8 หลายเดือนก่อน +10

      Maybe I wasn’t paying attention, but I don’t remember hearing about PMs by this company on these units. From the looks of it, they must do at least some PM to keep old units working as well as they do. Might not be as efficient, but as others have mentioned, they don’t make them like they used to! Know what I mean, Vern?

    • @HVACRVIDEOS
      @HVACRVIDEOS  8 หลายเดือนก่อน +4

      @@dotcom624 I know exactly what you mean

    • @jerrykorman7770
      @jerrykorman7770 3 หลายเดือนก่อน +1

      @@HVACRVIDEOScombine the garbage QC of new units with zero PM. What could possibly go wrong?

    • @Walczyk
      @Walczyk 23 วันที่ผ่านมา

      @@jerrykorman7770pm?

  • @pigalex
    @pigalex 8 หลายเดือนก่อน +27

    you know, sometimes the engineer part of my brain thinks i could make an absolutely ballin refridgeration unit and then i see these absolute tanks that are still happily running and i get humbled. great work as always!

    • @HVACRVIDEOS
      @HVACRVIDEOS  8 หลายเดือนก่อน +2

      Thanks

  • @jasonjohnsonHVAC
    @jasonjohnsonHVAC 8 หลายเดือนก่อน +14

    Those units absolutely suck to replace the heat exchanger...if you haven't replaced one...count yourself lucky. They are simple units in form and function...probably why it's lasted so long.
    Very nicely done as always Chris.

    • @johnhaller5851
      @johnhaller5851 8 หลายเดือนก่อน +1

      He said at the end that most of the units have had the heat exchanger replaced and that it was a nightmare to get all the parts.

    • @TheGhettoLobster
      @TheGhettoLobster 8 หลายเดือนก่อน +1

      As someone who deals with mostly York in their area, yes, these sunline yorks suck BALLS to replace the heat exchanger.

  • @ATedu
    @ATedu 4 หลายเดือนก่อน +2

    I am not in HVAC - I will never be. However, I sure do love your videos. I really enjoy watching and learning from experts, people how have a passion for what they do. I appreciate your drive for customer service, running a business and teaching everyone. Excellent work.

  • @shelvins1841
    @shelvins1841 8 หลายเดือนก่อน +6

    Was hoping I'd see one of these units in one of your videos. I have 2 of them on my building and it was built in the late 80s so I'm pretty sure they're original since we've been here since 94 and we've never replaced them. One of them finally needs to be replaced but the other unit works like a champ. I have a Rheem and Trane on another building, those are about 10 years old and have needed more work this this unit has since 94.

  • @squirrelwood8008
    @squirrelwood8008 8 หลายเดือนก่อน +50

    This old piece of junk is still working better than the new pieces of junk one third of its age...

    • @Extremely_crazy_toaster_light
      @Extremely_crazy_toaster_light 8 หลายเดือนก่อน +1

      i had a old Philips 55 inch tv it could survive a fast plushie to the screen no matter what!

  • @Transit_Biker
    @Transit_Biker 3 หลายเดือนก่อน +1

    Loving the new intro! Cannot believe how trashed those condensers are. Surprising that these units have not just fallen apart from age.

  • @almosteverythingapple
    @almosteverythingapple 2 หลายเดือนก่อน +2

    Dang. The early 90’s in California. And u thought my 2005 mini split was impressive.

  • @HappilyHomicidalHooligan
    @HappilyHomicidalHooligan 8 หลายเดือนก่อน +12

    Welcome to Ontario Weather...
    Here you need a T-Shirt, Fall Jacket, Snowsuit and Umbrella all in the same day...
    We have a saying: If you don't like the Weather...Wait 5 minutes...
    😄😁😆😅😂🤣

  • @altzan2602
    @altzan2602 8 หลายเดือนก่อน +16

    Calling that unit old is an understatement, it is very rusted. Suggesting it was either a cheaper model, or perhaps 80s. Either way, I'm unsure. However, I agree with the rest of the comments, this thing has lived its life and done well.

