- 88
- 429 007
Anthony mwambazi
เข้าร่วมเมื่อ 29 มิ.ย. 2012
6 Kva Solarplanet Hybrid inverter with 5 x 545 watts panels and a Dyness A48100 lithium battery.
Super quiet inverter no visible fans, has a large cooling heat sink, it is an app based programmed device.
มุมมอง: 318
วีดีโอ
August 24, 2004, Solar Practical hands on Training
มุมมอง 3113 หลายเดือนก่อน
Our practical Hands on training gives you confidence in your installations after your studies in theory.
Solar hands on practical training 101 August 10/2004
มุมมอง 5104 หลายเดือนก่อน
To empower and give great confidence to installers.
Hands on Training on Solar installation August
มุมมอง 7424 หลายเดือนก่อน
Hands on training practicals in Solar installations to help be confident and compliant
30Kva Deye Inverter with 13 Kwp Array and 6 First battery Lithium Installation
มุมมอง 5145 หลายเดือนก่อน
30Kva Deye Inverter with 13 Kwp Array and 6 First battery Lithium Installation
2.5Kva Solarwize Trolley inverter with x 450 watts panels in parallel.
มุมมอง 3175 หลายเดือนก่อน
2.5Kva Solarwize Trolley inverter with x 450 watts panels in parallel.
2x Lux power Sna inverter in Parallel with 200Ah Dyness Pro box and 580 Trina Solar panels install.
มุมมอง 6016 หลายเดือนก่อน
2x Lux power Sna inverter in Parallel with 200Ah Dyness Pro box and 580 Trina Solar panels install.
June Solar practical training on installations
มุมมอง 2056 หลายเดือนก่อน
June Solar practical training on installations
Lux power Sna 5000 X2 with six Svolt batteries upgrade.
มุมมอง 1.5K6 หลายเดือนก่อน
Lux power Sna 5000 X2 with six Svolt batteries upgrade.
Prt2 Lux power Sna 5VA, Parallel installation with 3 Volta Stage 1 Lithium batteries and 16x 550W P.
มุมมอง 6087 หลายเดือนก่อน
Video from Anthony Mwambazi
Sna 5000va Lux power in parallel with 16x 550 watts, Volta stage 1x 3 installation in progress l.
มุมมอง 9767 หลายเดือนก่อน
Sna 5000va Lux power in parallel with 16x 550 watts, Volta stage 1x 3 installation in progress l.
Hands on Practical training on Solar Installations prt2
มุมมอง 1.1K8 หลายเดือนก่อน
Hands on Practical training on Solar Installations prt2
Hands on Practical training on Solar installations one on one.
มุมมอง 7858 หลายเดือนก่อน
Hands on Practical training on Solar installations one on one.
Lux power Sna 5Kva in action live demonstration
มุมมอง 7059 หลายเดือนก่อน
Lux power Sna 5Kva in action live demonstration
Solar installation training one on one
มุมมอง 5359 หลายเดือนก่อน
Solar installation training one on one
5Kva Deye inverter, 6x 550watts panels with 10kWh Dyness power box pro Dyness battery
มุมมอง 1.2K10 หลายเดือนก่อน
5Kva Deye inverter, 6x 550watts panels with 10kWh Dyness power box pro Dyness battery
5Kva lux power SNa parallel setup with 10x 450watts panels
มุมมอง 5K11 หลายเดือนก่อน
5Kva lux power SNa parallel setup with 10x 450watts panels
Installation of a all in one 5kva SRNE back up system
มุมมอง 60511 หลายเดือนก่อน
Installation of a all in one 5kva SRNE back up system
Lux power 5kva Sna with two Hina Ess Lithium battery back up system
มุมมอง 1.9Kปีที่แล้ว
Lux power 5kva Sna with two Hina Ess Lithium battery back up system
Sneak preview on our last hands on training
มุมมอง 630ปีที่แล้ว
Sneak preview on our last hands on training
Sneak peak of our private session hands on Solar installation training
มุมมอง 1.4Kปีที่แล้ว
Sneak peak of our private session hands on Solar installation training
5KVa Sunsynk Hybrid inverter with 4.6Kwh Five star Lithium as a backup system
มุมมอง 1.1Kปีที่แล้ว
5KVa Sunsynk Hybrid inverter with 4.6Kwh Five star Lithium as a backup system
5KVA Growatt inverter with Hoselect 4.8kwh Battery and 1.4Kwp panels
มุมมอง 820ปีที่แล้ว
5KVA Growatt inverter with Hoselect 4.8kwh Battery and 1.4Kwp panels
5kw lux power Snl correction installation part 2 ( Hubble lithium battery X2)
มุมมอง 2.1Kปีที่แล้ว
5kw lux power Snl correction installation part 2 ( Hubble lithium battery X2)
12kw Lux power Lxp Gride tie inverter with 5.12kwh LifeTide batteries and 16x555 longi modules
มุมมอง 2Kปีที่แล้ว
12kw Lux power Lxp Gride tie inverter with 5.12kwh LifeTide batteries and 16x555 longi modules
8Kw Deye hybrid inverter with 2x 5.12 Dyness batteries and 4.6Kwp panels
มุมมอง 4.2Kปีที่แล้ว
8Kw Deye hybrid inverter with 2x 5.12 Dyness batteries and 4.6Kwp panels
Automatic Transfer switch automation with solar, Generator and utility
มุมมอง 4.5Kปีที่แล้ว
Automatic Transfer switch automation with solar, Generator and utility
5Kw Sunsynk inverter with a Sunsynk Battery as a back up system
มุมมอง 3.2Kปีที่แล้ว
5Kw Sunsynk inverter with a Sunsynk Battery as a back up system
Are you more worried about the battery draw? So if we were to run the inverter at 3.5kw, lets say to heat the geyser using solar, would you still advise against this?
