  • @Rowly_M
    @Rowly_M 27 วันที่ผ่านมา

    Hey Anthony
    If I may ask, why did you put a 25A MCB on the outlet of the 8K inverter? Is it not going to cause a trip of the breaker at +- 5750 W?

    • @anthonymwambazi7390
      @anthonymwambazi7390  26 วันที่ผ่านมา

      the maximum output of the inverter on backup is about 26A

    • @Rowly_M
      @Rowly_M 26 วันที่ผ่านมา

      @@anthonymwambazi7390, I'm a bit confused, in the video, you are referring to the Deye 8kW and the datasheet states that the max output is 38.3A. Can you share where the 26 A max is from?

    • @anthonymwambazi7390
      @anthonymwambazi7390  26 วันที่ผ่านมา

      @@Rowly_M my bad i don't claim to be an expert that well, the rated current if i stand to be corrected was based the supplier for warranty purposes i believe you can kindly confirm with Solar Europe on there warranty requirements on the 8 Kw inverter Purchases. Apologies if i misled you on that.

    • @Rowly_M
      @Rowly_M 25 วันที่ผ่านมา

      @@anthonymwambazi7390 , I think you mistakenly used the Deye 5kW inverter specs when doing this installation. Maybe check on the customer and increase the MCB rating on the output (backup load). The 25A on the output of an 8kW only allows the customer to use 66% of the inverter capacity.

    • @anthonymwambazi7390
      @anthonymwambazi7390  25 วันที่ผ่านมา

      @Rowly_M you could be right please also check warranties from the suppliers that will help as well

  • @IO-zz2xy
    @IO-zz2xy ปีที่แล้ว +1

    Thank you for sharing the video. BTW, was this for a townhouse complex or small business. 190 Amp draw ??
    Regards

    • @anthonymwambazi7390
      @anthonymwambazi7390  ปีที่แล้ว +2

      For a residential property 190A DC from battery at 48v not 230v Ac

  • @johanbester4484
    @johanbester4484 11 หลายเดือนก่อน

    Very neat install