    • @HappilyHomicidalHooligan
      @HappilyHomicidalHooligan 8 หลายเดือนก่อน +1

      He said at the beginning it's from the 90's...
      So it's 30+ years old and still working...sort of...

    • @arcticarrowhvacr
      @arcticarrowhvacr 8 หลายเดือนก่อน +3

      Bristol compressors with metal tags instead of stickers. 1994 at the latest.

  • @tyhuffman5447
    @tyhuffman5447 8 หลายเดือนก่อน +11

    Lock tight is great for vibration issues. Things don't tend to vibrate off when they are secured with Lock tight.

  • @HappilyHomicidalHooligan
    @HappilyHomicidalHooligan 8 หลายเดือนก่อน +5

    If you can't get any Electrical Conduit that will fit the space, try a piece of PEX water pipe...the 1/2" PEX pipe is big enough to take a single length of 14/2 ROMEX house wire so the individual wires for one of your Fan Motors will fit with room to spare with little to no chance of overheating the wires...that will keep the wires away from the blades as well as protect them from rubbing out on the fan grill...

  • @kens.3729
    @kens.3729 8 หลายเดือนก่อน +6

    Preventative Maintenance is always Money well spent but those Paying your Bill don’t look at it the same way. Keep up the Strong 💪 Efforts servicing customers.👍

  • @ericdee1310
    @ericdee1310 8 หลายเดือนก่อน +3

    Boy, this brings back memories... The McDonald's I was a maintenance man at had these York units & every week I'd pull & clean the air filters (They had the type of air filters that were washable -- Just spray 'em down with degreasing solution, rinse 'em out, let 'em dry then put them back in) and clean the condenser coils. Every year we did PM on them where we'd take 'em apart, clean them out thoroughly & put them back together. If anything malfunctioned, we called in a local HVACR tech to fix it.

  • @timtrail1845
    @timtrail1845 8 หลายเดือนก่อน +2

    I have 3 Yorks units on a building I work at . Plus I keep the fully cleaned, oiled, belts , coils cleaned, I also buy new replacement parts . I also listen to the units for any problems. I love your TH-cam channel I learned many things, on the different units you repair, Thanks

  • @AARONJL92
    @AARONJL92 8 หลายเดือนก่อน +3

    Am I wrong or did you start a more step by step process approach on your videos. I'm loving it!

  • @feddersairdude
    @feddersairdude 8 หลายเดือนก่อน +1

    When using generic fan motors I like to use a piece of 3/4 pvc to run the wires through if there is no existing conduit. I normally fasten the pvc to the guard with zip ties, but even when those break off the pvc holds itself in place.
    Those plastic insulators around the reversing wire terminals have a habit of cracking off in the sun and shorting out, especially on roofs with no tree cover.

  • @TechOne7671
    @TechOne7671 8 หลายเดือนก่อน +2

    Good video Chris. Most customers are usually happy with JUST getting it fixed. Like an old car, as long as it starts and runs, they don’t care about economy, emissions or whether it has satnav, as long as it gets them from a to b. Them old units still blowing cold ish air? Jobs a good one. All the best.

  • @fellpower
    @fellpower 3 หลายเดือนก่อน +1

    You have crazy electrical installations in the us. as a german electrical engineer, i only can shake my head....but it works - no more money for that old ladies, because they work...

  • @Goldstacker1972-kp2bh
    @Goldstacker1972-kp2bh 8 หลายเดือนก่อน +2

    I use electrical conduit to protect the wires then zip tie it to the shroud.

  • @markchwala
    @markchwala 7 หลายเดือนก่อน +2

    York made good units and they seem to have stood the test of time. I think Ford used York compressors in their cars many years ago and I heard they could be rebuilt.

  • @Colt-wr6wx
    @Colt-wr6wx 8 หลายเดือนก่อน +1

    Yeah this time of year is tricky.. need an extra chiller during the day here.