Hey is it bad to set it at 265 high volt or just leave it at 260
@@keenanwolf3097 I would set to 252v as a standard South African regulation
Equipment damage happens at 270 and above
@@anthonymwambazi7390 so it's fine not bad cuz it's been fluctuating allot at high volts so my power goes off like almost 15 times a day so I've decided to add the extra 5 volts
Hi Anthony I have been watching your videos and they are really good gave me the confidence to do the work myself, I have a query though on the solar panel how do I connect 4 panels together do I go parallel or series, I have a Luxpower 5kva invetor
hi thank you, you connect the panels in series
I have the same installation. I have to use the lead acid function, my dyness battery is not seeing the LuxPower inverter. Ive change the cables, my dip switch is on 3. but no communication between the battery and inverter. If lead acid is use communication start. Can you help?
wer are u available?
Looks very good, also thinking about building something like this with 12k HV inverter. The 51.2v battery you use are connected in series with nothing special? Allot of people say you need special high voltage battery's that are more expensive.
@@Maginone2 yah used to be only if you are going more than 12 you need more control and protection
@@anthonymwambazi7390 wow that great, allot of people don't know this from a forum I'm in. Everyone is very curious. I want to build a Deye 12k HV system in The Netherlands and I'm doing research for batterys. If any 51.2v battery can be put on series and connected to the Deye and it can read the BMS data that would me awesome.
@@anthonymwambazi7390 thank you for the information. So you can read all BMS data and no errors with 300v system now? Low Volt 51.2v battery's are cheaper then High Volt 51.2v! battery's😅 so that why I ask, and so other people will also know that this setup works🤩 would help allot of people that are building High Volt systems. Do you have a link to the battery where you buy them? So I can check specs and maybe get them myself.
@@anthonymwambazi7390 talked to a seller and found on a forum. That if one of the batteries goes offline the rest will get a hit of the high voltage momentum in the system and the BMS will die..
Second battery show -100
🎉 please help me there's GFN is for
Hey Anthony If I may ask, why did you put a 25A MCB on the outlet of the 8K inverter? Is it not going to cause a trip of the breaker at +- 5750 W?
the maximum output of the inverter on backup is about 26A
@@anthonymwambazi7390, I'm a bit confused, in the video, you are referring to the Deye 8kW and the datasheet states that the max output is 38.3A. Can you share where the 26 A max is from?
@@Rowly_M my bad i don't claim to be an expert that well, the rated current if i stand to be corrected was based the supplier for warranty purposes i believe you can kindly confirm with Solar Europe on there warranty requirements on the 8 Kw inverter Purchases. Apologies if i misled you on that.
@@anthonymwambazi7390 , I think you mistakenly used the Deye 5kW inverter specs when doing this installation. Maybe check on the customer and increase the MCB rating on the output (backup load). The 25A on the output of an 8kW only allows the customer to use 66% of the inverter capacity.
@Rowly_M you could be right please also check warranties from the suppliers that will help as well
hi, tell me. if I forgot the password for the router and the inverter is in client mode trying to connect. how to set a different password or even a ssid?
hi, tell me. if I forgot the password for the router and the inverter is in client mode trying to connect. how to set a different password or even a ssid?
hi, tell me. if I forgot the password for the router and the inverter is in client mode trying to connect. how to set a different password or even a ssid?
hi, tell me. if I forgot the password for the router and the inverter is in client mode trying to connect. how to set a different password or even a ssid?
My battery is not charging to 100%, even of connected to the grid. I am using a 5Kva Luxpower Inverter and a Lemoen batttery.
Good day, can you add a 48V svolt 100Ah to an existing 48V 106Ah svolt system (due to supply issues can’t find another 106Ah svolt) just want to know if the capacity is different if there will be an issue with communication and charging on the svolt
@@henricoventer7710 hello nop you can't add another one of that capacity, they are not compatible
Lovely video ❤
Thanks for r-emphising on SANS 10142- Earth Protection , sadly im also using "Cheap stuff DC Fuse breakers' from Take a lot , now i know .. 😀
How do you sign up for your classes
Looks to me like you're drilling into the battens and not the rafters, though it's hard to tell.
so basically what you are saying is the roof hooks were wrong, am i correct the manufacturer needs to be questioned, Rubicon SA. please advice
What is the use of can bus connection? is it connected to Inverter? Thank you
can bus communication has to do with battery communication with the inveter basically, sending its charging, discharging and temperature parameters to the inverter.