  • @stephenmcconnell4302
    @stephenmcconnell4302 5 หลายเดือนก่อน +1

    I have actually gotten a condenser unit before and from the factory fan was wired incorrectly on a single phase unit 😮

  • @alvinstaines4305
    @alvinstaines4305 6 หลายเดือนก่อน +1

    A trick i do to remove really stuck fan blades off bad motors is cut the shaft and drill out the shaft, never couldn't get one off doing that hardest part is drilling the hole dead center of the shaft.

  • @andydaley1372
    @andydaley1372 8 หลายเดือนก่อน +2

    Another awesome video man! Thank you for sharing!

  • @iyaayas200
    @iyaayas200 8 หลายเดือนก่อน +2

    how is the condensor fan motor suppose to run with no cap hooked up?

  • @Hopefullymarried
    @Hopefullymarried 5 หลายเดือนก่อน

    I’ve worked on one of these before for PM work and on my last visit, on the blower wheel shaft, i spied grease zerts🧐. Never saw them before or was shown it has them.. just a quick eye out for the next one you come across

  • @peterszczepaniak1893
    @peterszczepaniak1893 8 หลายเดือนก่อน +4

    Those older units really out live the new units. Some the new units come flat or don’t even last a year before something major happens.

  • @warmtepompdokter
    @warmtepompdokter 8 หลายเดือนก่อน +2

    Y1 Wy isn't it cooling 👌 great words 👏

  • @karizmatic5
    @karizmatic5 8 หลายเดือนก่อน +1

    Just putting this out there for anyone starting in the business... Just because you turn off the disconnect switch DOES NOT MEAN you don't have power going to the unit. In my very green days, I turned off the disconnect thinking I was safe to work on the unit, but heard my schooling in my ear about "always check for power". I checked inside the unit just before I put my hands in there and had 460v. This was because the monkeys that were there before me straight bypassed the disconnect inside the disconnect switch. To say I was upset doesn't come near what I was feeling in that moment. Always check for power.

  • @dashcamandy2242
    @dashcamandy2242 8 หลายเดือนก่อน +6

    I agree with you, those old Yorks aren't going to last too many more California summers. You bought them some time, but replacement is inevitable.
    Full refurbishment, when factoring in parts and labor (assuming you can find all the parts) would probably be close to replacement cost. The phrase "diminishing returns" once again rears its ugly head...
    I fully expect you to experience more "Band-Aid Solutions" in the future. Cali's new $20 minimum wage for fast food workers will have such a financial impact to restaurants' operating costs that your clients will HAVE to cut corners to stay solvent. Sadly, this also means an increased potential of having to troubleshoot and/or repair work done by untrained/unlicensed individuals ("I know a guy that could fix that for ya much cheaper!").

  • @helmsajr
    @helmsajr 8 หลายเดือนก่อน +1

    Great job Chris old units are good for business especially when customer want change them out. You know you will be working on them. it is what it is. lol

  • @VehicleMechanical
    @VehicleMechanical 8 หลายเดือนก่อน +2

    Shocked it wasn't due to low charge, that unit is beat to all hell but god damn it just wont quit

  • @FrNMGuy
    @FrNMGuy 8 หลายเดือนก่อน +8

    You're saying about the high subcool (always with the discharge), but I see the same on my 2-3 ton condensers, too. I'm used to seeing 20 to 30 degrees of subcool........but that's when I'm hitting the 100 to 105 ODT range. The condensers are from 2005 and 10 SEER. Eh? Fuck it. If it rejects heat, it rejects heat.

    • @garypoplin4599
      @garypoplin4599 7 หลายเดือนก่อน

      “Liked” comment, except for the SMUT.

  • @idontneedaname85
    @idontneedaname85 8 หลายเดือนก่อน +2

    Thanks for the sunday drops. Its my Monday and it makes work sooooo much better.

    • @HVACRVIDEOS
      @HVACRVIDEOS  8 หลายเดือนก่อน

      Thanks for watching

  • @zekenzy6486
    @zekenzy6486 8 หลายเดือนก่อน +1

    Great video. Thank you for sharing. Have a nice weekend

  • @Goldstacker1972-kp2bh
    @Goldstacker1972-kp2bh 8 หลายเดือนก่อน +1

    Yea the electrical section is usually about 5 to 6 inches at the most.

  • @MTHVAC916
    @MTHVAC916 8 หลายเดือนก่อน +2

    Great video! I work on a lot of those same York units.

  • @oscarguillen1729
    @oscarguillen1729 8 หลายเดือนก่อน +1

    Chris, I noticed that the return air temperature was very low on the first unit that you checked vitals on. The condenser approach was also at 0. Is it possible that the unit was just underperforming due to the cold conditions it was running in? I believe that if you had a higher load both indoor and outdoor, we might see better performance. For the second unit, I believe it looked better because the outside air temp had risen to 70.

  • @Hvacmike
    @Hvacmike 8 หลายเดือนก่อน +2

    What iPad holder do you use, is it magnetic so you can stick it to the RTU?
    Also, ugh sometimes I think we are actually professional turd polishers, not technicians.

  • @Uhh.thankyou
    @Uhh.thankyou 8 หลายเดือนก่อน +2

    loving that intro music

  • @usfarmcop
    @usfarmcop 8 หลายเดือนก่อน +2

    I want the old intro back please 👉🏻👈🏻😌

  • @jonjo6886
    @jonjo6886 8 หลายเดือนก่อน

    You've got to give these old units some credit, by the visible condition they're real old and there obviously hasn't been a load of major, new parts fitted.

  • @stephenmcconnell4302
    @stephenmcconnell4302 5 หลายเดือนก่อน +1

    I’ve been customers with rental properties and refused to work on old units with multiple issues and they don’t want to pay to replace them! I don’t want to assume responsibility for units I’ve never serviced in really bad condition

  • @quimshtgclg
    @quimshtgclg 4 หลายเดือนก่อน

    I wonder if you could use plastic electrical conduit for those wires , just a thought. But hey if you don’t have any, wire ties work . Great video.

  • @fshn76
    @fshn76 8 หลายเดือนก่อน +4

    Sadly most of the units I work on looks like those. We just have to bandaid them and move on. Very rarely will the customers accept our recommendations.

  • @kmagnussen1052
    @kmagnussen1052 8 หลายเดือนก่อน +3

    Corporations frequently have policies that require doing the same thing over and over again which in the long run costs more. There should be a spread sheet where it determines the time to replace rather then fix. Every motor or compressor has a mean time before failure. As you get close to that MTBF you schedule a replacement it should be on a calendar. This failed approach to management looses money.

  • @kanapalaamruthteja3603
    @kanapalaamruthteja3603 8 หลายเดือนก่อน +2

    The intro music is from this music video.
    ELFL - Zero Gravity

  • @dipley3771
    @dipley3771 8 หลายเดือนก่อน +1

    I noticed on that first unit you had a 61 degree liquid line . Wonder if you had a restricted drier

    • @dipley3771
      @dipley3771 8 หลายเดือนก่อน +1

      Good video nonetheless, I’m ready for the season

  • @CSXRailfan6588
    @CSXRailfan6588 8 หลายเดือนก่อน +1

    You could actually use 1/2 inch electrical seal tite to replace the wire conduit going to the motor it is the same thing

  • @jonathonpettit9418
    @jonathonpettit9418 8 หลายเดือนก่อน +1

    Hey Chris, I had a question. I’m about to swap a 15 ton package unit in a roof and I have never done it. Would it be possible to make a video describing what all goes into it? 👍👍

  • @farashvac
    @farashvac 8 หลายเดือนก่อน +1

    Hey Chris , I thought R to Y1 should be 0v as t-stat switch is closed , Y1 To C(x) should have 24v…or is that just with residential , I’m not familiar with commercial, thanks a lot man.

  • @wtfman5313
    @wtfman5313 8 หลายเดือนก่อน +1

    I'll use a piece of 1/2 or 3/4 pvc for conduit on those Condenser Fan Motor electrical connections where you can't find it from the dealer. Raintight works good too.