@@anthonymwambazi7390 Thank you for the reply. Is connecting the can bus cable mandatory or optional? I have a problem with my Shoto battery; it frequently looks like a voltage drop, and the inverter is faulty, I have to restart all units.
@@mastox it's Mandatory otherwise you may loose your warranty if the battery is compatible with the inverter
Hello freind i have a sna5000 lux power inverter but the I make a lithium battery with jk bms 5 kw battery but the problem is battery and inverter is not communicate between please help me for battery settings in lux power inverter
I'm struggling to communicate with hoselec to lux power which deep switch should be on and what protocol
@@mathewspetersonkaliwo hi there unfortunately Hoselec does not communicate with Lux power
Great work Tony
Mr Mwambazi i have a lux power 5kva inverter installed in Zambia but the problem we have is the system won't charge when connected to a Generator, what could be the problem? Please assist or your WhatsApp line please.
We have a chint power battery. Is it compatible with a Luxpower?
@@kafwilabanda9127 morning Chint power is not on the compatibility list, however some batteries do work even if they are not on the list, you will have to check with the supplier or manufacturer if they did some tests
He gone
@@amrmedic968 I wonder gone were sir
Good day. If i have 2 batteries connected to my invertor, how woulr i be able to see the battery power left on each battery? How does the house drain from each battery, one at a time or in parallel?
I don't know whether this is a point of concern to the other registered electrician where by there is no earth wire on the light circuit when you do bonding for COC it will not give 0.2 Ohms. What to do in that situation?
What i know as an installation electrician is that everything but be protected by Earth leakage according to the SANS 10142-1
What about setting two CFe -A
wow
This is a beast
Hello sir, can one of those inverters support 12 panels 555W alone? thats 40.99v 13.5 A
Yes you can install 12 panels on one inverter if you split 12 panels between the two mppts of the inverter, remember to update the firmware of the inverter so you increase ISC input of the panel as well
Can you parallel an 8.8kw sunsynk with a 5kw sunsynk?
@@MrSlipperyfusion nop unfortunately you can't
Deye & Sunsynk on hardware side are essentially the same. Which is your preference between the two and why?
Not so much a preference I think mostly budget for the client we are installing.
How much it costs ? Where could i ger i.n lusaka
@@sureshkumar-ux2nq you can purchase one from 5 star I guess
How do we sign up and how much is the cost?
I need training my brother. How can i contact you
@@princekhumalo7737 you can contact me on +27823427946
Hi from New Zealand! That looks very nice.
This guy jumps from one thing to another, I don't understand him at all
@@princekhumalo7737hi what are you trying to understand
Hi Anthony i have 450wats panels x 4 on a 5kw lux power with a cfe battery, load out out goes off when i switch on PV to inverter giving warning 28(eps overload) even when out put MCB is off, what am i missing.
@@davidmilambo4069 hi there looks like you have a battery communication issue
I disagree sir ,450w x 4 panels connected in series can not charge cfe battery at anything above 60 amp charge setting from solar panels unless if reduced to 30amp charge on solar side and if you are using 2 batteries switch off one and charge one at a time 450w x4 panels can not charge 10kw battery system plus work load on top thank you
Are you saying its bad for the inverter to Run more than 2 kw when there is load shedding ?i plan on using thw sna 5000 to run the geyser but only in the day when my pv input is more than 2kw and when Eskom is running
Kindly share your line
How does the essential appliances get connected to ESCOM, is it through the inveter ?
I just did same installation but I used Deynese batteries,problem is they don’t want to communicate with Inveter,even if I used right cable and right code(8) but still it doesn’t communicate,is there another setting I missed?
@@tapsonnkata4950 did you also lift the dips switch 3 on the master
@@tapsonnkata4950 and confirm which cable you used
Where are your classes held?
we are based in Roodepoort
@@anthonymwambazi7390 can I have your email address please
I must say I have learned a lot from your TH-cam videos,..thank you.
Thank you
Another great video by Anthony
@@johanharris3479 Thank you
That's great
I need guide to connect the deye 30kva 3 phases inverter with hi7 sunark 52v 100ah lithium battery connection
@@tiamiyuoladele1902 am not sure about those batteries compatibility to the Deye inverter, if they are not on the compatibility list I would shy away because on high voltage systems there are no second mistakes, fault currents are very high to cause damage to equipment and that equipment is very expensive to replace.
Just so the system now these are systems designed and manufactured for the American market they look very similar to Deye inverter as well.
Antek, this is beautiful my brother!!!