    • @HVACRVIDEOS
      @HVACRVIDEOS  8 หลายเดือนก่อน +1

      Great idea

  • @alsantiago978
    @alsantiago978 2 หลายเดือนก่อน +1

    How come you didn’t check the blower wheel? Old blowers pack dust and air movement is restricted

  • @topreventretaliations3590
    @topreventretaliations3590 8 หลายเดือนก่อน +1

    What about the cooler you have in the van, is that also on TrueTechTools?
    Yeti, I think you said anyway, what's your review?
    Awesome videos!!

  • @w9awx1
    @w9awx1 8 หลายเดือนก่อน +1

    Question on the other unit that you replaced the entire unit. Roughly how much total time was that job to swap out the entire unit with the crane?

  • @DrGreenGiant
    @DrGreenGiant 8 หลายเดือนก่อน +1

    Apart from being old, what was wrong with the units? You mentioned a few times it was junk (definitely looks it!) but what's actually wrong with it as it seems to be working?
    I'm not in this field so just curious to learn and have been loving your videos for ages now. Thank you!

    • @tavhigh
      @tavhigh 3 หลายเดือนก่อน

      The coils on both units are deteriorating, making it harder to reject heat efficiently.

    • @DrGreenGiant
      @DrGreenGiant 3 หลายเดือนก่อน

      @@tavhigh ah gotcha. So I guess that the interface from the gas carrying tubes and the fins that provide surface area fails so heat doesn't get radiated as well? Fascinating stuff! Ty

  • @PyramidHvac
    @PyramidHvac 8 หลายเดือนก่อน +1

    Another great job Chris

  • @NoName_-vu3jc
    @NoName_-vu3jc 8 หลายเดือนก่อน +1

    love your videos man, keep up the good work!

  • @Phantomrooster29
    @Phantomrooster29 8 หลายเดือนก่อน +2

    The man the legend

  • @stephenmcconnell4302
    @stephenmcconnell4302 5 หลายเดือนก่อน +1

    York rooftops heat exchangers are money I have a customer with a bar and instead of replacing the rtu they want me to keep installing more ductless splits

  • @Goldstacker1972-kp2bh
    @Goldstacker1972-kp2bh 8 หลายเดือนก่อน +2

    It's crazy how slow they look on video. Also it always looks like it runs backwards on video. Probably because some cameras run mirrored while others look normal.

  • @DW-bo3qw
    @DW-bo3qw 8 หลายเดือนก่อน +1

    I like to use a small piece of liquid tight zip tied to the fan guard for the wires

  • @NATHANFREDERICK-rs7yb
    @NATHANFREDERICK-rs7yb 8 หลายเดือนก่อน +2

    Jaw-dropping!!, you didn't reclaim and weigh in the charge. You're slacking!!

    • @HVACRVIDEOS
      @HVACRVIDEOS  8 หลายเดือนก่อน

      lol, Ill do it twice on the next one to make up for it

  • @Echo__Whiskey
    @Echo__Whiskey 8 หลายเดือนก่อน +1

    thanks for the code i needed some new veto's. $40 savings vs veto's website

    • @HVACRVIDEOS
      @HVACRVIDEOS  8 หลายเดือนก่อน

      Money well spent

  • @whittemamba4917
    @whittemamba4917 6 หลายเดือนก่อน +1

    What app is that that he uses when he gauges up?

    • @HVACRVIDEOS
      @HVACRVIDEOS  6 หลายเดือนก่อน

      The app is called MeasureQuick

  • @MekkaVirus
    @MekkaVirus 8 หลายเดือนก่อน

    If there is no conduit left, I pull the condenser fan leads through 1/2" liquid tight and call it a day.

  • @chrisconney9097
    @chrisconney9097 8 หลายเดือนก่อน +2

    Add a little gas. Pressure a little low

    • @hackendan1921
      @hackendan1921 8 หลายเดือนก่อน

      Already has high subcooling. Liquid building up in the condenser.

  • @logik110
    @logik110 8 หลายเดือนก่อน +1

    Thank you very much for the amazing videos. I love to watch them. Your channel is like a criminal TV show, and I always want to know "who" the "killer" is.
    I have one question about capacitors for condenser motors. Seeing that this is a 3 phase unit, it wouldn't be better for the manufacturer to connect the motor as 3 phase. Then you will not need the capacitor. Also considering that the capacitor is next to the contactor, you don't save any cost on wires. Even with a capacitor it looks to me like it's more expensive.
    Radek
    PS: I know only 3 phase systems in Europe, don't know if it's similar in the US. 3 legs, each shifter by 120°.

    • @HVACRVIDEOS
      @HVACRVIDEOS  8 หลายเดือนก่อน

      Thats a good question, Ill see If I cant talk about that on my next live stream

    • @ThunderClawShocktrix
      @ThunderClawShocktrix 7 หลายเดือนก่อน

      I think it was jsut so the OEMS couls stock fewer motors using the smae ones for both singe phase home ACs and commeircal 3phase units and yes its dumb

  • @davidl.579
    @davidl.579 8 หลายเดือนก่อน +1

    " Polishing a Turd" is a term you use with your clients or just with your fan base?

    • @HVACRVIDEOS
      @HVACRVIDEOS  8 หลายเดือนก่อน

      Just on the videos, the customers hear a more professional description

  • @johnhaller5851
    @johnhaller5851 8 หลายเดือนก่อน +1

    Do you charge the customer travel time? Is there a distance where overtime is cheaper than a second trip charge? I know it gets hard to work overtime, and on the hottest days, nearly impossible. Or is it just some customer policies that they won't pay for overtime?

    • @HVACRVIDEOS
      @HVACRVIDEOS  8 หลายเดือนก่อน

      Ill see if I cant elaborate on that during my next live stream this coming Monday

  • @Shameu_uss
    @Shameu_uss 7 หลายเดือนก่อน +1

    i mean if the unit is not discharging the heat at the condenser you wouldnt have a sub cooling not to high of a subcool so probably a restriction

  • @craig1611
    @craig1611 8 หลายเดือนก่อน +1

    The pistons like to plug up on those units

  • @rightconditions2010
    @rightconditions2010 8 หลายเดือนก่อน +1

    I'm buying that bag!

  • @krazy1z
    @krazy1z 8 หลายเดือนก่อน +1

    It's all about giving the customer the information so they can make an informed decision. And I hate that model of York. They've lived a great life time to go lol

  • @fischhead2
    @fischhead2 8 หลายเดือนก่อน +1

    Hey there Chris!
    Keep up the good work! I wanted to ask why you still use your smartphone to film? Why are you not using a GoPro(or another brand) with a belt from which you can film from you chest? Would be easier to work for you since you would have both hands free.
    Just a suggestion, dont get me wrong. 😄

  • @richy581
    @richy581 8 หลายเดือนก่อน +1

    What's the name of the song in the beginning I like it

  • @Byron88
    @Byron88 8 หลายเดือนก่อน +1

    I hate the design of York equipment I find its difficult to work on for no reason especially their electrical sections , the newer large units have a much larger electrical section but the smaller ones (10t or less) are still brutal

  • @throttlebottle5906
    @throttlebottle5906 7 หลายเดือนก่อน +1

    I see they added "stable volume" to video playback options. hopefully no more doing backflips over the chair when watching? 🤣
    not so much here, but some across "the tube" have very extreme volume changes from quiet to blown out audio loud. lol

    • @garypoplin4599
      @garypoplin4599 7 หลายเดือนก่อน

      Thanks for that ‘tube trick. I hadn’t noticed it before your comment. Much appreciated. I agree: some vids have extreme amplitude swings! Not so much Chris’ posts. The only swings in his is pitch when he needs to talk over ambient noise of running units. No noticeable volume changes.

  • @thesilentonevictor
    @thesilentonevictor 8 หลายเดือนก่อน +1

    You polish her well chris

    • @HVACRVIDEOS
      @HVACRVIDEOS  8 หลายเดือนก่อน

      Thanks bud

  • @Funthingstowatch
    @Funthingstowatch 8 หลายเดือนก่อน +1

    why dose the spare belt not fly up into the blower? 13:49

    • @HVACRVIDEOS
      @HVACRVIDEOS  8 หลายเดือนก่อน +1

      The suction is not nearly that strong

    • @Funthingstowatch
      @Funthingstowatch 8 หลายเดือนก่อน

      @@HVACRVIDEOS thank you so much I watch your vids every time you uploade

  • @d.l.harrington4080
    @d.l.harrington4080 8 หลายเดือนก่อน +2

    Just to let you know, I hate remote EMS controls. No local control.

  • @RickRick-sw7mb
    @RickRick-sw7mb 8 หลายเดือนก่อน +1

    You know what you could of done is the dead motor capacitor how 10uf and it good and replace the good motor but bad capacitor.

  • @arthouston7361
    @arthouston7361 8 หลายเดือนก่อน +2

    Those units are going to be late 1990s....like 97 or 98. Do you have a serial number?

  • @billynomates920
    @billynomates920 8 หลายเดือนก่อน +1

    120 nice and warm 🥵 uk so anything above 80 and i start to melt.😃

  • @professional-lead137
    @professional-lead137 8 หลายเดือนก่อน +1

    What’s the name of the song on your new intro?

    • @HVACRVIDEOS
      @HVACRVIDEOS  8 หลายเดือนก่อน +1

      Shoot me an email to remind me to look up the song name for you HVACRVIDEOS@GMAIL.COM

  • @castirondude
    @castirondude 8 หลายเดือนก่อน

    At some point all you're saving is the sheet metal because everything inside them needs to be replaced ... no real benefit to keep the old units going, unless maybe the new units have poor quality but I don't think that's the case.

  • @Thomas-lq1jw
    @Thomas-lq1jw 8 หลายเดือนก่อน +1

    Maybe the customer hopes the contactors kill a compressor so they can convince corporate to buy replacements 😉

  • @jonleiend1381
    @jonleiend1381 8 หลายเดือนก่อน +2

    Do not take in a negative way just commenting fore engagement and question. Started your video 5 minutes in I am thinking just replace all 4 fans before spending time to figure out what is wrong with them. Cheaper to replace cheap parts than spend the time figuring out why a rusty fan motor is not working properly.

    • @drewc7479
      @drewc7479 8 หลายเดือนก่อน

      Lol is that a serious comment? Replace all the fan motors rather than get your customer cooling from a possible bad capacitor? Could be bad fan cycling etc .
      Most techs are like what you commented , and it keeps guys like us so busy

    • @jonleiend1381
      @jonleiend1381 8 หลายเดือนก่อน

      @@drewc7479 From what I saw in the video it took him about 30 seconds to figure out that the one with a quarter inch of play was bad. So he is already going to have to make a trip to the supply house and get new motors. Already going to have his tools out. If all 4 motors are about the same age why turn it in to 4 separate calls to replace one motor at a time. I am not the expert but if the capacitor goes bad it is a good indication that the motor is going bad also.

    • @jonleiend1381
      @jonleiend1381 8 หลายเดือนก่อน

      Before you reply that the supply house did not have 4 motors I did hear that and would have made his job easer if they had what he needed.

    • @drewc7479
      @drewc7479 8 หลายเดือนก่อน

      @@jonleiend1381 I've changed many capacitors in the past and never went back to replace the fan motor. I can see your point , but sometimes to a customer that doesn't seem logical and they just need what's not working to be fixed

    • @johnhaller5851
      @johnhaller5851 8 หลายเดือนก่อน

      You must have clicked out before the end of the video. The customer doesn't want to pay for the extra motors. He just follows the customer direction.

  • @sirblake3
    @sirblake3 5 หลายเดือนก่อน +1

    I hate dealing with ems

  • @UnbornHeart2020
    @UnbornHeart2020 8 หลายเดือนก่อน +1

    go pro with a band, it can go over a hat for hands free work

  • @Casal70
    @Casal70 8 หลายเดือนก่อน +1

    Could have been a great trailer from 17:47 to 17:57

  • @arcticarrowhvacr
    @arcticarrowhvacr 8 หลายเดือนก่อน

    If we could build equipment to last 30 years in the 1990s, todays stuff should last double that. Sadly the trend is opposite. Too many people have blinders on now, and replace working units all because of the green new scam. Great repairs Chris.. ❄️

  • @TheJj787
    @TheJj787 8 หลายเดือนก่อน +2

    The real problem is York

    • @mangoisback
      @mangoisback 8 หลายเดือนก่อน

      Yeah and their tech support, you gotta go through loopholes to get a representative

  • @larryfried7742
    @larryfried7742 5 หลายเดือนก่อน +2

    I'm in the service electronic business. And you have to know when to chalk it up. What happens if you replace all those components and still don't get the results you want.? When things are really tired and beat down old The labor of basically doing a rebuild might come close to the cost of a new unit. And what about warranty.? You might have to tell the customer that you can't warrant the rest of the unit because it's old with aging components. Maybe one of those old compressors could easily just fail. Well...I'm sure I'm not telling you anything that you don't already know. You could possibly suggest a second opinion if you have another tech company that's honest. When these roof mounted heat stressed units get tired and beat down it's a crap shoot. as too how much life these dinosaur's have left in them.

    • @drodriguez394
      @drodriguez394 2 หลายเดือนก่อน

      Yeah man you’re probably right to a point. But this isn’t a broken Xbox or computer or cell phone. Things you can live with out and shop around for a new one and all things relative, cheap,
      Customer calls in no ac no heat, they want solutions. Because they’re uncomfortable and depending on the season and where you are in the country, pipes are at risk.
      You may give the option to replace, but a lot of our job is either doing temporary repairs to get them heat or ac, or fixing shit. We’re talking about 10’s of thousands to replace this thing. Depending on if he’s selling it and marking it up.
      We’re professional problem solvers. Often times we don’t have a lot of time to screw around with second opinions from other company’s and so forth. Offer solutions repair and replacement. Put the ball in their cou
      , it’s not your place to spend the customers money. It’s your job to offer solutions

    • @larryfried7742
      @larryfried7742 2 หลายเดือนก่อน

      @@drodriguez394 I hear you and understand what you mean. Many factors go into how to approch repairs, My point is that sometimes these units are so beat down when you fix the current problem there's 10 other things that are hanging by a thread. Yes you can keep throwing parts in and getting it up and running temporalily. Which is GOOD. But sometimes there comes a point where you just got to weigh the cost of repairing and labor against replacement. If the customer is willing to keep throwing money down a black hole, by all means have at it. I work on Electronics and have for 50 years. The decisions are a lot easier for me to make when you're not dealing with huge replscement costs . I understand that. But on the other hand I wouldn't want to keep going out to resusitate a dying machine. Constant recalls and searching for hard to find or expensive parts that come from god knows where and when can be a frustrating problem.. If you have the time to keep going out on a unit that constantly breaks down every other month while juggling a bunch of other calls,by all means Go for it! IMO, you'll eventually wind up with an angry ,pissed off, exhaused customer who will blame it all on you everytime it takes a dump. That was my point. Not that you didn't have the expertise 'to get the old girl going again.

  • @kevxsi16v
    @kevxsi16v 4 หลายเดือนก่อน +2

    You don’t seem to like older units, I would politely disagree with you, I find the older stuff is much better made maybe not as efficient but definitely more robust I try and repair whenever possible obviously it gets to a point where the units are rusted out and there isn’t a lot you can do about that but older stuff is definitely definitely much better

  • @groverstreet7128
    @groverstreet7128 8 หลายเดือนก่อน +1

    The main issue here is that you’re working on York brand equipment. I’ve always thought York was straight trash and a waste of money for anyone to purchase.

  • @gunnargu
    @gunnargu 8 หลายเดือนก่อน +2

    EMS System
    Energy Management System System
    A bit of RAS Syndrome 🤣

  • @clementnaze5645
    @clementnaze5645 8 หลายเดือนก่อน +2

    Mojave motors like MacOS Mojave